CoolBot CoolBot Pro User manual

CoolBot Factory Reset
Not Applicable to 2G Model (CoolBot with cables on top and side)
CoolBot Pro
From the CoolBot Pro Controller
1. On the CoolBot, press the left arrow button until the Program light is solidly lit. You will see the
firmware version on the display (7.8, 7.9, etc.).
2. Press the Checkmark button five times slowly, until you see “P1” on the display.
3. Press the Left Arrow a few times to get to the reset option you want:
○P1: resets all settings (Same as “Fr”)
■Full factory reset of CoolBot and Jumper IF the Jumper is connected.
■Full factory reset of the CoolBot only, if the Jumper is disconnected.
○ES: escapes from this menu and returns to normal operation
○CJ: clears the Jumper’s (Wi-Fi radio) settings only. The Jumper HAS to be connected to the CoolBot
Pro.
○CE: Wi-Fi Mode disabled: Y=Not using Wi-Fi, N=Using Wi-Fi (See NOTE below)
○CS: clears the CoolBot’s settings to defaults but keeps the Wi-Fi settings the same.
○Fr: resets all settings (Same as “P1”)
■Full factory reset of CoolBot and Jumper IF the Jumper is connected.
■Full factory reset of the CoolBot (ONLY), if Jumper is disconnected.
4. Press Checkmark to select that reset option.
5. You will see a blinking “n” for “no”. Press one of the arrow keys to change it to “y” for “yes.”
6. Press Checkmark. The CoolBot will reset the selected settings.
7. If you chose P1, CJ, or Fr with the Jumper connected to the CoolBot Pro, the CoolBot will switch to its
Wi-Fi Configuration mode. You should see the code “E0” on the display. This means it’s ready to
reconfigure Wi-Fi.
8. The CoolBot set temp has been reset to factory setting of 42F, change it to your desired room temp.
(continue on page 2)
© 2018-12A Store It Cold, LLC

NOTE
IMPORTANT! If you are not using Wi-Fi and you have an EE showing on the display follow these steps:
1. Unplug the CoolBot Pro from the power supply
2. Disconnect the Jumper from the CoolBot – disconnect the Data Cable (if it was connected)
3. Plug your CoolBot Pro back in. You will see EE
4. Follow steps 1, 2, and 3 for rebooting the CoolBot Pro to get to the main program menu options
5. Scroll (with the arrows) to the CE option and select (checkmark) then choose (with the arrows): Y
6. Press Checkmark. Your CoolBot Pro should stop blinking and revert back to show the Room
Temperature (It is ready to use in the “No Wi-Fi Mode”)
From the app
DEVICES TAB - Hardware Setup Menu
Clicking on the Hardware Setup Expandable Menu gives you choices for resetting your CoolBot Pro,
downloading latest firmware for the CoolBot Pro controller, and reconfigure your Wi-Fi connection.
1. Factory Reset – Use this option to reset your CoolBot (ONLY) to Factory Settings while keeping your Wi-Fi
configuration. This is the same as “CS” from the CoolBot Controller program Menu.
2. Update Firmware – This option downloads the latest Firmware version to your CoolBot JUMPER. It is not
really a Reboot but an update for Firmware. The tab will become gray and the Status Icon will indicate
“updating” in yellow until done.
3. Reconfigure Wi-Fi – This option will walk you step by step through the entire Wi-Fi configuration process
(just like the first time you set up your CoolBot Pro to connect to your Wi-Fi Network). A Jumper reset (“CJ” or
“Fr”) will be necessary (see From the CoolBot Pro Controller section above) so the Jumper resets and the
CoolBot displays “E0” meaning that it is ready for a Wi-Fi set up again.
© 2018-12A Store It Cold, LLC

CoolBot
6.5 or 6.4 version
1. Tap the right arrow to move the cursor light over to the “program” mode. Double check that it says
either “6.4 or 6.5” in the display
2. Tap the checkmark (center button) 5 times. You’ll see P-1 in the display
3. Tap the checkmark once to select. You will see a lowercase N (“n”)
4. Tap the right arrow once to change to y. (for no and yes)
5. Tap the check mark once to select and wait 20 seconds without touching any buttons.
6. The CoolBot set temp has been reset to factory setting of 42F, change it to your desired room temp.
6.3 version
1. Tap the right arrow to move the cursor light over to the program mode. Make sure it reads “6.3” in the
display.
2. Tap the check mark 3 times. You will see FC in the display.
3. Tap the left arrow once. You will see rE in the display (for reset) (lowercase r, upper case E)
4. Tap the checkmark once. You will see “no” in the display
5. Tap the right arrow once. You will see 60 in the display.
6. Tap the checkmark once and wait 20 seconds of the CoolBot to completely reset itself.
7. The CoolBot set temp has been reset to factory setting of 42F, change it to your desired room temp.
6.1 version
1. Tap the right arrow to move the cursor light over to the program mode. Double check that it says “6.1”
in the display.
2. Tap the checkmark once. You will see FC in the display.
3. Tap the left arrow once. You will see rE in the display (for reset) (lowercase r, upper case E)
4. Tap the checkmark once. You will see “no” in the display
5. Tap the right arrow once. You will see 60 in the display.
6. Tap the checkmark once and wait 20 seconds of the CoolBot to completely reset itself.
7. The CoolBot set temp has been reset to factory setting of 42F, change it to your desired room temp.
© 2018-12A Store It Cold, LLC
This manual suits for next models
1
Table of contents
Popular Controllers manuals by other brands

Extron electronics
Extron electronics FPC 6000 Setup guide

URC
URC MRX-20 owner's manual

Radial Engineering
Radial Engineering MC3 user guide

eqss
eqss OverWatch 6253 Install manual

ADVATEK LIGHTING
ADVATEK LIGHTING PixLite 16 Plug And Play Mk2 user manual

Daikin
Daikin homecontrols EKRSIBDI1V3 Installation and operation manual