Controlli 4GROUT-WIFI User manual

CONTROLLI S.p.A. - 16010 Sant’Olcese (GE) - Italy
Tel. +39 010 73061 | Fax +39 010 7306870/871
ISTRUZIONI DI MONTAGGIO / MOUNTING INSTRUCTIONS
1aEmissione / 1st Issue 03/2021 1 DIM330
Router Wi-Fi industriale
Industrial Wi-Fi Router 4GROUT-WIFI
APPLICAZIONE ED USO
Integrando 3G, 4G e sicurezza avanzata, con watchdog hardware
incorporato, rilevamento di link, auto-recovery e riavvio automatico,
la serie 4GRout-WiFi fornisce comunicazioni afdabili ad ambienti
non presidiati. La afdabile tecnologia VPN protegge i dati sensibi-
li. 4GRout-WiFi utilizza strumenti di gestione remota con interfaccia
Web.
Questo router è ideale per applicazioni su Internet of Things (IoT) su
larga scala, apparecchiature e sistemi di controllo industriale.
La congurazione del router è descritta con maggiori dettagli nel
manuale utente 4GROUT-WIFI_DMP117e.
FUNZIONALITÀ DEI LED
ALIM. STATO AVVISO ERRORE
DESCRIZIONE
(ROSSO) (VERDE) (GIALLO) (ROSSO)
On Off Off Off In accensione
On Lampeggia On Off Acceso
On Lampeggia On Off In connessione
On Lampeggia Off Off Connesso
On Lampeggia Lampeggia Lampeggia In aggiornamento
On Lampeggia On Lampeggia Reset eseguito
APPLICATION AND USE
Integrating 3G, 4G and advanced security, with embedded hard-
ware watchdog, link detection, auto-recovery and auto-reboot, the
4GRout-WiFi series provides reliable communications to unattended
sites. Reliable VPN technology secures sensitive data. 4GRout-WiFi
uses remote management tools with a web interface.
This router is ideal for large-scale Internet of Things (IoT) applications
including equipment and industrial control systems.
The router conguration is described with more details in the user’s
manual 4GROUT-WIFI_DMP117e.
LEDs FUNCTIONALITIES
POWER STATUS WARN ERROR
DESCRIPTION
(RED) (GREEN) (YELLOW) (RED)
On Off Off Off Powered On
On Blinking On Off Powered On succeed
On Blinking On Off Dialing
On Blinking Off Off Dialing succeed
On Blinking Blinking Blinking Upgrading
On Blinking On Blinking Reset succeed

1aEmissione / 1st Issue 03/2021 2 DIM330
Signal status LED
GREEN
LED 1
GREEN
LED 2
GREEN
LED 3 DESCRIPTION
Off Off Off No signal detected
On Off Off
Signal stregth 1-9 (signal stregth is weak,
please check antenna and the signal
stregth of current location)
On On Off
Signal stregth 10-19 (signal stregth is
basically normal, and equipment can
be used under normal conditions)
On On On Signal stregth 20-31 (signal strong)
WLAN LED
WLAN GREEN LED DESCRIPTION
On Enable WLAN
Off Disable WLAN
Blinking Reset Succeed
INSTALLATION OF DEVICE
Make sure there is 3G/4G network and that there are no shielding on
the site. 220 Vac or 9~26 Vdc must be supplied on site.
• 1 PC
OS: Windows XP, Windows 7, Windows 10
CPU: PII 233 higher
Memory: 32M higher
Hard disk: 6.4 Gb higher
Serial port: At least one
Ethernet port: At least one (10M/100M)
IE version: Above 10.0
Resolution ratio: 640 x 480 px higher
• 1 SIM card
Make sure the SIM is enabled with the data service and the service is
not suspended due to insufcient credit on the SIM.
• Power supply
9-26 Vdc (ripple voltage < 100 mV)
It is possible to use 3GROUT-WIFI-PWR accessory not supplied.
• Fixing
Place 3GRout-WiFi on at level in an environment with a small vibra-
tion frequency.
INSTALLATION OF SIM/UIM CARD
3GRout applies pop-up card holder. Press the yellow button on the
right of the card holder and the card holder will pop up. Then, install
the SIM/UIM card and press the card holder back to the card slot.
ANTENNA INSTALLATION
Slightly rotate the movable part of metal SMA-J interface until it can-
not be rotated (at this time, external thread of antenna cable can-
not be seen). Do not forcibly screw the antenna by holding black
rubber lining.
Segnale di stato dei LED
LED 1
VERDE
LED 2
VERDE
LED 3
VERDE DESCRIZIONE
Off Off Off Nessun segnale rilevato
On Off Off
Potenza del segnale 1-9 (l’intensità del
segnale è debole, si prega di controlla-
re l’antenna e la potenza del segnale
nella posizione corrente)
On On Off
Potenza del segnale 10-19 (la potenza
del segnale è sostanzialmente normale
e l’apparecchiatura può essere utilizza-
ta in condizioni normali)
On On On Potenza del segnale 20-31 (Segnale
forte)
LED WLAN
LED WLAN VERDE DESCRIPTION
On WLAN abilitata
Off WLAN disabilitata
Lampeggia Reset eseguito
INSTALLAZIONE DEL DISPOSITIVO
Assicurati che ci sia una copertura di rete 3G/4G e che non ci siano
schermature sul sito. 220 Vac o 9~26 Vdc devono essere forniti in
loco.
• 1 PC
OS: Windows XP, Windows 7, Windows 10
CPU: Superiore a PII 233
Memoria: Superiore a 32M
Hard disk: Superiore a 6.4 Gb
Porta seriale: Almeno una
Porta Ethernet: Almeno una (10M/100M)
Versione IE: Superiore alla 10.0
Risoluzione: Superiore a 640 x 480 px
• 1 SIM card
Assicurati che la SIM sia abilitata con il servizio dati e il servizio non sia
sospeso a causa di un credito insufciente sulla SIM.
• Alimentazione
9-26 Vdc (tensione di oscillazione < 100 mV)
E’ possibile utilizzare l’accessorio 3GROUT-WIFI-PWR non fornito a cor-
redo.
• Fissaggio
Posizionare 3GRout-WiFi in piano in un ambiente con una piccola
frequenza di vibrazione.
INSTALLAZIONE DELLA SIM/UIM
Premere il pulsante giallo sulla destra del porta SIM per aprirlo. Quin-
di, inserire la scheda SIM/UIM nel cassetto di alloggiamento. Premere
per chiudere il cassetto nello slot della scheda.
INSTALLAZIONE DELL’ANTENNA
Ruotare leggermente la parte mobile dell’interfaccia metallica
SMA-J no alla massima rotazione permessa (in questo momento
non è possibile vedere il lo esterno del cavo dell’antenna). Non
forzare l’antenna nell’avvitarla, tenerla per la gomma nera.

1aEmissione / 1st Issue 03/2021 3 DIM330
INSTALLATION OF PROTECTIVE GROUNDING
The specic steps are shown in below:
1. Remove the grounding screw.
2. Connect the grounding ring of the cabinet’s grounding wire
onto the grounding screw.
3. Tighten the grounding screw up.
CAUTION
To improve the immunity from interference of whole router, the router
must be grounded when using. According to operating environment,
the ground wire should be connected with grounding stud of router.
ACCESSORI
3GROUT-WIFI-PWR 110-220 Vac plug-in power supply, 12 Vdc, 1A
INSTALLATION OF POWER SUPPLY
Upon installation of the antenna, connect the device to 9-26 Vdc
power and see if the Power LED on the panel of the device is on. If
not, please contact technical support of Controlli immediately.
Login Router
Upon installation of hardware, be sure the Ethernet card has been
mounted in the supervisory PC prior to logging in the page of Web
settings of the router.
I. Automatic Acquisition of IP Address (Recommended)
Please set the supervisory computer to “automatic acquisition of IP
address” and “automatic acquisition of DNS server address” (default
conguration of computer system) to let the device automatically
assign IP address for supervisory computer.
II. Set a Static IP Address
Set the IP address of supervisory PC (such as 192.168.2.2) and LAN in-
terface of device in same network segment (initial IP address of LAN
interface of device: 192.168.2.1, subnet mask: 255.255.255.0).
III. Cancel the Proxy Server
If the current supervisory PC uses a proxy server to access the Inter-
net, it is required to cancel the proxy service. The operating steps are
shown below:
1. In the browser window, select “tools>>Internet options”;
2. select “connection” page and click the button of LAN Settings
to enter “LAN Settings” window interface. Please conrm if the
option “Use a Proxy Server for LAN” is checked; if it is checked,
please cancel and click the button <OK>.
IV. Login/Exit Web Settings Page
Open IE or other browser and enter IP address of 4GRout-WiFi, such
as http://192.168.2.1 in address bar (default setting of 4GRout-WiFi).
Upon connection, log in from the login interface as a system admin,
i.e. enter username and password at the login interface (user name
/password default: adm/123456).
INSTALLAZIONE DELLA PROTEZIONE DI MESSA A TERRA
Seguire i seguenti passaggi specici:
1. Rimuovere la vite di messa a terra.
2. Collegare l’anello del cavo di messa a terra dell’armadio alla
vite di messa a terra.
3. Stringere la vite di messa a terra.
ATTENZIONE
Per migliorare l’immunità dalle interferenze dell’intero router, il router
deve essere collegato a terra durante l’utilizzo. Secondo l’ambiente
operativo, il lo di terra deve essere collegato con il perno di messa
a terra del router.
ACCESSORI
3GROUT-WIFI-PWR Alimentatore a spina 110-220 Vac,12 Vdc, 1A
INSTALLAZIONE DELL’ALIMENTATORE
Al momento dell’installazione dell’antenna, collegare il dispositivo a
9-26 Vdc e vericare se il LED di alimentazione sul pannello del di-
spositivo è acceso. In caso contrario, contattare immediatamente il
supporto tecnico di Controlli.
Login Router
Dopo l’installazione dell’hardware, assicurarsi che la scheda Ether-
net sia stata installata nel PC di supervisione prima di accedere alla
pagina delle impostazioni Web del router.
I. Acquisizione automatica dell’indirizzo IP (consigliato)
Impostare il computer di supervisione su “acquisizione automatica
dell’indirizzo IP” e “acquisizione automatica dell’indirizzo del server
DNS” (congurazione predenita di sistema) per consentire al dispo-
sitivo di assegnare automaticamente l’indirizzo IP per il computer di
supervisione.
II. Imposta un indirizzo IP statico
Impostare l’indirizzo IP del PC di supervisione (come 192.168.2.2) e
l’interfaccia LAN del dispositivo nello stesso segmento di rete (indiriz-
zo IP iniziale dell’interfaccia LAN del dispositivo: 192.168.2.1, subnet
mask: 255.255.255.0).
III. Annulla il server proxy
Se il PC di supervisione corrente utilizza un server proxy per accedere
a Internet, è necessario annullare il servizio proxy. I passaggi operativi
sono mostrati di seguito:
1. Nella nestra del browser, selezionare “Strumenti >> Opzioni In-
ternet”;
2. selezionare la pagina “Connessione” e fare clic sul pulsante
Impostazioni LAN per accedere all’interfaccia della nestra
“Impostazioni LAN”. Si prega di confermare se l’opzione “Use
a Proxy Server for LAN” è spuntata; se è selezionato, si prega di
annullare e fare clic sul pulsante <OK>.
IV. Login/Esci dalla pagina delle impostazioni web
Apri IE o un altro browser e inserisci l’indirizzo IP di 4GRout-WiFi, come
http://192.168.2.1 nella barra degli indirizzi (impostazione predenita
di 4GRout-WiFi). Al momento della connessione, accedere dall’inter-
faccia di accesso come amministratore di sistema, ad esempio im-
mettere nome utente e password nell’interfaccia di accesso (nome
utente / password predeniti: adm/123456).

Le caratteristiche contenute in questa pubblicazione possono essere modifi cate senza preavviso
The performances stated in this sheet can be modifi ed without any prior notice
1aEmissione / 1st Issue 03/2021 4 DIM330
DIMENSIONI / DIMENSIONS [mm]
Montaggio su guida DIN / DIN-Rail Mounting
Il dispositivo contiene componenti elettrici ed elettronici e non può essere smaltito con i riuti domestici. Vanno rispettate le normative locali sullo smal-
timento.
The device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and
requirements must be observed.
Other Controlli Wireless Router manuals
Popular Wireless Router manuals by other brands

Benington Networks
Benington Networks AirCube user guide

TP-Link
TP-Link TL-WR1043ND - Ultimate Wireless N Gigabit... user guide

NetComm
NetComm NB16WV quick start guide

Edimax
Edimax BR-6478AC Quick installation guide

DIGITAL YACHT
DIGITAL YACHT iNavConnect Installation and instruction manual

BEC
BEC RidgeWave 6900 quick start guide

Velleman
Velleman VMA205 user manual

TRENDnet
TRENDnet AC750 Quick installation guide

Banana Pi
Banana Pi BPI-R1 user manual

Buffalo
Buffalo AirStation Turbo G WHR-HP-G54 user manual

Belkin
Belkin F5D8231-4 - N1 Wireless Router Operational Principle

Linksys
Linksys WRT310N - Wireless-N Gigabit Router Wireless user guide