#20622_A
US customer support 1-888-622-2377 | www.commandaccess.com | CA customer support 1-855-823-3002
6
Step 1 - Select your preferred torque mode (ships in standard torque). Press the
device push pad to the desired setting. (We recommend to fully depress
and release 5%, giving the device room for changing door conditions.)
Step 2 - While depressing the push pad, apply power. (i.e. presenting the credential
to the reader).
Step 3 - Continue to keep the pad depressed, the device will beep 6 times. After the
beeps have stopped, release the pad and the adjustment is now complete.
If not to your liking repeat the 3 steps.
2 Beeps
3 Beeps
5 Beeps
6 Beeps
Beeps Explanation Solution
Over Voltage
Under Voltage
Retraction or dogging failure
PUSH TO SET
> 30V unit will shut down. Check voltage & adjust to 24 V.
< 20V unit will shut down. Check voltage & adjust to 24 V.
After 1st fail: 5 beeps then immediately attempts to retract again.
After 2nd fail: 5 beeps with pause in-between for 30 seconds then device
attempts to retract again.
After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract.
To Reset: Depress bar for 5 seconds at any time.
Device is recording it’s new position and power mode after the 6th beep.
Troubleshooting & Diagnostics
4 Beeps Failed Sensor Verify all 3 sensor wires are installed correctly. Replace sensor if problem
persists by contacting oce.
Make sure to set PTS before finishing installation
10 Slide on the Filler Plate and connect the motor to power. Test using the instructions below.
installation instructions
MM4S SWITCHES
2
STANDARD TORQUE
HIGH TORQUE
PTS PROGRAMMING OFF
PTS PROGRAMMING ON
1OFF
OFF
ON
ON