Coburg CBD1805 Guide

Coburg Technology Pty Ltd.
+61 2 9651 2930 www.coburgtechnology.comUnit12, 252 New Line RoadDural NSW 2158
PRODUCT MANUAL &
WARRANTY CARD
SAFETY PRECAUTIONS
The Product Manual contains several important safety precautions, make sure to follow
instructions of all such precautions to keep yourself from harm(s) and your property from
damage(s).
Please do not use the Product in any circumstance involving incompatible voltage or current, or
your entitlement to the after-sale services might be jeopardized.
This douche seat is supplied with a backow protection device complying with AS/NZS 3500.1. no
further backow prevention is required for connection to the water supply.
The Product Manual contains all necessary information relating to quality warranty, therefore,
keep it in good custody please. Along with product improvements and technology updates,
certain parameters of the Product might be revised, in case of which, no specic notice will be
released separately, please always refer to current tag information of the Product you purchased
for reference.
CBD1805 / CBD1807 / CBD1808

12
THANKS FOR BEING THE USER OF COBURG PRODUCT!
• Coburg Technology oers the customers a chance to enjoy reliable perfor-
mance of the Product without compromising their expectation on elegant life in
the coming years. As our customer, you will nd nothing to criticize about
appearance and reliability of the Product as it is so satisfying, we can’t help being
proud of our Product and we believe you do too.
• Please take a few minutes to read the Product Manual and pay special attention
to instructions about maintenance and cleaning.
• All information contained herein are based on the latest information about the
Product made available to the public. In Coburg, we keep improving quality of
our product in a consistent way and we reserve all rights to change/modify
properties of the Product, its package and its practicability anytime without
releasing any prior notice.
TABLE OF CONTENTS
Safety Precautions.............................................................................................3-4
Control Panel........................................................................................................5
Quick Start Guide.................................................................................................6
Usage/Operation Method..................................................................................7-9
Preparations Prior To Initial Usage/Operation......................................................10
Functional Test...................................................................................................11
Maintenance And Cleaning.................................................................................12
Surface Cleaning.............................................................................................12
Seat Cleaning.................................................................................................12
Cleaning Nozzle..............................................................................................13
Removing Seat Cover......................................................................................14
Cleaning Filter Screen................................................................................15-16
Maintenance Before Left Idle For A Long Time..................................................16
Troubleshooting Guideline.................................................................................17
General Functions...........................................................................................17
Washing Functions.........................................................................................18
Close Control And Seat Sensor.........................................................................18
Seating Sensor................................................................................................19
Warm Air Drying Function...............................................................................19
Deodorizing Function.....................................................................................19
Other..............................................................................................................19
Specications.....................................................................................................20
Packing list............................................................................................................21
Product After-sale Service&warranty Card...........................................................22

34
SAFETY PRECAUTIONS
Warning – To prevent low temperature burn, electrical shock, re accident or human
body injuries.
· Children, the aged or disabled who are using or come closer to the Product must be closely
guarded, children should not be allowed to use or be exposed to the Product. Do not let the
children staying in the room equipped with the Product alone.
· For children and the aged users who are unable to adjust the temperature by themselves
independently, help them to adjust temperature of the seat, water and air to proper level.
· Do not allow the children playing about the device/equipment.
Caution for use:
· Be sure to install the Product correctly in compliance with instructions for/specication of
installation.
· The user must have the Product well grounded in accordance with the Instruction Manual
before energizing/power connection.
· Do not place any combustible objects on the product, e.g.: candle, glowing cigarette or
similar objects.
· Please do not use/operate the Product in any of following cases: power wires, plugs and the
Product is/are damaged; the Product is not working; the Product is dropped into the water.
· Do not use the Product outdoor or in an area where a particle spraying equipment is in
operation or where oxygen supply operation is ongoing.
· Be sure to use/operate the Product strictly in compliance with methods/instructions
specied in the Manual, never use accessories Coburg recommends not to use.
· Please ensure to use water inlet hoses and angle valves enclosed with the Product delivered
instead of any used hoses and angle valves.
· While using/operating the Product, do not lean your back over the cover to avoid any
damage of the Product.
· To keep the power wire away from any heating surface.
· Prevent water from splashing onto the power plug.
· Do not drop or insert any objects into the pipeline/openings.
· Please do not contact the heated seat by skin directly for long time to avoid low tempera
ture burn.
· The Product can only be repaired by authorized competent sta, never attempt to x/repair
the Product by yourself or you will lose your entitlement to the quality warranty service.
· In case of any broken power wires, for sake of safety, the User must contact and request the
manufacturer, its repair/maintenance department or equivalent department to assign
competent personnel to replace such broken wires.
SAFETY PRECAUTIONS
Important! Hazard of damaging the Product or other properties.
· Do not install the Product at where with potential exposure to splashing water.
· Do not install the Product at any place involving over-high humidity where moisture/wa
ter vapor might condensate on surface of the Product. Please keep the area where the
Product is/to be applied well ventilated to eliminate potential damage of electronic
elements/components.
· To push or pull water hose joint(s) by force violently might result in trouble of water
leakage.
· Do not apply force against the nozzle over than necessary or the Product might be
damaged.
· Please ensure to well insulate the water pipe as water contained in it might get frozen. Any
water staying in the Product might get frozen in winter, please be sure to heat the Product
up to ambient temperature prior to reinstatement or usage.
· Do not get power connected until completion of installation, otherwise, Product failure
might be encountered.
Note: In warm days, heat protector might be disabled in process of storage or transportation
resulting in failure of the Product. Please ensure to warm the Product up to ambient temperature
before reinstatement or operation.
While using electrical appliances, especially with presence of children, people
shall follow instruction of general safety precautions including:
Hazard – to reduce hazard of exposure to electrical shock:
· Do not put this equipment/device at any place/location where it might be dragged or
pulled unexpectedly and dropped into bath tube or water sink.
· Do not put it or let it dropping into the water or other liquid.
· Do not touch the Product dropped into the water, unplug it immediately instead.
Please keep the Instruction Manual in well custody!
CAUTION: TO PREVENT ELECTRICAL SHOCK, DO NOT DISASSEMBLED THE
SEAT. THERE ARE NO USER SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED SERVICE PERSONNEL.
Warning: Hazard of electrical shock, re or human body injuries. The Product
MUST be safely earthed/ grounded.
This Product is only allowed to be connected to electric circuit of AC
220-240V 50-60HZ and 10A, equipped with ground fault/failure breaker or
earth leak protector.
Warning: Hazard of getting electrical shock or damaging the Product. Do not
put the Product in the water.

6
QUICK START GUIDE
■Initial usage
Install the seat and plug in as per installation instructions. It will automatically initialize until
the night light ickers o.
■Normal usage
• Have seated
The deodorization function opens automatically, it can be stopped by press“Stop” key.
You can change the seat temperature to appropriate shift rst.
• After toilet
Select Female or Rear mode, adjust water pressure, temperature and nozzle position to
appropriate shift and then wait for ushing over, or you can stop the ushing by pressing
“Stop” key.
• After ushing
To enable Warm Air Drying function, adjust the appropriate shift.
• Leave away
It will enter standby mode automatically.
■Remote Control Unit Description
All features of the bidet can be controlled with the remote control.
STOP/AUTO: Press once for stop; Press and hold on 3seconds to enter automatic mode.
CHILDREN: Enter Children mode. ( For CBD1807)
ENEMA: Enter Enema defection. ( For CBD1808)
FEMALE/REAR PRESSURE: Press once to turn on Female or Rear mode, press again to
change the shift.
WATER TEMP.: Change the temperature of water
OSCILLATE/CLEAN: Turn on or o the oscillating clean function
NOZZEL POSITION: Adjust nozzle position
DRYER: To enable Warm Air Dying function
SEAT TEMP.: Change the seat temperature
DEODORIZER: Turn on or o the deodorization function
NGHT LIGHT: Turn on or o the night light
5
CONTROL PANEL
CBD1808 Control PanelCBD1807 Control Panel

7
USAGE/OPERATION METHOD
To enable Female Mode, with the user ready sitting on the seat, press the
“Female” key, current rinsing intensity will also be displayed and any
ongoing warm air blowing operation will be disabled promptly.
With the Female Mode enabled, press the Female key further will allow the
user to adjust/modify rinsing intensity for three shifts (Shift 1, Shift 2 and
Shift 3).
To enable Rear Mode, with the user ready sitting on the seat, press the “Rear”
key, current rinsing intensity will also be displayed any ongoing warm air
blowing operation will be disabled promptly.
With the Rear Mode enabled, pressing the Rear key further will allow the
user to adjust/modify rinsing intensity for three shifts (Shift 1, Shift 2 and
Shift 3).
To enable Children Mode, with the user ready sitting on the seat, press the
“Children”key, series steps of operation including rear rinsing for 2 minutes,
warm air blowing for 3 minutes and deodorization will be implemented
automatically with water pressure maintained at low level, water tempera-
ture at medium level (Shift 3) and nozzle at forward position.
To adjust water temperature, press the “+/-“ key and the user may adjust
water temperature for ve shifts (Shift 0, 1, 2, 3, 4 and 5).
To disable function of rinsing, air warming and deodorization, press the
“Stop” key.
To enable the Automatic Mode, press the “Stop”key and hold for a while
for CBD1807/CBD1808, series steps of operation including rear rinsing for 2
minutes, warm air blowing for 3 minutes and deodorizing will be
implemented automatically with water pressure, temperature and position
of the nozzle maintained at middle level.
To enable Defecation Enema Mode, with the user ready sitting on the seat,
press the“Defaecate” key and the body should be in a relaxed state, current
rinsing intensity will also be displayed any ongoing warm air blowing
operation will be disabled promptly.
8
USAGE/OPERATION METHOD
To adjust nozzle position in the Rear Mode or Female Mode, press the
“Nozzle position”key, it will allow the user to adjust nozzle position for three
shifts, i.e. forward shift, middle shift and rear shift, sequentially in circles.
To enable Warm Air Drying function, with the user sitting on the seat, press
the “Dryer” key. Further press on the key will allow the user to adjust air
temperature for three shifts, i.e. low, medium and high, sequentially in
circles.
To disable Warm Air Drying Function, press the“Stop” key.
To enable the Deodorization Function, press the “Deodorization” key, the
Diatomic Alcohol Deodorizing and Purifying Function will be enabled at the
same time (only in case of CBD1807/1808). Press the“Deodorization” key or
“Stop” key again, you will disable the Deodorization Function.
To adjust seat temperature, with the user sitting ready on the seat, press the
“Seat temp. control” key, it will allow the user to adjust the temperature for
four shifts, i.e. O, Low, Medium and High, sequentially and followed by
recycling.
*CBD1805 is not supported to adjust seat temperature. The method of
operation: turn on the power supply after turn o it for 5 secs rst, and then
turn the knob backward holding on 5 secs until heard the "DING" sound,
the seat temperature can be switch on/o.
With the Rear Mode or Female Mode enabled, press the “Oscillate Clean” key
and the user may change position of the nozzle forwardly or backwardly, press
the“Oscillate Clean”key again, the user may disable/stop“Oscillate Clean”.
To clean the nozzle, press the “OSCILLATE” key or press the “Cleaning” key
and hold for a while for CBD1807/CBD1808 after ipping up the lid and the
seat providing that there’s no one sitting on the seat, the nozzle will be
self-cleaned and extended out, you may clean the nozzle with soft bristle
brush then. Upon completion of nozzle cleaning process, press the “Stop”
key, the nozzle will be retracted backwardly or you may just wait for
automatic retraction operation.

9
USAGE/OPERATION METHOD
Instruction About Water Temp. Shift Conguration
Shift 2 (Medium and low shift)
Two indicators lights on.
Shift 1 (Low shift)
One indicator lights on.
Shift 0 (OFF)
No indicator lights on.
Shift 3 (Medium shift)
Three indicators lights on.
Shift 4 (Medium and high shift)
Four indicators lights on.
Shift 5 (High shift)
Five indicators lights on.
Instruction About Other Shift Conguration
Shift 2 (Medium shift)
Two indicators lights on.
Shift 1 (Low shift)
One indicator lights on.
Shift 0 (OFF)
No indicator lights on.
Shift 3 (High shift)
Three indicators lights on.
To enable the Night Light Mode, press the “Night Light” key, and press the
“Night Light” key again to turn o the the Night Light Mode.
One-key Knob
Turn the knob forward once to start the Female Mode. during the Female
Mode process, continue to rotate forward and adjust the washing intensity
circularly. Turn the knob backward once to start the Rear Mode, continue to
turn backward during the Rear Mode, and adjust the washing intensity
cyclically. Press the button in the middle of the knob for a short time to stop
the cleaning, drying or deodorizing functions. Press once long to activate
the Warm Air Drying function.
10
PREPARATION PRIOR TO INITIAL USAGE/OPERATION
· Connect water supply hose, open check valve and plug in as per installation instructions.
· Once the extension cord is plugged into the power socket, the bidet will send out a short
buzzing, the injection nozzle will extend out and retract back for once, nozzle self-cleaning
run for once and the night lamp will keep ashing till end of initiation process.
· During initialization, sounds of operating motor and owing water can be heard, which are
considered as normal conditions.
· Initial operation of the Product will be run against default settings:
Water temperature: Medium
Seat temperature: Medium
Warm air temperature: Medium
Night lamp function: Enabled
Energy saving mode: Disabled
Female Mode:
· Water ow intensity: Medium
· Nozzle position: Middle
Rear Mode:
· Water ow intensity: Medium
· Nozzle position: Middle

12
MAINTENANCE AND CLEANING
■ Seat Cleaning
· Make sure that your aerosol canister does not contain
abrasive detergent and disinfector.
· Exposure to corrosive chemicals or cosmetics (e.g. nail
polish or aftershave lotions) is forbidden as it will damage
surface of the seat.
Tips for maintenance: clean the seat with water and
detergent mixture or other cleaning products deemed
acceptable for cleaning seat with soft and wet sponge or rag,
then, wipe with soft towel and leave it in the air for natural
drying.
Note:
· Failure to follow any of these cleaning instructions might
jeopardize your entitlement to quality warranty service.
To ensure best performance of the Product, it is critical to remember following
precautions listed as below while maintaining the Product.
Important! Don’t ush the bidet with water directly.
· Eectiveness of the cleaning process is subject to several contributors including hardness
and temperature of water used, accurate dosage of detergent, change of cleaning rules and
condition of the cleaned, which may vary or change over time, therefore, Coburg makes no
guarantee to eectiveness of cleaning instructions mentioned above.
■Surface Cleaning
· Test: Before applying liquid detergent to clean entire
surface of the bidet, test it at inconspicuous place for a
small area and make sure it would not cause damage to
the lid.
· No soaking in the detergent: Don’t soak the bidet in the
detergent.
· Avoid using cleaning tools/devices with rough contact
surface, be sure to use soft and wet sponge or rag instead
of those with rough contact surface such as brush or
scouring pad to clean the surface.
· Wipe-Wipe the surface immediately after application of
detergent with wet rag to remove any dirt and the
detergent o the surface.
Rag
Abrasive
Corrosive
11
FUNCTIONAL TESTS
· Cover the seat with plastic membrane to protect it from eect of any water injected out of
bidet during a test.
· The seat is designed with seating sensing. To activate the seat for this functional test, face
the bidet and put your hand(s) or a piece of wet rag in detectable area on the right side
keeping a distance equivalent to 1/3 of rim length from its front end.
· Proceed to perform test on dierent functions according to specication contained in
Section “Control Panel” and “Usage/Operation Method”.
detectable area

14
■Remove Seat cover
· Close water supply valve
· Enable washing function of the bidet to depressurize the water supply pipe
· Unplug the power
· Disconnect water supply pipe and tees.
· Press and hold on the“Release”key (shown in the gure)
· Keep moving the bidet forwardly till the lid is detached from the mounting plate.
MAINTENANCE AND CLEANING
Mounting plate
Release key
13
■Cleaning Nozzle
· Flip open the lid and seat.
· Press the“Sterilization”key and hold for a while till tube of the nozzle is fully extended,
then clean the nozzle with a soft bristle brush.
· After the nozzle is cleaned, press the“Sterilization”key and hold for a while till the nozzle
tube retracts, or just wait for it.
Note: The nozzle can only be extended out for cleaning purpose when there’s no user sitting
on the seat.
Nozzle in extended positions
MAINTENANCE AND CLEANING

1816
Filter screen
Nipper pliers
■
MAINTENANCE OF THE PRODUCT LEFT IDLE FOR A LONG
TIME
· If the Product is to be left idle for a long time, unplug the power, close the angle valve,
disassemble the water supply hose and drain it o.
· Before using the Product that has been left idle for a long time again, please perform several
cycles of rinsing till the internal pipes are thoroughly cleaned.
MAINTENANCE AND CLEANING
15
■Cleaning Filter Screen
Note: Important! Hazard of damaging the Product. Be sure not to cause any damages to
joints/connections.
Please clean or replace lter screen promptly if you notice that the water ow is decreasing
or there’s no water ow.
· Close water supply valve.
· Press the“Release”key and keep moving the bidet forwardly till it’s detached from the
mounting plate.
· Rotate the water supply pipe to remove it out of the pedestal.
· Disassemble the water supply pipe.
· Take the lter screen out through the water inlet port carefully with help of nipper pliers (As
shown in gure).
· Clean the lter screen with a soft bristle brush.
· Reinstate the lter screen.
· Reinstate the water supply pipe properly by ensuring alignment of threads carefully.
· Check all the connections and joints and make necessary adjustments to prevent any
leakage.
· Open water supply valve.
MAINTENANCE AND CLEANING

1817
TROUBLESHOOTING GUIDELINE
Troubleshooting guideline contained herein is intended to help solving common problems.
For electrical problems, please contact authorized service representative of Coburg for
solution. For services as part of quality warranty, please contact your dealer or wholesaler.
■ GENERAL FUNCTIONS
Problems Possible causes Recommended actions
1.The machine
fails to work
2.Remote control
no response
3.No water ow
out of the nozzle
tube
4.Night lamp
is not on
5.The seat seems
not as warm as it
should be.
A.The power is o
B.The power supply is disconnect-
ed
C.Earth leakage circuit breaker for
extension cord is not reset.
D. The user is staying out of the
detectable area of seat.
E.Automatic protection is enabled
by the thermal protector.
F.All the above actions fail to work.
A. Wait for restoration of power.
B.Plug the extension cord into the
socket
C.Press the reset button on the
plug.
D.Stay in detectable area of seat.
E.Leave the Product under
ambient temperature for a while
F.Contact service representative
of Coburg.
A.Low battery.
B.All the above actions fail to work.
A.Replace new button battery
CR2032.
B.Contact service representa-
tive of Coburg.
A.The seat fails to detect the user.
B.The water supply valve is closed.
C.The lter screen is blocked.
D.All the above actions fail to work.
A.Adjust your seating position
and ensure there’s nothing, such
as your pants, separating your
skin from the seat.
B.Power o the equipment, solve
the water supply trouble and
power on again.
C.Refer to the Section“Cleaning
Filter Screen”
D.Contact service representative
of Coburg.
A.Considerable ambient light
B.The night lamp function is
disabled.
A.Check if the night lamp is on
by dimming ambient light.
B.Press“Night light ”to swith on
the night light.
A.The Rim Heating function is
disabled.
B.In order to prevent low tempera-
ture burn, the temperature of the
seat is reduced 1°C every 10
minutes.
A.Set the temperature as per
instructions contained in this
Manual.
B.It is considered as normal
condition. You can have seat
again.
TROUBLESHOOTING GUIDELINE
■CLOSE CONTROL AND SEAT SENSOR
Problems Possible causes Recommended actions
11.The closing
speed of seat and
lid in summer is
dierent from
that in winter.
A.It is caused by change of room
temperature. A.It is considered as normal
condition.
12.With no user
sitting on the seat,
pressing the
“Washing”key will
enable the
Washing function.
A.Seating sensor is covered by an
object or the seat is wet. A.Wipe water or foreign matter
out o the detectable area.
Problems Possible causes Recommended actions
6.There is no
water ow.
A.Water supply valve is closed.
B.Seating sensor fails to detect the
user.
A.Open water supply valve.
B.Refer to instructions contained
in section“Function Tests”on
how to activate seat.
7.Low pressure
of rinsing water
A.Filter screen is blocked.
B.Inadequate pressure of water
supply.
A.Refer to the section“Cleaning
Filter Screen”
B.Increase the water pressure to
range required by the Product
8.No further
water owing
out of the nozzle
before the washing
is completed
A.The“Washing”function is disabled
automatically after continuous
washing of ve minutes.
B.The seating senor fails to detect
the user.
A.Press the“Washing” key once
again if necessary.
B.Refer to instructions contained
in section“Functional Tests”on
how to activate seat.
A.It results from the protection
function which is designed to
protect against overpressure of
water in the product.
A.It is considered as normal
condition.
10.There’s water
owing from the
nozzle when the
user sits on the
bidet.
A.The Product will automatically
drain o any residual water in the
nozzle tube after being left idle
for a long time before reusing.
A.It is considered as normal
condition.
9.There’s water
owing out of the
hole by side of the
nozzle during
washing
■WASHING FUNCTIONS

19
■SEATING SENSOR
Problems Possible causes Recommended actions
13.Washing
function fails to
work even if
there’s user sitting
on the seat.
A.The seating sensor fails to detect
the user on his/her current sitting
position. A.Change your sitting position .
■DEODORIZING FUNCTION
Problems Possible causes Recommended actions
15.Deodorizing
fan is not
functional.
A.The“Stop”key is pressed
unexpectedly. A.Press the“Deodorization”
key once again.
■OTHER
Problems Possible causes Recommended actions
16.Loosened bidet A. Screws on the mounting plate
which xes the Product in place
are loosened.
A.Tighten the screws on
the mounting plate.
■WARM AIR DRYING FUNCTION
Problems Possible causes Recommended actions
14.The warm air
dryer stops
running in process
of usage/opera-
tion.
A.The warm air dryer will stop
automatically after it’s running
out of time set, i.e. 4 minutes.
A.Press the“Warm Air”key
once again.
20
SPECIFICATIONS
Check valve
Water supply pressure
(dynamic pressure)
Power 220-240V~50/60Hz
Extension cord length Approx.1.6m
Overall size 525mmx396mmx157mm
Weight approx.4.5Kg
Ambient Temperature 1-40°C
Rear mode
Water
flow Female mode
Rated heating power 1325W
Water temperature adjustment O, 1-5 shift
(ambient temperature, approx 31 to 39°C)
Rinsing time (single operation, max) 300s
Nozzle quantity One
Nozzle position adjustment Three positions
Mobile rinsing On/O
Safety
device
Overheat protection
Back ow prevention
Thermal fuse, overheat cut-o
Seat
heating
Temperature
adjustment
Safety device
O, 1 to 3 position
(ambient temperature, approx. 31 to 41°C)
Thermal fuse, overheat cut-o
Lid Slow lowering
Slow lowering
Seat
Temperature adjustment
O, 1 to 3 position (ambient temperature, approx. 32~48°C)
Safety device
Diatomic alcohol deodorizing function
Electrolyzed water sterilization
Warm
air drying
Nozzle self-cleaning
Quick disassembly of main body
Antibacterial material
Knob
Remote controller
Seating sensing
Thermal fuse, overheat cut-o
Available
Available for CBD1807/1808
Available for CBD1805/1807/1808
Only available for CBD1807/1808
Only available for CBD1808
By pushing the “Release” key
Seat and lid
Available
Inside the seat
Approx.450-850ml/min
Approx.450-850ml/min
Cleaning
Sanitary
Comfortable
Other
functions
0.8kgf/cm²(dynamic pressure)
-7.5 kgf/cm²(static pressure)
(0.08MPa.t(dynamic pressure )
-0.75MPa.(static pressure))
2 blue LED lampsNight lamp
TROUBLESHOOTING GUIDELINE

21 22
1.TheWarranty Policy for the Product is: one year for replacement, two years for warranty .
2.Any malfunction or failure of the Product resulting from normal operation and application
according to the User’s Manual (which shall be subject to judgement and verication by regular sta
of the Company) duringWarranty Period will be xed and repaired by us free of charge.
3.In any of following cases during the Warranty Period, we may provide repair services by charging
relevant repair fee.
(1)Can not provide this guarantee, valid purchase certicate and the machine only two-dimension-
al code serial number.
(2)Failure of or damage to the Product caused by the User due to his/her improper operation or
application or authorized repair activities.
(3)Failure of or damage to the product due to rough transportation, handlingor falling after its
purchase.
(4)Damage to the Product caused by water or other solutions entering into the Product due to improper
operation.
(5)Damage to the Product caused by the user’s failure to use designatedpower supply or voltage.
4. Appearance of the Product, its vulnerable and consumable parts and accessories are not covered
in the warranty scope.
PRODUCT AFTER-SALE SERVICE&WARRANTY CARD
PACKING LIST
Part name
Bidet Seat
Installation guide
Product Manual and Certicate
* Assembly of remote controller
Quantity
* Attachment of remote controller
Attachment of Installation
( T-Valve、water inlet、installation bolts、installation nuts、
installation board)
Assembly of Installation
Assembly of lter
Note: The parts with * are optional, please erfer to the actual situation while there are any
discrepancies.
This manual suits for next models
2
Table of contents
Popular Toilet manuals by other brands

Fisher-Price
Fisher-Price BMM08 manual

Swiss Madison
Swiss Madison SM-STS31 installation instructions

Drive DeVilbiss Healthcare
Drive DeVilbiss Healthcare TSG 130 Instructions for use

Tecma
Tecma EasyFit Eco Owners and installation manual

Geberit
Geberit AQUACLEAN MERA COMFORT user manual

DURAVIT
DURAVIT SENSOWASH 610001 operating instructions

Propel Trampolines
Propel Trampolines Tornado V2 installation guide

Dudley
Dudley Resan Vandal Resistant Urinal Fitting instructions

American Standard
American Standard EQUIX Series installation instructions

Laufen
Laufen LEMA H841192 installation instructions

Laufen
Laufen ILBAGNOALESSI ONE 8.2697.1 manual

Kohler
Kohler K-3900X-2 installation guide