manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. cobas
  6. •
  7. Measuring Instrument
  8. •
  9. cobas Liat Analyzer User manual

cobas Liat Analyzer User manual

6 cm
10 cm
cobas®Liat®Analyzer
Quick Start Guide
This Quick Start Guide is a reference for the cobas® Liat®Analyzer setup. Read the entire cobas®Liat®
System Operator‘s Manual before using it, or running any cobas®Liat®Assay Tubes.
Unpacking the analyzer
IMPORTANT! Retain the shipping container and packaging materials in case you need to return the
analyzer to Roche for any reason.
• Unpack the analyzer from the shipping container.
• Do not apply any force to the door on the top of the unit.
• Handle with care. Use both hands to support the analyzer along the sides of the base.
• Unpack the power supply and other accessories.
• Inspect the outer case, front panel buttons, screen, and rear ports for any shipping damage. Check all
other items for shipping damage. Report any problems to your local Roche representative.
CAUTION! Using an inappropriate power supply may cause malfunction.
Only use the power supply provided, connected to a voltage of 100-240 V
AC, 50-60 Hz.
• Insert the power supply cable into the analyzer power connector
located at its rear.
• Connect the power cable to the power supply. Plug the other end of
the cable into a properly grounded mains outlet.
No special setup is required, all software and default settings are
preloaded prior to shipment.
Analyzer location and operating environment
• Place on a level, vibration-free and non-reective surface, away from
direct sunlight.
• Allow at least 10 cm (4 in) rear clearance for ventilation and at least
6 cm (2.5 in) front clearance for barcode scanning.
• Operating temperature is between 15°C and 32°C (59-90°F), and
relative humidity is between 15% and 80%.
• Locate the analyzer near a grounded mains outlet to avoid the power
cable being a trip hazard.
Connecting to the network enables remote software and assay updates,
automatic time/date synchronization (SNTP), and host connectivity.
• Connect the Ethernet jack on the rear of the analyzer to an appropriate
wall jack using a standard Ethernet data cable with RJ-45 connectors.
Refer to the Operator’s Manual for information on dening the network
environment.
Function buttons
Touch screen
Navigation buttons
Barcode reader
Power indicator Power button
Tube entry door
Tube entry door
USB port
Ethernet port
Power supply
Power connector
Documentation Hardware parts
cobas®Liat®Analyzer Quick Start Guide cobas®Liat®Analyzer
cobas®Liat® System Operator’s Manual cobas®Liat®User ID Card Kit
cobas® Liat®Advanced Tools Key Guide cobas®Liat®Advanced Tools Key
cobas®Liat®Cleaning Tool Guide cobas®Liat®Cleaning Tool Kit
Power supply
Power cable
Touch screen stylus
1
23 4
Parts list
Connect the power supply
Set up the analyzer Network connectivity (optional)
• Either choose the Login button on the screen or the Login function
button, and then do one of the following:
• Enter your user ID, and then choose the OK button.
For the  rst logon the default user ID is ADMIN.
• Choose the Scan button, and then scan the barcode on your User
ID card.
WARNING! Do not stare into the laser beam. The analyzer laser is a
class 2 laser product.
Please refer to the cobas® Liat®System Operator’s Manual and the assay
speci c package insert or Instructions for Use for instructions on running
an assay.
Press and hold the power button until both the power indicator and the
touch screen turn dark.
If you have any questions or problems, please contact your local Roche
representative.
In the U.S., call the following number: 1-800-800-5973.
Patents: http://www.roche-diagnostics.us/patents
The initialization process takes a few minutes from power up to display of
the login screen.
• Press and release the power button.
• The touch screen lights and becomes active, and the power indicator
lights up.
• The tube entry door automatically opens and closes.
• The splash screen and progress messages (e.g., “Loading. Please
wait...”) are displayed.
• Wait for initialization to complete before proceeding.
NOTICE Do not insert an assay tube or other items into the analyzer
during initialization. Doing so will damage the assay tube and possibly
the analyzer.
Roche Molecular Systems, Inc.
1080 US Highway 202 South
Branchburg, NJ 08876
USA
Made in Switzerland
08416222001
Roche Diagnostics GmbH
Sandhofer Strasse 116
68305 Mannheim
Germany
© 2015-2017 Roche Molecular Systems, Inc.
COBAS and LIAT are trademarks of Roche.
All other product names and trademarks are the property of their respective owners.
6
7 8
5
Roche Support
Log on to the analyzer
Run an assay Power off the analyzer
Power on the analyzer
Document information
Revision history Document version 8Revision date November 2017 Changes Pictures and software reference updated.
This publication applies to cobas®Liat®Analyzer software version 3.2.
• Enter your password, and then choose the the OK button. When
prompted, change your password.
• On the  rst logon the Administrator should ensure that the date and
time are set correctly (Settings > System > Time & Date).

Other cobas Measuring Instrument manuals

cobas Accutrend plus User manual

cobas

cobas Accutrend plus User manual

cobas Accutrend plus User manual

cobas

cobas Accutrend plus User manual

cobas h 232 User manual

cobas

cobas h 232 User manual

cobas Urisys 1100 User manual

cobas

cobas Urisys 1100 User manual

cobas b 101 User manual

cobas

cobas b 101 User manual

cobas h 232 User manual

cobas

cobas h 232 User manual

Popular Measuring Instrument manuals by other brands

Outline SPL Control SA manual

Outline

Outline SPL Control SA manual

ParTech 8100 instruction manual

ParTech

ParTech 8100 instruction manual

Aethlabs microAeth MA200 operating manual

Aethlabs

Aethlabs microAeth MA200 operating manual

Emerson Daniel 3415 Maintenance and troubleshooting manual

Emerson

Emerson Daniel 3415 Maintenance and troubleshooting manual

VOLTCRAFT MF-100 operating instructions

VOLTCRAFT

VOLTCRAFT MF-100 operating instructions

Badger Meter ORION SE Installation data

Badger Meter

Badger Meter ORION SE Installation data

TSI Instruments 9535A Operation and service manual

TSI Instruments

TSI Instruments 9535A Operation and service manual

PCB Piezotronics 356A14 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 356A14 Installation and operating manual

FixPosition Vision-RTK 2 Starter Kit quick start guide

FixPosition

FixPosition Vision-RTK 2 Starter Kit quick start guide

Procare MicroFET 2 manual

Procare

Procare MicroFET 2 manual

Keysight Technologies 16034G Operation manual

Keysight Technologies

Keysight Technologies 16034G Operation manual

BRONKHORST FLEXI-FLOW Compact quick start guide

BRONKHORST

BRONKHORST FLEXI-FLOW Compact quick start guide

Elvaco CMi4170 user manual

Elvaco

Elvaco CMi4170 user manual

Extech Instruments MW12 user guide

Extech Instruments

Extech Instruments MW12 user guide

ThermoWorks I.R.K. operating instructions

ThermoWorks

ThermoWorks I.R.K. operating instructions

Onicon F-2500 series Installation and operation guide

Onicon

Onicon F-2500 series Installation and operation guide

Sacher Lasertechnik TEC-500 Technical documentation

Sacher Lasertechnik

Sacher Lasertechnik TEC-500 Technical documentation

HiWeigh X1FM user manual

HiWeigh

HiWeigh X1FM user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.