Condair Cube User manual

QUICK-START GUIDE
Condair Cube
Air Quality Measuring Device:
– CO
– Relative Humidity
– TemperatureMade in Switzerland
2603143-0 EN 2110
Thank you for purchasing the Condair Cube.
The Condair Cube uses a higly sensitive sensor to detect CO, relative humidity (% RH) and temperature in
the ambient environment.
Before working with the measuring device, please read this Quick-Start Guide carefully!
– The Condair Cube is intended for indoor use only. Any other use is considered as non-intended use and
may cause the Condair Cube to display deviating measuring results. Any use not in accordance with the
intended purpose will void the warranty.
– By following the Quick-Start Guide, you will also avoid damaging the device and running the risk of your
legal rights to claim for defects due to misuse. We accept no liability for damage caused by non-observance
of this Quick-Start Guide.
– We are not liable for incorrect measured values and consequences that may result from misuse.
For your safety
– Do not use the product in any other way than described in these instructions.
–
Important notes on product safety
– Do not expose the device to extreme temperatures, humidity, vibrations and shocks. Clean the device with
a soft, slightly damp cloth. Do not use scouring agents or solvents!
PRODUCT OVERVIEW
Components: 1 measuring device and USB charging cable. Optional: Micro SD card (not supplied)
Ventilation slots
Slot for Micro SD card
Sensor
Housing
Display/Touchscreen
Button 1
Button 2 LED (green)
Power button
USB charging cable port
STARTING THE CONDAIR CUBE
1. Switch on the Condair Cube: To do this, press the power button inside the cavity on the lower, left
side of the cube (see product overview). Fully charge the device.
Note: If the Condair Cube is plugged in via the USB cable, it switches on automatically.
2. Place the Condair Cube upright in the room, where you want to check the room air, so that the sensor, on
the back of the Cube, is free from obstruction and the excess heat can escape through the ventilation slots.

3. The Condair Cube displays the exact values of CO2and relative humidity after 3 minutes. However,
it needs an adjustment time of approx. 20 minutes until all values are displayed accurately, especially
the temperature.
4. Calibration: For accurate COmeasurements, the Condair Cube must be calibrated during initial start-up,
Manual Calibration
Place the sensor outdoors, for example outside the window in fresh air.
Menu → Settings → Calibration CO2 → Press “Start”
CO
2
10:15
21.08.2021 85%
After approx. 6 minutes – displayed graphically with a bar graph and percentage – the calibration is com-
pleted; the cube automatically switches to the main page.
Important! Check the COvalue. If it is within the range of 400 +/-25 ppm, the calibration was successful.
If the value is above or below this, repeat the calibration!
Auto calibration
This function can be activated via the settings. It’s important here that:
– the sensor is in operation as permanently as possible and
– it is exposed to fresh outside air for approx. 10 minutes at least once a week.
During auto-calibration, the lowest measured value over one week is taken as the reference value and
recalibrated to 400 ppm.
Menu → Settings → Calibration CO2 → Auto calibration → enable or disable
If the Condair Cube is not operated consistently, it is recommended to deactivate the auto calibration and
to perform a manual calibration when using the Condair Cube.
MAIN SCREEN VIEW
Time
Date
ppm
%RH °C
CO
2
10:15
21.08.2021 85%
ppm
%RH °C
28 21
1092
CO
2
CO2value
Battery status
Menu bar
Humidity
value Temperature
value
Time/Date: Current data
Battery status: State of charge: 0-100 %
CO2value: Current COcontent in the air, in ppm
(Parts per Million).
Temperature value: Current temperature in °C (Celsius)
Humidity value: Current relative humidity of the ambient air,
in % RH
Menu bar: Access to submenus. Health chart, settings,
past readings
Button 1: Turn on screen, increase brightness
Button 2:
LED: When the display is darkened via button 2, the
LED lights up green as an operating indicator.

TRAFFIC LIGHT DISPLAY OF THE MEASURED VALUES
Green Yellow Red
CO2content of the
ambient air Relative humidity Temperature
Circle green:
OPTIMAL VALUES
Circle yellow:
CAUTION!
or
or
Circle red:
CRITICAL VALUES > 1'200 ppm
APPLICATION OVERVIEWS
View health chart View historical readings
CO2display in bar format
Currently measured value
Range "healthy"
Range "acceptable"
Temperature
Air humidity
Currently measured value
Historical measured values
The ranges “healthy”– green diamond – “acceptable”
and “critical” are shown in the health chart.
Air quality in the “healthy” range provides increased
health protection and is perceived as pleasant.
Target: The current measured value (red dot) of the
room air is in the inner green diamond and thus in
the “healthy” range.
If the COcontent in the bar view above is outside
the green range, the room should be ventilated.
Display of the 4-hour history of the values - here, for
example, the temperature readings.
For every 10 minutes of measurement, the mea-
sured average value is displayed as a bar and colored
If the bar is yellow or red, the temperature was too
low or too high on average during the last 10 minutes
considering the health chart.
Use the arrow keys on the side of the circle to access
the other measured values: COand % RH.

SETTINGS
Alarm setting
Calibration CO2
Time and data settings
The 3 icons lead to the submenus:
– Alarm settings
– Calibration CO
– Time and date settings
Tap once on the respective icon to enter the submenus.
The internal RTC (RealTimeClock) ensures that the
time and date continue to run for approx. 2 months
Set the desired time/date using the up/down arrow keys:
hh:mm:ss (Hours:Minutes:Seconds) resp.
The OPERATING INSTRUCTIONS of the Condair Cube can be found in our
website, at: https://www.condair.ch/privatkunde/condair-cube
Here you can nd more information about the additional options and
capabilities of the Condair Cube:
– SD card as memory card for measured values and further processing of the data
– Power bank – any power bank with 5 V USB connection
– Display on large screen
– Disposal/Recycling
– Product specication
– Tips and further recommendations
CH94/0002.00
Outer packaging and instructions
Copyright Notice:
© Condair Group AG, all rights reserved.
Condair Group AG hereby declares that the Condair Cube unit is in
compliance with the essential requirements and other relevant provi-
sions of Directive 2014/53/EU and ROHS 2011/65/EC. The original
EU Declaration of Conformity can be found at https://www.condair.ch/
privatkunde/condair-cube/
Condair Group AG
info@condair.com, www.condairgroup.com
Liability Notice
Condair Group AG does not accept any liability due to incorrect installation or operation of the equipment or
due to the use of parts/components/equipment that are not authorised by Condair Group AG.
Other manuals for Cube
1
This manual suits for next models
1
Other Condair Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Magnaflux
Magnaflux UVe-LUX operating manual

jacarta
jacarta SP8 user manual

Honeywell
Honeywell QA 10 DN 25 G I instruction manual

Binsfeld
Binsfeld TorqueTrak Revolution user guide

Siemens
Siemens Sitrans FUG1010 Operating instruction

PCB Piezotronics
PCB Piezotronics Y3713E112G Installation and operating manual