Colordreamer Titan A8 Pro User manual

Products and specifications are subject to change without notice
Pixel Driver 1200
Titan A8 Pro
Client
Project
Order Code
QTY
TITAN A8 Pro
Thank you for purchasing the Colordreamer Pixel Driver 1200!
Our manual will describe the installation and mounting of the product as well as
description of how to use it.
Please read and understand this manual in its entirety before using the product.

Products and specifications are subject to change without notice
Package Contents:
1XTitan A8 Pro
1XPower Cord
1XRJ 45 Cable
1XThis Technical Manual
Product Warranty is void if product is not installed as per installation instructions and in
compliance with all local and provincial codes.
SAFETY RECOMMENDATIONS AND WARNINGS
Only use this device in dry environments (indoor use)
Do not make modifications or alter the product
Keep away from flammable material.
Do not use any silicone or other chemicals on outside surface.
Do not use chemicals or abrasives to clean the device as this many voids the warranty.
Ensure installation complies with local electrical rules and regulations.
Ensure mains input power is surge protected
Do not connect or disconnect the device while the power is connected.
Connectors are to be kept clean and dry at all times.
Input Voltage range 90-132VA/180-264VC by switch
Power off the device during service or when not in use.
Twisted pair cable is recommended for data transmission
Avoid unwanted voltage on the DMX cables at all times.
Do not remove any parts from the unit including the plug ground pin or connect to an
ungrounded circuit.
Do no connect the unit to LEDs that are switched on.
To supply this unit with power, first connect the provided power cord to the unit and then to
a suitable power outlet.

Products and specifications are subject to change without notice
Product Overview
Pixel Driver 1200 Titan A8 Pro is an eight universe Artnet to DMX driver designed for any DMX
Pixel Products. It has an integral 1200W 24VDC power supply for up to eight outputs based
upon eight universes received via Art-Net
Each output can provide maximum 150W+512DMX channels to LED Fittings.
Adjust settings and address via the onboard oled screen menu or web browser.
Perfect synchronization between each Universe.
Take full advantage of pixel mapping and voxel mapping, easy to install.
The Artnet controller device is ready within seconds after start-up. An HTP Merge is
automatically available for two Art-Net sources. If required, you can access and change
specific device settings using the built-in web configuration tool.
Product Specification
Models TITAN A8 Pro
Electrical
Input Voltage 90-132VA/180-264VC by switch
Power Consumption 1200W
(8 Output, Max 150W for each output)
Control
Network Protocols Art-Net via ethernet
Outputs DMX+24VDC
Ethernet RJ45
Default IP 192.168.1.100
Default Subnet 255.255.255.0
Physical
Housing Material Aluminium
Finish Color Black
Connector Removable Multi-pin terminal blocks
Dimensions(LXWxH) Body 440×300x88mm
Dimensions(LXWxH)Brackets
483×300x88mm(2U)
Weight
Environment
Operating Temperature -10℃ to +50℃
Storage Temperature -20℃ to +70℃
Humidity 0-80% non-condensing
IP Rating Dry, Indoor IP20
Certification CE
Warranty 2Years Limited Warranty from the Date of Manufacture
Contact us if you need extended warranty

Products and specifications are subject to change without notice
Dimension

Products and specifications are subject to change without notice
Connectivity
(Titan A8) H
A B C D E F E G
J
A: LED Outputs B: Oled Screen
C: Push/Dial button D: Reset Button
E: Status LED for Ethernet Link F: RJ45 Ethernet in Port
G: RJ45 Ethernet thru port H: Status LED for Ethernet Activity
J: Power Socket
Description of Status LED:
E: Status LED for Power
Status Description
Powered Off Power cable not connected. The device has no power
Permanently Green: Connected to Power. Power is on.
D: Status LED for Ethernet Link
Status Description
Powered Off Ethernet not connected

Products and specifications are subject to change without notice
Permanently Red: Connected to ethernet
F: Status LED for Ethernet Activity
Status Description
Powerer Off No data received over ethernet
Permanently Green or
Blinking Green
Communicating over Ethernet. Receiving data over ethernet
4PIN
Connector
Layout

Products and specifications are subject to change without notice
Device Configuration Through onboard Screen and Push/Dial
button
Standby Screen:
When you are not performing a task within a menu, Titan A8 Pro will display
device information as below.
Press and release the rotary dial to enter the Device
Configuration Menu.
Rotate the dial clockwise or counterclockwise to move between the highlights.
Press and release the dial to enter the page of highlight

Products and specifications are subject to change without notice
Rotate the dial to move the highlighted cursor between options within the page
When the highlighted cursor is over the required option, press and release the dial
Rotate the dial to change the value of the option.
Press and release the dial to fix the chosen value of the option.
Remember to press “OK&SAVE” to confirm your setting.
Press “Exit” to come back Main Menu.
Notes:
1: In the page “Set Port Address”, Sync Set can be Art-Net 3 or Art-Net 4
2: User can use Color Test Page to test your led fitting when software is not ready.
Color DepthW/RG/RGB/RGBW
R: a value between 0-255 G: a value between 0-255
B: a value between 0-255 W: a value between 0-255

Products and specifications are subject to change without notice
Device Configuration Through a Web Browser
You can access all settings and information of Titan Artnet Controller by using the built-in
web configuration tool.
Step 1) Connect Titan Artnet Controller and your computer to the same network.
Artnet Controller Default IP 192.168.1.100
Step 2) Assign correct network settings for your computer in the operating
system. (Recommended default settings:
IP address 192.168.1.XXX/ Subnet mask 255.255.255.0)
Step 3) Open your web browser and enter the IP address of Artnet Controller
192.168.1.100
Step 4) The web configuration tool will be launched.
Step5)You can change IP address and save this configuration

Products and specifications are subject to change without notice
Step6)After saving all setting,reboot the system to apply the new setting.after reboot,this
window will be closely automatically.
Reset to Factory Default Settings
Step 1) Disconnect the device from power.
Step 2) Use a suitable tool to press the reset button.
Step 3) Continue to press the reset button and connect to power again.
Step 4) Continue to press the reset button and wait until all status LEDs of the device flash
repeatedly or wait 5 seconds.
This manual suits for next models