manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Compaq
  6. •
  7. DC Drive
  8. •
  9. Compaq ULTRA2/ULTRA3 User manual

Compaq ULTRA2/ULTRA3 User manual

HOT-PLUGGABLE
WIDE ULTRA2/ULTRA3
HARD DRIVE
Availability of Japanese Documentation
To view or download Japanese versions of Compaq SCSI hard drive
documentation, go to the following Compaq website:
http://www.compaq.co.jp/products/manual3.html
To order a hard copy of the Compaq SCSI hard drive documentation in Japanese,
please contact the COMPAQ Japan Customer Call Center and provide them with
an HDD kit number and a serial number.
Compaq Japan Customer Call Center: 0120-101589
This is a tollfree call number. The center is available Monday through Friday
9:00 – 12:00/13:00 – 17:00 (Except during national holidays).
For the latest information and instructions on Compaq Hard Drives, such as
Hard Drive Compatibility tables, Important cards, and updated installation
instructions, refer to the Technical Information area at the following
Compaq website:
http://www.compaq.com/products/storageworks/hdd/appinfo.html
Additional Information
© 2000 Compaq Computer Corporation.
All rights reserved. Printed in the U.S.A.
Compaq, ProLiant, and ProSignia,
registered United States Patent and Trademark Office.
Sixth Edition (June 2000) Part Number 386195-006
386195- 006
Important Guidelines for Replacing Hot-Pluggable
Hard Drives
Follow these guidelines when replacing drives configured for fault tolerance on
a Compaq Smart or Smart2-Array Controller:
n
Never remove more than one drive at a time.
When a drive is replaced, the controller uses data from the other drives in the
array to reconstruct data on the replacement drive. If more than one drive is
removed, a complete data set is not available to reconstruct data on the
replacement drives and permanent data loss can occur.
n
Never remove a drive while another drive is being rebuilt.
A drive’s Online LED Indicators will be flashing green while it is being
rebuilt. A replaced drive is rebuilt from data stored on the other drives. See
Figure 1.
n
Never turn a disk enclosure off while the initiator or controller is
powered on or active.
Doing so can cause the initiator or controller to mark the drives as “failed.”
This can result in permanent data loss.
n
If a drive is replaced while the system is Off, it may be necessary to
rebuild the replaced drive.
Follow the instructions on the screen or the instructions outlined in the
system's reference guide.
OnlineOFF Drive Access Drive Failure
Drive
Indicators
Do not remove the drive. Removing the drive during this
process will cause data loss.
The drive is being accessed and is not configured as part of
an array.
Do not remove the drive. Removing the drive during this
process will cause data loss.
The drive is rebuilding or undergoing capacity expansion.
Do not remove the drive. Removing the drive during this
process will cause data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
The options ROMpaq is upgrading the drive.
- Or -
If this drive is part of an array, then a powered-on controller is
not accessing the drive.
- Or -
The drive is configured as an online spare.
- Or -
OK to replace the drive online if a predictive failure alert is
received and the drive is attached to an array controller.
The drive is not configured as part of an array.
OK to replace the drive online.
The drive has failed, and has been placed off-line.
OK to replace the drive online if a predictive failure alert is
received, provided the array is configured for fault tolerance
and all other drives in the array are online.
The drive is online and configured as part of an array.
OK to replace the drive online if a predictive failure alert is
received, provided the array is configured for fault tolerance
and all other drives in the array are online.
The drive is online and configured as part of an array.
OK to replace the drive online if a predictive failure alert is
received, provided the array is configured for fault tolerance
and all other drives in the array are online.
The drive is online and configured as part of an array.
Software Requirement for Intel Servers: Support Software CD
Software Requirement for Alpha Servers: None
1. Verify correct drive carrier support
-
Verify that the server or disk
enclosure supports Wide Ultra2 or Ultra3 SCSI drive carriers. Refer to
the documentation included with the system.
2. Review Important Guidelines
-
When replacing a failed drive, refer to
the documentation included with the server or disk enclosure system to
identify and remove a failed drive. See "Important Guidelines for
Replacing Hot-Pluggable Hard Drives" included on this poster.
3. Remove failed drive
-
Follow the steps shown on this card.
4. Install Hot-Pluggable hard drive
-
Follow the steps shown on this card.
5.Hard Drive Handling Precautions-Hard drives are sensitive electro-
mechanical devices that can be permanently damaged through improper
handling. The packaging provided with a hard drive is designed to
protect it from accidental drops. Compaq recommends that hard drives
remain in their original packaging until installation. Drives should be
handled with care and never dropped, even from short distances.
6. Configuration
-
If this is an upgrade or new installation on a ProLiant-
based system, run the Compaq System Configuration Utility found on
the Software Support CD.
Before You Begin:
CAUTION: Electrostatic discharge can damage electronic components. Be sure you are
properly grounded before beginning this procedure. Refer to the documentation that
came with your computer or contact your Compaq authorized reseller for procedures to
discharge static electricity.
Follow these steps to install the Hot-Pluggable hard drive
into a system.
Installing the Hard Drive
1a
1b
2
1
1
1
2
Remove the failed drive or blank drive bezel from the disk enclosure before
installing a new hard drive.
1a: Removing a blank drive bezel.
1
Press the ejector buttons simultaneously.
2
Pull the blank drive bezel from the disk enclosure system.
1b: Removing a hard drive.
1
Press the ejector button and pivot the lever to full open position.
2
Pull the drive from disk enclosure.
See "Important Guidelines for Replacing Hot-Pluggable Hard Drives" for
more information.
2
2
1
1
Press the ejector button of the hard drive.
2
Pivot the lever into the full open position.
1
2
3
1
Slide the replacement drive into the disk enclosure.
2
The ejector lever must be in the full open position while
installing to ensure a correct latch.
4
When the drive has been fully inserted, close the ejector lever.
The locking hinge must be engaged behind the front panel of the unit.
Important option
To install a 1-inch hard drive into a 1.6-inch drive bay, attach a drive
height converter to the drive assembly. The drive height converter
option is sold seperately. Contact a Compaq authorized reseller for
purchasing information.
Installation Instructions
Snap the drive height converter accessory into place as shown in the
figure below. Proceed with normal installation procedures.
To confirm a correct attachment, the front view of the drive should be
level on both the right and left sides and the fit should be snug.
CAUTION: Do not carry the drive by the drive height converter. If the attachment is not
secure, the drive may fall resulting in damage to the drive. This will void any drive
warranty.

Popular DC Drive manuals by other brands

New Japan Radio NJU6062 quick start guide

New Japan Radio

New Japan Radio NJU6062 quick start guide

Masterflex L Series quick start guide

Masterflex

Masterflex L Series quick start guide

Advanced Control M420 Series Basic Reference Guide

Advanced Control

Advanced Control M420 Series Basic Reference Guide

gefran EXP-D20A6 instruction manual

gefran

gefran EXP-D20A6 instruction manual

REXROTH IndraDrive Project planning manual

REXROTH

REXROTH IndraDrive Project planning manual

AuCom MVH 2.0 Series user manual

AuCom

AuCom MVH 2.0 Series user manual

YASKAWA SI-EN3D Technical manual

YASKAWA

YASKAWA SI-EN3D Technical manual

ABB ACS2000 AFE 1MVA user manual

ABB

ABB ACS2000 AFE 1MVA user manual

SOMFY Sonesse 28 WireFree RTS Li-ion instructions

SOMFY

SOMFY Sonesse 28 WireFree RTS Li-ion instructions

Newport 5600 Series user manual

Newport

Newport 5600 Series user manual

ZIEHL-ABEGG ZAdyn4C MRL Replacement manual

ZIEHL-ABEGG

ZIEHL-ABEGG ZAdyn4C MRL Replacement manual

Eaton BACnet MS/TP OPTCJ user manual

Eaton

Eaton BACnet MS/TP OPTCJ user manual

GE Ecomagination AF-600 FP Programming guide

GE

GE Ecomagination AF-600 FP Programming guide

Danfoss VLT AutomationDrive FC 300 Programming guide

Danfoss

Danfoss VLT AutomationDrive FC 300 Programming guide

BSS Audio FDS-334T manual

BSS Audio

BSS Audio FDS-334T manual

GFA ELEKTROMAT SI 25.15-30,00 Ex installation instructions

GFA

GFA ELEKTROMAT SI 25.15-30,00 Ex installation instructions

Siemens MICROMASTER 440 GX Maintenance instructions

Siemens

Siemens MICROMASTER 440 GX Maintenance instructions

Xinje VB3 user manual

Xinje

Xinje VB3 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.