When the appliance is installed at elevations above 4,500ft (1371m), and in the absence of specific recommendations
from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for
each additional 1,000ft (305m).
Change in flame appearance from "HI" to "LO" is more evident in natural gas than in propane.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certified kit is used.
CDVS600 - This appliance is not approved for closet or recessed installations. It is approved for bathroom,
bedroom and bedsitting room installations. This appliance may be installed in an aftermarket permanently lo-
cated, manufactured (mobile) home, where not prohibited by local codes. (Rear vent) This application requires
changing the main burner orifice, for horizontal exits off the rear only.
CS600 -This appliance is approved for bedroom and bed-sitting room installations.
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the
model, venting and gas type of the unit.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
2.4 RATING PLATE INFORMATION
.
GDS60
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
W385-0459 / D
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: ANSI Z21.50b-2009, CSA2.22b-2009
VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
MODEL NATURAL GAS/GAZ NATURAL MODEL PROPANE/PROPANE MODÈLE
DIRECT VENT B-VENT B-VENT DIRECT VENT
GDS60N GS60N GS60P GDS60P
CDVS600N CS600N CS600P CDVS600P
TOP VENT REAR VENT TOP VENT REAR VENT
0-4500 0-4500 0-4500 ALTITUDE(FT/PT)ELEVATION 0-4500 0-4500 0-4500
35,000 *21,000 35,000 INPUT(BTU/H)ALIMENTATION 31,500 31,500 *21,000
21,000 12,000 21,000 REDUCED INPUT(BTU/H)ALIMENTATION REDUITE 22,000 22,000 *13,000
24,500 *14,700 OUTPUT(BTU/H)RENDEMENT 22,050 *14,700
63.1% P4 63.1%
*WHEN VENTING OFF THE REAR OF THE UNITANDTERMINATING HORIZONTALLY
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C. (LP)
PRESSION AU COLLECTEUR: 3.5” (GN) / 10” (PG) D’UNE COLONNE DEAU
MIN SUPPLY PRESSURE: 4.5” W.C. (NG) / 11” (LP)
PRESSION D’ALIMENTATION MIN: 4.5” (GN) / 11” (PG) D’UNE COLONNE
D’EAU
MAX. SUPPLY PRESSURE: 7” W.C. (NG) / 13” W.C. (LP)
PRESSION D’ALIMENTATION MAX: 7” (GN) / 13” (PG) D’UNE COLONNE D’EAU
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENTAVEC
CETTE UNITE.
WARNING: DO NOTADD ANY MATERIAL TO THEAPPLIANCE, WHICH WILL
COME IN CONTACT WITH THE FLAMES, OTHER THANTHATSUPPLIED BY
THE MANUFACTURER WITHTHE APPLIANCE.
DECORATIVE PRODUCT: NOT FOR USEAS AHEATINGAPPLIANCE
OPTIONALBLOWER KIT / ENSEMBLE DE
VENTILATEUR FACULTATIF: GS64-KT
AVERTISSEMENT: N’AJOUTEZ PASA CETAPPAREILAUCUN
MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE
QUE CELUI QUI EST FOURNIAVEC CETAPPAREIL PAR LE FABRICANT.
PRODUIT DÉCORATIF: NE PAS UTI;ISER COMME APPARIEL DE
CHAUFFAGE
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL / DEGAGEMENTS
MINIMAUX DES MATERIAUX COMBUSTIBLES:
A 6”
B 6”
C 2”
20” TO CEILING FROM STOVETOP
1” TO DIRECT VENTAND B-VENT / L’EVACUATION DIRECTE &
L’EVACUATION B
6” TO C-VENT/ AL’EVACUATION C
20” ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING/CLASS: 115V 1.5AMP 60HZ
MODEL CS600/GS60
APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION. HOMOLOGUE POUR
INSTALLATION DANS UNE CHAMBRE ACOUCHER, & UN STUDIO. THISAPPLIANCE MUST
BE INSTALLED USING ANADAPTER KIT GS-150KT. CET APPAREIL DOIT ETRE INSTALLE
EN UTILISANT UN ENSEMBLEADAPTATEUR GS-150KT.
MODEL CDVS600/GDS60
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITHTHE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADAOR IN
THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE
USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES,ANSI/NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE ACOUCHER, UNE SALLE DE
BAIN ET UN STUDIO.APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
INSTALLATION CONFORME AUX EXIGENCES DE LANORME CAN/CSAZ240MH SERIE DE
MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEURAU CANADAOU AUX ETATS-UNIS DE
LA NORME DE SECURITE ETDE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE
24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D’ETATS-UNIS NE PEUT ETRE
APPLIQUEE, SE REFERER ALANORME RELATIVEAU CRITERE DE MESURES DE
SECURITE CONTRE L’INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
MANUFACTURES, LES SITES ETLES COMMUNAUTES, ANSI/NFPA 501A.
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHSARE 25 INCHES AND 20 FEET
RESPECTIVELY FOR TOPVENTED UNITS AND 13 INCHESAND 20 FEET RESPECTIVELY
FOR REAR VENTED UNITS.
LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS
RESPECTIVEMENT POUR UN EVACUATION VERTICALE ET 13 POUCES ET20 PIEDS
RESPECTIVEMENT POUR UN EVACUATION HORIZONTALE.
THE APPLIANCE MUSTBE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE
OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS.
PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
VENT-AIR INTAKE SYSTEM.
L’APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L’ENSEMBLE D’EVACUATION PROPRE
A NAPOLEON. REFERERAU MANUEL D’INSTALLATION DE PROPRIETAIRE POUR
L’EVACUATION PRECISE. ILEST IMPORTANT DE BIEN REINSTALLER ET RESCELLER
L’EVENTAPRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D’AIR.
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT
PAS ETRE UTILISE AVEC CET APPAREIL
SERIAL NUMBER
NO. DE SERIE
9700539 (WSL)
4001658 (NAC) 4001659 (WUSA)
4001657 (NGZ)
EVANT ENTRER EN CONTACT AVEC L
E CELUI QUI EST FOURNIAVEC CETAPPAR
MINIMUM CLEARANCE TO COMBUST
MINIMAUX DES MATERIAUX CO