CNP INDUSTRIES WindCrest PSL User manual

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector's use.
INSTALLER: Please leave these Installations Instruction with this unit for owner.
OWNER: Please retain these Instructions for future reference
IMPROTANT SAFETYINSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,
HOODS SHOULD BE INSTALLED WITHVENTILATORS APPROVED FOR USE WITHTHE HOOD.
SEE TABLE –1 OF THIS INSTRUCTIONS FOR APPROVED VENTILATORS.
WARNING - TO REDUCE THE
RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO
PERSONS, OBSERVE THE
FOLLOWING:
A. Installation work and Electrical
Wiring Must be Be Done ByQualified
Person(s) In Accordance With All
Applicable Codes & Standards,
Including Fire-Rated Construction.
“WARNING” To Reduce The Risk Of
Fire, Use OnlyMetal Duct Work.
B. Sufficient air is needed for proper
combustion and exhausting of gases
through the flue (chimney) of fuel
burning equipment to prevent
backdrafting. Follow the heating
equipment manufactures guideline and
Safetystandards such as those
published bythe National Fire
Protection Association (NFPA) and the
American Societyfor Heating,
Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
C. When cutting or drilling into wall or
ceiling, do not damage electrical wiring
and other hidden utilities.
D. Before Servicing or Cleaning Unit,
Switch Power off At Service Panel And
Lock Service Disconnecting Means to
Prevent Power From Being Switched On
Accidentally. When The Service
Disconnecting Means Cannot be Locked,
Securely Fasten A Prominent Warning
Device, Such As A Tag, To The Service
Panel
CAUTION - TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO
DUCT AIR OUTSIDE FOR DUCTED FANS –DO NOT VENT EXHAUST AIR INTO SPACES WITHIN
WALLS OR CEILING OR INTO ATTICS, CRAWL SPACES OR GARAGES.
Read this instruction completely before starting installation. Planning the complete installation before starting any work is
highly recommended. This includes all aspects of the installation including hood location, ducting, electrical requirements,
and adequacy of mounting surfaces.
DUCTING: Use a minimum 8" round duct for VEN030I, VEN060I and VEN060E installations. Use a minimum 10" round
duct for VEN120E, VEN100E, VEN150E and VEN060I-Dual installations. Use #10100 8" - round transition or #10287 10"-
round transition from hood to ducting. Other Transition are available –See your Dealer for details.
INSTALLATION INSTRUCTIONS
HOOD MODELS –PSL & PER
TABLE - 1
Use model VEN030I or VEN060I
for internal ventilator. Use
VEN060E, VEN120E, VEN100E
or VEN150E for remote ventilator
This hood has been designed to be used with the ventilators shown in Table-1.
Before cutting into cabinets, it is necessary to confirm that the correct ventilator
is being used. Your dealer should have reviewed your needs prior to your
purchase. Be sure you have the correct ventilation system. CAUTION: To
Reduce The Risk Of Fire And Electrical Shock, Install This Rangehood Only
With Blowers Manufactured By Wind Crest.
ByCNP INDUSTRIES, INC.
P.O. Box 18645 Anaheim, Ca 92817 (877) 387-6721

.
NOTE: Unit must be vented
to outside of the building.
Prepare soffit or other surface for mounting the hood by
using a minimum 3/4 inch thick plywood mounting plate
prepare with the FIG-1. NOTE THAT A MINIMUM 2-3/4
inch soffit overhang is required to achieve a sufficient
structural support base. The overhang, of course, can be
greater than 2-3/4. Note the position of the hood front
relative to the opening in the mounting plate refer to
FIG-1.
Provide an adequate support structure for attaching the
prepared mounting plate to ceiling structure. Local
building codes should be adhered to at all times.
Remember that your new hood is of sufficient weight that
an adequate support structure is necessary.
Attach and secure the transition to the hood with #6 x 3/8
inch sheet metal screw after inserting one flange of the
transition under the hood flange (Detail instruction is
included with transition). Tape all joints prior to installing
the hood, being careful not expose tape beyond outer edge
of hood top flange. Attach the hood to the prepared
mounting plate and soffit using # 10 wood screws. Holes
are located in the top panel –HINT: marking and pilot
drilling these holes in the mounting plate will aid
installation. The # 10 wood screws should be a minimum
of 3/4 inches long if no other surfaces is located between
the mounting base and hood. If drywall or other surfaces
are positioned between the hood and mounting base the
#10 wood screws must be longer to provide a full 3/4”
engagement of the screw into the mounting plate.
HINT: If you find vibration noise is present because of
cabinet/mounting structure use additional screws, in holes
available to rigidize mounting.
Connect 120 volts –15 amp, 60 Hz power supply through
the conduit hole in the top of hood, connecting to pigtail in
hood junction box, white to white, black to black and
connect green ground wire to power supply ground wire per
local codes. The VEN100E/150E ventilator will require
revision of some wiring in the hood receptacle box and
possible modification of air discharge opening –See
VEN100E/150E instructions.
NOTE: VEN150E requires a 20AMP Power Supply.
The recommended height from counter top or cooking
surface to the bottom edge of the hood is 30 to 36 inches.
Hood is recommended for use over domestic gas or electric
appliances. Not recommended for use over solid fuel fire
appliances
After installing the hood, install the internal blower (see
FIG-2) unit by positioning the blower into bracket- A,
notched blower bracket will center blower, rotating into
position against hood top, and securing with #8 sheet metal
screws via bracket –B. To ease assembly you should
predrive the #8 sheet metal screws before installing the
blower. If the remote ventilator is used see related
instructions.
CAUTION: The hood is of sufficient weight that two
Installers are recommended to prevent injury or damage to
the hood in handling.
Turn the power on at the service entrance and check the
operation of the controls.
NOTE: Be sure that all dampers (Not Supplied) are
operating properly and are free to open.
BACKDRAFT DAMPER
: It is r
ecommended that a backdraft damper be used
in all installations. In cold weather installations it is necessary to use a backdraft
damper to minimize backflow of cold air into room. A non-metallic thermal
break should also be installed to minimize conduction of outside temperatures
through the ductwork. The thermal break should be located as close as possible
to where the ducting enters the heated portion of the house.
SAFTY WARNING:
Turn off power circuit at
the service entrance and
lockout panel before
wiring the range hood.

FIG-2
7
14
B
ROTATE
INTO
POSITION
FIG - 1
MODELS PSL & PER
LAYOUT OPENING BASED ON CENTER LINE OF HOOD
1
8
1
4
7
2
31
5
51
8
1
842
1
1
"A"
17 1
2
3/4" PLYWOOD MOUNTING PLATE
WIRING ACCESS
AREA
FRONT OF HOOD
A
HOOD MODEL
PER36
PER42
PER54
DIM "A"
20 1/2
26 1/2
38 1/2 53 1/2
29 1/2
23 1/2
DIM "A"
PSL66
PSL42
PSL36
HOOD MODEL
PSL54 41 1/2
KNOCK OUTS
COVER
HOOD TOP
HOOD WIRING
MOUNTING
ACCESS
SCREW
REMOVE APPROPRIATE KNOCK OUTS AND CONNECT WIRING
ACCORDING TO HOOD AND BLOWER INSTALLATION INSTRUCTIONS.
CAUTION: ALWAYS INSTALL RECEPTACLE BOX COVER.
RECEPTACLE BOX COVER
COVER IS PACKED WITH FILTERS

1
2
3
4
4
3
2
1
LIGHT
LEFT RIGHT
LIGHT
12 B # 1
18 B # 6
18 R # 22
18 BL #23
18 B # 24
18 W # 9
18 B # 8
18 W # 10
18 B # 7
18 W 18 B
18 BL 18 R
18 W # 5
18 W # 25
18 B # 12
18 W # 13
18 G # 11
18 BL # 3
18 B # 2
18 R # 4
BLOWER
MOTOR
ROTARY
3-SPD
SWITCH
BOX
RECEPTACLE
RECEPTACLE
PLUG
POWER SUPPLY
NGL1
WIRING DIAGRAM-INTERNAL BLOWER & LIGHTING
A
B
1
2
3
SWITCH
LIGHT
I
I
I
II
I
123
456
18 W # 5
Rev B
This manual suits for next models
8
Table of contents
Other CNP INDUSTRIES Ventilation Hood manuals
Popular Ventilation Hood manuals by other brands

Cavaliere
Cavaliere CAV Series installation manual

Zanussi
Zanussi Block 642330 Specifications

Bertazzoni
Bertazzoni Master Series installation manual

ElectrIQ
ElectrIQ eiq90chimbl user manual

ROBINHOOD
ROBINHOOD RSOF60XCOM Installation and operating instructions

Wind Crest
Wind Crest WCG300S Use, care and installation guide