Anti-legionella
NO
Anti-legionella function provides wee ly heat sterilization of the
HUW tan . It requires connection of the NANO module.
Boiler hyster.
2°C
Boiler hysteresis. The burner turns on when the boiler set
temperature will decrease below the value set here. It switches
off after reaching the set temperature. Setting range 1..5°C .
HUW loading
hyster. 3°C
HUW loading hysteresis. Loading the HUW tan starts when the
water set temperature falls by the value set here. It ends after
reaching the set temperature. Setting range1..10°C
CH excess to
load HUW 5°C
While loading HUW tan the temperature maintained in the boiler
is higher than the set HUW temperature by the value set in this
parameter. Setting range 0..20°C
Pump run
time 60s
Pumps run provide heat collection accumulated in the boiler body
limiting at the same time increase in temperature of the boiler in
case of reducing the load. Setting range 0..600s.
HUW off with
NANO 1 NO
This parameter determines whether HUW operation is to be
turned off when the user sets for NANO with address 1 HOLIDAY
mode.
Operating state
CH and HUW pumps
Operating state
•CH and HUW PUMPS – system operation with two pumps (Fig. 1)
•P.+ DISTRIBUTOR - system operation with one pump and
distributor CH/HUW (Fig. 2)
Oper. mode RS485
MASTER
RS485 serial interface operating mode. The controller uses the
protocol C14. One controller in such a networ must be in MASTER
mode. Others must operate in SLAVE mode.
A RESS in NET
1
Controller address in the net. Two controllers of the same class
cannot have the same address.
Off-season
runs on
Off-season runs protect pumps against bloc ing due to deposition
in them sediments and contaminants. They consist of switching
CH and HUW pumps every 3 days for 15 seconds.
Service parameters
Service parameters are available with code 199.
Max. boiler
set temp. 85°C
Maximal boiler set temperature.
Setting range 80..95°C .
Min. boiler
set temp. 40°C
Minimalna temperatura zadana otła.
Setting range 30..80°C .
Anti-legionella
Anti-legionella function must be activated in „Antilegionella” parameter. Sterilization
is carried out by trying to increase the temperature of the HUW tan to 72°C. The
controller does this every wee .
8 User manual B750 T u2x, version 1, February 2017