manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Colorbeam
  6. •
  7. Lighting Equipment
  8. •
  9. Colorbeam Coloray Line 48II User manual

Colorbeam Coloray Line 48II User manual

Popular Lighting Equipment manuals by other brands

Life 39.9F70020C quick start guide

Life

Life 39.9F70020C quick start guide

EuroLite LED ML-20 user manual

EuroLite

EuroLite LED ML-20 user manual

LIGMAN OD-50141 installation manual

LIGMAN

LIGMAN OD-50141 installation manual

Home Accents Holiday 1002461144 instructions

Home Accents Holiday

Home Accents Holiday 1002461144 instructions

Experia IRiS Ripple Light instruction manual

Experia

Experia IRiS Ripple Light instruction manual

Erco Gecko Mounting instructions

Erco

Erco Gecko Mounting instructions

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Inter-lux

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Whelen Engineering Company TN Series installation guide

Whelen Engineering Company

Whelen Engineering Company TN Series installation guide

IKEA BJÖRKSPIREA manual

IKEA

IKEA BJÖRKSPIREA manual

Toolland PM 6640 instruction manual

Toolland

Toolland PM 6640 instruction manual

GTD GTD-LP200 user manual

GTD

GTD GTD-LP200 user manual

LIVARNO home 1105-W-UK manual

LIVARNO home

LIVARNO home 1105-W-UK manual

ProLights EclPar IPMFC user manual

ProLights

ProLights EclPar IPMFC user manual

Velvet EVO Series user manual

Velvet

Velvet EVO Series user manual

IDTOLIGHT GENT installation instructions

IDTOLIGHT

IDTOLIGHT GENT installation instructions

MAYTONI S35 installation manual

MAYTONI

MAYTONI S35 installation manual

MaxLite MLFP14DP4535 user manual

MaxLite

MaxLite MLFP14DP4535 user manual

SLV Elektronik 550621 instruction manual

SLV Elektronik

SLV Elektronik 550621 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Coloray Line 48II User manual
Version: 2.0
USER MANUAL FOR LED Coloray Line 48II
1
Important
Damages caused by the disregard of this user manual or unauthorized modification
to products are not subject to warranty
Please make sure that there are no obvious transport damages. Please immediately
contact the local dealers as the fixture is in fault operation or damage.
Always plug in the power plug last. The power plug must always be inserted with force.
Make sure the plug is tightly connected with outlet.
If extension cords are used make sure that the core diameter is sufficient for required
power consumption of the device. All warnings concerning the power cords are also
valid for possible extension cords.
Do not block any of ventilation openings.
Do not open the fixture and try to repair the fixture personally.
2. OPERATION DETERMINATIONS
The device must only be used indoor.
If the unit has been exposed to drastic temperature, do not switch it on immediately.
1. SAFETY INSTRUCTION
Every person involved with installation and maintenance of the this device has
to :
-be qualified.
-following the instructions of manual
This device has left our premises in absolutely perfect condition. In order to maintain
this condition and to ensure a safe operation, it is absolutely necessary for the user
to follow the safety instructions and warming note written in this manual.
CAUTION!
Keep this driver away form ra in and moisture
Unplug mains lead befo re opening the housing
Read the instructions care fully before you install start -up!
CAUTION!
Be careful with your operations.
You can suffer a dangerous electric shock when touch the wires inside
the unit.
Description of Coloray Line 48II
2
3 PinXLR DMX connector
Safety ring
AC input
100~240V
50/6 0Hz
DMX setting
The arising condensation water might damage your unit. Leave the unit switched off
it has reached room temperature.
Only operate the unit after having checked the housing is firmly closed and all screws
tightly fastened. Do not shake the device. Avoid brute force when installing or operating
the device.
Operate the device only after having familiarized with its functions. Do not permit
operation by persons not qualified for operating the device.
Most damages are the result of unprofessional operation!
The maximum ambient temperature 40 degree must never be exceeded.
Please consider that unauthorized modifications on the device are forbidden due to
safety reasons!
3
Unplug form the mains before installation
Fix the fixture with bracket
Connect the AC power cord to the socket
4. SIGNAL INDICATORS
Receive DMX signal: the green light emitting diode shows when the lighting
fixtures receive DMX signal.
Receive Master signal: the green light emitting diode shows when the lighting
fixture are set Master
3. INSTALLATION
AC input
100~240V
50/60Hz
DMX IN/O UT
3 PIN XLR
AC input
100~240V
50/60Hz
4
2. Fixed color
Fixed color: there are 20 built-in fixed colors in the CD-65II
Press Menu. The display shows C01
Press up and down to select the desired color from C01~C20
3. Fade program
Fade program: there are 9 built-in fade programs in the CD-65II
Press Menu. the display shows F01
Press up and down to select the desired program from F01~F09
The fade time of program can be changed from 01~99%(0.5~50sec).
E.g:F03 is running. The fade time can be change by press menu and hold for 3 sec.
The display will show S---- The fade time can be adjusted to 01~99%.by press
Up and down and press Menu again to confirm.
4. DMX Mode setting: the following mode can be selected by press menu to confirm it.
Press Menu. the display shows S---
Press up and down to select the desired program from S01~S41
Press menu again to confirm it.
S10: Control all of LED fixtures in the same channel (default).
S11: Control all of LED fixtures independently
S20: Master off (default).
S21: Master
S30: RGB 3 channels (default).
S31: RGB dimming, strobe 5 channels
S40: Delay off (default).
S41: Delay on
NOTE: the function of delay on is designed for running slow, and free-fliker program.
The response speed of LEDs is slower than normal.
All drivers must be set on the same mode( delay on or off) as connecting
together ,otherwise, the program does not run synchronously.
The slave drivers must be set add. 001 when running Master/Slave function.
1.DMX add. Setting
5. OPERATION 001001
C01C01
F01F01
S-S- Me n u
Add.
Color
Fade
Set --
MenuMenu UpUp
DownDown
DMX Address: press Menu. the display shows the initial DMX address.
Press up and down to select the desired address from 001-512
Coloray Line 48II
Electrical:
Power requirement: 100-240VAC, 50-60HZ
Power consumption: 48W at full intensity
Meets CE safety standards
Source & Optics:
LEDs: 16 x 1W Red/ 16 x 1WGreen/ 16 x 1W Blue
Lens Beam Angle: Standard 25 degree
Life time: estimated 100,000 hours when color changing
Total Lux (3M): R580 G 960 B55 W1150
Communication:
DMX512(1990): RGB 3 channels
Environment:
Operating temperature: -10~40 degree
Housing:
Finish: Metal body in black color
Dimension(mm): L1071 x W 60.6 x H 35.9
Weight: 4Kg
Protection: Ip20
6. Technical Specifications of Lighting Fixtures
5
1070
122.80
60.60
Dimension(mm):
6
ColorBeam CO., LTD
Room 416, 4F.,No.83-5 - Minguang E. Rd., Taoyuan 33052
,
Taiwan
TEL: +886 3 3357716 FAX: +886 3 3313386
E-mail: sales@colorbeam.com Website:www.colorbeam.com