Continuum Echo User manual

Echo Pedicure Chair
USER MANUAL
1-400-0084 • Rev A • 2/5/20
© Continuum 2020, All Rights Reserved
*shown with oponal accessories and/or nishes

© Copyright 2020
Continuum®
All rights reserved. is document or
any portion thereof may not be repro-
duced in any way, including photocopy-
ing or translation to another language
without the prior written permission
from Continuum.
Continuum® is a registered trademark of
Earthlite, LLC,
Legal Notice
e information provided in this document is intended
for informational purposes only and is subject to change
without notice. e information provided in this docu-
ment should not be construed as a commitment by
Continuum®.
Continuum® assumes no responsibility for the accuracy
or suitability of the information contained in this docu-
ment. is document may contain technical inaccura-
cies or errors. Continuum® makes no expressed or im-
plied warranties of any kind concerning the information
contained in this document, including, but not limited
to, the implied warranties of merchantability and tness
for purpose.
Continuum® shall not be liable for incidental or conse-
quential damages in connection with or arising out of
the product, performance, or use of this document and
the information and material it describes.

Introduction
Secon 1: Safety Informaon
Secon 2: Product Overview
Secon 3: Operang Instrucons
Secon 4: Care & Maintenance
Secon 5: Installaon
4
7
7
8
8
14
Table of Contents

READ AND SAVE THESE INSTRUCTIONS
2
IMPORTANT SAFETY INSTRUCTIONS - FOR COMMERCIAL USE ONLY
Read all instructions before using this product.
Safety Symbols
Familiarize yourself with the following
Safety & Warning symbols. They are
designed to prevent damage and
injury to you, your clients, and your new
Continuum product.
IMPORTANT: The important safety
instructions and warnings in this manual
cannot cover all possible problems and
conditions that can occur. Use common
sense and caution when installing,
operating, or maintaining this appliance.
Indicates an imminently hazardous
situation which could result in serious
or fatal injury.
Indicates a potentially hazardous
situation which could result in serious
injury.
Indicates a potentially hazardous
situation which could result in
equipment damage and/or injury.
SECTION 1: SAFETY INFORMATION
RISK OF ACCIDENTAL INJURY OR DROWNING. DO NOT USE
DRUGS OR ALCOHOL BEFORE OR DURING USE. CHILDREN
OR HANDICAPPED PERSONS SHOULD NOT USE WITHOUT
SUPERVISION.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
the body temperature of 98.6°F or 37°C. The symptoms of hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat,
b) Failure to recognize the need to exit the hydromassage bathtub,
c) Unawareness of impending hazard,
d) Fetal damage in pregnant women,
e) Physical inability to exit the hydromassage bathtub, and
f) Unconsciousness resulting in the danger of drowning. WARNING - The use of alcohol, drugs, or
medication can greatly increase the risk of fatal hyperthermia.
WARNING - RISK OF ELECTRIC SHOCK - Do not permit electric appliances (such as hair dryers,
lamp, telephone, radio, or television) to be within 5 ft (1.5m) of this unit.
WARNING - RISK OF INJURY - Exercise care when using a foot bath. Use this product for its
intended purpose: a manicure chair and ll and drain indoor commercial appliance for foot and ankle hydro
massage. DO NOT use attachments not recommended by manufacturer.
WARNING - MOVABLE PARTS, RISK OF INJURY:
• Keep children away from adjustable seat armrests, tilt back, and seat slide, and footrest.
WARNING - To reduce the risk of burns, re, electric shock, or injury to persons:
• Unplug from outlet before putting on or taking off parts.
• Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled
persons. DO NOT leave children alone or allow them to operate the controls. Keep controls out of
reach of children. DO NOT allow children to crawl behind the chair.
• Never use this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. Return the furnishing to a service center for examination
and repair.
• Keep the cord away from heated surfaces.
• Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair, etc.
• Never drop or insert any object into any opening.
WARNING - RISK OF HYPERTHERMIA AND POSSIBLE DROWNING. WATER
TEMPERATURE IN EXCESS OF 38°C or 100.4°F CAN BE INJURIOUS TO YOUR HEALTH.
CHECK AND ADJUST WATER TEMPERATURE BEFORE USE.

READ AND SAVE THESE INSTRUCTIONS 3
SECTION 1: SAFETY INFORMATION
• DO NOT reach for any electrical object that has fallen into the water. Unplug immediately.
• DO NOT drop or insert anything into jet opening.
• DO NOT operate without the complete jet assembly installed or without water lled 1 inch above jets.
• DO NOT overll the basin.
• DO NOT stand on or in the basin, or on the foot rest.
• DO NOT leave this appliance unattended when in operation.
• DO NOT use outdoors.
• Keep the electrical cord away from heated surfaces.
• Connect this appliance only to a properly grounded outlet.
• To avoid injury, exercise care when entering or exiting the chair and foot bath.
• Use caution when making positioning adjustments to your chair. Keep all equipment and body parts
away from moving parts while making any adjustments.
• It is important that you clean and disinfect the jets and basin after every use.
• Hydrotherapy should be pleasant and comfortable. Should you or a client experience any pain or
discomfort while using the foot bath, discontinue use immediately and consult a physician.
• You or your clients should consult a physician if diabetic, have poor circulation, if feet or legs are in-
amed, have an open wound, or if you have questions about whether you should be using hydro mas-
sage equipment.
• A licensed plumber and electrician are strongly recommended to install your foot bath.
• Make certain that the cord and plug are maintained in good condition and are not allowed to become
damaged while in use. Avoid positioning the cord in the trafc lane and it is always kept out of the way.
Take this furnishing out of service immediately if the cord or plug becomes damaged in any way.
• Do not attempt to repair. All repairs must be performed by an authorized service representative.
1. RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground-fault
circuit-interrupter (GFCI).
2. Grounding is required. The unit must be installed by a licensed electrician and
grounded.
This product must be grounded. If it should malfunction or break down, grounding provides a path of
least resistance for electric current to reduce the risk of electric shock. This product is equipped with
a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
Improper connection of the equipment-grounding connector can result in a risk of electric shock. Check
with a qualied electrician or serviceman if you are in doubt as to whether the product is properly grounded.
Do not modify the plug provided with the product - if it will not t the outlet, have a proper outlet installed by
a qualied electrician.
INSTALLATION INSTRUCTIONS / GROUNDING INSTRUCTIONS
Reset
Button
GFCI Outlet
Grounding Pin
Test
Button

SECTION 2: PRODUCT OVERVIEW
4
Fold Down
Manicure Trays
with Cupholder
Water Fill
Valve
*Chair shown with oponal nishes
Sprayer/Fill
Contoured Footrest
Client Controls
Drain Pump
Button
Echo LE
Echo SE
Drain
Release
Technician
Controls
Contoured Footrest
Water Fill
Valve
Sprayer/Fill
Drain Pump
Button
Drain
Release
Client Controls
(1 of 2)

*Measurements may vary due to natural material variaons.
5
Feature Echo LE Echo SE Oponal
Reclining back X X
Pipeless magnec jet system X X
Fiberglass basin with
textured boom X X
Solid surface basin X
Gravity drain pump X X
Discharge pump X
Full concealment side panels X
Dual vented air system X
Full shiatsu back massage X
Relaxor Heat & Massage X
Dual client/tech seat controls X
USB Port X
Cupholder
Upholstery
Included Features
Product Specications
Echo LE Echo SE
Length
Width
Overall Height
Seat Height
SECTION 2: PRODUCT OVERVIEW
Echo LE
Echo SE

SECTION 3: OPERATING INSTRUCTIONS
Assembly Instructions
NOTE:
Figure 1
Important Notes:
6
Connec ng Pin
Latch
Release Lever
Figure 2

SECTION 3: OPERATING INSTRUCTIONS
7
Leveling Your Chair
Filling the Tub
Turn Right
for Cold
Turn Le
for Hot
Turn to close
pop-up drain

8
SECTION 3: OPERATING INSTRUCTIONS
Jet System
NOTE:
Center Support
Gravity Drain & Drain Pump (Optional)
Gravity Drain
Drain Pump
Drain Pump
On/O Buon
Drain Handle
Correctly
placed
impeller
Jet
Cover
Jet housing

SECTION 3: OPERATING INSTRUCTIONS
9
Adjustable Center Leg Support with Adjacent Foot Rests
IMPORTANT:
Center Support
Electrical Specications
Spec North America Europe/Asia
Tighten knob to keep
center support raised
Technician Controls
Decrease seat back lt
Slide seat backwards
Increase seat back lt
Slide seat forwards

SECTION 3: OPERATING INSTRUCTIONS
10
LE Hand Control
RISK OF ELECTRIC SHOCK
Master Power On/O
Decrease Back Tilt
Slide Seat Back
Slide Seat Forward
Increase Back Tilt
Tapping Massage (lights
indicate intensity level)
Massage Timer
Adjust Massage Range
(Full, Spot, Paral)
Massage Wheel
Raise/Lower
Adjust Tapping
Massage Width
Kneading Massage
(lights indicate intensity)
Combinaon Massage
(lights indicate intensity)
Knocking Massage
(lights indicate intensity)

11
SE Hand Controls
SECTION 3: OPERATING INSTRUCTIONS
Power
High Heat
Low Heat
Massage All Zones - Connuous
Massage All Zones - Sequenal
Massage All Zones - Short Bursts
Zone 1
Massage
Zone 2
Massage
Lower
Intensity
Raise
Intensity
Raise
Speed
Lower
Speed
Increase
Back Tilt
Decrease
Back Tilt
Slide Seat
Back
Slide Seat
Forward
RISK OF ELECTRIC SHOCK
Decrease Back Tilt
Slide Seat Back
Tapping Massage (lights
indicate intensity level)
Massage Timer
Adjust Massage Range
(Full, Spot, Paral)
Adjust Tapping
Massage Width

SECTION 4: CARE & MAINTENANCE
YOU ARE REQUIRED TO CHECK WITH YOUR STATE BOARD FOR MANDATORY CLEANING AND
DISINFECTING REQUIREMENTS AND PROCEDURES.
Cleaning & Ongoing Maintenance
Category Care/Maintenance Recommendation
12

Category Care Recommendation
13
SECTION 4: CARE & MAINTENANCE

SECTION 4: CARE & MAINTENANCE
Tub Cleaning Guide
Recommended Cleaning and Disinfecting Products
14
Cleaning After Each Client & End of Day
NOTE: THE ABOVE SHOULD BE FOLLOWED EVEN IF TUB LINERS ARE USED
Cleaning Every Other Week

15
SECTION 4: CARE & MAINTENANCE
(877) 255-3030(760) 597-5707
Troubleshooting
Issue Solution

16
SECTION 4: CARE & MAINTENANCE
Excluded from Limited Warranty:
Parts and/or circumstances for which labor is NOT COVERED - Parts noted below are
simple to replace and DO NOT require a service technician:
Warranty Information

SECTION 5: INSTALLATION
17
IMPORTANT: All pedicure chairs MUST be installed by a licensed electrician and a licensed plumber in
accordance with all naonal, state, and local codes/regulaons.
Install to Permit Access for Servicing
• EXTREMELY IMPORTANT:
Your
warranty is null and void if pedicure chair is not properly secured to nished oor.
• Note: IF INSTALLED IN CANADA THIS UNIT MUST BE IN ACCORDANCE WITH THE
CANADIAN ELECTRICAL CODE, PART 1.
• Locaon & Support:
• DEPENDING ON THE USE OF MANICURE TRAYS AND/OR CARTS, THE EXACT DISTANCE
BETWEEN PEDICURE CHAIRS WILL VARY GREATLY. THIS MUST BE DISCUSSED PRIOR
TO ORDERING PEDICURE CHAIRS. THIS WILL ENSURE PROPER INSTALLATION AND
ADEQUATE WORKING SPACE.
Electrical Requirements:
Hot/Cold Water Supply & Drain:
C)
C)
• INSTALLATION OF OPTIONAL DRAIN PUMP MUST BE NOTED ON ORIGINAL CUSTOMER
ORDER. DRAIN PUMP MUST BE FACTORY INSTALLED.
Installation Instructions

Leveling/Mounng Instrucons
Step 1:
Step 2:
ADDITIONAL INFORMATION REGARDING GRAVITY DRAIN INSTALLATIONS
• Full Concealment side panels are Strongly Recommended
SECTION 5: INSTALLATION
18
Table of contents
Other Continuum Pedicure Spa manuals