Testing Airflow
When the damper is powered, the damper goes to a fully open
position and displays a green LED.
Step 2. Apply Power
Limited 5-Year Warranty
The 5-year warranty is limited to the repair or replacement of
defective product due to parts failure or defective workmanship. 26072 Merit Circle #110 / Laguna Hills, CA 92653
949-916-0945 Fax 949-458-8502 www.eControlsUSA.com
eControls
Damper Position
Open
Closed
Partially Closed
Damper LEDs and Position
LED
Green
Red
Green and Red
LED Blink.
0%
Between
100% and 0%
100%
Airflow Setting
Remove the battery
cover on the back of
the remote control.
Install two AAA
batteries.
Step 3. Install Batteries
+
+
The remote will immediately
power up and default to
Zone 1, Address 1 and
100% Airflow.
ZONE
AIRFLOW
%
The WRCD Remote and the Damper default to Zone 01 and
Address 01. At the thermostat, activate a heating or cooling call.
The remote control should display 100%. Measure or feel the
airflow going to the space as a reference.
Press the Down key on the remote control to set the airflow to
0%. The damper should go to the closed position and display a
red LED. You should measure or feel very little airflow to the
space.
Press the Up key to set the airflow to 50%. The damper should
go to a partially closed position and display a green and red
blinking LED. You should measure or feel some airflow to the
space but not as much as at 100%.
Press the Up key to set the airflow to 100%. The damper should
completely open and display a green LED.
Changing the Actuator Zone Number
The dampers are factory set for Zone 1 and Address 1 and only
need to be changed when the remote control is controlling
airflow to multiple zones or spaces or another WRCD installation
is within 100 feet.
24VAC
24VAC
Press and hold the push button switch. The
green LED blinks once, pauses then blinks
twice, pauses then blinks three times, etc.
up to eight times. Release the switch after
the number of blinks corresponding to the
Zone number to be set. The Zone number
can be reset at anytime.
Push Button Switch
Changing the Actuator Address Number
The dampers are factory set for Address 1 and only need to be
changed when the remote control is controlling airflow to
multiple zones or spaces or another WRCD installation is within
100 feet.
24VAC
24VAC
Turn power Off to the actuator. Press and
hold the push button switch while applying
24VAC power to the actuator. The red LED
blinks once, pauses then blinks twice,
pauses then blinks three times, etc. up to
eight times. Release the switch after the
number of blinks corresponding to the
Address number to be set. The Address
number can be reset at anytime.
Push Button Switch
Document Multiple Zone Locations
When a WRCD Remote Control is used to control airflow to
multiple zones or spaces, record the zone locations below. An
expanded form that includes Zones and Address numbers is
available online at eControlsUSA.com/resources.
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
If the space has a different Zone and/or Address number than
the default, make sure the WRCD Zone and Address number
matches the Zone and Address number set in the dampers for
the space. See the WRCD User Manual for instructions on
changing the Zone and/or Address number in the remote.
Repeat the steps above to test the airflow.