CommScope Ruckus ICX 7750 Manual

Part Number: 53-1003900-10
Publication Date: 30 September 2020
RUCKUS ICX 7750 Switch
Hardware Installation Guide
HARDWARE INSTALLATION GUIDE

Copyright, Trademark and Proprietary Rights Information
© 2020 CommScope, Inc. All rights reserved.
No part of this content may be reproduced in any form or by any means or used to make any derivative work (such as translation,
transformation, or adaptation) without written permission from CommScope, Inc. and/or its affiliates (“CommScope”). CommScope
reserves the right to revise or change this content from time to time without obligation on the part of CommScope to provide notification
of such revision or change.
Export Restrictions
These products and associated technical data (in print or electronic form) may be subject to export control laws of the United States of
America. It is your responsibility to determine the applicable regulations and to comply with them. The following notice is applicable for all
products or technology subject to export control:
These items are controlled by the U.S. Government and authorized for export only to the country of ultimate destination for use by the
ultimate consignee or end-user(s) herein identified. They may not be resold, transferred, or otherwise disposed of, to any other country or
to any person other than the authorized ultimate consignee or end-user(s), either in their original form or after being incorporated into
other items, without first obtaining approval from the U.S. government or as otherwise authorized by U.S. law and regulations.
Disclaimer
THIS CONTENT AND ASSOCIATED PRODUCTS OR SERVICES (“MATERIALS”), ARE PROVIDED “AS IS” AND WITHOUT
WARRANTIES OF ANY KIND, WHETHER EXPRESS OR IMPLIED. TO THE FULLEST EXTENT PERMISSIBLE PURSUANT TO
APPLICABLE LAW, COMMSCOPE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO,
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT,
FREEDOM FROM COMPUTER VIRUS, AND WARRANTIES ARISING FROM COURSE OF DEALING OR COURSE OF
PERFORMANCE. CommScope does not represent or warrant that the functions described or contained in the Materials will be
uninterrupted or error-free, that defects will be corrected, or are free of viruses or other harmful components. CommScope does not make
any warranties or representations regarding the use of the Materials in terms of their completeness, correctness, accuracy, adequacy,
usefulness, timeliness, reliability or otherwise. As a condition of your use of the Materials, you warrant to CommScope that you will not
make use thereof for any purpose that is unlawful or prohibited by their associated terms of use.
Limitation of Liability
IN NO EVENT SHALL COMMSCOPE, COMMSCOPE AFFILIATES, OR THEIR OFFICERS, DIRECTORS, EMPLOYEES, AGENTS,
SUPPLIERS, LICENSORS AND THIRD PARTY PARTNERS, BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, PUNITIVE,
INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES, OR ANY DAMAGES WHATSOEVER, EVEN IF COMMSCOPE HAS
BEEN PREVIOUSLY ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, WHETHER IN AN ACTION UNDER CONTRACT,
TORT, OR ANY OTHER THEORY ARISING FROM YOUR ACCESS TO, OR USE OF, THE MATERIALS. Because some jurisdictions
do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of liability for consequential or incidental
damages, some of the above limitations may not apply to you.
Trademarks
ARRIS, the ARRIS logo, CommScope, Ruckus, Ruckus Wireless, Ruckus Networks, Ruckus logo, the Big Dog design, BeamFlex,
ChannelFly, EdgeIron, FastIron, HyperEdge, ICX, IronPoint, OPENG, SmartCell, Unleashed, Xclaim, and ZoneFlex are trademarks of
CommScope, Inc. and/or its affiliates. Wi-Fi Alliance, Wi-Fi, the Wi-Fi logo, Wi-Fi Certified, the Wi-Fi CERTIFIED logo, Wi-Fi Protected
Access, the Wi-Fi Protected Setup logo, Wi-Fi Protected Setup, Wi-Fi Multimedia and WPA2 and WMM are trademarks or registered
trademarks of Wi-Fi Alliance. All other trademarks are the property of their respective owners.

Ruckus ICX 7750 Switch Hardware Installation Guide 1
Part Number: 53-1003900-10
Contents
Preface
Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Notes, cautions, and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Command syntax conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Document feedback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ruckus product documentation resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Online training resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Contacting Ruckus Customer Services and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
What support do I need? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Open a case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Self-service resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
About this Document
What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Ruckus ICX 7750 Overview
Ruckus ICX 7750 features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ruckus ICX 7750 orderable models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ruckus ICX 7750 customizable models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Views of the Ruckus ICX 7750 switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Ruckus ICX 7750 slot and Ethernet port numbering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Supported expansion module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Supported transceivers and cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
High-power 40 GbE optic support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Breakout cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
QSFP+ to SFP+ adapter support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
10G-SFPP-TX-A transceiver support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installing the Ruckus ICX 7750
Shipping carton contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installation and safety considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Electrical considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Environmental considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Location considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Rack considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Recommendations for cable management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Installation tasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Installation precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
General precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Lifting precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Power precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
DC-DC power source cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Installing the device in a rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Two-post rack mount installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

2Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
Installing the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks (XBR-R000295) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Installation requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Time and items required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Flush-front mounting the device in the rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Flush-rear (recessed) mounting the device in the rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Grounding the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Powering on the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Power supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Installing and replacing a power supply unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Installing an AC power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Installing a DC power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Attaching a PC or terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Connecting to the management port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Installing an SFP+ or a QSFP+ transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Connecting network devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Connecting a network device to a copper port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Connecting a network device to a fiber port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Connecting breakout cables to 40 GbE ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Stacking Ruckus ICX 7750 switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Stacking ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Stacking configuration requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Stacking cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Extended distance stacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Stack size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Stacking topologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Ruckus ICX 7750 Operation
LED activity interpretation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Ruckus ICX 7750 front-panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Ruckus ICX 7750 rear-panel LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
LED patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Diagnostic tests and monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Monitoring power and cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Managing the Ruckus ICX 7750
Hardware maintenance schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Replacing a copper or fiber-optic module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Removing a copper or fiber-optic module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Cabling a fiber-optic module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Cleaning the fiber-optic connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
FRU removal and replacement procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Replacing a power supply unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Determining the need to replace a power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Time and items required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Replacing a power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Ruckus ICX 7750 Switch Hardware Installation Guide 3
Part Number: 53-1003900-10
Replacing fan trays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Determining the need to replace a fan tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Time and items required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Installing or replacing the fan tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Replacing an expansion module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Time and items required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Installing or replacing an expansion module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Ruckus LRM Adaptor Module
LRM adaptor module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
LRM module part numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
LRM adaptor module specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
ICX platform support for the LRM module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Unpacking the LRM module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Ruckus ICX 7750 Specifications
System specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Weight and physical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Power supply specifications (per PSU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Power consumption (typical configuration) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Power consumption (maximum configuration) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Power consumption (modules) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Data port specifications (Ethernet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Serial port specifications (pinout mini-USB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Serial port specifications (pinout RJ-45) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Serial port specifications (protocol) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Memory specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Regulatory compliance (EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Regulatory compliance (safety) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Regulatory compliance (environmental). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Ruckus ICX 7750 Regulatory Statements
USA (FCC CFR 47 Part 15 Warning) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Industry Canada statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Europe and Australia (CISPR 22 Class A Warning) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Germany (Noise Warning) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Japan (VCCI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Korea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
China . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
BSMI statement (Taiwan). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Ruckus ICX 7750 Cautions and Danger Notices
Cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Danger notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

4Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10

Ruckus ICX 7750 Switch Hardware Installation Guide 5
Part Number: 53-1003900-10
Preface
•Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
•Document feedback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
•Ruckus product documentation resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
•Online training resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
•Contacting Ruckus Customer Services and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Document conventions
The following tables list the text and notice conventions that are used throughout this guide.
Notes, cautions, and warnings
Notes, cautions, and warning statements may be used in this document. They are listed in the order of increasing severity of potential
hazards.
NOTE
A Note provides a tip, guidance, or advice, emphasizes important information, or provides a reference to related information.
Command syntax conventions
Bold and italic text identify command syntax components. Delimiters and operators define groupings of parameters and their logical
relationships.
TABLE 1 Text conventions
Convention Description Example
monospace Identifies command syntax examples. device(config)# interface ethernet 1/1/6
bold User interface (UI) components such
as screen or page names, keyboard
keys, software buttons, and field
names
On the Start menu, click All Programs.
italics Publication titles Refer to the Ruckus Small Cell Release Notes for more information
CAUTION
A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware,
firmware, software, or data.
DANGER
A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you.
Safety labels are also attached directly to products to warn of these conditions or situations.

6Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
Preface
Document feedback
Document feedback
Ruckus is interested in improving its documentation and welcomes your comments and suggestions.
When contacting us, please include the following information:
•Document title and release number
•Document part number (on the cover page)
•Page number (if appropriate)
•For example:
-Ruckus Small Cell Alarms Guide SC Release 1.3
-Part number: 800-71306-001
-Page 88
Ruckus product documentation resources
Visit the Ruckus website to locate related documentation for your product and additional Ruckus resources.
Release Notes and other user documentation are available at https://support.ruckuswireless.com/documents. You can locate
documentation by product or perform a text search. Access to Release Notes requires an active support contract and Ruckus Support
Portal user account. Other technical documentation content is available without logging into the Ruckus Support Portal.
White papers, data sheets, and other product documentation are available at https://www.ruckuswireless.com.
Convention Description
Boldface text Identifies command names, keywords, and command options.
Italics text Identifies a variable.
value In Fibre Channel products, a fixed value provided as input to a command option is printed in plain text,
for example, --show WWN.
[ ] Syntax components displayed within square brackets are optional.
Default responses to system prompts are enclosed in square brackets.
{ x| y| z} A choice of required parameters is enclosed in curly brackets separated by vertical bars. You must select
one of the options.
In Fibre Channel products, square brackets may be used instead for this purpose.
x| yA vertical bar separates mutually exclusive elements.
< > Nonprinting characters, for example, passwords, are enclosed in angle brackets.
... Repeat the previous element, for example, member[member...].
\ Indicates a “soft” line break in command examples. If a backslash separates two lines of a command
input, enter the entire command at the prompt without the backslash.

Ruckus ICX 7750 Switch Hardware Installation Guide 7
Part Number: 53-1003900-10
Preface
Online training resources
Online training resources
To access a variety of online Ruckus training modules, including free introductory courses to wireless networking essentials, site surveys,
and Ruckus products, visit the Ruckus Training Portal at https://training.ruckuswireless.com.
Contacting Ruckus Customer Services and Support
The Customer Services and Support (CSS) organization is available to provide assistance to customers with active warranties on their
Ruckus Networks products, and customers and partners with active support contracts.
For product support information and details on contacting the Support Team, go directly to the Support Portal using https://
support.ruckuswireless.com, or go to https://www.ruckuswireless.com and select Support.
What support do I need?
Technical issues are usually described in terms of priority (or severity). To determine if you need to call and open a case or access the
self-service resources use the following criteria:
•Priority 1 (P1)—Critical. Network or service is down and business is impacted. No known workaround. Go to the Open a Case
section.
•Priority 2 (P2)—High. Network or service is impacted, but not down. Business impact may be high. Workaround may be
available. Go to the Open a Case section.
•Priority 3 (P3)—Medium. Network or service is moderately impacted, but most business remains functional. Go to the
Self-Service Resources section.
•Priority 4 (P4)—Low. Request for information, product documentation, or product enhancements. Go to the Self-Service
Resources section.
Open a case
When your entire network is down (P1), or severely impacted (P2), call the appropriate telephone number listed below to get help:
•Continental United States: 1-855-782-5871
•Canada: 1-855-782-5871
•Europe, Middle East, Africa, and Asia Pacific, toll-free numbers are available at https://support.ruckuswireless.com/contact-us
and Live Chat is also available.
Self-service resources
The Support Portal at https://support.ruckuswireless.com/contact-us offers a number of tools to help you to research and resolve
problems with your Ruckus products, including:
•Technical Documentation—https://support.ruckuswireless.com/documents
•Community Forums—https://forums.ruckuswireless.com/ruckuswireless/categories
•Knowledge Base Articles—https://support.ruckuswireless.com/answers
•Software Downloads and Release Notes—https://support.ruckuswireless.com/software
•Security Bulletins—https://support.ruckuswireless.com/security

8Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
Preface
Contacting Ruckus Customer Services and Support
Using these resources will help you to resolve some issues, and will provide TAC with additional data from your troubleshooting analysis
if you still require assistance through a support case or RMA. If you still require help, open and manage your case at https://
support.ruckuswireless.com/case_management

Ruckus ICX 7750 Switch Hardware Installation Guide 9
Part Number: 53-1003900-10
About this Document
•What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
What’s new in this document
The following table includes descriptions of new information added to this edition.
TABLE 2 Summary of enhancements added to this edition
Feature Description Described in
10G-SFPP-TX transceiver support Added guidelines for using the 10G-SFPP-TX
transceiver
“10G-SFPP-TX-A transceiver support”
Power and cooling Added information on fan speeds and temperature
thresholds
“Monitoring power and cooling”

10 Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
About this Document
What’s new in this document

Ruckus ICX 7750 Switch Hardware Installation Guide 11
Part Number: 53-1003900-10
Ruckus ICX 7750 Overview
•Ruckus ICX 7750 features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
•Views of the Ruckus ICX 7750 switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
•Ruckus ICX 7750 slot and Ethernet port numbering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
•Supported expansion module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
•Supported transceivers and cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Ruckus ICX 7750 features
The Ruckus ICX 7750 is a high-density aggregation switch that offers both 1/10 and 10/40 Gigabit Ethernet (GbE) line rates, low
latency cut-through switching, and up to 2.56 Tbps throughput for campus LAN and classic Ethernet data center environments.
The Ruckus ICX 7750 switch features:
•Comprehensive support for a range of 1 GbE, 10 GbE, and 40 GbE optics (refer to the Ruckus Optics Family Data Sheet).
•Dual redundant, hot-swappable 504 W AC or DC power supplies available with intake or exhaust airflow.
•Optional 6-port 10/40 GbE QSFP+ expansion/stacking module.
•Four hot-swappable fan units available with intake or exhaust airflow.
•One Gigabit Ethernet port (RJ-45) and one serial management port (mini-USB) to configure and manage the switch through the
CLI.
•One USB port for the transfer of software and configuration files from an external disk drive.
Ruckus ICX 7750 orderable models
The Ruckus ICX 7750 consists of three orderable models, as shown in Table 3.
Ruckus ICX 7750 customizable models
The Ruckus ICX 7750 base systems do not ship with power supplies or fans. Fans and power supplies are ordered separately to allow for
building the system that meets your network needs. Table 4 lists the available power supplies, fans, and the expansion module.
TABLE 3 Ruckus ICX 7750 orderable switch models
Model Description
ICX 7750-26Q Ruckus ICX 7750 with 26 10/40 GbE QSFP+ ports. No power supplies, fan units, or expansion module (must be
ordered separately). Advanced software. No optics.
ICX 7750-48F Ruckus ICX 7750 with 48 1/10 GbE SFP+ ports and six 10/40 GbE QSFP+ ports. No power supplies, fan units,
or expansion module (must be ordered separately). Advanced software. No optics.
ICX 7750-48C Ruckus ICX 7750 with 48 1/10 GbE RJ-45 ports and six 10/40 GbE QSFP+ ports. No power supplies, fan
units, or expansion module (must be ordered separately). Advanced software. No optics.

12 Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
Ruckus ICX 7750 Overview
Views of the Ruckus ICX 7750 switch
Views of the Ruckus ICX 7750 switch
Figure 1 shows the front view of the Ruckus ICX 7750-26Q switch.
FIGURE 1 Front view of the Ruckus ICX 7750-26Q
Figure 2 shows the front view of the Ruckus ICX 7750-48F switch.
TABLE 4 SKUs for creating custom Ruckus ICX 7750 switch models
SKUs Description
RPS9+E 504 W AC power supply; power-supply-side exhaust (port-side intake) airflow.
RPS9+I 504 W AC power supply; power-supply-side intake (port-side exhaust) airflow.
RPS9DC+E 504 W DC power supply; power-supply-side exhaust (port-side intake) airflow.
RPS9DC+I 504 W DC power supply; power-supply-side intake (port-side exhaust) airflow.
ICX 7750-FAN-E Ruckus ICX 7750 kit of four fans, exhaust airflow.
ICX 7750-FAN-I Ruckus ICX 7750 kit of four fans, intake airflow.
ICX 7750-6Q Ruckus ICX 7750 6-port QSFP+ expansion/stacking module.
1 QSFP+ ports XL1/1 - XL1/20 and XL2/1 -
XL2/6
4 Console port
2SystemLEDs 5Resetbutton
3 Stack unit ID display 6 QSFP+ port LEDs

Ruckus ICX 7750 Switch Hardware Installation Guide 13
Part Number: 53-1003900-10
Ruckus ICX 7750 Overview
Views of the Ruckus ICX 7750 switch
FIGURE 2 Front view of the Ruckus ICX 7750-48F
Figure 3 shows the front view of the Ruckus ICX 7750-48C switch.
FIGURE 3 Front view of the Ruckus ICX 7750-48C
Figure 4 shows the rear view of the Ruckus ICX 7750 switch.
1 SFP+ ports 1/1 - 1/48 5 Console port
2 QSFP+ ports XL2/1 - XL2/6 6 Reset button
3SystemLEDs 7SFP+portLEDs
4 Stack unit ID display 8 QSFP+ port LEDs
1 10GBase-T RJ-45 ports 1/1 - 1/48 5 Console port
2 QSFP+ ports XL2/1 - XL2/6 6 Reset button
3 System LEDs 7 10GBase-T port LEDs
4 Stack unit ID display 8 QSFP+ port LEDs

14 Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
Ruckus ICX 7750 Overview
Ruckus ICX 7750 slot and Ethernet port numbering
FIGURE 4 Rear view of the Ruckus ICX 7750
Ruckus ICX 7750 slot and Ethernet port numbering
Many CLI commands require users to enter port numbers as part of the command syntax, and many show command outputs display
port numbers. The port numbers are entered and displayed in stack-unit/slot number/port number format.
The Ruckus ICX 7750 contains the following slots and Ethernet ports:
•Slot 1 and Slot 2 are located on the front of the Ruckus ICX 7750-26Q device. Slot 1 contains 10/40 GbE QSFP+ ports
XL1/1 through XL1/20; odd port numbers on the top row with port XL1/1 on the left and port XL1/20 on the right. Slot 2
contains 10/40 GbE QSFP+ ports XL2/1 through XL2/6; ports XL2/1, XL2/3, and XL2/5 are on the top row (left to right), and
ports XL2/2, XL2/4, and XL2/6 are on the bottom row (left to right).
FIGURE 5 Ruckus ICX 7750-26Q slot numbering
1 Power supply unit 2 9 Fan tray 3
2 Fan tray LED 10 UP and DN port LEDs
3 Management port 11 Control path UP and DN ports (currently not used)
4 USB port 12 QSFP+ module LEDs
5 6-port 10/40 GbE QSFP+ expansion module 13 Expansion module power LED
6 Power supply unit 1 14 Fan tray 2
7 Power supply unit 2 LED 15 Fan tray 1
8 Fan tray 4
1Slot1 2Slot2

Ruckus ICX 7750 Switch Hardware Installation Guide 15
Part Number: 53-1003900-10
Ruckus ICX 7750 Overview
Supported expansion module
•Slot 1 and Slot 2 are located on the front of the Ruckus ICX 7750-48F device. Slot 1 contains 1/10 GbE SFP+ ports 1/1
through 1/48, with odd port numbers on the top row and port 1/1 on the left. Slot 2 contains 10/40 GbE QSFP+ ports XL2/1,
XL2/3, and XL2/5 on the top row (left to right), and ports XL2/2, XL2/4, and XL2/6 on the bottom row (left to right).
FIGURE 6 Ruckus ICX 7750-48F slot numbering
•Slot 1 and Slot 2 are located on the front of the Ruckus ICX 7750-48C device. Slot 1 contains 1/10 GbE RJ-45 ports 1/1
through 1/48, with odd port numbers on the top row and port 1/1 on the left. Slot 2 contains 10/40 GbE QSFP+ ports XL2/1,
XL2/3, and XL2/5 on the top row (left to right), and ports XL2/2, XL2/4, and XL2/6 on the bottom row (left to right).
FIGURE 7 Ruckus ICX 7750-48C slot numbering
•Slot 3 is located on the rear of the Ruckus ICX 7750 switches and contains ports XL3/1, XL3/3, and XL3/5 on the top row (left
to right) and ports XL3/2, XL3/4, and XL3/6 on the bottom row (left to right). These ports are 10/40 GbE QSFP+ ports.
FIGURE 8 Ruckus ICX 7750 rear slot numbering
Supported expansion module
A 6-port 10/40 GbE QSFP+ expansion/stacking module can be purchased and installed in the rear of the Ruckus ICX 7750. The
module supports a range of 10 GbE and 40 GbE optics (refer to the Ruckus Optics Family Data Sheet).
Instructions for installing or replacing an expansion/stacking module are described in “Replacing an expansion module” on page 66.
1Slot1 2Slot2
1Slot1 2Slot2
1Slot3

16 Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
Ruckus ICX 7750 Overview
Supported transceivers and cables
FIGURE 9 10/40 GbE QSFP+ expansion module
Supported transceivers and cables
For a list of supported transceivers and cables, refer to the Ruckus Optics Family Data Sheet.
High-power 40 GbE optic support
Certain 40 GbE transceivers require higher power to operate. Cooling and power considerations limit the use of these optics in the Ruckus
ICX 7750 switch. These optics include the 40GBASE-LR4, 40GBASE-LM4, 40GBASE-SR-BIDI, and 40GBASE-ER4 transceivers.
Table 5 indicates the port range limitations for these optics based on airflow direction and switch model.
The Ruckus ICX 7750 also supports 40GBASE-SR-BD bi-directional (BiDi) QSFP+ transceivers with duplex LC optics. The 40 GbE
BiDi optics support two 20 GbE channels over duplex fiber cable, with the transmit and receive of each channel operating at two
wavelengths on a single fiber.
1 Assembly screws 3 Expansion module power LED
2 Release lever latch 4 QSFP+ slot LEDs
TABLE 5 Ruckus ICX 7750 high-power 40GbE optics support
Model Airflow Front panel ports Optional 40 GbE module ports
ICX 7750-26Q Exhaust 1/1/1 through 1/1/20
1/2/1 through 1/2/6
1/3/5 and 1/3/6
Inlet 1/2/5 and 1/2/6 1/3/5 and 1/3/6
ICX 7750-48F Exhaust 1/2/1 and 1/2/6 1/3/5 and 1/3/6
Inlet 1/2/5 and 1/2/6 1/3/5 and 1/3/6
ICX 7750-48C Exhaust 1/2/1 and 1/2/6 1/3/5 and 1/3/6
Inlet 1/2/5 and 1/2/6 1/3/5 and 1/3/6

Ruckus ICX 7750 Switch Hardware Installation Guide 17
Part Number: 53-1003900-10
Ruckus ICX 7750 Overview
Supported transceivers and cables
The 40 GbE BiDi transceivers enable 40 GbE links to be supported on installed 10 GbE duplex fiber infrastructure. This optic has the
same port limitations as the LR4 optic.
Breakout cables
The Ruckus ICX 7750 can support the following breakout cables on certain 40 GbE ports:
•QSFP+ to 4 SFP+ (4x10 GbE) direct-attach copper breakout cables, lengths of 1, 3, and 5 m
•4x10 GbE QSFP+ SR4 compatible with 10GBase-SR SFP+ using 1, 2, 3, 5, 7, 10, 15, and 100 m lengths of fiber cable
FIGURE 10 QSFP+ to 4 SFP+ (4x10 GbE) breakout cable
The Ruckus ICX 7750 ports available for breakout are shown for each model in Table 6.
QSFP+ to SFP+ adapter support
The Ruckus ICX 7750 supports a third-party QSFP+ to SFP+ adapter for cost-effective connections between 40 GbE QSFP+ ports and
10 GbE hardware using standard SFP+ optical cabling rather than breakout cables.
An SFP+ transceiver (SR, LR, or USR) inserted in the QSFP+ to SFP+ adapter behaves as if it is connected to the first of the 4 breakout
ports on the 40 GbE QSFP+ interface with no other ports available in the breakout. The 4x10 GbE breakout mode must be configured on
the QSFP+ interface.
10G-SFPP-TX-A transceiver support
The 10G-SFPP-TX-A transceiver consumes significantly more power than typical 10G transceivers. This section provides guidelines for
deploying the 10G-SFPP-TX-A transceiver within the power capabilities of the supported ICX 7750-48F switch.
If the guidelines in this section are not followed, there is a risk of system instability and/or reboot.
Follow the guidelines provided in Table 7 to avoid a power violation.
For each 10G-SFPP-TX-A installed, another SFP+ slot MUST be left empty.
TABLE 6 Ruckus ICX 7750 40 GbE breakout ports
Model Front panel Slot 1 ports Front panel Slot 2 ports Rear module Slot 3 ports
ICX 7750-26Q 1/1/5 through 1/1/16 1/2/1 through 1/2/6 1/3/1 through 1/3/6
ICX 7750-48F N/A 1/2/1 through 1/2/6 1/3/1 through 1/3/6
ICX 7750-48C N/A 1/2/1 through 1/2/6 1/3/1 through 1/3/6

18 Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
Ruckus ICX 7750 Overview
Supported transceivers and cables
For example: If you are using four 10G-SFPP-TX-A, you must leave four SFP+ ports empty.
TABLE 7 Ruckus ICX 7750 10G-SFPP-TX-A transceiver support
Model 10G-SFPP-TX-A installed
location
For each 10G-SFPP-TX-A inserted, this
many SFP+ ports must remain unused.
ICX 7750-48F Port Group #1
1/1/1 to 1/1/32
1
Port Group ~2
1/1/33 to 1/1/48
1
Table of contents