Installation Steps:
Refer to the following diagram when you install the fixture.
1. Directly fix to mounting surface
1.Use expansion bolts to secure the fixture on mounting surface.
2. Keep enough length wires to ensure adjusting angle unhindered.
Connect wires into wiring terminal; white wire to “Neutral” terminal, black wire to “Live” terminal,
green wire to “Ground” terminal; and fix them by screws.
2. Mounting with a knuckle
Secure service wire or conduit to the wiring compartment cover with 1/2” connector ( not
provided ). Connect white fixture wire to white supply wire, black fixture wire to black supply wire.
Service ground should be attached to green ground screw rovided. Ground must be properly
attached to avoid the risk of electrical shock. Use wire nuts, crimp-on lugs, or other approved
devices to connect all wires, make sure connections are secure and that no loose wire strands are
sticking out of connectors, Secure wiring compartment cover to fixture. With black and white
connections inside the wiring compartment. Use UL and CUL Listed flexible steel waterproof conduit
in trade sizes 1/2 and UL and CUL Listed Water-proof outlet box cove.
After installation, please
Check whether the lighting fixture is firmly fixed.
Check whether wires are connected correctly.
At last, turn on the power, and check if the lighting fixture works well. If not, please turn off the
power and contact with local dealer.