Connect Tech BLUESTORM UNIVERSAL PCI User manual

BlueStorm Universal PCI
User Manual
Contact Information:
Connect Tech Inc.
42 Arrow Road
Guelph, Ontario, Canada N1K 1S6
Tel: 519-836-1291 (International)
800-426-8979 (Canada & USA)
Fax: 519-836-4878
Email: [email protected]
URL: www.connecttech.com
CTIM-00015 Revision 0.13 December 6, 2016
Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
2 Revision 0.13
Limited Lifetime Warranty
Connect Tech Inc. provides a lifetime warranty for all*Connect Tech Inc. products. Should this
product, in Connect Tech Inc.'s opinion, fail to be in good working order during the warranty
period, Connect Tech Inc. will, at its option, repair or replace this product at no charge, provided
that the product has not been subjected to abuse, misuse, accident, disaster or non Connect Tech
Inc. authorized modification or repair.
You may obtain warranty service by delivering this product to an authorized Connect Tech Inc.
business partner or to Connect Tech Inc. along with proof of purchase. Product returned to
Connect Tech Inc. must be pre-authorized by Connect Tech Inc. with an RMA (Return Material
Authorization) number marked on the outside of the package and sent prepaid, insured and
packaged for safe shipment. Connect Tech Inc. will return this product by prepaid ground
shipment service.
The Connect Tech Inc. lifetime warranty is defined as the serviceable life of the product. This is
defined as the period during which all components are available. Should the product prove to be
irreparable, Connect Tech Inc. reserves the right to substitute an equivalent product if available
or to retract lifetime warranty if no replacement is available.
The above warranty is the only warranty authorized by Connect Tech Inc. Under no
circumstances will Connect Tech Inc. be liable in any way for any damages, including any lost
profits, lost savings or other incidental or consequential damages arising out of the use of, or
inability to use, such product.
*Xtreme/104 Wireless Radio Modems include a one year warranty only.
Copyright Notice
The information contained in this document is subject to change without notice. Connect Tech
Inc. shall not be liable for errors contained herein or for incidental consequential damages in
connection with the furnishing, performance, or use of this material. This document contains
proprietary information that is protected by copyright. All rights are reserved. No part of this
document may be photocopied, reproduced, or translated to another language without the prior
written consent of Connect Tech Inc.
Copyright
1997 - 2016 by Connect Tech Inc.
Trademark Acknowledgment
Connect Tech Inc. acknowledges all trademarks, registered trademarks and/or copyrights
referred to in this document as the property of their respective owners.
Not listing all possible trademarks or copyright acknowledgments does not constitute a lack of
acknowledgment to the rightful owners of the trademarks and copyrights mentioned in this
document.
Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.13 3
Table of Contents
Limited Lifetime Warranty..................................................................................................................2
Copyright Notice................................................................................................................................2
Trademark Acknowledgment...............................................................................................................2
Table of Contents ...............................................................................................................................3
List of Figures..........................................................................................................3
List of Tables ...........................................................................................................4
Customer Support Overview................................................................................................................5
Contact Information............................................................................................................................5
Introduction.......................................................................................................................................6
Features.............................................................................................................................................6
BlueStorm Installation Overview .........................................................................................................7
Hardware Configuration......................................................................................................................7
Interrupts and Memory Address Selection ...................................................................7
RS-422/485 Electrical Interface Configuration.............................................................7
Full Duplex Mode ............................................................................................7
Half Duplex Mode............................................................................................7
Multi-drop Slave Mode.....................................................................................8
Line Bias/Termination......................................................................................8
Jumper Block Diagrams for BlueStorm.................................................................................................8
Jumper Configuration for BlueStorm..................................................................................................11
TxD Control...........................................................................................................12
RxD Control...........................................................................................................12
RxD ± Termination/Bias.......................................................................................12
TxD ± Termination .................................................................................................12
Auto 485................................................................................................................12
Power-On Tri-state (BlueStorm/SP Models Only, Excludes BlueStorm/SP RJ-11) ........13
Connectors and Pinouts.....................................................................................................................13
Hardware Installation........................................................................................................................25
Software/Driver Installation...............................................................................................................25
Specifications...................................................................................................................................25
Operating Environment ...........................................................................................25
PCI Bus Interface....................................................................................................25
Communications.....................................................................................................25
Baud Rates....................................................................................................25
UARTs .........................................................................................................26
Surge Suppression ..................................................................................................26
Optical Isolation .....................................................................................................26
Dimensions............................................................................................................26
Certification.....................................................................................................................................27
List of Figures
Figure 1: BlueStorm/LP Jumper Block Locations (2 Port Models)................................................................ 8
Figure 2: BlueStorm/LP Jumper Block Locations (4 Port Models)................................................................ 9
Figure 3: BlueStorm/LP Jumper Block Locations (8 Port Models)................................................................ 9
Figure 4: BlueStorm/SP Jumper Block Locations (8 Port Models)...............................................................10
Figure 5: BlueStorm/SP Opto Jumper Block Locations (4 Port Models)......................................................10
Figure 6: BlueStorm/SP RJ-11 (8 Port Model)..............................................................................................11
Figure 7: Jumper Configuration Example for 4 Port RS-422/485 BlueStorm/LP Models ...........................12
Figure 8: Jumper Configuration Example for BlueStorm/SP Opto Models ..................................................12
Figure 9: Jumper Configuration Examples for BlueStorm/SP RJ-11 Models...............................................12
Figure 10: BlueStorm External I/O Box Diagram.........................................................................................23
Figure 11: RS-422/485 Wiring Diagrams (BlueStorm/LP and BlueStorm/SP Only)....................................24
Figure 12: RS-422/485 Wiring Diagrams (BlueStorm/SP Opto Only) .........................................................24
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
4 Revision 0.13
List of Tables
Table 1: DB-25 Male Pinouts for BlueStorm/LP (2 Port Connector)...........................................................13
Table 2: HDB-44 Pinouts for BlueStorm/LP (4 Port Connector) .................................................................14
Table 3: VHDCI-68 Female Pinouts for BlueStorm/LP (8 Port Connector).................................................16
Table 4: HDB-78 Pinouts for BlueStorm/SP (8 Port Connector)..................................................................18
Table 5: RJ-45 Pinouts for BlueStorm/SP Opto (4 Port Connector).............................................................20
Table 6: Pinouts and Control Signals for RJ-45 Connectors (BlueStorm/LP RJ-45 Only)...........................20
Table 7: Pinouts and Control Signals for DB-9 and DB-25 Male Connectors (BlueStorm/LP and
BlueStorm/SP Only).......................................................................................................................................21
Table 8: Pinouts and Control Signals for DB-9 Male Connectors (BlueStorm/SP Opto Only) ....................21
Table 9: RJ-11 Pinouts for BlueStorm/SP RJ-11 (Ports 7 and 8 Only)........................................................22
Table 10: Pinouts and Control Signals for RJ-11 Connectors (BlueStorm/SP RJ-11 Only).........................22
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.13 5
Customer Support Overview
If you experience difficulties after reading the manual and/or using the product, contact the
Connect Tech Inc. reseller from which you purchased the product. In most cases the reseller can
help you with product installation and difficulties.
In the event that the reseller is unable to resolve your problem, our highly qualified support staff
can assist you. Our support section is available 24 hours a day, 7 days a week on our website at:
www.connecttech.com/sub/support/support.asp. See the contact information section below for
more information on how to contact us directly. Our technical support is always free.
Contact Information
We offer three ways for you to contact us:
Mail/Courier
You may contact us by letter at:
Connect Tech Inc.
Technical Support
42 Arrow Road
Guelph, Ontario
Canada N1K 1S6
Email/Internet
You may contact us through the Internet. Our email and URL addresses on the Internet are:
www.connecttech.com
Note:
Please go to the Download Zone or the Knowledge Database in
the Support Center on the Connect Tech website for product
manuals, installation guides, device driver software and
technical tips.
Submit your technical support questions to our customer
support engineers via the Support Center on the Connect Tech
website.
Telephone/Facsimile
Technical Support representatives are ready to answer your call Monday through Friday, from
8:30 a.m. to 5:00 p.m. Eastern Standard Time. Our numbers for calls are:
Telephone: 800-426-8979 (North America only)
Telephone: 519-836-1291 (Live assistance available 8:30 a.m. to 5:00 p.m. EST
Monday to Friday)
Facsimile: 519-836-4878 (on-line 24 hours)
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
6 Revision 0.13
Introduction
Connect Tech Inc. presents BlueStorm/LP/SP/SP Opto and SP RJ-11.These high-speed multi-
port communication adapters are designed for Low Profile (LP) and Standard Profile (SP) PCI
compatible computers. BlueStorm cards provide you with up to eight high performance serial
ports and baud rates up to 1.8432 Mbps that are compatible with any standard serial
communications application.
BlueStorm cards are fully PCI compliant. Simply install your card into an available PCI slot in
your computer and with Plug and Play installation and the hardware setup is complete.
BlueStorm cards are an ideal solution for multi-port serial communications in applications such
as Point of Sale; Industrial Process Control, Office Automation and Data/Telecommunications.
They allow easy attachment of peripherals such as barcode scanners, receipt printers, card
readers, testing and monitoring equipment, modems, printers and any other device requiring
serial communications.
Features
Two, four or eight high performance asynchronous serial ports in various RS-232 and/or
RS-422/485 electrical interface configurations.
Baud rates up to 921.6 Kbps (RS-232) and 1.8432 Mbps (RS-422/485) using PCI UARTs
with 64 bytes of TxD/RxD FIFO buffers.
Support for three RS-422/485 modes: full duplex, half duplex and multi-drop slave.
Each port can be configured independently (baud rate, parity, data and stop bits).
DB-9 male fan-out cable (custom cable solutions also offered).
Six RJ-11 connectors provide +12 VDC or +5 VDC output on pin 6 with a current limit of
300 mA (BlueStorm/SP RJ-11 model only).
Optional multi-strike surge suppression on all signals, all ports (select models only).
PCI compliant - with Plug and Play installation.
QNX 4.X/6.X, Windows 2000/CE/NT/XP/XPe/XP 64-Bit/Server 2003/Server 2003 64-
Bit,Vista, VxWorks, Ardence RTX and Linux compatible (contact Connect Tech for most
current list)
Your BlueStorm product consists of the following components:
A BlueStorm adapter
An additional low/standard height chassis bracket ( available on LP models only)
One of the following; DB-9 fan-out cable, approximately 12 in./30.5 cm long, a DB-9
external I/O box , approximately 4ft./122 cm long, or a DB-25 fan-out cable, approximately
12in./30 cm long (optional)
BlueStorm device drivers and documentation CD
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.13 7
BlueStorm Installation Overview
There are three stages to installing your BlueStorm card:
1. Hardware Configuration
Interrupts and Memory selection will be set by the host computer’s BIOS and operating
system. This section outlines jumper settings and configuration.
2. Hardware Installation
Installation involves the physical installation of the BlueStorm into your computer. Please
note that you should configure any jumper settings prior to installing the board.
3. Software/Driver Installation
Load the appropriate driver for your Operating System, as found on the accompanying
CD. Installation guides are also available on the CD to aid you in this process.
Hardware Configuration
Interrupts and Memory Address Selection
All BlueStorm products are PCI cards. Therefore, the host computer’s BIOS will automatically
set interrupts and memory addresses when you reboot after installation.
RS-422/485 Electrical Interface Configuration
Some BlueStorm adapters support RS-422/485 communication, as outlined below. (See Figure 1
through to Figure 6 for configuration jumper block locations). It may be necessary to configure
the card to match your particular wiring configuration. Please see the “Jumper Configuration for
BlueStorm” section below for configuration examples.
Full Duplex Mode
In this mode, TxD+/- and RxD+/- are being driven to a known level at all times. This mode is
typically used in point-to-point situations much like RS-232.
Half Duplex Mode
In this mode the TxD+/- line driver is enabled only when data is transmitted and RxD+/- is
disabled when data is being transmitted. This mode is typically used in either point-to-point 2-
wire connections OR in multi-drop 2-wire bus connections. This mode requires software setup
in Control Panel –System –Hardware –Device Manager –Ports –CTI PCI UART. Click on Advanced under
Port Settings after the driver is installed. (See multi-drop slave below).
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
8 Revision 0.13
Multi-drop Slave Mode
In this mode the TxD+/- line driver is enabled only when data is transmitted and RxD+/- is
enabled at all times. This mode is typically used in multi-drop 4-wire connections. This mode
requires software setup in Control Panel –System Properties –Hardware - Device Manager –Ports –CTI
PCI UART. Click on Advanced under Port Settings.
Line Bias/Termination
The RS-422/485 transceivers, both transmit and receive are optionally biased to produce a line
level mark condition through jumper selectable resistors. These options are typically used in
multi-drop 4-wire connections. Termination may also be required depending on your wiring
configuration. Each case must be evaluated to determine which options to enable.
Jumper Block Diagrams for BlueStorm
Figure 1: BlueStorm/LP Jumper Block Locations (2 Port Models)
Jx1
Jx2 Jx3 Jx4 Jx5 Jx6
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.13 9
Figure 2: BlueStorm/LP Jumper Block Locations (4 Port Models)
Figure 3: BlueStorm/LP Jumper Block Locations (8 Port Models)
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
10 Revision 0.13
Figure 4: BlueStorm/SP Jumper Block Locations (8 Port Models)
Figure 5: BlueStorm/SP Opto Jumper Block Locations (4 Port Models)
Jx1
Jx2 Jx3 Jx4 Jx5 Jx6
Jx
Female
HDB-78
JA = Port 1
JB = Port 2
JC = Port 3
JD = Port 4
JE = Port 5
JF = Port 6
JG = Port 7
JH = Port 8
Note:
Jumper blocks are not installed
for ports only capable of
communicating in
RS-232.
Jx1
Jx2 Jx3 Jx4 Jx5 Jx6
4 x RJ-45
Jx
JA = Port 1
JB = Port 2
JC = Port 3
JD = Port 4
Note:
Jumper blocks are not installed
for ports communicating in
RS-232.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.13 11
Figure 6: BlueStorm/SP RJ-11 (8 Port Model)
Note: Refer to Table 8 for port 7 and port 8 pinouts.
Jumper Configuration for BlueStorm
Jumper configuration options will vary by model. BlueStorm/LP RS-422/485 cards feature the
jumper layout listed in Figure 7, while BlueStorm/SP and BlueStorm/SP Opto cards use the
jumper layout in Figure 8. Lastly, BlueStorm/SP RJ-11 uses the jumper layout used in Figure 9.
BlueStorm ports and cards that communicate only in RS-232 modes do not have jumper blocks
installed.
Figure 7 demonstrates a common set of jumper configurations for a BlueStorm/LP RS-422/485
card. BlueStorm/LP RS-232 ports do not require jumper configuration. The four RS-422/485
ports are set as follows: Port 1 is set for half duplex, Port 2 is set for half duplex,Port 3 is set for
full duplex and Port 4 is set for multi-drop slave.
Figure 7: Jumper Configuration Example for 4 Port RS-422/485 BlueStorm/LP Models
6 x RJ-11
JA1
JA2
JA3
JA4
JA5
JA
JB1
JB2
JB3
JB4
JB5
JB
Port 1
Port 2
JC1
JC2
JC3
JC4
JC5
JC
Port 3
JD1
JD2
JD3
JD4
JD5
JD
Port 4
TxD control
RxD control
RxD Termination/Bias
RxD Termination/Bias
TxD Termination
Pin 1
Pin 1
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
12 Revision 0.13
Figure 8 indicates a common set of jumper configurations for BlueStorm/SP and BlueStorm/SP
Opto. The four ports are set as follows: Port 1 is set for RS-232, Port 2 is set for half duplex,
Port 3 is set for full duplex and Port 4 is set for multi-drop slave.
Figure 8: Jumper Configuration Example for BlueStorm/SP Opto Models
Figure 9 illustrates the jumper configurations for selecting +5V power or +12V power.
Figure 9: Jumper Configuration Examples for BlueStorm/SP RJ-11 Models
TxD Control
Install this jumper to enable the RS-485 transmitter only when sending data. This mode is useful
for multi-drop and half-duplex operation when only one device is allowed to send data at a time.
If the jumper is not installed, the transmitter will always drive the line to an idle state when not
sending data.
RxD Control
Install this jumper to enable the RS-485 receiver only when NOT transmitting data. This is
useful for two-wire half-duplex operation to prevent the transmitting device from receiving its
own data as it sends. If this jumper is not installed, the receiver is always enabled and ready to
receive data.
RxD ± Termination/Bias
Install this pair of jumpers to enable a 120 or 150 ohm terminator (model dependent) across the
RxD+ and RxD- pins for the corresponding port. A biasing network is also enabled that drives
the receiver to an inactive or safe mode. The receiver can still receive data from another device
and the biasing helps to prevent the reception of data generated by noise on the transmission
line. The two jumpers for RxD termination/bias must be installed and removed as a pair.
TxD ± Termination
Install this jumper to enable a 120 or 150 ohm resistor (model dependent) across the TxD+ and
TxD- pins of the corresponding port.
Auto 485 (BlueStorm/LP 2 port RS-422/485 models and BlueStorm/SP Opto models only)
Install this jumper to tri-state the transmitters of ports configured as RS-485 half duplex or
multi-drop slave when the computer powers up or is reset. This jumper will be overridden once
the operating system is booted by the current driver/software RS-485 mode. The jumper is used
to ensure that a port will power-on tri-stated. For example, the RS-485 mode selection in the
Windows control panel will override this jumper setting once a port is opened.
JA
JB
Port 1
Port 2
JC
Port 3
JD
Port 4
RS-485 selection
TxD control
RxD control
RxD Termination/Bias
RxD Termination/Bias
TxD Termination
JA0
JA1
JA2
JA3
JA4
JA5
JB0
JB1
JB2
JB3
JB4
JB5
JC0
JC1
JC2
JC3
JC4
JC5
JD0
JD1
JD2
JD3
JD4
JD5
J1 position = +5V power
J2 position = +12V power
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.13 13
The BlueStorm/LP RS-422/485 uses JC to configure Auto-485 mode, while the BlueStorm/SP
Opto uses J1.
Note that on BlueStorm/LP RS-422/485 models the Auto 485 is a single
jumper. The second site is not in use. See Figure 1 for the location of this
jumper. On the BlueStom/SP Opto, the first position controls the first port pair,
while the second position controls the second port pair.
Power-On Tri-state (BlueStorm/SP Models Only, Excludes
BlueStorm/SP RJ-11)
BlueStorm/SP models offer a power-on tri-state similar to the Auto-485 mode listed above. The
BlueStorm/SP will tri-state a port configured as RS-485 full duplex or RS-485 multi-drop slave.
This is meant to ensure compatibility with our legacy Blue Heat/PCI cards for customers
upgrading to the newer BlueStorm family.
Jumper J1 controls the power-on tri-state functionality. Install a jumper on the first location of
the J1 in order to tri-state Port 1 at power-on, install a jumper on the second position of J1 to
control Port 2, etc. Ports will not come out of tri-state until the driver opens the associated port
and begins transmission.
Half Duplex and Multi-drop Slave modes require you to select the appropriate
mode via software. Please refer to the readme.txt files found in the appropriate
directories on the BlueStorm/LP/SP/SP Opto CD.
Connectors and Pinouts
Table 1: DB-25 Male Pinouts for BlueStorm/LP (2 Port Connector)
Pin
No.
Port
No.
RS-232
Signal
Signal
Direction
RS-422/485
Signal
Signal
Direction
1
2
SG
signal gnd.
SR
signal ref.
2
1
TXD
output
TXD-
output
3
1
RXD
input
TXD+
output
4
1
RTS
output
RTS-
output
5
1
CTS
input
RTS+
output
6
1
DSR
input
CTS-
input
7
1
SG
signal gnd.
SR
signal ref.
8
1
DCD
input
RXD+
input
9
2
TXD
output
TXD-
output
10
2
RXD
input
TXD+
output
11
2
RTS
output
RTS-
output
12
2
CTS
input
RTS+
output
13
2
DSR
input
CTS-
input
14
NC
no connect
NC
no connect
15
NC
no connect
NC
no connect
16
NC
no connect
NC
no connect
17
NC
no connect
NC
no connect
18
NC
no connect
NC
no connect
19
2
DTR
output
RXD-
input
20
1
DTR
output
RXD-
input
21
NC
no connect
NC
no connect
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
14 Revision 0.13
22
1
RI
input
CTS+
input
23
2
RI
input
CTS+
input
24
NC
no connect
NC
no connect
25
2
DCD
input
RXD+
input
Cable CBG002 sends the signals to two DB-9 male connectors. See Table 6 for pinout details.
NOTE: This is not the pinout of DB-25 cable CBG007.
Table 2: HDB-44 Pinouts for BlueStorm/LP (4 Port Connector)
Pin
No.
Port
No.
RS-232
Signal
Signal
Direction
RS-422/485
Signal
Signal
Direction
1
1
TXD
output
TXD-
output
2
1
RTS
output
RTS-
output
3
1
DCD
input
RXD+
input
4
1
RXD
input
TXD+
output
5
2
TXD
output
TXD-
output
6
2
RTS
output
RTS-
output
7
2
DCD
input
RXD+
input
8
2
RXD
input
TXD+
output
9
3
TXD
output
TXD-
output
10
3
RTS
output
RTS-
output
11
3
DCD
input
RXD+
input
12
3
RXD
input
TXD+
output
13
4
TXD
output
TXD-
output
14
4
RTS
output
RTS-
output
15
4
DCD
input
RXD+
input
16
1
CTS
input
RTS+
output
17
1
SG
signal gnd.
SR
signal ref.
18
NC
no connect
NC
no connect
19
NC
no connect
NC
no connect
20
2
CTS
input
RTS+
output
21
2
SG
signal gnd.
SR
signal ref.
22
NC
no connect
NC
no connect
23
3
CTS
input
RTS+
output
24
3
SG
signal gnd.
SR
signal ref.
25
NC
no connect
NC
no connect
26
NC
no connect
NC
no connect
27
4
CTS
input
RTS+
output
28
4
SG
signal gnd.
SR
signal ref.
29
NC
no connect
NC
no connect
30
4
RXD
input
TXD+
output
31
1
DSR
input
CTS-
input
32
1
DTR
output
RXD-
input
33
1
RI
input
CTS+
input
34
NC
no connect
NC
no connect
35
2
DSR
input
CTS-
input
36
2
DTR
output
RXD-
input
37
2
RI
input
CTS+
input
38
NC
no connect
NC
no connect
39
3
DSR
input
CTS-
input
40
3
DTR
output
RXD-
input
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.13 15
41
3
RI
input
CTS+
input
42
4
DSR
input
CTS-
input
43
4
DTR
output
RXD-
input
44
4
RI
input
CTS+
input
Cable CBG003 sends the signals to four DB-9 male connectors. Cable CBG007 sends the
signals to four DB-25 connectors. See Table 6 for pinout details.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
16 Revision 0.13
Table 3: VHDCI-68 Female Pinouts for BlueStorm/LP (8 Port Connector)
Pin
No.
Port
No.
RS-232
Signal
Signal
Direction
RS-422/485
Signal
Signal
Direction
1
1
TXD
output
TXD-
output
2
1
RI
input
CTS+
input
3
1
DCD
input
RXD+
input
4
1
DTR
output
RXD-
input
5
1
RTS
output
RTS-
output
6
1
DSR
input
CTS-
input
7
1
RXD
input
TXD+
output
8
1
CTS
input
RTS+
output
9
2
TXD
output
TXD-
output
10
2
RI
input
CTS+
input
11
2
DCD
input
RXD+
input
12
2
DTR
output
RXD-
input
13
2
RTS
output
RTS-
output
14
2
DSR
input
CTS-
input
15
2
RXD
input
TXD+
output
16
2
CTS
input
RTS+
output
17
1, 2
SG
signal gnd.
SR
signal ref.
18
3, 4
SG
signal gnd.
SR
signal ref.
19
3
TXD
output
TXD-
output
20
3
RI
input
CTS+
input
21
3
DCD
input
RXD+
input
22
3
DTR
output
RXD-
input
23
3
RTS
output
RTS-
output
24
3
DSR
input
CTS-
input
25
3
RXD
input
TXD+
output
26
3
CTS
input
RTS+
output
27
4
TXD
output
TXD-
output
28
4
RI
input
CTS+
input
29
4
DCD
input
RXD+
input
30
4
DTR
output
RXD-
input
31
4
RTS
output
RTS-
output
32
4
DSR
input
CTS-
input
33
4
RXD
input
TXD+
output
34
4
CTS
input
RTS+
output
35
5
TXD
output
TXD-
output
36
5
RI
input
CTS+
input
37
5
DCD
input
RXD+
input
38
5
DTR
output
RXD-
input
39
5
RTS
output
RTS-
output
40
5
DSR
input
CTS-
input
41
5
RXD
input
TXD+
output
42
5
CTS
input
RTS+
output
43
6
TXD
output
TXD-
output
44
6
RI
input
CTS+
input
45
6
DCD
input
RXD+
input
46
6
DTR
output
RXD-
input
...Continued on next page
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.13 17
Table 3: VHDCI-68 Female Pinouts for BlueStorm/LP (Continued)
Pin
No.
Port
No.
RS-232
Signal
Signal
Direction
RS-422/485
Signal
Signal
Direction
47
6
RTS
output
RTS-
output
48
6
DSR
input
CTS-
input
49
6
RXD
input
TXD+
output
50
6
CTS
input
RTS+
output
51
5, 6
SG
signal gnd.
SR
signal ref.
52
7, 8
SG
signal gnd.
SR
signal ref.
53
7
TXD
output
TXD-
output
54
7
RI
input
CTS+
input
55
7
DCD
input
RXD+
input
56
7
DTR
output
RXD-
input
57
7
RTS
output
RTS-
output
58
7
DSR
input
CTS-
input
59
7
RXD
input
TXD+
output
60
7
CTS
input
RTS+
output
61
8
TXD
output
TXD-
output
62
8
RI
input
CTS+
input
63
8
DCD
input
RXD+
input
64
8
DTR
output
RXD-
input
65
8
RTS
output
RTS-
output
66
8
DSR
input
CTS-
input
67
8
RXD
input
TXD+
output
68
8
CTS
input
RTS+
output
Cable CBG009 and/or IOBG08BLV1will send the signals to eight DB-9 male connectors. See
Table 6 for the DB-9 pinouts. Cable CBG026 will send the signals to eight DB-25 male
connectors. See Table 6 for the DB-25 pinout details.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
18 Revision 0.13
Table 4: HDB-78 Pinouts for BlueStorm/SP (8 Port Connector)
Pin
No.
Port
No.
RS-
232
Signal
Signal
Direction
RS-422/48
5
Signal
Signal
Direction
1
5
RTS
output
RTS A(-)
output
2
5
CTS
input
RTS B(+)
output
3
5
DSR
input
CTS A(-)
input
4
5
RI
input
CTS B(+)
input
5
5
SG
signal gnd.
SR
signal ref.
6
6
RTS
output
RTS A(-)
output
7
6
CTS
input
RTS B(+)
output
8
6
DSR
input
CTS A(-)
input
9
6
RI
input
CTS B(+)
input
10
7
RTS
output
RTS A(-)
output
11
7
CTS
input
RTS B(+)
output
12
7
DSR
input
CTS A(-)
input
13
7
RI
input
CTS B(+)
input
14
7
SG
signal gnd.
SR
signal ref.
15
8
RTS
output
RTS A(-)
output
16
8
CTS
input
RTS B(+)
output
17
8
DSR
input
CTS A(-)
input
18
8
RI
input
CTS B(+)
input
19
NC
no connect
NC
no connect
20
NC
no connect
NC
no connect
21
5
TxD
output
TxD A(-)
output
22
5
RxD
input
TxD B(+)
output
23
5
DTR
output
RxD A(-)
input
24
5
DCD
input
RxD B(+)
input
25
6
SG
signal gnd.
SR
signal ref.
26
6
TxD
output
TxD A(-)
output
27
6
RxD
input
TxD B(+)
output
28
6
DTR
output
RxD A(-)
input
29
6
DCD
input
RxD B(+)
input
30
7
TxD
output
TxD A(-)
output
31
7
RxD
input
TxD B(+)
output
32
7
DTR
output
RxD A(-)
input
33
7
DCD
input
RxD B(+)
input
34
SG
signal gnd.
NC
no connect
35
8
TxD
output
TxD A(-)
output
36
8
RxD
input
TxD B(+)
output
37
8
DTR
output
RxD A(-)
input
38
8
DCD
input
RxD B(+)
input
39
8
SG
signal gnd.
SR
signal ref.
…Continued on next page
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.13 19
Table 4: HDB-78 Pinouts for BlueStorm/SP (Continued)
Pin
No.
Port
No.
RS-
232
Signal
Signal
Direction
RS-422/48
5
Signal
Signal
Direction
40
1
RTS
output
RTS A(-)
output
41
1
CTS
input
RTS B(+)
output
42
1
DSR
input
CTS A(-)
input
43
1
RI
input
CTS B(+)
input
44
1
SG
signal gnd.
SR
signal ref.
45
2
RTS
output
RTS A(-)
output
46
2
CTS
input
RTS B(+)
output
47
2
DSR
input
CTS A(-)
input
48
2
RI
input
CTS B(+)
input
49
3
RTS
output
RTS A(-)
output
50
3
CTS
input
RTS B(+)
output
51
3
DSR
input
CTS A(-)
input
52
3
RI
input
CTS B(+)
input
53
3
SG
signal gnd.
SR
signal ref.
54
4
RTS
output
RTS A(-)
output
55
4
CTS
input
RTS B(+)
output
56
4
DSR
input
CTS A(-)
input
57
4
RI
input
CTS B(+)
input
58
NC
no connect
NC
no connect
59
NC
no connect
NC
no connect
60
1
TxD
output
TxD A(-)
output
61
1
RxD
input
TxD B(+)
output
62
1
DTR
output
RxD A(-)
input
63
1
DCD
input
RxD B(+)
input
64
2
SG
signal gnd.
SR
signal ref.
65
2
TxD
output
TxD A(-)
output
66
2
RxD
input
TxD B(+)
output
67
2
DTR
output
RxD A(-)
input
68
2
DCD
input
RxD B(+)
input
69
3
TxD
output
TxD A(-)
output
70
3
RxD
input
TxD B(+)
output
71
3
DTR
output
RxD A(-)
input
72
3
DCD
input
RxD B(+)
input
73
4
SG
signal gnd.
SR
signal ref.
74
4
TxD
output
TxD A(-)
output
75
4
RxD
input
TxD B(+)
output
76
4
DTR
output
RxD A(-)
input
77
4
DCD
input
RxD B(+)
input
78
NC
no connect
NC
no connect
Cable CAG08FXDX and/or the IOBG08DB9V1 will send the signals to eight DB-9 male
connectors. See Table 6 for the DB-9 pinouts. Cable CAG08DB25 will send the signals to eight
DB-25 connectors. See Table 6 for the DB-25 pinouts.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

BlueStorm Installation Guide, Connect Tech Inc.
20 Revision 0.13
Table 5: RJ-45 Pinouts for BlueStorm/SP Opto (4 Port Connector)
Pin No.
RS-232
Signal
Direction
RS-422/485
Signal
Direction
1
N/C
no connect
RTS (-)
output
2
N/C
input
RxD (+)
input
3
RTS
output
RTS (+)
output
4
SG
signal gnd
SR
signal ref.
5
TxD
output
TxD (+)
output
6
RxD
input
RxD (-)
input
7
Gnd
ground
Gnd.
ground
8
CTS
input
CTS (+)
input
9
N/C
no connect
TxD (-)
output
10
N/C
no connect
CTS (-)
input
RJ-45 connector
1 10
Cable CAGRJ4509 will send the signals to eight DB-9 male connectors. See Table 7 for the DB-9
pinouts
Table 6: Pinouts and Control Signals for RJ-45 Connectors (BlueStorm/LP RJ-45 Only)
Port 4 when a DB-9 cable (part
number CAG104K) is attached
Ports 1 through 3, which are accessible
through the factory installed bracket
DB-9
Pin No.
RS-232
Signal
Direction
RJ-45
Pin No.
RS-232
Signal
Direction
1
DCD
input
1
TxD
Output
2
RxD
input
2
DTR
Output
3
TxD
output
3
RTS
Output
4
DTR
output
4
N/C
No Connect
5
SG
signal ground
5
RxD
Input
6
DSR
input
6
DSR
Input
7
RTS
output
7
CTS
Input
8
CTS
input
8
SG
Signal ground
9
RI
input
Part #:CAG104K
Technical Tip:
Please ensure that you terminate the CTS signal if your application does
not use them. The common way to do this is to connect CTS to RTS.
Failure to do so may result in loss of a performance on your
BlueStorm/LP RJ-45 adapter.
Male DB-9 Connector
1
5
6
9
1
8
RJ-45 Connector
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.
Other manuals for BLUESTORM UNIVERSAL PCI
1
Table of contents
Other Connect Tech PCI Card manuals
Popular PCI Card manuals by other brands

Quanta Computer
Quanta Computer BCM94306MP user manual

Avermedia
Avermedia BRAVO HYBRID H788 brochure

Pegatron
Pegatron WL-227N_ABAND Hardware and Driver Reference

B&B Electronics
B&B Electronics 3PCIOSD1A manual

ZyXEL Communications
ZyXEL Communications AG-320 Declaration of conformity

Exsys
Exsys EX-44010 quick start guide

Adaptec
Adaptec HotConnect 8920 Specification sheet

SIIG
SIIG CyberSerial Dual PCIe Quick installation guide

Acces I/O products
Acces I/O products MPCIE-AIO16-16F Series Hardware manual

Encore
Encore ENL-WI-G user guide

National Instruments
National Instruments NI 6608 user manual

Sonnet
Sonnet TEMPO ATA133 quick start guide