Cooper Lighting Solutions WaveLinx Pro User manual

Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product must be
performed by a qualied electrician. This product must be installed in accordance with the applicable installation code
by a person familiar with the construction and operation of the product and hazards involved.
Before installing or performing any service, the power MUST be turned OFF at the branch circuit breaker. According to NEC
240-83(d), if the branch is used as the main switch for a fluorescent lighting circuit, the circuit breaker should be marked
with “SWD”. All installations should be in compliance with the National Electric Code and all state and local codes.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any maintenance.
Disconnect power at fuse or circuit breaker.
Risk of Burn- Disconnect power and allow product to cool before handling or servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise
from the improper, careless, or negligent installation, handling or use of this product.
NOTICE: Product may become damaged and/or unstable if not installed properly.
Note: Specications and dimensions subject to change without notice.
ATTENTION Receiving Department: Note actual product description of any shortage or noticeable damage on delivery receipt.
File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be led within 15 days of delivery.
All damaged material, complete with original packing must be retained.
NOTICE: All new wiring must be fully veried before applying power.
NOTICE: Designed for outdoor installation and use. Wet location rated.
Wireless Area Controller (WAC2-POE)
with Outdoor Rated Enclosure
IMPORTANT: Read carefully before installing product. Retain for future reference.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.
WARNING
WaveLinx ProInstallation Instructions

SAVE THESE INSTRUCTIONS
This installation instruction is for the Wireless Area Controller with Outdoor Enclosure (WAC2-POE-OUT-EN) which enables user control
of the WaveLinx Pro wireless controlled lighting (WCL) system and devices via local control or through the WaveLinx Mobile application.
The purpose of this document is to provide detailed instructions for installation and basic troubleshooting.
This document covers installation of the following product:
• WAC2-POE-OUT-EN Wireless Area Controller with Outdoor Enclosure.
ote: N WAC2-POE-OUT-EN includes PoE injector internal to the enclosure and requires 120VAC 50/60Hz wiring via 3/4” conduit.
WaveLinx Pro connected lighting (WCL) system Architecture
Stand Alone WAC installation (outdoor specific)
WaveLinx Pro
Wireless Area
Controller with
Outdoor Enclosure
(WAC2-POE-OUT-EN)
120VAC 50/60Hz "AC" input
WaveLinx Pro Mobile App
used for system setup
and personal control
Wi-Fi Signal
IEEE 802.15.4
KEY
Area or Room
(49 + 1 construction area)
Integrated
Outdoor
WaveLinx Pro wireless controlled devices
(up to 200 devices per WAC2 - 150 devices best practice) - see Note
Note:
Performance based on second generation
WaveLinx Pro Wireless Area Controller (WAC2)
Room Based
Occupancy Sensor
120-347V 20A
Dimming Switchpacks
Wireless Area Controller (WAC2-POE) with Outdoor Rated EnclosureWaveLinx Pro
IB50301921 page 2
June 2022
www.cooperlighting.com

Enterprise installation
Area or Room
(49 + 1 construction area)
Area or Room
(49 + 1 construction area)
Wi-Fi Signal
IEEE 802.15.4
KEY
Building LAN
Touchscreen
WaveLinx Pro Mobile App used for
system setup and personal control
PoE
Power
Trellix Core
BACnet/IP
Public (REST) API
Third Party system
(hardware provided
by others) BACnet Router1
(hardware provided
by others)
Desktop/Laptop
with web browser
(hardware provided
by user)
Note:
Trellix Core Pro shown in this illustration.
Trellix Core hardware can be either Pro,
Enterprise or Virtual.
1 BACnet Router only required if
Trellix Core and third party BACnet client
are on differenet subnets.
Area or Room
(49 + 1 construction area)
Integrated
Ambient
Integrated
Outdoor
Room Based
Occupancy Sensor
WaveLinx Pro wireless controlled devices
(up to 200 devices per WAC2 - 150 devices best practice) - see Note
Controlled
Receptacle
Scene
Wallstation
120-347V 20A
Dimming Switchpacks
WaveLinx Pro
Wireless Area
Controller
WaveLinx Pro
Wireless Area
Controller inside
Outdoor Enclosure
Overview
The Wireless Area Controller (WAC) in an Outdoor Enclosure is the main component of the WaveLinx Pro wireless connected lighting
(WCL) system. WaveLinx Pro eliminates the cost and complexity of typical wireless control system commissioning while providing
a flexible and reconfigurable topology for on the fly space adjustments. The WaveLinx system meets modern code and utility
requirements, delivers energy and cost savings, while enabling buildings to become smart buildings.
The WAC coordinates between the WaveLinx Pro Mobile App and various WaveLinx Pro devices to create communications and a
building ecosystem that provides out of the box functionality and leverages our patent pending automatic code commissioning
features. Using standards-based wireless mesh compliant topology the WAC communicates to various WCL standards-based devices
to provide area, lighting zone configuration, monitoring, and control.
The WAC provides centralized coordination of multiple areas for partial ON/partial OFF scheduling, demand response (Trellix
application required), lighting, occupancy and daylight settings and scene control. A single WAC can be connected to the building
LAN to coordinate up to 49 user-defined areas and 1 construction area, or multiple WAC’s can exist on a building LAN to scale the
system to hundreds of areas all accessible for setup, configuration and control through the WaveLinx Pro Mobile App.
WaveLinx Pro wireless connected system components
• Wireless Area Controller (gateway)
• WaveLinx Pro Mobile App (commissioning and user personal control)
• WaveLinx Pro Wallstation - wired or battery (manual lighting and scene control)
• WaveLinx Pro Touchscreen
• Wireless INstinct Sensor (fixture integrated occupancy sensor, ambient light sensor and control)
• WaveLinx Pro Relay Switchpacks with 0-10V
• WaveLinx Pro Receptacles (wall mounted power outlet)
• WaveLinx Pro Room Based Sensor (ceiling mounted PIR occupancy sensor)
Wireless Area Controller (WAC2-POE) with Outdoor Rated Enclosure WaveLinx Pro
IB50301921 page 3
June 2022
www.cooperlighting.com

Outdoor Enclosure of the WAC
15.75"
[400mm]
11.81"
[300mm]
5.90"
[150mm]
1.18"
[30mm]
11.81"
[300mm]
9.33"
[228mm]
13.19"
[335mm]
0.98"
[25mm]
9.33"
[228mm]
15.75"
[400mm] 12.80"
[325mm]
M5 Threaded
Insert (4x)
Inside view of body
with cover removed
11.81"
[300mm]
1.18"
[30mm]
0.44"
[11mm] 0.33"
[8mm]
0.13"
[3mm]
0.98"
[25mm]
ø0.17
[ø4mm]
(40x)
Where to Mount the WAC
• Should be installed vertically on the wall as high as possible in the center of the space it will be controlling.
Do not install on ceiling.
• The WAC should be located so it has a good line-of-sight (300ft MAX / 150ft best practice) with its communicating devices.
• Wired Ethernet connection within 300ft (91m) of building LAN connection point.
• At least 10ft (3m) away from the building WiFi access points.
• At least 15ft (5m) away from metal structures.
Where NOT to Mount the WAC
• Inside a metal enclosure or near large metal objects or walls.
• Do not mount In direct sunlight.
• Do not mount inside electrical closet.
Wireless Area Controller (WAC2-POE) with Outdoor Rated EnclosureWaveLinx Pro
IB50301921 page 4
June 2022
www.cooperlighting.com

Installation
The Wireless Area Controller (WAC) must be installed in accordance with all local, state, and national electrical codes and
requirements.
Environment:
• Operating temperature: -22°F to 104°F (-30°C to 40°C)
• Storage temperature: -22° F to 185° F (-30°C to 85°C)
• Relative humidity operating: 5% to 90% RH (non-condensing)
• For outdoor use
Mounting: Exterior wall locations where NOT exposed to direct sunlight
1. Before mounting the WAC in its final location: Install WaveLinx Pro wireless devices and verify out-of-the-box functionality.
2. Mount the Wireless Area Controller (WAC).
• Ensure the WAC is roughly central to the devices with which it is communicating
(line of sight range: 300ft MAX / 150ft best practice).
• Review the “Where to Mount” section of this installation instruction.
• The outdoor enclosure can be installed on a wall with the included mounting hardware.
• Metal and concrete surfaces will affect wireless performance. Please keep the WAC in an Outdoor Enclosure within clear
line of site of attached devices.
9.92"
[252mm]
16.3"
[414mm]
Mounting
M5 Threaded
Insert (4x)
0.15" [4mm]
DIA
Front view
(door hidden for clarity)
Surge
protector
Ethernet
connection
3/4" Conduit
connection
AC to DC
power
supply
Thermostat
Heater
Weeping
holes
WAC
power
supply
WAC
Wireless Area Controller (WAC2-POE) with Outdoor Rated Enclosure WaveLinx Pro
IB50301921 page 5
June 2022
www.cooperlighting.com

3. Power the Wireless Area Controller (WAC).
• This product requires 120VAC only for power. The Wireless Area Controller contained inside is a PoE powered device with a
120VAC PoE injector pre-wired for installer convenience.
4. Input power connection
• The entry point for the supply wiring is via the ¾” conduit on the bottom of the chassis.
• Use a suitable conduit to feed the source wiring safely into the chassis.
• See the diagram below for connection details.
• Please consult the image below for details about the maximum permissible supply wire gauges.
• Please do not touch the heating unit or let any wiring near it, as the surface may be very hot.
Input power
Input power:
120VAC 50/60HZ
via ¾” conduit
WAGO detail
L / N / GND
connections
Wiring Information:
Strip wire: 1/2”-5/8”
Wire size: 12 AWG
Solid/Stranded copper only
Ground
Neutral
Line In
5. For network communications, a wired Ethernet connection is required. Connect Ethernet cables appropriate for the application up
to a MAX distance of 300ft (91m) to building LAN.
Ethernet external port
external port
Building LAN connection
Building LAN
connection
6. Connect to building network.
7. Create Construction Group - see section on construction grouping.
8. Finalize programing using the WaveLinx Pro Mobile App.
• See WaveLinx Pro manual for more information.
9. Document the IEEE address found on the bottom of the WAC inside the enclosure on the site floor plans.
Wireless Area Controller (WAC2-POE) with Outdoor Rated EnclosureWaveLinx Pro
IB50301921 page 6
June 2022
www.cooperlighting.com

WaveLinx Pro design best practices
Design Consideration Best Practice Maximum Capability
WCL devices per WAC2 150 200
User-defined areas per WAC2 49 49
Construction areas per WAC2 1 1
Zones per Area 3 Up to 200 per WAC
Total Zones per WAC2 200 200
Scenes per Area 16 16
WAC range (outdoor WCL devices) 150ft (45m) LOS1300ft (91m) LOS2
WAC range (outdoor WCL devices) See sensor spec sheets
Device hops beyond WAC (indoor / outdoor) 4 / 10 5 / 10
ote: N
1 Considering two (2) interior walls of standard construction
2 Considering no LOS obstructions (walls, columns, etc.)
Wireless Area Controller LED Indicators
The LED indicators can be used for diagnostics and troubleshooting diagnostics of the WaveLinx Pro system.
The table below gives you more information.
4.69"
[119mm]
4.69"
[119mm] 1.97"
[50mm]
4.80"
[122mm]
LED Color On Off Blink Fast Blink
WAN Green Connection to
OpenADR or 3rd
party
Normal Communications
from 3rd party
LAN Green Connected to
building LAN and
received IP address
No connection or
IP address from
building LAN
Communications
from LAN.
During internal
webpage setup
WiFi Blue Connected to
building LAN and
received IP address
No connection or
IP address from
building LAN
Communications
from LAN.
During internal
webpage setup
When login UN/PW
are reset
PAN Blue Future functionality Future functionality Future functionality Future functionality
802.15.4 Blue WaveLinx Pro
network is formed No WaveLinx Pro
devices are paired During Construction
Grouping and
WaveLinx Pro
Communications
When WAC is set to
Factory Defaults
Wireless Area Controller (WAC2-POE) with Outdoor Rated Enclosure WaveLinx Pro
IB50301921 page 7
June 2022
www.cooperlighting.com

Wireless Area Controller in an Outdoor Enclosure interior and exterior views
1. Ethernet Port for connection to building LAN for communications.
2. RESET Button
• Resets the Wireless Area Controller, does not impact settings
3. PAIR Button
• Construction Group
• Removing devices
• Reset login UN/PW
• Factory Defaults
2
1
3
Wireless Area Controller (WAC2-POE) with Outdoor Rated EnclosureWaveLinx Pro
IB50301921 page 8
June 2022
www.cooperlighting.com

PAIR button functionality
Using the PAIR button on the Wireless Area Controller allows you to add
or remove devices to the WaveLinx system, reset building network login
information and restore factory defaults.
The WaveLinx Wireless Area Controller 2 has two pushbuttons that allow for
several administrative functions. These functions should be used with caution!
Function Button Press Length WAC LED feedback Device outcome
Enter Pairing Mode Pair Press and
release (1
second)
802.15.4 and LAN LEDs flash Paired devices will exhibit paired
behavior described in the device
reference sheets. Unpaired devices can
pair with the Wireless Area Controller if
they are in pairing mode.
Exit Pairing Mode
(if pairing mode is
still active)
Pair Press and
release
(1 second)
802.15.4 LED ON steady
LAN LED returns to OFF or ON
dependent on connection to Ethernet
and configuration.
Paired devices will start operation within
the construction grouping. Lighting
still in the default construction area
will turn on to a 100% level or operate
from paired wallstations and occupancy
sensor controls.
Remove Unassigned
Devices Pair Press and hold
for 4 seconds
recommended
(>2 sec. to
<=10 sec.)
802.15.4 LED flashes rapidly (.25 sec
ON/.25 sec OFF) when the button is held
for the allotted time and continues until
the devices have been commanded to
leave the network.
802.15.4 LED will turn ON steady once
there are no devices remaining in the
Construction Area.
Devices still in the default construction
area will leave the WaveLinx network.
Reboot/Soft Reset Reset
(Inset Button)
Press and
release
(1 second)
All LEDs turn OFF after button release.
As device reboots, LEDs may turn ON
and OFF during reboot.
Once reboot completes (approximately
1 minute), Power/Health LED and
802.15.4 LED should be ON steady.
Other LEDs may also be on dependent
on WAC2 configuration.
Devices will remain in previous
commanded state during reboot, rejoin
the WAC2 upon reboot completion and
continue their normal behavior.
Programmed settings are retained
during a reboot.
Authentication and
Wi-Fi Configuration
Reset
Reset
(Inset Button)
Press and hold
for 4 seconds
recommended
(>2 sec. to
<= 5 sec.)
Wi-Fi LED flashes rapidly (.25 sec
ON/.75 sec OFF) when the button is held
for the allotted time.
Wi-Fi LED turns OFF for 1 second when
button is released and then blinks .5sec
ON/ .5 sec OFF for 5 seconds while the
WAC2 clears the settings.
Wi-Fi LED turns ON steady when
process is complete.
No effect on devices. The following
data will be cleared and reset to factory
defaults:
• Wi-Fi Access Point settings
• Wi-Fi Client settings
Reset factory
defaults
Reset (Inset
Button) Press and hold
for 8 seconds
recommended
(>5 sec. to
<=10 sec.)
The Wi-Fi LED starts flashing after 2
seconds.
All of the LEDs except for BT will flash
(.5 seconds ON/ .5 seconds OFF) when
the button is held for the allotted time.
The Power/Health LED will turn OFF
when the button is released, and other
LEDs will stop flashing.
After a short delay, additional LEDs may
turn OFF and the WAC will reboot.
Once reboot completes (approximately
1 minute), Power/Health LED and
802.15.4 LED, and the Wi-Fi LED should
be ON steady. Other LEDs may also be
on dependent on connections.
All programming will be cleared for the
Wireless Area Controller and reset to
factory defaults including:
• Removing all 802.15.4 device pairing
• All user accounts
• Clearing user-uploaded custom
certificates
• Network configuration including:
• Wi-Fi client settings
• Wi-Fi access point settings
• Ethernet settings
• Clearing all programming including
area and zone designations
• Resetting WAC name to default
Wireless Area Controller (WAC2-POE) with Outdoor Rated Enclosure WaveLinx Pro
IB50301921 page 9
June 2022
www.cooperlighting.com

Construction Grouping
With the patent-pending Construction Grouping mode, installers can now complete a quick system start-up to confirm that the devices
have been installed correctly, instead of waiting for factory-trained technicians to get the lights on a project in working order. Installers
follow a simple process to pair the wireless devices and assign addresses with the appropriate WAC and initiate occupancy-based
lighting control functionality. This saves lighting energy during the construction phase of the project by ensuring that the lights are
turned off when the area is unoccupied.
1. Locate the Wireless Area Controllers on the site plan
2. Identify which WaveLinx Pro devices should be in range and assigned to each Wireless Area Controller
3. Identify the circuit breakers that control WaveLinx Pro devices that are intended to be assigned to the Wireless Area Controller by
performing Construction Grouping
4. Cycle power to each circuit breaker for the identified WaveLinx Pro devices
• WaveLinx devices will search for the Wireless Area Controller for 30 minutes after each power cycle, unless they have already
paired with a WAC
5. On the Wireless Area Controller press and release the “PAIR” button to enter Construction Grouping Mode
• The 802.15.4 wireless network LED on the WAC will blink while in Construction Group mode
• The WAC will leave Construction Grouping after 30 minutes
6. WaveLinx Pro devices will start communicating to the Wireless Area Controller
7. As devices pair with the Wireless Area Controller creating the Construction Group, they will illustrate the following default behavior.
If a device has already been added to an area, it will not be affected.
• Luminaires with integrated sensors
• Luminaire dims to 10%
• Relay with 0-10V
• Connected luminaires will dim to 10% and receptacles will turn OFF for 5 minutes
• The controlled outlet will turn OFF for 5 minutes
• Wallstation
• All LEDs blink
• All wallstations in the default area control all luminaires together
8. After all WaveLinx Pro devices have joined the Construction Group and illustrated the above behavior.
• Press the “PAIR” button on the WAC a second time to leave the Construction Grouping mode,
• The WAC will leave Construction Grouping automatically after 30 minutes if the “PAIR” button is not pressed a second time.
• The IEEE 802.15.4 wireless network LED on the WAC will be ON
9. After leaving the Construction Group mode the WaveLinx devices will behave in the following manner.
• Luminaires with integrated sensors
• Luminaire dims to 75%
• All luminaires turn ON when the first occupancy sensor senses motion
• All luminaires turn OFF when the last occupancy sensor times out unoccupied
• All wallstations in the default area control all luminaires together.
• All integrated sensors, Tile Mount and Ceiling sensors create an occupancy group
• All luminaires turn ON when the first occupancy sensor senses motion
• All luminaires turn OFF when the last occupancy sensor times out unoccupied
• All wallstations in the default area control all luminaires together.
• All integrated sensors, Tile Mount and Ceiling sensors create an occupancy group
Wireless Area Controller (WAC2-POE) with Outdoor Rated EnclosureWaveLinx Pro
IB50301921 page 10
June 2022
www.cooperlighting.com

• Relay with 0-10V
• Connected luminaires dim to 75%
• All wallstations in the default area control all luminaires together.
• All luminaires turn ON when the first occupancy sensor senses motion
• All luminaires turn OFF when the last occupancy sensor times out unoccupied
• Relay turns ON/OFF based on occupancy
• Receptacle
• The controlled outlet will turn ON/OFF based on occupancy
• Wallstation
• All wallstations in the default area will control all luminaires in the default area based on out-of-the-box scene
definitions.
Connecting the Wireless Area Controller to the Building LAN
1. Wired Connection - Building LAN connection
• Connect the WAC to the building network.
• Physical connection to the building LAN and receiving an IP address will automatically disable the wireless connection method
• WAC’s will automatically receive a DHCP IP address when connected to the building LAN
• WAC device name will be: Cooper Lighting Solutions--xxxxxxxxxxxx on the building network
• (where **** are all twelve characters of the unit MAC address found on the label at the bottom front of the WAC plus 1)
• Using the WAC internal web page,
• Change the default name of the WAC
• Statically assigning the IP address of the WAC
2. Wireless Connection - Building Wireless connection
• WAC device name will be: Cooper Lighting Solutions--xxxxxxxxxxxx
• (where **** are all twelve characters of the unit MAC address found on the label at the bottom front of the WAC plus 1)
• Using the WAC internal web page,
• Enter the building wireless login credentials.
• Building wireless login credentials are secured in the WAC by secure web pages and encryption during storage.
• Change the default name of the WAC
• Statically assigning the IP address of the WAC
Wireless Area Controller (WAC2-POE) with Outdoor Rated Enclosure WaveLinx Pro
IB50301921 page 11
June 2022
www.cooperlighting.com

FCC Statement
• This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Note: The grantee is not responsible for any changes or modifications not
expressly approved by the party responsible for compliance. Such modifications
could void the user’s authority to operate the equipment.
Note: The equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off an on, the user
is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment must be installed and operated
in accordance with provided instructions and the antenna(s) used for this
transmitter must be installed to provide a separation distance of at least 20 cm
from all persons.
Declaración de la FCC
• Este dispositivo cumple con la Parte 15 de las Normas de la FCC.
Su funcionamiento está sujeto a las siguientes dos condiciones:
(1) Este dispositivo no debe causar interferencia dañina.
(2) Este dispositivo debe aceptar cualquier interferencia recibida,
incluidas las interferencias que puedan causar un funcionamiento no
deseado.
Nota: El concesionario no es responsable por los cambios o modificaciones que
no estén expresamente aprobados por la parte responsable de su cumplimiento.
Tales modificaciones podrían anular la autoridad del usuario para operar el
equipo.
Nota: El equipo ha sido probado y cumple con los límites para un dispositivo
digital de Clase B, de conformidad con la parte 15 de las Normas de la FCC.
Estos límites están diseñados para proporcionar una protección razonable
contra las interferencias dañinas en una instalación residencial. Este equipo
genera usos y puede emitir energía de radiofrecuencia y si no se instala y
utiliza de acuerdo con las instrucciones, puede causar interferencia dañina
en las comunicaciones de radio. Sin embargo, no se puede garantizar que
dicha interferencia no ocurra en una instalación determinada. Si este equipo
causa interferencia dañina en la recepción de radio o televisión, lo que puede
determinarse apagando y encendiendo el equipo, se recomienda al usuario que
intente corregir la interferencia mediante una o más de las siguientes medidas:
• Reorientar o reubicar la antena receptora.
• Aumentar la separación entre el equipo y el receptor.
• Conectar el equipo a una toma de corriente en un circuito
diferente al que está conectado el receptor
• Consultar con el distribuidor o con un técnico de radio/TV
experimentado para obtener ayuda.
Este equipo cumple con los límites de exposición a la radiación de la FCC
establecidos para un entorno no controlado. Este equipo debe instalarse y
operarse de acuerdo con las instrucciones proporcionadas y la(s) antena(s)
utilizada(s) para este transmisor deben instalarse para proporcionar una
distancia de separación de al menos 20 cm de todas las personas.
ISED RSS
This device complies with Industry Canada’s licence-exempt RSSs. Operation is
subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
CAN ICES-003 (B)/NMB-003(B)
ISED RSS
Le présent appareil est conforme aux CNR d’Industrie Canada applicables
aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes :
1) l’appareil ne doit pas produire de brouillage;
2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
CAN ICES-003 (B)/NMB-003(B)
Wireless Area Controller (WAC2-POE) with Outdoor Rated Enclosure WaveLinx Pro
IB50301921 page 12
June 2022
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
For service or technical assistance:
1-800-553-3879
Canada Sales
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-501-3000
F: 905-501-3172
© 2022 Cooper Lighting Solutions
All Rights Reserved.
Product availability, specifications,
and compliances are subject to
change without notice.
FCC Statement
Warranties and Limitation of Liability
Please refer to www.cooperlighting.com for our terms and conditions.
Garanties et limitation de responsabilité
Veuillez consulter le site www.cooperlighting.com pour obtenir les conditions générales.
Garantías y Limitación de Responsabilidad
Visite www.cooperlighting.com para conocer nuestros términos y condiciones.

Risque d’incendie, de décharge électrique, de coupure ou d’autres risques – L’installation et l’entretien de ce produit
doivent être effectués par un électricien qualié. Ce produit doit être installé conformément aux règles d’installation
en vigueur par une personne familière avec la construction et le fonctionnement du produit ainsi qu’avec les risques
inhérents.
“L’alimentation électrique doit être HORS TENSION depuis le disjoncteur de circuit de dérivation avant de procéder
à l’installation ou tout entretien. Selon la norme240-83(d) de la NEC, si un disjoncteur de circuit de dérivation est utilisé
comme interrupteur principal pour un circuit d’éclairage uorescent, ce disjoncteur doit comporter la marque «SWD».
Toutes les installations doivent être conformes au Code national de l’électricité, ainsi qu’à tous les codes nationaux et
locaux.”
Risque d’incendie et de décharge électrique – Assurez-vous que l’alimentation électrique est HORS TENSION avant de
commencer l’installation ou de tenter d’en faire l’entretien. Mettez l’alimentation électrique hors tension au niveau du
fusible ou du disjoncteur. Toutes les installations doivent être conformes au Code national de l’électricité, ainsi qu’à tous
les codes nationaux et locaux.
Risque d’incendie et de décharge électrique – Assurez-vous que l’alimentation électrique est HORS TENSION avant de
commencer l’installation ou de tenter d’en faire l’entretien. Mettez l’alimentation électrique hors tension depuis le fusible
ou le disjoncteur.
Risque de blessures – À cause des arêtes tranchantes, manipulez ce produit avec précaution.
EXONÉRATION DE RESPONSABILITÉ: Cooper Lighting Solutions n’assume aucune responsabilité pour les dommages ou pertes de
quelque nature que ce soit pouvant découler d’une installation, d’une manipulation ou d’une utilisation inappropriée, imprudente ou
négligente de ce produit.
AVIS: Ce produit peut s’endommager ou devenir instable s’il n’est pas installé correctement.
Remarque: Les caractéristiques techniques et les dimensions peuvent changer sans préavis.
ATTENTION Service de la réception: Veuillez fournir une description de tout élément manquant ou de tout dommage constaté au
bordereau de réception. Soumettez une réclamation de transporteur public (chargement partiel) directement auprès du transporteur.
Les demandes pour les dommages cachés doivent être présentées dans les 15 jours suivants la livraison. Tout matériel endommagé
doit être conservé avec tout l’emballage d’origine.
AVIS: Il faut entièrement vérifier tous les nouveaux câblages avant la mise sous tension.
AVIS: Produit conçu pour une installation et une utilisation à l’extérieur. Homologué pour les endroits mouillés.
AVERTISSEMENT
Contrôleur de zone sans l (WAC2-POE)
avec boîtier pour l’extérieur
IMPORTANT: Lire attentivement avant d’installer le produit. À conserver pour consultation ultérieure.
La désobéissance aux instructions suivantes représente un risque de blessures (y compris la mort) et de dommages matériels.
WaveLinx ProInstructions d’installation

CONSERVEZ CES DIRECTIVES
Ces instructions d’installation concernent le contrôleur de zone sans fil avec boîtier pour l’extérieur (WAC2-POE-OUT-EN) qui permet à
l’utilisateur de contrôler le système compatible avec le système d’éclairage sans fil WaveLinx Pro au moyen d’une commande locale ou
de l’application mobile WaveLinx.
Ce document a pour but de fournir des instructions détaillées pour l’installation et le dépannage de base du système.
Ce document porte sur l’installation des produits suivants.
• WAC2-POE-OUT-EN Contrôleur de zone sans fil avec enceinte pour l’extérieur.
emarque: RLe boîtier du contrôleur WAC2-POE-OUT-EN comprend un injecteur PoE interne et nécessite un câblage de 120V c.a.
50/60Hz par un conduit de 1,9cm (3/4po).
Architecture du système d’éclairage connecté WaveLinx Pro
Installation du contrôleur de zone sans fil autonome (spécifique à l’extérieur)
Contrôleur de zone
sans fil
WaveLinx Pro avec
boîtier pour l’extérieur
(WAC2-POE-OUT-EN)
Entrée de 120V c.a 50/60Hz
Application mobile utilisée
pour l’installationdu système et le
contrôle personnel Appareils
Éclairage extérieur
intégré
Poste mural
de la scène
Bloc-commutateur de gradation
de 120-347V et 20A
Signal Wi-Fi
Protocole
IEEE 802.15.4
LÉGENDE
Zone ou pièce
(49 + 1 zone de construction)
Appareils compatibles avec le système d’éclairage sans fil WaveLinx Pro
(jusqu’à 200 par WAC2 - 150 appareils) – Voir la remarque
Remarque:
Le rendement est basé sur le contrôleur de zone sans fil
WaveLinx Pro (WAC2) de deuxième génération.
Contrôleur de zone sans l (WAC2-POE) avec boîtier pour l’extérieurWaveLinx Pro
IB50301921 page 14
Juin 2022
www.cooperlighting.com

Installation en entreprise
Zone ou pièce
(49 + 1 zone de construction)
Zone ou pièce
(49 + 1 zone de construction)
Signal Wi-Fi
Protocole
IEEE 802.15.4
LÉGENDE
Réseau local
de l’immeuble
WaveLinx Pro
Écran tactile
Trellix Core
BACnet/IP Public
(REST) API
Système de tiers
(matériel fourni par untiers) BACnet Router1
(matériel fourni par
un tiers)
Ordinateur de
bureau ou ordinateur
portable avec
navigateur Web
(matériel fourni par
l’utilisateur)
Remarque:
Le rendement est basé sur le contrôleur
de zone sans fil WaveLinx Pro (WAC2) de
deuxième génération.
Trellix Core Pro est montré dans cette
illustration. Le matériel Trellix Core peut
être de série Pro, Enterprise ou Virtual.
1 BACnet Router est requis seulement
si Trellix Core et le client BACnet tiers
sont sur des sous-réseaux différents.
Zone ou pièce
(49 + 1 zone de construction)
Application mobile utilisée
pour l’installationdu système et
le contrôle personnel Appareils
Appareils compatibles avec le système d’éclairage sans fil WaveLinx Pro
(jusqu’à 200 par WAC2 - 150 appareils) – Voir la remarque
Capteur de présence
de la pièce
Prise
contrôlée
Poste mural
de la scène Ambiance
intégrée
Éclairage extérieur
intégré
Bloc-commutateur de gradation
de 120-347V et 20A
Alimentation
par
câble
Ethernet
Alimentation
Contrôleur de zone
sans fil
WaveLinx Pro avec
boîtier pour l’extérieur
WaveLinx Pro
Contrôleur
de zone
sans fil
Vue d’ensemble
Le contrôleur de zone sans fil dans un boîtier pour l’extérieur est le principal composant du système d’éclairage sans fil connecté
WaveLinx Pro. Le système WaveLinx Pro élimine le coût et la complexité de la mise en service d’un système de contrôle sans fil
typique tout en offrant une topologie souple et reconfigurable pour des réglages d’espace à la volée. Le système WaveLinx respecte
les exigences de code moderne et de services publics et permet d’économiser de l’énergie et des coûts, tout en rendant les bâtiments
intelligents.
Le contrôleur de zone sans fil assure la coordination entre l’application mobile WaveLinx Pro et de nombreux appareils WaveLinx Pro
pour créer des communications et un écosystème de bâtiment qui propose un fonctionnement immédiat. Il tire également parti de nos
fonctions de mise en service automatique en attente de brevet. Grâce à une topologie conforme aux normes de réseau maillé sans fil,
le contrôleur de zone sans fil communique avec divers appareils conformes au système d’éclairage connecté WaveLinx (WCL) pour
fournir une configuration, une surveillance et un contrôle de la zone d’éclairage d’une pièce.
Le contrôleur de zone sans fil assure une coordination centralisée de plusieurs zones notamment pour la programmation d’éclairage
partiellement ALLUMÉ ou partiellement ÉTEINT, la réponse à la demande (application Trellix requise), l’éclairage, l’occupation, les
réglages de lumière du jour et le contrôle de la scène. Il est possible de connecter un seul contrôleur de zone sans fil à un réseau
local de bâtiment pour assurer une coordination pouvant aller jusqu’à 49zones d’éclairage définies par l’utilisateur et 1zone de
construction, ou plusieurs contrôleurs de zone sans fil sur un même réseau local de bâtiment pour étendre le système à des centaines
de zones, toutes accessibles au réglage, à la configuration et au contrôle au moyen de l’application mobile WaveLinx Pro.
Composants du système d’éclairage connecté WaveLinx Pro
• Contrôleur de zone sans fil (passerelle)
• Application mobile WaveLinx Pro (mise en service et commandes personnelles de l’utilisateur)
• Poste mural du système WaveLinx Pro – filaire ou à pile (éclairage manuel et contrôle de scène)
• Écran tactile WaveLinx Pro
• Capteur INstinct sans fil (capteur d’occupation intégré au luminaire, capteur de la lumière ambiante et contrôle)
• Bloc-commutateur de relais WaveLinx Pro de 0 à 10V
• Prises WaveLinx Pro (prise de courant murale)
• Capteur basé sur la salle WaveLinx Pro (capteur d’occupation à infrarouge passif monté au plafond)
Contrôleur de zone sans l (WAC2-POE) avec boîtier pour l’extérieur WaveLinx Pro
IB50301921 page 15
Juin 2022
www.cooperlighting.com

Boîtier pour l’extérieur du contrôleur de zone sans l
15.75"
[400mm]
11.81"
[300mm]
5.90"
[150mm]
1.18"
[30mm]
11.81"
[300mm]
9.33"
[228mm]
13.19"
[335mm]
0.98"
[25mm]
9.33"
[228mm]
15.75"
[400mm] 12.80"
[325mm]
M5 Threaded
Insert (4x)
11.81"
[300mm]
1.18"
[30mm]
0.44"
[11mm] 0.33"
[8mm]
0.13"
[3mm]
0.98"
[25mm]
ø0.17
[ø4mm]
(40x)
Vue intérieure de l’unité
avec le couvercle retiré
Emplacement de montage du WAC
• Installez le contrôleur sur un mur à la verticale, le plus haut possible, au centre de l’espace qu’il contrôlera.
Ne l’installez pas au plafond.
• Le contrôleur de zone sans fil doit être situé de sorte à avoir une visibilité directe (à 91m [300pi] max./pratique exemplaire à
45m [150pi]) avec les appareils avec lesquels il communique.
• Connexion Ethernet filaire à moins de 91m (300pi) d’un point de connexion au réseau local du bâtiment
• À au moins 3m (10pi) des points d’accès Wi-Fi de l’immeuble
• À au moins 5m (15pi) des structures en béton ou en métal
Le contrôleur de zone sans l NE peut PAS être installé aux endroits suivants:
• À l’intérieur d’un boîtier métallique ou près de grands objets en métal ou de murs
• À l’intérieur de grands murs ou d’espaces en béton ou près de ceux-ci
• Ne pas installer dans un placard d’installations électriques
Contrôleur de zone sans l (WAC2-POE) avec boîtier pour l’extérieurWaveLinx Pro
IB50301921 page 16
Juin 2022
www.cooperlighting.com

Installation
Installez le contrôleur de zone sans fil conformément aux codes de l’électricité et aux exigences locales, provinciales et nationales.
Environnement:
• Température de fonctionnement: -30 à 40°C (-22 à 104°F)
• Température d’entreposage: -30 à 85°C (-22 à 185°F)
• Humidité relative en fonctionnement: 5 à 90% (sans condensation)
• Pour une utilisation extérieure
Montage: Installez sur des murs extérieurs qui NE sont PAS exposés directement à la lumière du soleil.
1. Avant de monter le contrôleur de zone sans fil à son emplacement final: Installez les appareils sans fil WaveLinx Pro et vérifiez
leur fonctionnement immédiat.
2. Installez le contrôleur de zone sans fil.
• Assurez-vous que le contrôleur de zone sans fil est à peu près au centre des appareils avec lesquels il communique.
(visibilité directe: à 91m [300pi] max./pratique exemplaire à 45m [150pi]).
• Consultez la section «Emplacement de montage du contrôleur de zone sans fil» des présentes instructions
d’installation.
• Le boîtier extérieur peut être installé sur un mur avec le matériel de montage inclus.
• Les surfaces en métal et en béton affecteront le rendement de la connexion sans fil. Gardez le contrôleur de zone sans
fil dans un boîtier pour l’extérieur et qui offre une visibilité directe avec les appareils connectés.
9.92"
[252mm]
16.3"
[414mm]
Montage
Douille filetée
M5 (4x)
0.15" [4mm]
DIA
Vue de face
(porte cachée pour plus de clarté)
Protection contre
les surtensions
Alimentation
c.a. à c.c.
Thermostat
Unité de
chauffage
Connexion
Ethernet
Conduit
de 1,9cm (3/4po)
connexion
Alimentation du
contrôleur de
zone sans fil
WAC
Trou
d'évacuation
d'eau
Contrôleur de zone sans l (WAC2-POE) avec boîtier pour l’extérieur WaveLinx Pro
IB50301921 page 17
Juin 2022
www.cooperlighting.com

3. Allumez le contrôleur de zone sans fil.
• Ce produit nécessite seulement une alimentation de 120V c.a. Le contrôleur de zone sans fil contenu à l’intérieur est un appareil
PoE alimenté par un injecteur PoE de 120V c.a. pré-câblé pour faciliter l’installation par l’installateur.
4. Puissance de l’alimentation d’entrée
• Le point d’entrée pour le câblage d’alimentation se fait par le conduit de 1,9cm [3/4po] dans le bas du châssis.
• Utilisez un conduit approprié pour alimenter le câblage d’alimentation de façon sécuritaire dans le châssis.
• Consultez le diagramme ci-dessous pour obtenir les détails sur le câblage.
• Consultez l’image ci-dessous pour obtenir plus de détails sur le calibre des câbles d’alimentation maximal.
• Ne touchez pas l’unité de chauffage et ne laissez pas de câbles à proximité, car la surface peut devenir très chaude.
Puissance d’entrée
Puissance d’entrée:
120V c.a. 50/60Hz par
conduit de 3/4po
détail
WAGO détail
Connexions
L / N / GND
Renseignements sur le câblage:
Dénudez les fils sur une longueur
de 1,27 à 1,59cm (1/2 à 5/8po)
Calibres des câbles: 12AWG
Massif/torsadé en cuivre seulement
Mise à la terre
Neutre
Entrée de ligne
5. Pour les communications réseau, une connexion Ethernet câblée est requise. Connectez les câbles Ethernet appropriés pour
l’utilisation jusqu’à une distance maximale de 91m (300pi) du réseau local du bâtiment.
Ethernet external port
Port externe
Connexion au réseau
local du bâtiment
Connexion au réseau
local du bâtiment
6. Faites la connexion au réseau du bâtiment.
7. Formez un groupement de construction; consultez la section sur le groupement de construction.
8. Terminez la programmation au moyen de l’application mobile WaveLinx Pro.
• Consultez le manuel WaveLinx Pro pour obtenir de plus amples renseignements.
9. Inscrivez l’adresse IEEE indiquée dans le bas du contrôleur de zone sans fil à l’intérieur du boîtier de celui-ci, sur le plan d’étage du
site.
Contrôleur de zone sans l (WAC2-POE) avec boîtier pour l’extérieurWaveLinx Pro
IB50301921 page 18
Juin 2022
www.cooperlighting.com

Mejores prácticas de diseño de WaveLinx Pro
Considération en matière de conception Pratique exemplaire Capacité maximale
Appareils WCL par contrôleur de zone sans fil 150 200
Zones définies par l’utilisateur par contrôleur de zone
sans fil 49 49
Zones de groupement par contrôleur de zone sans fil 1 1
Zones par espace 3 16
Nombre total de zones par modèleWAC2 200 200
Scènes par espace 16 16
Portée du contrôleur de zone sans fil
(appareilsWCL intérieurs) 150ft (45m) Visibilité directe1300ft (91m) Visibilité directe2
Portée du contrôleur de zone sans fil
(appareilsWCL extérieurs) Consultez la fiche technique du capteur
Bonds de dispositif au-delà du contrôleur de zone
sans fil (intérieur/extérieur) 4 / 10 5 / 10
Remarques :
1 En tenant compte de deux (2) murs de construction standard intérieurs
2 En ne tenant compte d’aucune obstruction à la visibilité directe (murs, colonnes, etc.)
Témoins DEL du contrôleur de zone sans l
Les témoins DEL peuvent être utilisés pour les diagnostics et le dépannage du système WaveLinx Pro.
Le tableau ci-dessous vous donne plus de renseignements.
4.69"
[119mm]
4.69"
[119mm] 1.97"
[50mm]
4.80"
[122mm]
Couleur DEL Allumé Éteint Clignotant Clignotement rapide
Réseau WiFi étendu
(WAN) Vert Connexion à
OpenADR
ou à un tiers Normal Communication
depuis un tiers
Réseau local Vert Connecté au réseau
local de l’immeuble;
adresse IP reçue
Aucune connexion ou
adresse IP du réseau
local de l’immeuble
Communication
depuis le réseau
local; pendant la
configuration de la
page Web interne
Wi-Fi Bleu Connecté au réseau
local de l’immeuble;
adresse IP reçue
Aucune connexion ou
adresse IP du réseau
local de l’immeuble
Communication
depuis le réseau
local; pendant la
configuration de la
page Web interne
Réinitialisation du
nom d’utilisateur/mot
de passe lors de la
connexion
Réseau personnel
(PAN) Bleu Fonctionnalité à venir Fonctionnalité à venir Fonctionnalité à venir Fonctionnalité à venir
802.15.4 Azul Se forma la red
WaveLinx Pro
No hay dispositivos
WaveLinx Pro
vinculados
Durante la agrupación
de construcción y
las comunicaciones
WaveLinx Pro
Cuando el WAC se
establece conforme
a los valores
predeterminados de
fábrica
Contrôleur de zone sans l (WAC2-POE) avec boîtier pour l’extérieur WaveLinx Pro
IB50301921 page 19
Juin 2022
www.cooperlighting.com

Images de l’extérieur et de l’intérieur du contrôleur de zone sans l dans un boîtier
1. Port Ethernet pour la connexion au réseau local du bâtiment
pour assurer la communication.
2. Bouton de réinitialisation («RESET»)
• Réinitialise le contrôleur de zone sans fil; n’affecte pas
les réglages
3. Bouton de jumelage («PAIR»)
• Groupement de construction
• Enlever des appareils
• Réinitialiser le nom d’utilisateur et le mot de passe de
la connexion
• Paramètres d’usine par défaut
2
1
3
Contrôleur de zone sans l (WAC2-POE) avec boîtier pour l’extérieurWaveLinx Pro
IB50301921 page 20
Juin 2022
www.cooperlighting.com
This manual suits for next models
1
Table of contents
Languages:
Popular Controllers manuals by other brands

Giacomini
Giacomini PM100W Installation

Johnson Controls
Johnson Controls LN-DSWSC1-0 installation instructions

Mitsubishi Electric
Mitsubishi Electric MR-J5-G Series user manual

Logitech
Logitech FLIGHT YOKE SYSTEM user guide

Victron energy
Victron energy BlueSolar MPPT 150/45-MC4 manual

Omron
Omron SYSMAC CS1W-CLK11 Operation manual

SSV Works
SSV Works MRB2 Installation and user guide

USA Technologies
USA Technologies VendingMiser VM170 EZ Installation Instructions

ETC
ETC Echoflex ELED2 installation guide

Maxim
Maxim THOMPSON MILLER LEAMAN PDA/ATF-MAX owner's manual

SMC Networks
SMC Networks JXCD1 Operation manual

MFJ
MFJ Multi-mode Data Controller MFJ-1278B user guide