manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cognex
  6. •
  7. Measuring Instrument
  8. •
  9. Cognex DataMan 7500 Series User manual

Cognex DataMan 7500 Series User manual

COGNEX
DataMan™ 7500 Series Handheld Verier
Quick Reference
1
7500 Series Verier Kit Contents
DataMan™ Verier Calibration Card
CALIBRATION
TARGET
Instructions:
1. Center calibration
target in the eld
of view
2. Depress and hold
reader trigger until
calibration routine
is complete
Lot Number 20061102
COGNEX
7500 verier stand-off
Calibration card
(stored in protective sleeve)
This document
Data Matrix Symbol Quality Verication
Cognex DataMan 7500 Series handheld veriers ensure that a Data Matrix
symbol meets the AIM DPM (Direct Part Mark) Quality Guideline.
The DataMan 7500 Series handheld veriers provide:
Contract Compliance: The DataMan 7500 Series software, integrated
lighting, and xed optics meet the AIM DPM Quality Guideline.
System Calibration: The DataMan 7500 Series verier includes a certi-
ed calibration card necessary to calibrate the reader.
•
•
If you are upgrading an existing DataMan 7500 series reader to use as a
verier, your reader must be using rmware version 2.1.1 at a mini-
mum. To update the rmware:
Connect your reader to the DataMan Setup Tool.
Choose System->Update Firmware.
Select the le DM7xx0_v2.1.1_rc1.bin.gz from the directory
Cognex\DataMan\Firmware\DM7500 Series.
To enable the DPMV feature, you must upload a feature key le to the
reader:
Connect the reader to the DataMan Setup Tool.
Choose System->Upload Feature Key
Select the feature key le that you receive from Cognex.
Disconnect the reader from the DataMan Setup Tool.
Perform a soft reset of the reader by scanning the Soft reset symbol
on the back of the 7500 Series ID Reader Quick Reference.
1.
2.
3.
1.
2.
3.
4.
5.
Refer to your 7500 Series ID Reader Quick Reference for information on initial
setup and establishing communication with the reader itself.
3
Getting Started: Stand-off Installation
Attach the stand-off to your DataMan 7500 Series reader.
Getting Started: Calibration
Start the DataMan Setup Tool and connect to your reader.
Select the Code Quality Settings task pane.
Place the verier against the calibration card with the symbol
centered below the reader, and squeeze the trigger.
1.
2.
3.
Continue squeezing the trigger. Calibration can take several seconds.4.
The Setup Tool displays a graphic guide if the symbol is not precisely
aligned with the reader; adjust the position and rotation of the reader
until the center of the red rectangle lies within the green rectangle and
there is no more than 10 degrees rotation between the symbol and the
reader. The reader beeps once when calibration is complete.
5
Code Quality Verication Code Quality Results
Move the reader until the center of the red rectangle lies within the green
target rectangle. The reader beeps to indicate that the symbol has been
read and veried.
5.
The Results Display task pane presents the results of the verica-
tion on the right-hand side.
For more information on interpreting the verication results, select
View->Q+A Help. The Results Display task pane can toggle between
displaying results or Q+A information.
Overall verication result (Pass/Fail)
Individual AIM/DPM metrics and grades
Process control metrics (if enabled)
Select the Results Display task pane.
Place the verier against the symbol and squeeze the trigger. The symbol
must be centered within the eld of view, and the reader must be perpen-
dicular to the surface containing the symbol and at the correct rotation. If
the reader is out of position, the Setup Tool displays this guide:
3.
4.
Start the DataMan Setup Tool and connect to your reader.
Enable the Turn Code Quality On icon in the tool bar.
1.
2.
In order to perform Direct Part Mark Verication your reader must be
calibrated as described in the previous section. To read symbols and view
verication results, perform the following steps:
The verier stand-off must be used to ensure correct symbol presentation
and lighting requirements for the AIM DPM Quality Guideline.
7
Code Quality: Formatting Output Data
Use the Data Formatting task pane of the DataMan Setup Tool to construct
a customized output string each time you read and verify a symbol. This
allows the verier to return Code Quality results when connected to a third-
party application instead of the DataMan Setup Tool.
In addition to standard formatting, the DataMan Setup Tool supports the
use of Perl-Style Regular Expression features in Advanced mode.
Code Quality: Logging Data
Use the Data Logging task pane to generate a Code Quality Report for
each symbol that you read and verify. Be aware that data logging works
only when the reader is connected to the DataMan Setup Tool.
In addition, you can enable the Prex lename with option to give each
Code Quality Report a set prex.
Select View->Advanced if the DataMan Setup Tool is not in Advanced
mode.
Select the Data Logging task pane under System Settings.
Enable Code Quality Results and use the Save in option to cong-
ure a directory location to save each report along with an image of the
veried symbol, as shown in the following example:
1.
2.
3.
9
Verication Conguration: Saving the Setup
Once you have congured your reader with the settings you want it to use,
choose System->Save Settings to save the conguration.
Choose File->Save Conguration to save the conguration to a directory
on the PC. A saved conguration can be opened later and uploaded to any
reader, allowing multiple readers to use the same conguration settings.
Be aware, however, that each reader must be calibrated individually.
Code Quality Conguration Codes
Use the following Code Quality conguration symbols to quickly turn
Code Quality on and off without connecting the reader to the DataMan
Setup Tool. Additional Code Quality Reader Conguration symbols are
available in the online documentation.
Code Quality On
Code Quality Off
Code Quality Configuration Codes (v2.1)
1 / 1
Function Value Code
Code Quality On
*Code Quality Off
*Illumination East-West
Illumination North-South
Code Quality
Settings
Illumination All
Code Quality Configuration Codes (v2.1)
1 / 1
Function Value Code
Code Quality On
*Code Quality Off
*Illumination East-West
Illumination North-South
Code Quality
Settings
Illumination All
COGNEX
Copyright © 2007 Cognex Corporation All Rights Reserved.This document may not be copied in whole or in part, nor transferred to any
other media or language, without the written permission of Cognex Corporation. The hardware and portions of the software described
in this document may be covered by one or more of the U.S.patents listed on the Cognex web site http://www.cognex.com/patents.
asp.Other U.S. and foreign patents are pending. Cognex, the Cognex logo, and DataMan are trademarks, or registered trademarks,of
Cognex Corporation.
590-7031

Popular Measuring Instrument manuals by other brands

Piusi K24 Use and maintenance manual

Piusi

Piusi K24 Use and maintenance manual

Festo Measuring Pro 400 Series operating instructions

Festo

Festo Measuring Pro 400 Series operating instructions

Precision Digital Corporation PD685 instruction manual

Precision Digital Corporation

Precision Digital Corporation PD685 instruction manual

ENMET ISA-40 Series manual

ENMET

ENMET ISA-40 Series manual

Veeder-Root Mag-FLEX installation manual

Veeder-Root

Veeder-Root Mag-FLEX installation manual

Meinberg IMS-MDU312 manual

Meinberg

Meinberg IMS-MDU312 manual

R.M. Young 27106T quick start guide

R.M. Young

R.M. Young 27106T quick start guide

SENSIRION Nubo Sphere user manual

SENSIRION

SENSIRION Nubo Sphere user manual

Landis & Gyr ULTRAHEAT T230 Operating and installation instruction

Landis & Gyr

Landis & Gyr ULTRAHEAT T230 Operating and installation instruction

Signal Hound USB-SA124B user manual

Signal Hound

Signal Hound USB-SA124B user manual

Emerson Daniel 3812 installation manual

Emerson

Emerson Daniel 3812 installation manual

Bartec Auto ID TECH500 user guide

Bartec Auto ID

Bartec Auto ID TECH500 user guide

Guardian Safety Pendants MediFone user guide

Guardian Safety Pendants

Guardian Safety Pendants MediFone user guide

Campbell HMP60 instruction manual

Campbell

Campbell HMP60 instruction manual

PCB Piezotronics 354B21 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 354B21 Installation and operating manual

Hanna Instruments C 216 instruction manual

Hanna Instruments

Hanna Instruments C 216 instruction manual

Orbit Merret OMM 37 manual

Orbit Merret

Orbit Merret OMM 37 manual

Thales KPG-opt 4FSM-IN Product information

Thales

Thales KPG-opt 4FSM-IN Product information

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.