STATIC Connection
With STATIC connection –you will manually set an IP Address and Subnet Mask Address for
the scanner and for your PC
-The PC and Scanner must be configured for sequential Static IP Addresses and both must
be configured for the same Subnet Mask number
-
For example –Set Scanner to IP address –192.168.001.111 -
Set PC to IP address - 192.168.001.112
Set both Scanner and PC to Subnet Mask of –255.255.255.0
Manually enter a Static IP address –then press
Manually enter a Static Subnet Mask address –then press
STARTING A SCAN TO PC (NETWORK)
1. Load a Document into the scanner
2. At scanner Display Panel –choose - setup your scan –then press
-
NOTE: If you encounter a problem - You may have to restart the Scanner and/or reboot PC –
so they can see each other –and try the Scan to PC once again !