Continuum Maestro Opus User manual

Maestro Opus Pedicure Chair
USER MANUAL
1-400-0088 • Rev A • 2/5/2020
© Continuum 2020, All Rights Reserved
*shown with oponal accessories and/or nishes

© Copyright 2020
Continuum®
All rights reserved. is document or
any portion thereof may not be repro-
duced in any way, including photocopy-
ing or translation to another language
without the prior written permission
from Continuum.
Continuum® is a registered trademark of
Earthlite, LLC,
Legal Notice
e information provided in this document is intended
for informational purposes only and is subject to change
without notice. e information provided in this docu-
ment should not be construed as a commitment by
Continuum®.
Continuum® assumes no responsibility for the accuracy
or suitability of the information contained in this docu-
ment. is document may contain technical inaccura-
cies or errors. Continuum® makes no expressed or im-
plied warranties of any kind concerning the information
contained in this document, including, but not limited
to, the implied warranties of merchantability and tness
for purpose.
Continuum® shall not be liable for incidental or conse-
quential damages in connection with or arising out of
the product, performance, or use of this document and
the information and material it describes.

Introduction
Congratulaons on your purchase of the Maestro Opus pedicure chair. The Maestro Opus has
a disncve design and bold lines set the standard for high-end, luxury pedicure chairs. The
Maestro Opus is packed with features that are sure to sasfy the most discerning clients, such
as dual seat controls, hand cut and sewn upholstery, solid surface basin, and Relaxor heat and
massage system.
The Maestro Opus is designed for licensed therapists and technicians and is intended to be used in
a professional spa, salon, or similar commercial environment. While no special training is needed
to operate the product, for safety reasons it is important that the instrucons contained in this
manual are reviewed in detail before the rst use. This manual should be read in its enrety by
each professional who will be operang the product to ensure the safety of both operator and
client. This manual should be saved for future reference.
The Maestro Opus should not be used in any other manner than described in this manual.
Please read, understand, and follow all safety warnings, labels, and instrucons. Misuse, use of
unnecessary force, or using the chair for unintended or unauthorized procedures can result in
injury to operator, client, and/or equipment.
Detailed instrucons for use and maintenance can be found in this user manual. If you have
further quesons, please contact us at (877) 255-3030 for US customers, or (760) 597-5707 for
internaonal customers. We can also be reached via e-mail at orders@connuumpedicure.com.
Secon 1: Safety Informaon
Safety Symbols/Warnings
Secon 2: Product Overview
Product Diagram
Product Specicaons
Secon 3: Operang Instrucons
Leveling Your Chair
Filling the Tub
Gravity Drain & Drain Pump
Jet System
Technician Controls
Chair Swivel
Electrical Specicaons
Client Controls
Secon 4: Care & Maintenance
Cleaning & Ongoing Maintenance
Tub Cleaning Guide
Troubleshoong
Warranty Informaon
Contact Us
2-3
4
5
6
6
7
7
8
8
8
9
10
11
12
13
back cover
Table of Contents

READ AND SAVE THESE INSTRUCTIONS
2
IMPORTANT SAFETY INSTRUCTIONS - FOR COMMERCIAL USE ONLY
Read all instructions before using this product.
Safety Symbols
Familiarize yourself with the following
Safety & Warning symbols. They are
designed to prevent damage and
injury to you, your clients, and your new
Continuum product.
IMPORTANT: The important safety
instructions and warnings in this manual
cannot cover all possible problems and
conditions that can occur. Use common
sense and caution when installing,
operating, or maintaining this appliance.
Indicates an imminently hazardous
situation which could result in serious
or fatal injury.
Indicates a potentially hazardous
situation which could result in serious
injury.
Indicates a potentially hazardous
situation which could result in
equipment damage and/or injury.
SECTION 1: SAFETY INFORMATION
RISK OF ACCIDENTAL INJURY OR DROWNING. DO NOT USE
DRUGS OR ALCOHOL BEFORE OR DURING USE. CHILDREN
OR HANDICAPPED PERSONS SHOULD NOT USE WITHOUT
SUPERVISION.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
the body temperature of 98.6°F or 37°C. The symptoms of hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat,
b) Failure to recognize the need to exit the hydromassage bathtub,
c) Unawareness of impending hazard,
d) Fetal damage in pregnant women,
e) Physical inability to exit the hydromassage bathtub, and
f) Unconsciousness resulting in the danger of drowning. WARNING - The use of alcohol, drugs, or
medication can greatly increase the risk of fatal hyperthermia.
WARNING - RISK OF ELECTRIC SHOCK - Do not permit electric appliances (such as hair dryers,
lamp, telephone, radio, or television) to be within 5 ft (1.5m) of this unit.
WARNING - RISK OF INJURY - Exercise care when using a foot bath. Use this product for its
intended purpose: a manicure chair and ll and drain indoor commercial appliance for foot and ankle hydro
massage. DO NOT use attachments not recommended by manufacturer.
WARNING - MOVABLE PARTS, RISK OF INJURY:
• Keep children away from adjustable seat armrests, tilt back, and seat slide, and footrest.
WARNING - To reduce the risk of burns, re, electric shock, or injury to persons:
• Unplug from outlet before putting on or taking off parts.
• Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled
persons. DO NOT leave children alone or allow them to operate the controls. Keep controls out of
reach of children. DO NOT allow children to crawl behind the chair.
• Never use this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. Return the furnishing to a service center for examination
and repair.
• Keep the cord away from heated surfaces.
• Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair, etc.
• Never drop or insert any object into any opening.
WARNING - RISK OF HYPERTHERMIA AND POSSIBLE DROWNING. WATER
TEMPERATURE IN EXCESS OF 38°C or 100.4°F CAN BE INJURIOUS TO YOUR HEALTH.
CHECK AND ADJUST WATER TEMPERATURE BEFORE USE.

READ AND SAVE THESE INSTRUCTIONS 3
SECTION 1: SAFETY INFORMATION
• DO NOT reach for any electrical object that has fallen into the water. Unplug immediately.
• DO NOT drop or insert anything into jet opening.
• DO NOT operate without the complete jet assembly installed or without water lled 1 inch above jets.
• DO NOT overll the basin.
• DO NOT stand on or in the basin, or on the foot rest.
• DO NOT leave this appliance unattended when in operation.
• DO NOT use outdoors.
• DO NOT swivel when chair is in tilt position.
• Keep the electrical cord away from heated surfaces.
• Connect this appliance only to a properly grounded outlet.
• To avoid injury, exercise care when entering or exiting the chair and foot bath.
• Use caution when making positioning adjustments to your chair. Keep all equipment and body parts
away from moving parts while making any adjustments.
• It is important that you clean and disinfect the jets and basin after every use.
• Hydrotherapy should be pleasant and comfortable. Should you or a client experience any pain or
discomfort while using the foot bath, discontinue use immediately and consult a physician.
• You or your clients should consult a physician if diabetic, have poor circulation, if feet or legs are in-
amed, have an open wound, or if you have questions about whether you should be using hydro mas-
sage equipment.
• A licensed plumber and electrician are strongly recommended to install your foot bath.
• Make certain that the cord and plug are maintained in good condition and are not allowed to become
damaged while in use. Avoid positioning the cord in the trafc lane and it is always kept out of the way.
Take this furnishing out of service immediately if the cord or plug becomes damaged in any way.
• Do not attempt to repair. All repairs must be performed by an authorized service representative.
1. RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground-fault
circuit-interrupter (GFCI).
2. Grounding is required. The unit must be installed by a licensed electrician and
grounded.
This product must be grounded. If it should malfunction or break down, grounding provides a path of
least resistance for electric current to reduce the risk of electric shock. This product is equipped with
a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
Improper connection of the equipment-grounding connector can result in a risk of electric shock. Check
with a qualied electrician or serviceman if you are in doubt as to whether the product is properly grounded.
Do not modify the plug provided with the product - if it will not t the outlet, have a proper outlet installed by
a qualied electrician.
INSTALLATION INSTRUCTIONS / GROUNDING INSTRUCTIONS
Reset
Button
GFCI Outlet
Grounding Pin
Test
Button
IMPORTANT: See separate
installation instructions
for detailed installation
information.

SECTION 2: PRODUCT OVERVIEW
4
Chair Swivel
Release
Drain Pump
Button
(Optional)
*Chair shown with oponal nishes
Sprayer/Fill
Electronic
Footrest
Client Controls
Drain Pump
Button
Drain
Release
Cupholder
Water Fill
Valve
Pipeless Jet
Light Button
Jet Button
Technician
Controls
Vent
USB Port

Length 61.25” (156 cm)
Width 36” (92 cm)
44.75” (113 cm), with side trays
Overall Height 52” (132 cm)
Seat Height 23.5” (60 cm)
Weight Capacity 300 lbs
Basin Capacity 5.7 gallons
*Measurements may vary due to natural material variaons.
5
Feature Standard Oponal
Power chair posioning/recline X
Pipeless magnec jet system X
Glass Basin X
Swivel seat X
Relaxor Heat & Massage X
Dual client/tech seat controls X
Cupholder X
Integrated Venlaon X
USB Port X
Drain Pump X
Manicure trays X
Full concealment side panels X
Upholstery Premium
Ultraleather
Custom
upholstery
Included Features
Product Specications
SECTION 2: PRODUCT OVERVIEW

SECTION 3: OPERATING INSTRUCTIONS
6
Leveling Your Chair
Leveling, or balancing, your chair is very important during ini al setup and rou ne maintenance.
Your Maestro Opus is equipped with six (6) leveling feet.
NOTE: Leveling feet have been adjusted prior to shipment - in most cases no further adjustment
should be necessary. The en re pedicure chair may be raised or lowered slightly to ensure the
technicianʼs chair touches the front stainless steel guard and not the wood or Formica®
To adjust the leveler feet:
1. Place the chair in the posi on you plan to use it.
2. To determine which foot needs adjus ng, a empt to “rock” the chair. If there is any
movement, the leg that is li ing is the one that will need adjus ng.
3. Using your hand, or a wrench if necessary, turn the leveling foot in the needed direc on.
(Counterclockwise will lower the overall height, clockwise will raise the overall height)
Filling the Tub
Locate the chrome hot/cold water valve handle on the front of your pedicure chair. This valve
handle controls both the fl ow of water and the temperature of water. Note: The sprayer/ ller
has a dual func on; it is both a sprayer and ller for the basin.
When desired water temperature is achieved, close “Pop-Up” in bo om of basin by turning
chrome drain handle located on right side of the base. (Figure 2)
When water level reaches a point approximately one (1) inch ABOVE the top edge of the jet (or
the ll line indicated by a s cker in the basin), shut water o by pressing down on the handle.
There is no automa c shuto with the water ll valve. You MUST turn the
valve OFF a er the tub is lled to prevent overfl ow and/or fl ooding. Do not
walk away from the tub when it is lling with water.
Turn Right
for Cold
Turn Le
for Hot
Turn to close
pop-up drain
Drain Pump
Bu on (Op onal)

7
SECTION 3: OPERATING INSTRUCTIONS
Jet System
The pipeless “magne c” system is standard in your pedicure unit. A er basin is lled to proper
level, turn jet on by pressing the chrome bu on marked “JET”. To turn o , press “JET” bu on a
second me.
NOTE: Liners can be used on a “magne c” system. The liner has to sit between the motor
housing and the wet end assembly.
The jet assembly must be correctly assembled or it may be damaged. This
will NOT be covered by any Con nuum warranty. Never turn the jet on
without adequate water in the basin. There must be at least one (1) inch of
water above the motor housing.
Draining the Tub
1. Gently turn drain handle located on right side of base. This ac vates “Pop-Up” located on
bo om of basin allowing water to drain.
2. Wait for the air bubbles to exit. Press chrome bu on marked “DRAIN” to ac vate pump.
3. When basin is fully emp ed, press bu on again to turn the pump o .
NOTE: Drain pump will automa cally turn o in four (4) minutes if bu on is not pressed a
second me
Drain Pump
Bu on (Op onal)
ALWAYS perform Step 1 before Step 2. Never reverse the steps as this may
cause the “Pop-Up” to become jammed in the waste assembly.
Drain Handle
Correctly
placed
impeller
Jet
Cover
Jet housing

SECTION 3: OPERATING INSTRUCTIONS
8
Electrical Specications
Spec North America Europe/Asia
Input Voltage 120 VAC 220 VAC
Input Frequency 60 Hz 50 Hz
Total Consumpon
- Standard Features 9A 4.5A
Technician Controls
See below for technician controls funconality.
Raise/lower
right footrest Slide seat
forward/backward
Always use extreme cauon when making any posion adjustments to the
chair. Ensure all body parts and objects are clear from all moving parts.
Raise/lower
le footrest
Chair Swivel
The Chair Release Lever is on the le side of the chair. Gently li up on the lever allowing the
chair to swivel. This must be done each and every me a client enters or exits the chair.
Please note: In order for the chair locking mechanism to work properly, one must sit normally
in the chair, that is to say, NOT on the outer edge of the chair, but rather sing back in the
chair. This allows for the locking pin to engage and disengage easily.
When entering: Li lever allowing chair to swivel either le or right. With client seated, swivel
chair to front posion unl a click is heard. This safely locks the chair in place.
When exing: Li lever allowing chair to swivel either le or right unl a click is heard. This
safely locks the chair allowing exit.
Make sure each client moves slowly and carefully. ONLY enter and exit chair
when it is in a locked posion.

SECTION 3: OPERATING INSTRUCTIONS SECTION 3: OPERATING INSTRUCTIONS
9
Embedded Client Control
The following photo shows the funconality of the Maestro Opus embedded control.
Slide seat forward/backward
Seat base lt increase/decrease
Seat back lt increase/decrease
Relaxor Heat & Massage Hand Control
Power
High Heat
Low Heat
Massage All Zones - Connuous
Massage All Zones - Sequenal
Massage All Zones - Short Bursts
Zone 1
Massage
Zone 2
Massage
Lower
Intensity
Raise
Intensity
Raise
Speed
Lower
Speed
RISK OF ELECTRIC SHOCK
Keep hand control and all electrical components away from water.

SECTION 4: CARE & MAINTENANCE
YOU ARE REQUIRED TO CHECK WITH YOUR STATE BOARD FOR MANDATORY CLEANING AND
DISINFECTING REQUIREMENTS AND PROCEDURES.
The following procedures are important guidelines that will help in keep your Maestro Opus
clean and trouble free for years. It is extremely important to clean and disinfect every pedicure
chair aer each pedicure and aer the last pedicure of the day. (See next page for instrucons.)
Cleaning & Ongoing Maintenance
DO NOT USE acetone, paint thinner, bleach, “Armor All” type cleaners, or
industrial cleaners for ANY part of your chair, tub, or components.
DO NOT place nail care products on the tub.
Extended exposure to chemicals like bleach can damage the basin, footpad, and/or upholstery.
Failure to comply with all cleaning instrucons can cause damage and void your warranty.
Category Care/Maintenance Recommendation
Formica
Finishes
Formica nishes require very lile maintenance. Wipe dry any water that
may splash onto the Formica.
Glass Basin
DO NOT use abrasive pads or cleaner on any part of the glass basin. Wipe
clean with a sponge or so brush. Follow State’s cleaning and disinfecng
procedures.
Most Dirt &
Residue
Use soapy water, ammonia based cleaner, (not window cleaner) rinse and
wipe completely dry. Commercially avail- able solid surface cleaners, such as
Clean Encounters will also work well.
Prevent Hard
Water Marks Rinse and wipe completely dry aer cleaning.
Remove Hard
Water Marks
Use cleaner formulated for removing hard water marks, such as CLR or
Lime-A-Way.
Stubborn
Dirt, Stains, or
surface imper-
fecons
Occasionally stains will not be removed by the above steps, in this case the
use of a Mr. Clean® Magic Eraser will allow for a more aggressive cleaning
without damaging the surface nish. Use the Magic Eraser following the
direcons on the package.
Upholstery Simply use a mild detergent (very lile) with warm water and gently clean
any dirt or grime that may appear on the seat, seat back or arms.
Footrests
A mild detergent and warm water is all that is needed to clean the padded
footrests. However care should be taken to prevent nail polish or acetone
from coming in contact with the footrests. These products may damage or
discolor the outer “skin” of the foam. In spite of taking necessary precau-
ons to protect the footrests, hard water and/or certain products many
cause the black footrests to develop a white lm or some discoloraon. If
this occurs, a product called “Black Max”- Vinyl and Rubber Dressing works
well to restore the footrests.
NOTE: DO NOT USE THE NYLON SCOURING PAD ON THE FOOTRESTS.
10

SECTION 4: CARE & MAINTENANCE
Tub Cleaning Guide
YOU ARE REQUIRED TO CHECK WITH YOUR STATE BOARD FOR MANDATORY
CLEANING AND DISINFECTING REQUIREMENTS AND PROCEDURES
The removable wet-end assembly MUST be placed onto the motor housing in the correct
posion of the jet may be damaged. The wet end housing must t in the proper groove onto
the motor housing. If the wet end is not posioned correctly, damage to the jet may occur due
to misalignment. This will NOT be covered by any Connuum warranty. Never turn the jet on
without adequate water in the basin. There must be at least one (1) inch of water above the
motor housing.
Recommended Cleaning and Disinfecting Products
Your state board requires disinfecng of your pedicure basin. Connuum recommends “Splish
Splash One-Step Disinfectant.” While other EPA registered products are available for maintaining
pedicure tubs, we have found Splish Splash to be the most eecve, mul-purpose and
economical product on the market.
11
Cleaning After Each Client & End of Day
1. Turn o the jet and drain all water from the basin.
2. Aer the motor has completely stopped, twist the cover from the housing to expose the
impeller.
3. Remove the wet end consisng of the cover, impeller, and housing from the jet.
4. Clean all 3 wet end parts with a brush, liquid soap, and water to remove all visible residue.
Reaach all 3 parts to the motor housing, ensuring the wet end is placed in the proper
groove on the jet housing.
5. Fill basin with warm water and add the correct amount of an EPA-registered liquid
disinfectant (Splish Splash strongly recommended). Turn on the jets to circulate the water
for at least 10 minutes, scrubbing all visible residue from the inside walls of the basin with
a sponge/so brush. NOTE: Brushes must be cleaned/disinfected aer each use.
6. Drain the basin, rinse with fresh water, and wipe dry with a clean paper towel.
NOTE: THE ABOVE SHOULD BE FOLLOWED EVEN IF TUB LINERS ARE USED
The use of oil-based products can build up in the whirlpool system causing clogging in the jet
and build up onto the surface of the basin. Adherence to the above cleaning will minimize build
up but the manufacturer recommends not to use mineral oil based products.
Cleaning Every Other Week
1. Fill tub with water and one-third (1/3) cup of 5.25% chlorine bleach for each one (1)
gallon of water. (An alternave to bleach would be an EPA-registered disinfectant with
demonstrated bactericidal, fungicidal, and virucidal acvity.)
2. Turn on the jets to circulate the soluon for 5-10 minutes and then sit for 6-10 hours.
3. Drain the basin, rinse well with fresh water, and wipe dry with a clean paper towel.

12
SECTION 4: CARE & MAINTENANCE
This helpful troubleshoong guide will provide you with informaon about how to recognize a
problem with your product, determine possible causes, and nd a soluon.
In the event your specic situaon is not covered in this guide, please contact Connuum so our
technical support department can assist you. Beyond the troubleshoong guide below, do not
aempt to repair the issue yourself. This can void your warranty.
Unauthorized service will not be covered. Please be sure to contact Connuum Customer Service
rst at (877) 255-3030, (760) 597-5707 Int’l.
Troubleshooting
Issue Solution
No Power/Not
Operang
1. Ensure the power cord is properly plugged into an operaonal GFCI
power supply/outlet.
2. Check GFCI reset and circuit breakers or fuses.
3. Ensure the outlet in your room is receiving power. This can be done
by plugging in a small appliance and turning it on.
No Power to Jet/
Jet not
Operang
1. Ensure the power cord is properly plugged into an operaonal GFCI
power supply/outlet.
2. Check GFCI reset and circuit breakers or fuses.
3. Ensure impeller is correctly installed in the case.
4. Reset the motors by unplugging the system, waing 5 seconds, then
plugging in again.
Excessive Noise
from Jets
1. Remove jet assembly and inspect for dirt buildup, debris, or damage.
2. Follow cleaning instrucons or replace if necessary.
Water Leakage
1. Check and ensure all visible bolts are ghtened.
2. Call a plumber to determine the source of the leak.
3. If the leak is from the jet system, contact customer service.

13
SECTION 4: CARE & MAINTENANCE
Connuum Footspas has designed and manufactured their pedicure chairs to the
highest standards. Accordingly, Connuum Footspas oers an industry best warranty
as follows:
• Motors and controls, actuators, foam and upholstery are warranted for two
(2) years, including parts and labor unless otherwise noted.
• Glass parts are warranted for one (1) year.
• Accessories and replacement parts are warranted for ninety (90) days from
date of shipment.
Connuum may repair or replace defecve components at our discreon. Connuum
will return the warranted product, standard shipping pre- paid, to customers in the
connental US. Internaonal customers are responsible for any applicable dues and
taxes, as well as all shipping charges inbound and outbound.
Excluded from Limited Warranty:
1. Unauthorized repairs.
2. Damage due to freight, accident, natural disaster, and/or abuse.
3. Damage or malfuncons due to improper installaon including but not lim-
ited to, failure to comply with all naonal, state, and local plumbing, electri-
cal, and building codes.
4. Fading, discoloraon, or staining of any part due to improper water addi-
ves, hard water, or harmful cleaning agents or chemicals.
5. Damage to drain pump due to obstrucon in drain hose and/or debris in
pump impeller housing.
All warranes are limited to repair or replacement, at Connuum’s discreon, unless
otherwise stated. This limited warranty applies only to pedicure chairs installed in any
one of the y (50) States of the United States, the District of Columbia, or provinces
of Canada.
• Jet cover and/or impeller
• Footrest/leg supports
• On/o air actuated buon
• Pedicute model
• Black plasc parts
• Manicure trays
• Replacement upholstery
• Faucet cartridge and/or ller-sprayer
• Roller massage or Relaxor heat +
massage system
• Any LED light
• Handheld control wands
• Any internaonal shipment includ-
ing but not limited to Canada and
Mexico
Parts and/or circumstances for which labor is NOT COVERED - Parts noted below are
simple to replace and DO NOT require a service technician:
Warranty Information

Contact Us
Continuum
990 Joshua Way
Vista, CA. 92081
(877) 255-3030
(760) 597-5707 Int’l
Hours of operation:
Monday - Friday
8:00 a.m. to 5 p.m. PST
Saturday - Sunday
Closed
Visit us online at: mycontinuumpedicure.com
Join us on
Facebook
Follow us on
Twitter
Connect with us
on Linked In
Follow us on
Instagram
Other manuals for Maestro Opus
1
Table of contents
Other Continuum Pedicure Spa manuals