Condari CONDARY CON 60L Assembly Instructions

UNDERCUPBOARD
INSTALLATION & USER
INSTRUCTIONS
2021

Qasair Rangehoods Installation Instructions2

Qasair Rangehoods Installation Instructions 3
Important Information
Cutout Dimensions
Duct Direction Change Instructions
Instructions for Models
FA
Instructions for Models
CON / NDCH / LIS / ETN
Instructions for Models
KEN / WCV
Operation Details, Rangehood Cleaning, Filter Cleaning
Appliance Guarantee
Installation Ideas
Instructions for Models
WES / EAS / GRA
Guarantee Exclusions
6
4
7
8
10
19
24
31
38
37
36
Standard Warranty / Extended Warranty 39

Qasair Rangehoods Installation Instructions4
The installation of Qasair Rangehoods must comply with the information in this booklet. Qasair Rangehoods are
designed and made to work efciently over all domestic cookware available on the Australian market.
It is necessary to allow electrical disconnection of the rangehood after installation.
This may be achieved by either.
a) Installing a power point to an accessible area for the rangehood.
b) Incorporating a wall switch to the xed wiring that supplies the rangehood.
Clearance from cooktop to Rangehood
For electric hot plate cooktops
Please follow the manufacturers instructions / recommendations.
For Induction cooktops
Induction cooktops may present problems with condensation on lters of rangehoods.
All Qasair rangehoods installed above an induction cooktop must be installed no less than 750mm between the
induction cooktop and the rangehood, with the exception of the Eastmore (EAS) rangehood which can be installed
no less than 600mm and the Grampian which can be installed no less than 650mm. Undermount (NDCH), Conley
(CON) and Foldaway (FA) rangehoods are not suitable for induction cooktops.
For gas cooktops
All Qasair Rangehood installations over a gas appliance must comply with (AS/NZS 5601.1).
The requirements for the installation of Gas Appliances (AS/NZS 5601.1) states that the clearance between
the highest part of the burner of a gas cooking appliance and a Rangehood be no less than 600mm. If the gas
appliance is designed for use without a cooking vessel (as dened by AS/NZS 5601.1), then the clearance from the
cooking surface to the grease lter shall be no less than 1200mm.
The recommendation for Qasair wallmount rangehoods is that they be installed between 700 to 800mm above the
highest part of the burner. When the rangehood is installed in a galley or partially enclosed kitchen the rangehood
can be installed between 900 to 1000mm above the highest part of the burner.
Qasair island rangehoods should not be installed any higher than 800mm above the highest part of the burner as
any movement around the bench will result in fumes being drawn out from the catchment area of the rangehood
with the exception of the Thermidor and Liverpool which for aesthetic reasons is installed ush with the ceiling.
Ducting
For all your ducting requirements please refer to the Qasair Rangehoods Ducting Pieces brochure included
with your Rangehood or please consult our website where it can be viewed or downloaded.
1. Every Qasair rangehood must be ducted to the outside atmosphere by the use of zinc-alume duct or
non-porous and non-ammable materials. Do not use of any type of exible ducting or plastic PVC piping.
Rangehoods must not be vented into a wall cavity or a ceiling space. Externally ducting the rangehood prevents
a build up of grease, which can be a re risk. Ensure the external outlet vent does not restrict the airow in any
way, as this may result in reduced performance.
2. Qasair rangehoods must be ducted in duct work equivalent to the outlet of the rangehood ie: The cross
sectional area of the rangehood outlet and the duct work must be equal. Do not reduce the duct size or have
sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from Condari is available to
ensure optimum performance. Always use non-ammable materials to minimise the risk of re in the duct.
3. Ensure all ducting pieces are correctly tted and sealed with either duct tape or silicone to ensure that fumes
do not escape into the ceiling space and seep into living areas through vents or light ttings.
IMPORTANT INFORMATION

Qasair Rangehoods Installation Instructions 5
Other Important Information
1. Always adequately ventilate the room when the rangehood is in use at the same time as appliances burning gas
or other fuels.
2. WARNING: Incorrect venting will result in additional noise and a reduction in efciency. Exhaust air must not be
discharged into any chimney or ue, which may carry combustible products from other sources.
a) Do not discharge the air-ow from the rangehood into a ue used for exhausting fumes
from burning gas or fuel;
b) For cleaning purposes please refer to page 36 of installation instructions for stainless steel;
c) If cleaning is not carried out in accordance with the instructions as listed on page 36, there may be an
increased risk of re;
d) Some parts of the rangehood may become hot when cooking;
e) This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
3. The installation and tting of the rangehood should be done in such a way that will allow the unit to be removed
if service is required. Additional costs incurred in the removal of wall tiles, damage to walls or bench tops are not
covered by warranty.
4. To reduce the risk of xing screws coming in contact with live parts, do not drill or screw into the rangehood.
Live wires are encapsulated where possible to prevent user contact. If necessary drill from the inside out and
only through single sheet material.
5. NOTE: Condari recommend an air movement of between 1000 to 1400 cubic metres per hour over an indoor
barbecue, depending on the length of the duct run. Ensure a twin motor unit is installed over indoor barbecues
for optimum results. Barbecues should be positioned under the centre of the hood where the fans are mounted
and not near the outer edges where leakage may occur.
6. The lights in the rangehoods are LED and come with a night light except for D400L-1 and SEN400L-1.
7. Please contact Condari to arrange an authorised technician to replace any cracked protective glass shields for
the LED lights.
8. If the supply cord is damaged, an authorised service centre or licensed electrician must replace it.
9. Do not ambé under the rangehood.
10. Qasair domestic rangehoods must not to be used over barbecues approved for outdoor use only. Condor make a
range of rangehoods specically for outdoor barbecues in alfresco areas under the Condor name.
11. Condor can manufacture rangehoods to be used over commercial cookers in domestic applications.
12. NOTE: All information is correct at the time of print, as standards vary over time please ensure all requirements
meet the latest standards / codes and regulations.

Qasair Rangehoods Installation Instructions6
INSTALLATION INSTRUCTIONS
CUTOUT DIMENSIONS
MODEL HOOD SIZE BASE SIZE
PROUD MOUNT
CUT OUT DIMENSION
FLUSH MOUNT
CUT OUT DIMENSION
CON 60L 244 x 580 280 x 600 258 x 585 283 x 603
CON 80L 244 x 780 280 x 800 258 x 785 283 x 803
ETN 600L 344 x 580 380 x 600 355 x 585 383 x 603
ETN 900L 344 x 880 380 x 900 355 x 885 383 x 903
ETN 1200L 344 x 1180 380 x 1200 355 x 1185 383 x 1203
GRA 60L 364 x 560 400 x 600 370 x 565 403 x 603
GRA 90L 364 x 880 400 x 900 370 x 885 403 x 903
GRA 100L 364 x 980 400 x 1000 370 x 985 403 x 1003
GRA 120L 364 x 1160 400 x 1200 370 x 1165 403 x 1203
KEN 1000L 564 x 980 600 x 1000 570 x 985 603 x 1003
KEN 1300L 564 x 1280 600 x 1300 570 x 1285 603 x 1303
KEN 1600L 564 x 1580 600 x 1600 570 x 1585 603 x 1603
LIS 500L 393 x 480 430 x 500 400 x 485 433 x 503
LIS 800L 393 x 780 430 x 800 400 x 785 433 x 803
LIS 900L 393 x 870 430 x 900 400 x 885 433 x 903
LIS 1000L 393 x 980 430 x 1000 400 x 985 433 x 1003
LIS 1200L 393 x 1180 430 x 1200 400 x 1185 433 x 1203
LIS 1500L 393 x 1480 430 x 1500 400 x 1485 433 x 1503
NDCH 90L 244 x 880 280 x 900 258 x 885 283 x 903
NDCH 100L 244 x 980 280 x 1000 258 x 985 283 x 1003
NDCH 120L 244 x 1180 280 x 1200 258 x 1185 283 x 1203
WES 60L / EAS 60L 294 x 565 330 x 600 300 x 570 333 x 603
WES 80L / EAS 80L 294 x 780 330 x 800 300 x 785 333 x 803
WES 90L / EAS 90L 294 x 880 330 x 900 300 x 885 333 x 903
WES 100L / EAS 100L 294 x 980 330 x 1000 300 x 985 333 x 1003
WES 120L / EAS 120L 294 x 1180 330 x 1200 300 x 1185 333 x 1203
WCV 1000L 564 x 980 600 x 1000 570 x 985 603 x 1003
WCV 1300L 564 x 1280 600 x 1300 570 x 1285 603 x 1303
WCV 1600L 564 x 1580 600 x 1600 570 x 1585 603 x 1603

Qasair Rangehoods Installation Instructions 7
DUCT DIRECTION CHANGE INSTRUCTIONS
Before installing your rangehood check whether it has the fan mounted for back or top ducting.
For top ducting, the unit will have the air outlet at the top, and for back ducting, the unit will have the air outlet at the
back.
To change from top to back or back to top, proceed as follows:
Duct direction for ETN, NDCH and CON models
The motor shown is fitted to the back plate (P) and this plate is attached to the rangehood by screws (S). To change
from top to back, remove the filters, unplug fan(s). Undo all the screw (S), carefully remove the plate and turn it around
so the motor points out the way required. Fit and reconnect the fan(s), and fit all the screws again and tighten.
Duct direction for LIS / FA / EAS / WES / GRA and KEN
To change the duct direction, proceed as follows:
1. Remove the screws from the fan access panel and remove access panel (for EAS and WES models only).
2. Disconnect fan(s).
3. Unscrew the 2 x 7mm screws (B) fixing the fan to the hood. Remove fan entirely. Repeat for each fan.
4. Rotate the fan assembly and re-install so that the air outlet meets with the rangehood outlet hole through which
you are going to vent (top or back).
5. Replace the 2 x 7mm screws holding each fan.
6. Reconnect the fan(s)
7. Refit the fan access panel (for EAS and WES models only).
Rear Duct Position
Top Duct Position

Qasair Rangehoods Installation Instructions8
INSTALLATION INSTRUCTIONS
• FA
1. The rangehood is designed to be fitted within joinery and can be installed by inserting screws in the three holes
provided on each side, or to the top or back by drilling your own mounting holes as required.
2. When installed, cover the access holes to the side fixing screws with the plastic plugs supplied.
3. Fit filters.
4. Install front panel to suit as per your kitchen design.
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.

Qasair Rangehoods Installation Instructions 9
Door Width
Condari Pty Ltd. Page 1 of 1
Version: D 19/03/2021F
Body Width
Model
Motor Qty
Light Centres
Light Qty
Nightlight
LED Light
Filter Qty
Model
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
FA 60L-1 FA 90L-2FA 90L-1FA 60L-1FA 90L-2FA 90L-1
598mm
Centre
2
573.4mm
1
Cool
YES
1
274mm x 290mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
898mm
873.4mm
1
Cool
YES
2
350mm
2
898mm
873.4mm
2
Cool
YES
2
350mm
2
424mm x 290mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
424mm x 290mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
UM-xy** Series
Foldaway
Technical Specification Sheet
FA Undercupboard
Power Entry
300
449
20
444
20
D
oorW
idth
BodyW
idth
235
235
D
oorW
idth
BodyW
idth
Power Entry
This view is shown
with door in closed
position.
200
110
10
235235
100
9
FOLDAWAY - FA

Qasair Rangehoods Installation Instructions10
INSTALLATION INSTRUCTIONS
• CON
• NDCH
• LIS
• ETN
1. Loosen screws A and B by turning anti-clockwise.
2. Turn screw ‘D’ anti-clockwise to extend the outer spring bracket.
3. Insert rangehood into cut out and turn screw ‘C’ clockwise to align rangehood with cupboard base.
4. Do not over tighten.
5. Tighten screw ‘A’ by turning clockwise to lock xing bracket.
6. Fit off ductwork as required.
7. To remove rangehood, turn screw ‘D’ clockwise.
Models: ETN
NDCH
Models: LIS
CON
RANGEHOOD SPRING BRACKETS
MOUNTING POSITION
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.
Flush Mount ( 1 : 4 )Proud Mount ( 1 : 4 )
AAB B
Cupboard
Front of Rangehood
FLUSH MOUNT
Cupboard
Front of Rangehood
PROUD MOUNT
12
12

Qasair Rangehoods Installation Instructions 11
Motor Box /
Flue Width
Condari Pty Ltd. Page 1 of 1
Version: D 19/03/2021FF
Body Width
Model
Motor Qty
Light Centres
Light Qty
Nightlight
LED Light
Filter Qty
Model
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
CON 60L-1 CON 80L-2CON 80L-1CON 60L-1CON 80L-2CON 80L-1
600mm
Centre
2
580mm
1
Cool
YES
1
269mm x 250mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
800mm
780mm
1
Cool
YES
2
379mm
2
800mm
780mm
2
Cool
YES
2
379mm
2
379mm x 157mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
379mm x 157mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
UM-xy** Series
Conley
Technical Specification Sheet
CON Undercupboard
PMS 539C
R= 0
G= 48
B= 73
PMS 5503C
R= 156
G= 197
B= 202
Power Entry
BodyW
idth
M
otorBox W
idth
10
40
BodyW
idth
M
otorBoxW
idth
280
360
12
10
25
30
Power Entry
10
110
9
18 18
244
235
235235
100
CONLEY - CON

Qasair Rangehoods Installation Instructions12
Undermount
Technical Specification Sheet
NDCH Undercupboard
Motor Qty
LED Light
Nightlight
Model
Body Width
Motor Box /
Flue Width
Light Qty
Light Centres
Filter Qty
Cool
YES
1
880mm
900mm
NDCH 90L-1
2
Page 1 of 2
All-thread
Fixing Centres
Condari Pty Ltd.
PowderKote
Available
2
770mm
NDCH 90L-2
2
770mm
880mm
Minimum Height
(H =)
Model
Maximum Height
(H =)
Corner Type Square
N/AN/A
Version: D 19/03/2021F
Square
Electrical Connection
N/A
N/A
340mm x 260mm
YES
NDCH 90L-1 NDCH 90L-2
Cool
YES
900mm
2
2
10 Amp Lead
YES
340mm x 260mm
10 Amp Lead
N/A
Filter Size
Conversion
Top/Back Back/Top
N/A
N/A
N/A
UM-xy** Series
Power entry location
is the same for all
NDCH models.
280
360
M
otorBox W
idth
M
otorBoxW
idth
235
2530
235
100
235
Body W
idth
Body W
idth
110
10
10
12
1818
244
9
110
UNDERMOUNT - NDCH

Qasair Rangehoods Installation Instructions 13
Undermount
Technical Specification Sheet
NDCH Undercupboard
2
Light Centres
Filter Qty
860mm
Motor Box /
Flue Width
Body Width
Motor Qty
Nightlight
Light Qty
LED Light
1060mm
Cool
NDCH 120L-2
1180mm
YES
2
NDCH 100L-2
Cool
980mm
Model
2
All-thread
Fixing Centres
Page 2 of 2
Version: D 19/03/2021F
Condari Pty Ltd.
2Corner Type
Maximum Height
(H =)
2
1000mm 1200mm Filter Size
Electrical Connection
Minimum Height
(H =)
Square
N/A
N/A N/A
Square
Model
PowderKote
Available N/A
N/A
10 Amp Lead
N/A
N/A
YES
479mm x 260mm
N/A
NDCH 100L-2
YES
NDCH 120L-2
10 Amp Lead
379mm x 260mm
YES
2
Conversion
Top/Back Back/Top
UM-xy** Series
Power entry location
is the same for all
NDCH models.
M
otorBox W
idth
Body W
idth
M
otorBoxW
idth
BodyW
idth
2530
235
100
235
235
235
100
110
9
244
18 18
12
10 10
110
360
280
UNDERMOUNT - NDCH

Qasair Rangehoods Installation Instructions14
Motor Box /
Flue Width
Condari Pty Ltd. Page 1 of 3
Version: D 19/03/2021F
Body Width
Model
Motor Qty
Light Centres
Light Qty
Nightlight
LED Light
Filter Qty
Model
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
LIS 500L-1 LIS 800L-2LIS 800L-1LIS 500L-1LIS 800L-2LIS 800L-1
500mm
Centre
1
480mm
1
Cool
YES
1
459mm x 290mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
800mm
780mm
1
Cool
YES
2
380mm
2
800mm
780mm
2
Cool
YES
2
380mm
2
379mm x 290mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
379mm x 290mm
YES
10 Amp Lead
N/A
N/A
N/A
N/A
Square
UM-xy** Series
Lismore
Technical Specification Sheet
LIS Undercupboard
PMS 539C
R= 0
G= 48
B= 73
PMS 5503C
R= 156
G= 197
B= 202
Power entry location
is the same for all
LIS models.
M
otorB
oxW
idth
BodyW
idth
1
15
50
235
235
315
110
20
20
110
400
12
20 20
393
430
9
75
150
M
otorB
oxW
idth
BodyW
idth
235
235
100
235235
100
LISMORE - LIS

Qasair Rangehoods Installation Instructions 15
Lismore
Technical Specification Sheet
LIS Undercupboard
Motor Box /
Flue Width
Body Width
Light Centres
LED Light
Light Qty
Motor Qty
Filter Qty 2
424mm
Model Model LIS 900L-2
2
480mm
Nightlight
N/A
Minimum Height
(H =)
Page 2 of 3Condari Pty Ltd.
All-thread
Fixing Centres
PowderKote
Available
Maximum Height
(H =)
Corner Type
Conversion
Top/Back Back/Top
Electrical Connection
YES
N/A
10 Amp Lead
N/A
Square
N/A
Version: D 19/03/2021F
N/A
424mm x 290mm
2
LIS 1000L-2
2
Cool
YES
LIS 900L-2
900mm
870mm
210 Amp Lead
YES
479mm x 290mm
LIS 1000L-2
N/A
Square
Cool
YES
980mm
1000mm
2
Filter Size
N/A
N/A
UM-xy** Series
Power entry location
is the same for all
LIS models.
150
75
9
430
393
2020
12
400 110
20 20
110
315
M
otorBox W
idth
BodyW
idth
50
115
235
235
100
235
100
235
M
otorBoxW
idth
BodyW
idth
235
100
235
235
100
235
LISMORE - LIS

Qasair Rangehoods Installation Instructions16
Minimum Height
(H =)
Filter Size
Model
Conversion
Top/Back Back/Top
N/A
LIS 1200L-3
Electrical Connection
Page 3 of 3
Body Width
Motor Box /
Flue Width
Motor Qty
Model
Nightlight
Filter Qty
Light Qty
Version: D 19/03/2021F
Light Centres
Maximum Height
(H =)
Corner Type
Condari Pty Ltd.
1180mm
1200mm
LIS 1200L-2
4
LED Light
580mm
YES
N/A
N/A
10 Amp Lead
290mm x 290mm
LIS 1200L-2
N/A
LIS 1500L-3
N/A
YESYES
2
N/A
290mm x 290mm 365mm x 290mm
All-thread
Fixing Centres
PowderKote
Available
LIS 1500L-3
1500mm
1480mm
3
3
1200mm
1180mm
452mm
4
YES
4
Cool Cool
3
2
LIS 1200L-3
N/A
Square
YES
10 Amp Lead10 Amp Lead
YES
N/A
Square
N/A
N/A
N/A
Square
N/A
580mm
2
Cool
UM-xy** Series
Lismore
Technical Specification Sheet
LIS Undercupboard
Power entry location
is the same for all
LIS models.
M
otorBox W
idth
315
110
20
20
110
400
12
20 20
393
430
9
75
150
Body W
idth
115
50
235
100
235
235
100
235
M
otorBoxW
idth
BodyW
idth
235
100
235
100
235
235
100
235
100
235
LISMORE - LIS

Qasair Rangehoods Installation Instructions 17
Eaton
Technical Specification Sheet
ETN Undercupboard
Motor Qty
LED Light
Nightlight
Model
Body Width
Motor Box /
Flue Width
Light Qty
Light Centres
Filter Qty
Cool
YES
1
580mm
600mm
ETN 600L-1
2
Page 1 of 2
All-thread
Fixing Centres
Condari Pty Ltd.
PowderKote
Available
2
800mm
ETN 900L-1
1
520mm
880mm
Minimum Height
(H =)
Model
Maximum Height
(H =)
Corner Type Square
N/AN/A
Version: F 01/10/2021F
Square
Electrical Connection
N/A
N/A
479mm x 290mm
YES
ETN 600L-1 ETN 900L-1
Cool
YES
900mm
1
2
10 Amp Lead
YES
379mm x 290mm
10 Amp Lead
N/A
Filter Size
Conversion
Top/Back Back/Top
N/A
N/A
N/A
UM-xy** Series
Power entry location
is the same for
all ETN models.
235
20
17
10
290
12
380
235
M
otorBox W
idth
BodyW
idth
M
otorBodyW
idth
BodyW
idth
110
9
10
18 18
344
EATON - ETN

Qasair Rangehoods Installation Instructions18
Eaton
Technical Specification Sheet
ETN Undercupboard
2
Light Centres
Filter Qty
800mm
Motor Box /
Flue Width
Body Width
Motor Qty
Nightlight
Light Qty
LED Light
1060mm
Cool
ETN 1200L-2
1180mm
YES
2
ETN 900L-2
Cool
880mm
Model
2
All-thread
Fixing Centres
Page 2 of 2
Version: F 01/10/2021F
Condari Pty Ltd.
3Corner Type
Maximum Height
(H =)
2
900mm 1200mm Filter Size
Electrical Connection
Minimum Height
(H =)
Square
N/A
N/A N/A
Square
Model
PowderKote
Available N/A
N/A
10 Amp Lead
N/A
N/A
YES
340mm x 290mm
N/A
ETN 900L-2
YES
ETN 1200L-2
10 Amp Lead
379mm x 290mm
YES
2
Conversion
Top/Back Back/Top
UM-xy** Series
Power entry location
is the same for
all ETN models.
20
17
100
235235
10 10
290
12
380
M
otorBoxW
idth
M
otorBoxW
idth
BodyW
idth
100
235235
110
9
B
ody W
idth
18 18
344
EATON - ETN

Qasair Rangehoods Installation Instructions 19
INSTALLATION INSTRUCTIONS
• KEN
• WCV
1. Remove inner side cover panels by removing screws at top of panel, from the inside of the rangehood to allow
access to spring brackets for adjustments.
2. Loosen screws A and B by turning anti-clockwise.
3. Turn screw ‘D’ anti-clockwise to extend the outer spring bracket.
4. Insert rangehood into cut out and turn screw ‘C’ clockwise to align rangehood with cupboard base.
5. Do not over tighten.
6. Tighten screw ‘A’ by turning clockwise to lock xing bracket.
7. Fit off ductwork as required.
8. To remove rangehood, turn screw ‘D’ clockwise.
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.
Models: KEN
RANGEHOOD SPRING BRACKETS
MOUNTING POSITION
Flush Mount ( 1 : 4 )Proud Mount ( 1 : 4 )
AAB B
Cupboard
Front of Rangehood
FLUSH MOUNT
Cupboard
Front of Rangehood
PROUD MOUNT
12
12

Qasair Rangehoods Installation Instructions20
KEN 1300L-3KEN 1000L-2
Corner Type
Condari Pty Ltd.
Maximum Height
(H =)
PowderKote
Available
Minimum Height
(H =)
Electrical Connection
Conversion
Top/Back Back/Top
Filter Size
ModelKEN 1300L-3
All-thread
Fixing Centres
KEN 1000L-2
Body Width
Motor Box /
Flue Width
Motor Qty
LED Light
Light Centres
Filter Qty
Model
Nightlight
Light Qty
Page 1 of 2
Version: E 01/10/2021F
2
Cool
YES
2
580mm
3
1000mm
980mm
N/A
N/A
N/A
Square
10 Amp Lead
N/A
YES
422mm x 290mm
N/A
N/A
N/A
Square
10 Amp Lead
N/A
YES
422mm x 290mm
KENT
Technical Specification Sheet
KEN Undercupboard
4
580mm
2
YES
Cool
3
1280mm
1300mm
UM-xy** Series
Power entry location
is the same for all
KEN models.
BodyW
idth
484
564
600
12
700
20
20
422
400
25
M
otorBoxW
idth
M
otorBoxW
idth
Body W
idth
100
235235
235235
100
105
105
235235
235
100100
235235
235
100100
Recommended Installation height 800mm above the cooking surface
of an indoor compliant open flame BBQ or high powered Cookware.
503
KENT - KEN
This manual suits for next models
33
Table of contents
Other Condari Ventilation Hood manuals