INPUTS
OUTPUT
Eight digital inputs coming from SPST contacts can be wired to terminals 7-14.
Common return for contacts at terminal 6.
Using electronic switches, terminal 6 is the positive leg.
In order to avoid false triggering, contacts will be considered closed or open after
3 seconds from stable condition.
Modifying the configuration by means of GsmSuite, either in local or remote mode
it will be possible to change:
Debounce time from 1 to 99 seconds.
Enable and disable input closing detection.
Enable and disable input opening detection.
Contact voltage < 20 V
Contact current<2mA
9 x 2.5 mm (AWG14) screw connector
Process or appliance can be controlled by means of 1 SPST relay contact
available between terminals 3-4.
Rated current 4 A
Rated voltage 250 Vac
Max breaking capacity 2500 VA
Minimum contact load 100 mA, 12 V
Cadmium free contacts
Insulation 250 V (IEC60664 / VDE0110b - cat. III / C)
Surge voltage coil contacts: 4000V
Dielectric strength coil-contacts 2500V
open contact circuit 1000V
4 x 2.5 mm (AWG14) screw connector
¡
¡
¡
DC
RMS
RMS
RMS
2
2
DECLARATION OF CONFORMITY
R&TTE Directive 1999/5/EC
Manufacturer: Contrive, Srl
Via Enrico Fermi 18 24040 Suisio Italy
Brand: Contrive
Equipment name:GsmAlarm+ / GprsAlarm+
Equipment type: GSM/GPRS modem
EMCC DR. RAŠEK, GmbH
Moggast, Boelwiese 5
91320 Elbermannstadt Germany
Company identification:
Product identification:
We declare on our sole responsibility, that the product described above
is in compliance with the essential requirements of the 1999/5/CE Directive:
EN 301 489-1
EN 301 489-7
EN 61326
EN 55024
EN 300 607
and all tests were carried out
Notified Body:
Health and safety requirements pursuant to clause 3.1a:
Protection requirements concerning EMC clause 3.1b:
Measures for the efficient use of the radio frequency spectrum clause 3.2:
EN 301 511
EN 60950-1
GSM900/1800 essential requirements for mobile stations
Safety of information technnology equipment
Electromagnetic compatibility
ElectroMagnetic compatibility and Radio spectrum Matters
Specific conditions for mobile and portable radio and ancillary equipments
ElectroMagnetic compatibility measurement, control and laboratory use
Information technology equipment - Immunity characteristics
Radio spectrum matters
NOTE: Class B equipment (domestic) emission level applied.
Class A equipment (industrial) immunity level applied.
Suisio, Italy February 21, 2006
¡
¡
¡
CONTRIVE RESERVES THE RIGHT TO MODIFY THE CHARACTERISTICS STATED
IN THIS INSTRUCTION MANUAL AT ANY TIME AND WITHOUT PRIOR NOTICE.
© COPYRIGHT 2002...2005 CONTRIVE SRL ITALY. ALL RIGHTS RESERVED.
GsmAlarm+A
GsmAlarm+X
The embedded antenna is located under the front panel. This omnidirectional
antenna can work properly if the front side of the device is not shielded by metallic
frames (i.e.: the GsmControl+A is installed inside a metal cabinet).
An external dual-band antenna must be connected to the RF interface, implemented
as a 50 FME male coaxial jack at the end of a short RG174 cable stub exiting from
the top side of the device. The antenna must fulfil the requirements given below:
We recommend a VSWR max of 1.5:1 although a VSWR max of 2:1 can be accepted
without affecting performance and certification.
The DC impedance is floating but there is no problem when using antennas that
present a short to ground.
W
CONTRIVE S.R.L.
Via Enrico Fermi 18 I-24040 SUISIO (Bergamo)
Tel. +39 (0)35 4948236 Fax +39 (0)35 4933759
B1018.EN / 0211 www.gsm-control.biz
Dual band EGSM900 and GSM1800 for data, sms, fax and voice applications
Full Type Approved and compliant with ETSI GSM Phase 2+
Output power: Class4(2W@900MHz)
Class1(1W@1800 MHz )
Temperature: operating -20 to 55°C
storage and transport –30 to 85°C
Relative humidity: operating 5 to 95% non-condensing
storage & transport 5 to 95% condensation allowed outside
Enclosure: EN-50022 rail 4 modules, polycarbonate, UL94 -V0
Overall dimensions: mm 71 x 90 x 58(WxHxD)
Weight: 200 g
Degree of protection: IP 40 ( IEC 529) properly fittedEN-60529 /
Power supply: 12 V DC ±20% polarity independent
12 V AC ±20%
< 30 mA @ 12 V DC in standby mode
< 100 mA @ 12 V DC in standby mode, relays ON
< 200 mA @ 12 V DC in communication mode
< 1 A @ 12 V DC max peak current
2 x 2.5 mm (AWG14) screw connector
This unit can be supplied either by alternating or direct current, polarity
independent. Power supply connection on terminal 1 and 2, top right side.
The power supply unit must meet the demands placed on SELV [1] circuits in
accordance with EN60950.
The power supply must not be shared with other equipment: suggested power
supply source is a simple 12VAC / 5VA transformer.
The maximum permissible connection length between device and supply source
is 3 m. Overvoltages are suppressed by internal varistor.
[1] Safety Extremely Low Voltage
2
This device should be installed only by qualified personnel. Carefully read the
instruction manual in its entirety and keep it safe for future reference.
It is essential to know the information and comply with the instructions given in the
manual to ensure the fitting is installed, used and serviced correctly and safely.
This RF unit is not designed for and intended to be used in portable applications
(within 20 cm or 8 inches of the body of the user) and such uses are strictly prohibited.
This unit is not authorised for use as critical component in life-support devices or
systems unless a specific written agreement has been given.
If incorrectly installed in a vehicle, the operation of GSM device could interfere with
the correct functioning of vehicle electronics. Verification of the protection of vehicle
electronics should form a part of the installation.
Regulations must be considered to operate a vehicle’s light or horn on public roads.
No complex software or hardware system is perfect.
Bugs are always present in a system of any size.
In order to prevent danger to life or property, it is the responsibility of the system
designer to incorporate redundant protective mechanism appropriate to the risk
involved.
All units are 100% functionally tested. Specifications are based on characterisation
of tested sample units rather than testing over temperature and voltage each unit.
Contrive disclaims all liability for damage to the fitting or to other property or persons
deriving from installation, use and maintenance that have not been carried out in
conformity with this instruction manual, which must always accompany the fitting.
The GsmAlarm+ is an industrial DIN rail GSM modem for the supervision and control
of remote inputs and outputs by means of enhanced features available through GSM
network.
Industrial standard interface and an integrated SIM card reader mean it can be used
rapidly, easily and universally to quickly implement new applications in telemetry,
telematics and remote control. All interfaces are integrated in the housing.
The connections are suitable for use in domestic and industrial environments.
DIMENSIONS [mm]
SAFETY INFORMATION
PRODUCT FEATURES
ANTENNA
PRODUCT DESCRIPTION
58
90
71
r
If the device has been stored in a cold environment, then condensation can
occur. Before starting operations, the device must be absolutely dry.
Thus, an acclimatization period of at least three hours must be observed.
In order to avoid possible damage, we recommend that you only use the
specified accessories.
These have been tested and shown to work well with this unit.
i
Do not install this unit near medical devices like pacemakers or hearing
aids. This unit may interfere with the operation of these devices.
Switch off this unit when flying.
Secure it so that it cannot be switched on inadvertently.
Do not install this unit near petrol stations, fuel depots, chemical plants or
blasting operations when this unit can disturb the operation of technical
equipment.
Interference can occur if this unit is used near televisions, radios or
personal computers.
BUILT ON PROVEN TECHNOLOGY
POWER SUPPLY
INPUTS / OUTPUT
Frequency TX
Frequency RX
Impedance
VSWR
TX max
RX max
Polarization
Typical gain
880 to 915 MHz
925 to 960 MHz
50 ohms
1.5:1
1.5:1
Linear
0 dBi in one direction at least
1710 to 1785 MHz
1805 to 1880 MHz
12345678
INSTALLATION
This unit can be installed on any standard EN-50022 rail by simple snap-in.
A minimum protection degree IP40 must be guaranteed, raised to IP54 for open-
air application.
A. Power Supply input
2 x 2,5mm (AWG14)
B. Input and output terminals
12 x 2,5mm (AWG14)
C. Input red led status indicators
D. Output green led status indicator
X. External antenna (type X only)
RG174 + FME male jack
S. GSM operation LED indicator
OFF
No power supply
ON
Module switched ON
Not registered on the network,
missing SIM or invalid PIN
SLOW FLASH
Module switched ON
Registered on the network
QUICK FLASH
Module switched ON
Registered on the network
Communication in progress
2
2
¡
¡
¡
¡
PERMANENTLY
200ms ON / 2s OFF
200ms ON / 600ms OFF
à
õ
õ
X
A
B
1
131211
10
987654
3
2
14
SD C
Your GsmAlarm is the product of advanced engineering, design and craftmanship
and should be treated with care. The suggestion below will help you to enjoy this
product for many years.
Both fixed and mobile applications are allowed, as defined below:
means that the device is physically secured at one location and is not able
to be easily moved to another location.
means that the device is designed to be used in other than fixed locations
and generally in such a way that a separation distance of at least 20 cm (8 inches)
is normally maintained between the transmitter’s antenna and the body of the user
or nearby persons.
Do contact an authorized service center in the unlikely event of a fault in the unit.
¡
¡
¡
¡
¡
¡
¡
¡
¡
¡
Do not expose the unit to any extreme environment where the temperature or
humidity are out of operating range.
Do not use or store the unit in dusty or dirty areas. Its moving parts (SIM holder for
example) can be damaged.
Do not use chemical cleaning agent on the unit or the SIM card.
Do not attempt to disassemble the unit or remove any part or label.
There are no user serviceable parts inside.
Do not expose the unit to water, rain or spilt beverages. It is not waterproof.
Do not abuse the unit by dropping, knocking or violenty shaking it.
Rough handling can damage it.
Do not place the unit alongside computer discs, credit or travel cards or other
magnetic media. The information contained on these devices may be affected.
This unit is under your responsibility. Please treat it with care respecting all local
regulations. It is not a toy. Therefore, keep it in a safe place at all times and out of
the reach of children.
Treat the SIM card with the same care as your credit card: do not bend or scratch
or expose it to static electricity.
Try to remember your unlock and PIN codes. Become familiar with and use the
security features to block unautorised use and theft.
Fixed
Mobile
CARE AND MAINTENANCE
0678
1018.01.00 GsmAlarm+A
1018.02.00 GsmAlarm+A
1018.01.01 GsmAlarm+X
1018.02.01 GsmAlarm+X
1018.01.10 GprsAlarm+A
1018.02.10 GprsAlarm+A
1018.01.11 GprsAlarm+X
1018.02.11 GprsAlarm+X
EMBEDDED ANTENNA
EMBEDDED ANTENNA + BACKUP BATTERY
EXTERNAL ANTENNA
EXTERNAL ANTENNA + BACKUP BATTERY
EMBEDDED ANTENNA
EMBEDDED ANTENNA + BACKUP BATTERY
EXTERNAL ANTENNA
EXTERNAL ANTENNA + BACKUP BATTERY
B
B
B
B
GsmAlarm+
GSM REMOTE MONITOR
GSM/GPRS REMOTE MONITOR
GprsAlarm+
USER GUIDE 12345678
THE INFORMATION CONTAINED IN THIS DOCUMENT ARE SUBJECT TO CHANGE
WITHOUT NOTICE. PRODUCT NAMES, CORPORATE NAMES OR TITLES USED WITHIN
THIS DOCUMENT MAY BE TRADEMARKS OR REGISTERED TRADEMARKS OF OTHER
COMPANIES AND ARE MENTIONED ONLY IN AN EXPLANATORY MANNER TO THE
READERS’ BENEFIT,AND WITHOUT INTENTION TO INFRINGE.
WHILE EVERY EFFORT HAS BEEN MADE TO MAKE SURE THE INFORMATION IN THIS
DOCUMENT IS CORRECT, CONTRIVE CAN NOT BE LIABLE FOR ANY DAMAGES
WHATSOEVER FOR LOSS RELATINGTOTHIS DOCUMENT.
WARRANTIES
CONTRIVE GUARANTEES FOR TWO YEARS FROM THE DATE OF MANUFACTURE OF
ITS PRODUCT TO REPLACE, OR, AT ITS OPTION, TO REPAIR ANY PRODUCT OR PART
THEREOF WHICH IS FOUND DEFECTIVE IN MATERIAL OR WORKMANSHIP OR WHICH
OTHERWISE FAILS TO CONFORM TO THE DESCRIPTION OF ITS SALES ORDER.
CONTRIVE MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER
WARRANTY EXPRESS OR IMPLIED. IN NO EVENT SHALL CONTRIVE BE LIABLE FOR
CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY NATURE WHICH MAY ARISE IN
CONNECTION WITH SUCH PRODUCTS.
THE WARRANTY DOES NOT APPLY IN CASE OF IMPROPER USE

Following a typical status SMS issued on request:
Short description
Detailed device application info
input closed
input open
input open
input open
input open
input open
input open
input open
remaining time to output off
clip mode and status
Main power failure detected
output inactive
output active, remaining time to disable could follow
output active and latched
pulse clip sequence in progress
input open, inactive
Building 1
Apt. 5 living room
In 1 :close
In 2 :open
In 3 :open
In 4 :open
In 5 :open
In 6 :open
In 7 :open
In 8 :open
Out1: on 00:01:22
Clip:pulse on
Blackout
off
on
!on
|
open
Out status:
In 1 - 8 status:
Serial c
Before opening the unit disconnect
power supply and all live circuits
that may be connected.
ommunication port and
optional backup battery are located
inside the unit.
The front cover must be removed to
access the inside of the unit :
1. Push with two fingers on
top and bottom sides of
front cover to release it.
2. Pull the front cover and
keep it in a safe place.
The newer NiMH batteries are less harmful to the environment, have a longer life,
and contain recyclable materials. Recycling options available in your local area
should be considered when disposing of this product. Do not dispose of in fire.
The SIM card receptacle is intended for 3V SIM cards [GSM 11.12 phase 2+].
The SIM card must be inserted in the cardholder to put the unit into operation.
Make sure that there is no voltage applied to GsmControl+.
Disconnect also the backup battery, if any. Following the figure below:
1. Unlock the top cover using
a small screwdriver.
2. Slide up the top lid.
3. Insert the SIM card in the
receptacle, contacts must be
on the bottom side.
To remove the SIM
card repeat operations
1 and 2, gently pull the
SIM card out.
Do not operate without top cover, once the
SIM card has been inserted replace the top
lid and then connect power supply.
ADVANCED CONFIGURATION, LOCAL CONTROL, TRACING AND OTHER
FEATURES ARE AVAILABLE THROUGH SERIAL COMMUNICATION LINK
Specific literature and software for PC running Microsoft Windows are
available for free download at .
Remove the front cover following the instructions to access the RJ45 8 pin
modular jack serial interface [P].
Link cable is available from local resellers.
Communication: RS-232 (DCE)
300 ... 115200 bit/s
7/8 data bits, 1/2 stop bits, 1 parity bit, 10/11 bit char length
Software handshake, Hardware handshake
GsmSuite
www.gsm-control.biz
1013.00.02
®®
RJ45 PINOUT
1. GND
2. RTS
3. GND
4. CTS
5. GND
6. TxD
7. GND
8. RxD
DB9-5
DB9-7
DB9-8
DB9-3
DB9-2
1
131211
10
987654
3
2
14
õ
P
If the unit is provided with UPS
feature, a backup battery can be
installed to keep the device
working even during power failures.
Once the front cover has been
removed:
1. Clip the battery to available
connector. This connector
must be isolated when
operating without backup
battery.
2. Push the battery into
retainer lids located under
front cover.
3. Replace the front cover to
close the unit.
Use only NiMH rechargeable
batteries 8.4V or 9.6V type.
WHEN USING BATTERIES AND
ACCUMULATORS ADHERE TO
RELEVANT REGULATIONS
ACCESS INSIDE BACKUP BATTERY
FREE CLIP CONTROLCONFIGURATION
COM PORT
1
2
3
18
1
2
3
SIM CARD
Any registered user can control the output by means of SMS.
Following default commands can be changed to any custom text using .
More details available on .
Set output 1 ON [3]
Reset output 1 OFF
Set output 1 ON and LATCH (set again at further power on) [4]
Pulse output 1 (1...59 seconds, default 3”)
Status SMS request
Ringback request once command has been processed
Commands will be recognized both uppercase, lowercase and mixed, nested
within other text wherever placed inside the incoming SMS.
Multiple commands into same SMS are allowed.
[3] Specifying a time interval after the set command, output will be released
once set time has elapsed. If a power failure occurs, the remainig time is
missing, thus the output will be released. Commad syntax:
days
hours
minutes
[4] Specifying date/time after the set and latch command, output will be
released at specified expiry date/time. Output status will be recovered after
blackout providing the real time clock sync has been performed successfully.
day
month
year -
hours -
minutes -
Example:
turn ON output for 8 hours and 30 minutes,
send back a status SMS
turn on and latch the output until April 25, 2006 12:30
turn ON output,
GsmSuite
“Advanced Manual”
00 - 99
00 - 23
00 - 59
01 -31
01 - 12
00 99
00 23
00 59
S1
R1
M1
P1
D
B
S1ddhhmm dd
hh
mm
M1ddmmyyhhmm dd
hh
hh
hh
mm
S1000830 D
M12504061230
s1 B
text alien trailer
alien trailer
SMS CONTROL STATUS SMS
Registered users can control outputs by means of simple (free) calls. Supervisors
can set different activation times and outputs behaviour issuing an SMS:
On time
Time to answer in toggle mode
none, pulse, toggle, reverse,dtmf
Clip feature is disabled, nothing happens on incoming calls from registered users.
Selecting this mode, incoming voice (or fax) call from registered user will turn on
the output for the time set in .
Incoming voice (or fax) calls will toggle the output on to off or vice-versa.
A ringback will be issued only when an output is turned on.
If the user waits online, after the time specified in GsmAlarm+ will answer,
playing a low tone after output release or four high tones after output activation.
No ringback will be issued in such case.
+2,290,,,pulse,,,,answ,mode
pulse
answ
mode
01 - 60” default 3”
01 - 60” default 15”
NONE
PULSE (default)
TOGGLE
pulse
answ
2
1
1
Operating without SIM PIN
Enter default SIM PIN
0000
Change default SIM PIN
GsmSuite
WARNING
The simplest way is to put your SIM card into a cellular phone and
program it so it won't ask for the PIN. The SIM card is 'open' and
someone could steal the SIM card, use it and read the information inside.
GsmControl+ comes with a default PIN = (four zeroes).
Put your SIM card into a cellular phone and program the PIN using the
given number.
Using com port and running on Microsoft® Windows®
PC you can modify the default PIN on both GsmControl+ and SIM card.
If you insert a SIM card that asks for a PIN number different from
that stored into GsmControl+, the device will not operate.
If you enter the PIN 3 times incorrectly, SIM card will lock up and you
must provide the PUK (PIN Unblocking Key).
Add Users (group 0)
Store first supervisor
Remote control is allowed to registered users only.
It's possible to add, modify or delete subscribers
from the SIM card phonebook using any GSM
mobile phone or SIM card reader/writer.
Following operating instructions provided by
phone manufacturer insert the SIM card into the
SIM card holder, turn on the phone and scroll the
option menu to enter the SIM card Phonebook edit
mode.
Enter the users name and telephone number using international format.
Insert the SIM card into the device SIM card holder and turn on the power supply,
the unit is ready to operate.
Although it is not mandatory to store a supervisor, you may add a supervisor who
then has additional special commands only available to him (advanced manual).
To store the first supervisor, once the unit is operative, issue the following SMS:
start character
system PIN (default = 0000)
supervisor’s name to be stored
optional email address
end character
Example:
The telephone number of SMS sender is automatically collected from the
incoming call presentation (thus the telephone number must be kept visible) and
will be assumed as the first supervisor’s telephone number.
First supervisor will be stored at position 401 and the unit will send back a
confirmation or error SMS.
Dots are allowed ONLY within the email address field.
It’s possible to use both and @ characters before the domain name.
SMS delivery failure is usually less than 1% but you must keep in mind
that a message could not arrive and you cannot complain with your
#xxxx.Name.email*
#
xxxx
Name
email
*
#0000.Harry [email protected]*
4 CHARACTERS
14 CHARACTERS MAX
40 CHARACTERS MAX
?
To identify your device more easily, you can store some specific information.
A supervisor can issue the following SMS:
Device own phone number [1]
Short description
Optional device own email address [2]
Detailed device application info
Example:
and will be shown within status SMS sent by this unit.
[1] Device phone number (always in international format) will be used to perform
real time clock autosync, missing this field the real time clock is unreliable and
SMS commands involving date field will be rejected.
[2] All email issued from Gprs type unit will be sent carbon copy also to its own
+3,300,tel,info,,,,,email,text
tel
info
email
text
+3,300,+4456789,Building 1,,,,,,Apt. 5 living room
info text
20 CHAR MAX
14 CHAR MAX
40 CHAR MAX
56 CHAR MAX
QUICK START
SIM PIN DEVICE INFO
Special control SMS are reserved for supervisors only:
Disable / enable free calls control feature (CLIP).
An SMS reporting last # (1-9) answered / unanswered call list will be sent.
Full list specifying 0.
An Email reporting the complete phonebook will be issued to supervisor’s email
address, if any (GPRS only). Pbook ++ will return phonebook + settings.
Stop / Start
Lista# / Listu#
Pbook / Pbook++
Add Recipients (group 9)
Add / edit Supervisors (group 7)
Add / edit Users (group 0 / group 1)
Delete Phonebook entries
GPRS / Email settings
Alerts following local events can be issued to Recipients (upto 100).
Recipients stored in the internal memory of GsmAlarm+ can be modified using
GsmSuite with local link or by means of SMS issued by supervisors:
Phonebook index
Destination for phone calls [1]
Recipient’s name
Destination for SMS alerts [1]
Specific event Blackout
Input 1 closing
Input 2 closing
Input 3 closing
Input 4 closing
Input 5 closing
Input 6 closing
Input 7 closing
Input 8 closing
Power good
Input 1 opening
Input 2 opening
Input 3 opening
Input 4 opening
Input 5 opening
Input 6 opening
Input 7 opening
Input 8 opening
Remote tracing of all events
Destination for FAX alerts [1]
Destination for Extended SMS alerts [1]
Destination for email alerts [2]
Text of the message
Example:
Using GsmSuite is possible to configure advanced features, either linking the unit
with local com port or issuing SMS in remote mode. Refer to GsmSuite help file or
Advanced Manual for detailed information. Most important advanced features:
Up to 100 supervisors can be stored inside the unit.
Users can be stored into SIM card phonebook.
Conditional users (having more features) can be stored into device memory.
Remove any entry from phonebooks by means of GsmSuite or issuing an SMS.
Emails service configuration, available for GPRS devices.
+9,iii,Ring,Name,SMS,Event,Fax,XSMS,Email,Text
iii
Ring
Name
SMS
Event 00:
01:
02:
03:
04:
05:
06:
07:
08:
10:
11:
12:
13:
14:
15:
16:
17:
18:
30:
Fax
XSMS
Email
Text
+9,301,+44987654,Harry,,01,,,[email protected],fire
+9,302,,Harry,,00,,+44987654,,power fail
+9,302,+44987654,Harry,+44987654,30
301 ÷ 400
20 CHAR MAX
14 CHAR MAX
20 CHAR MAX
20 CHAR MAX
20 CHAR MAX
40 CHAR MAX
56 CHAR MAX
Harry will receive both a phone call and an Email message when input 1 is
closing, the text of the message will be “fire”.
Harry Potter will receive an (extended) SMS including a complete status
report and the specific alert text “power fail“ detecting blakouts.
Harry Potter will receive both a phone call and an SMS at any local event,
text of the message is the event description including date and time.
SYSTEM COMMANDS
This manual suits for next models
7
Popular Controllers manuals by other brands

Black Stone
Black Stone BL 983319-0 instruction manual

Samson
Samson TROVIS 5724-8 Mounting and operating instructions

Kessler Crane
Kessler Crane Oracle manual

CentriPro
CentriPro AQUAVAR CPC Installation and operation manual

Disaster Area Designs
Disaster Area Designs DMC-6D quick start guide

SSS Siedle
SSS Siedle TCIP 603-03 Product information