• Read these instructions carefully before installation
• Must be installed by a trained and experienced technician
• Make sure you have turned o the power before doing
anything
Precautions

4 5
3x AAA batteries
19.5
COMPATIBILITY INSTALLATION
The new smart thermostat solution from COMAP is compatible
with most heating systems.
On/O
contact
Control
wire
Gas heating
Oil heating
Wood heating
Heat pump
Electric heating (dry contact)
Electric heating (control wire)
Check your compatibility at www.comapsmarthome.com
CONTENTS OF THE PACKAGE
Screws and dowels
1x thermostat
1x RJ45 cable
1x USB cable
1x heating module 1x gateway
The thermostat
is attached to the
wall in a living area
(e.g. the living room)
The three devices communicate with each other via radio waves (868MHz). The maximum
distance between the gateway, the module(s) and the thermostat depends on the structure
of your home (thickness of walls and building materials used) and the radio environment
(presence of high-voltage power lines, overhead wires, devices that transmit radio waves). As
an indication: in a new building in an urban environment, a distance of 30 m can be achieved.
Connect the
gateway
to the modem
The heating module
is connected to the
heating system
1 2 3

6 7
19.5
If there is a disconnection problem, bring the thermostat within 10 cm of the
heating module and then restart the thermostat.
In the event of communication problems:
• Disconnect the gateway from the modem and reconnect it; the two gateway LEDs
must be permanently lit.
• Remove the heating module from the holder and put it back; the right and le
LEDs must be lit.
If the thermostat is no longer paired with the heating module, contact Customer
Service.
1
2
3
ERROR CODES
19.5
1
Problem with pairing
2
Communication problem
3
Disconnection
STARTING UP
Welcome Heating
command
Stop
command
Room
temperature
Setpoint
temperature Heating o Heating in
progress
LED display
Heat indicator
Activation zone
Arrows
OPERATION BUTTONS
19.5
You can activate the product
by tapping the activation area
The setpoint temperature
can be set using the
arrows
DURING INSTALLATION
Updating, please be patient. Pairing with the module Restart
THERMOSTAT

8 9
19.5
RECOMMENDATIONS
FOR INSTALLATION
INSTALLATION
Make sure that the thermostat is installed in a living area.
Where do you install the COMAP Smart Home thermostat?
• In an occupied room, usually in the living room
• Do not install against an outside wall or in draughty spaces
• Between 1.2 and 1.5 m from the ground
• Keep away from doors, wall cupboards or other objects that may interfere with the
presence detection sensor.
• Place the thermostat in a place where it cannot be exposed to direct sunlight.
• If you have pets, place the thermostat away from furniture they can sit on so that they
are not detected by the presence detection sensor.
Recommended locations
Connect the gateway to the modem using the two cables supplied.
Note: If the modem does not have a
USB port, you can connect the gateway
to the mains using a 5V DC USB charger
/ minimum 200mA (not supplied).
Connect the gateway
Both LEDs on the gateway should light up:
• The power light on the le indicates that the gateway
is being powered
• The communication light on the right indicates that there
is a good internet connection.
1

10 11
19.5
Remove the battery protection tab
on the thermostat
A symbol indicating that the product
is starting up correctly will then
appear on the thermostat display.
2
GAS, OIL, WOOD, HEAT PUMP, ELECTRIC (ON/OFF CONTACT)
Replacing a wired thermostat........................................................................ 12
Replacing a wireless thermostat or 1st installation................................... 16
ELECTRICAL VERSION (CONTROL WIRE) ............................................................ 19
The following steps depend on the heating system:
Switch o the general power supply to the housing in order to avoid any risk of electrocution.
Switch off the power
3

12 13
Heating module Thermostat
Water radiator Phase (L)
Neutral (N)
Water radiator
Water radiator
Boiler
(or stove or
heat pump)
19.5
19.5
LS
TA
LR
N
Gateway
30 m
max.
GAS, OIL, WOOD, HEAT PUMP,
ELECTRIC (ON/OFF CONTACT)
INSTALLATION WITH ON/OFF CONTACT
Replacing a wired thermostat with 2-3 wires or first installation
Input 220V
Wires usually blue
(N) and brown (L/P)
Example: Connection block of the heating module
Room thermostat
Wires usually red
or yellow
Note: Some thermostats are connected to
an input other than the one listed above
(eBus or EMS, for example). In this case, identify
the thermostat input TA, LS-LR or RT24.
To install it, open the protective cover of your water heater (using the manual if
necessary). Find the terminal block of the room thermostat.
Connect terminals L (phase) and N (neutral) of the heating module to terminals L
and N of the boiler or the terminal box. This will supply power to the heating module.
Check the stripping distances of the cables and wires.
Connect the terminals of the on/o
contact to the input for the on/o
contact of the boiler (TA or LS-LR).
1Connect the module to the heating system

14 15
Heating module Thermostat
Gateway
Electric radiator
Electric radiator
Electric radiator
Electric panel
19.5
19.5
Phase (L)
Neutral (N)
Control wire (P)
30 m
max.
Note: The current circuit of the potential-free contact
must be adjusted to the capacity of the radiators being
controlled. The required current for the control circuit
must be less than 3A.
Attach the heating module holder
2
INSTALLATION OF THE CONTROL WIRE
Installation on electric heating with centralised control wires
- Single zone -
ELECTRIC VERSION

16 17
Gateway
Heating module
Heating module
Heating module
Thermostat
Electric radiator
Electric radiator
Electric radiator
Electric panel
*Protection depending on your installation
19.5
19.5
19.5
19.5
Phase (L)
Neutral (N)
Control wire (P)
30 m
max.
Installation on electric heating with multiple control
wires - Single zone or multi-zone -
Note for multi-zones: You can create up to 10 zones, with one or more radiators in each zone.
To configure your zones, go to "My Account" > "Configure Multi-Zones" once the installation is complete.
1 2
Open the module by
unclipping the back.
Open the heating module.
Then thread the wires through the hole in the
holder. Check the stripping distances of the cables
and wires.
Open the protective cover.

18 19
B. Place the heating module(s) on their
holder.
The on/o light of the heating module(s) must
be on and the communication symbol must be
flashing, indicating that a request for connection
to the thermostat is ongoing.
FP
19.5
3 4
Attach the heating module
holder
Connect the wires
Attach with the dowels and screws.
Connect the three wires as shown. In
general, the phase wire (L) is brown, the
neutral wire (N) is blue and the control
wire (FP) is black.
The cross-sectional area of the cables
used for the power supply (L, N) and
the control wire must be adapted to
the protection installed upstream.
Next steps p. 23
Repeat the installation of
the heating module for each
radiator. Screw the lid back on.
INSTALLATION
A. Switch the power on again
CONTINUATION OF THE STEPS (same for all installations)

20 21
19.5
19.5
prog
C. Control wire: Put your radiators
in"programming" mode
C. On/Off contact: Check whether
the heating part is activated
D. Move the thermostat closer to the heating
module
If you move closer to the heating module,
the thermostat will detect it.
Press the centre to activate the thermostat.
The screen lights up. The pairing symbol
appears in the thermostat display, which will
automatically pair with the heating module.
E. Activate the COMAP CSH thermostat
If necessary, you can perform a heating test by
increasing the temperature using the arrow to the
right: a flame will appear on the thermostat display
and the sensor will turn red, indicating a heating
command.
The heating light in the centre of the heating module
must then light up.
Aerwards, do not forget to lower the temperature
by pressing the le arrow on the thermostat.
If you have more than one heating module, repeat steps D. and E. for each module.

22 23
F. Attach the thermostat
1Remove the thermostat holder
by unclipping it.
2Fix the holder to the wall using screws
and dowels. Recommended location
p. 22
3Place the thermostat on the holder
by clicking it into place.
CONGRATULATIONS,
YOUR INSTALLATION IS COMPLETE.

24 25
Certificates and general terms and conditions
COMAP declares that the device is in compliance with the essential requirements and other
relevant provisions of the R&TTE directive 1999/5/EC.
Wireless features
Connection of the gateway to the modem via USB 5V DC 200mA power supply and RJ45
Ethernet port.
Long-range wireless connection between the COMAP CSH thermostat, the heating module
and the gateway.
Thermostat sensors and measurements
High-precision temperature sensor
Measuring range: 0°C to 50°C
Sensitivity: +/- 0.05°C
Temperature (set point): 7°C to 25°C
Increase: 0.5°C
Presence sensor with wide field
Humidity sensor
Heating module
Operating temperature: 0 to 55°C.
Power supply 230V~, 50Hz.
Power consumption: 200mA
The cross-section of the cables to be connected must be between 0.75 mm² and 2.5 mm².
Version with control wire: The heating module must be protected by a circuit breaker
of max. 2 A.
Version with on/o contact: The heating module must be protected by a circuit breaker
with an output of max. 2 A.
Contamination level: 2
Nominal pulse voltage: 2500V
Automatic action: type 1
Maximum current of the dry contact: 3A
Required material
Modem with one RJ45 port and one free USB port. Without a USB port, a USB charger
is required (not included).
SPECIFICATIONS
Dimensions
Thermostat: 110x110x25mm
Heating module: 110x110x25mm
Gateway: 82x82x23mm
Design
Design: 5.5 Design Studio
LED display
Touch interface
Heat indicator
2-year guarantee
Warnings
The thermostat, heating module and gateway are intended for indoor use only.
The heating module and the gateway must be installed in accordance with the applicable standards.
Use 3 LR3 - AAA batteries to power the thermostat. Do not use rechargeable batteries.
Keep children away from batteries. If swallowed, seek medical advice immediately.
Do not attempt to repair this device yourself, an aer-sales service is available.
Any changes or modifications not expressly approved in these instructions will invalidate any guarantee claims.
Heating module: Insulation class II
Gateway: Insulation class III
Copyright COMAP © 2022 all rights reserved.
Reproduction and distribution prohibited without the permission of COMAP.

FAQ: http://support.comapsmarthome.com
Email: contact@comapsmarthome.com
Please do not hesitate to contact us, our sta will be happy to help you:
Table of contents
Popular Thermostat manuals by other brands

Aube Technologies
Aube Technologies TH147 specification

Uponor
Uponor Ecoflex Supra Standard ETN4 Installation and operation manual

Warmup
Warmup OTN-1991-WA instructions

Hagen
Hagen EXO TERRA PT2463 operating instructions

Flomasta
Flomasta 4718G Guide

emmeti
emmeti CHRONOTHERMOSTAT User manual installer/operator system