COPAL ELECTRONICS PA-870 Series User manual

PressureTransducerswithAmp.
INSTRUCTIONMANUAL
Ver.2.0
PA-870/PA-878series
PressureSwitch
PS87
series
1
HandlingNotesforSafetyuse
CAUTION …ThiscautionmarkdescribeswhenthereisapossibilitythatundermaysufferfromdamageorPhysicaldamage
mayoccuriftheproductisusedimproperly.
Caution
Caution
Caution
Beforeoperatingourproduct,readthismanualthoroughly. Youmaynotunderstandalloftheexplanationsthefirsttimethorough,butbeonthelookoutfor
anyspecialdirections.
Piping:
Installtheproductbyscrewingthepressureporttothematchingfitting.
Duringthisoperation,putthewrenchonlytothehexagonalportionanddonotgiveanyunnecessaryforcetothemainbodyandtheleadwire.
Wiring:
Theconnectionofwiringisasshowninthetablebelow.
Others:
_Thisproductcanbeusedforliquids/gasescompatiblewithSUS316andHastelloyÑC-22.
`Neverinsertaforeignmattersuchaswirethroughthepressureport.
aNevertakeintheover-pressureexceedingthemaximumpressure.
bNevershort-circuittheswitchoutputtotheotherterminals,norconnectthemtothelowimpedanceloadthatwouldallowtheoutputcurrentover100mA.
Theseconductmightdamagetheinternalcircuitry.
cUseastableDCpowersupplyforthepowersource.Asurgeabsorbingcircuit(diodes,varistor,etc.)isnecessaryifaninductiveloadsuchasarelayor
solenoidisconnectedtothepowerlineand/ortotheswitchoutput(s).TheFGterminalontheunitpowersupplyshouldbeearthed.
(Pleaserefertothefollowingdiagrams)
ThankyouforpurchasingNIDECCOPALELECTRONICS
CORP.product.
In order to use the product correctly and most
appropriately, please completely read this manual before
useandkeepitforfuturereference.
Nishi-ShinjukuKimurayaBidg.,7-5-25
Nishi-ShinjukuShinjuku-kuTokyo160-0023,JapanPhone.:(03)3364-7055
Formoredetailedinformationpleaseaskforthe
nearestdistributororthefollowingsalescenter.
EarthingtoFGterminal
TheterminalFGisgrounded
SurgesbsorbingCircuit
SwitchingPowerSupply PowerLine
Power(+)
Relay
or
Solenoid
ex.Diodes,Varistor
DCoutput
FG
ACinput
*Nevershort-circuittheswitchoutput(s)totheotherterminals,
norconnect themto thelow impedanceload thatwould allow
theoutputcurrent over100mA. These conductmight damage
theinternalcircuitry.
PA-870 PA-878 PS87
P/N
Wirecolor
Red
Black
White
Green
Gray(Shield)
Power(+)
Common
Analogoutput
None
Fitting
Power(+)
NoConnection
Output
None
Fitting
Power(+)
Power(-)
Switchoutput(+)
Switchoutput(-)
None

2
1.PARTNUMBERDESIGNATION
2.ACCESSORIES
*Pleaseconfirmthepartnumberoftheproductyoupurchased.
InstructionManual
3.SETTINGMETHODOFSWITCHINGPRESSURE
4.INTERNALELECTRICALSCHEMATICS
①TurntheHysteresissettingVR(ontheleftside)atasuitableangle.
②Applypressureuptothepointwhereswitchoperationisneeded.ThenslowlyturntheVR(ontherightside)totheclockwiseuntiltheLEDturnson.
③ReducepressureandconfirmtheLEDisturnsoff.
A:PartnamePA−870
PA-870:PressureTransducerwithAmp.(Analogvoltageoutput)
PA-878:PressureTransducerwithAmp.(Analogcurrentoutput)
PS87:PressureSwitch
B:Ratedpressurerange
203P:2[MPa] 353P:3.5[MPa] 503P:5[MPa]
*Note1.203PisnotavailableinPS87series
C:Drip-proofstructure
B:Withoutdrip-proofcover(IP-54)
H:Withdrip-proofcover(IP-65)
D:Fitting
R2:R1/4(PT1/4)
PA−870−***P−B−R2
ABCD
PA−870 PA−878
PS87
Pressure
Sensor
Main
circuit
Main
circuit
Main
circuit
Pressure
Sensor
Pressure
Sensor
Red:Power(+)DC Red:Power(+)DC
Red:Power(+)DC
White:SwitchOutput(+)
Green:SwitchOutput(-)
Black:Power(-)
Black:N.C.
White:
Output
White:AnalogOutput
Black:Common
Gray(Shield):Fitting Gray(Shield):Fitting
IndicatorLED
Note:NPNOutputApproximation
+
−
+
−
+
−
Directcurrent
Directcurrent Directcurrent
RL
V
V
RLRL

3
5.OUTLINEDIMENSIONS
6.SPECIFICATIONS
5.1 Outlinedimentions 5.2 Drip-proofcovertype
5.3 Rear
Please make sure that the drip-proof cover is properly placed
overthemainbodyandthecable.
30
17
(47.5)
15 6.5 26 Label
Housing
(SUS316)
0
−0.4
Pressureport
φ4 2000±20
φ5
7
R1/4(PT1/4)
(SUS316)
HysteresissettingVR
IndicatorLED
PressuresettingVR
PA−870/PA−878 PS87
Drip-proofcover
6.1 Generalspecifications
Item
Operatingtemp.range
Compensatedtemp.range
Operatinghumidity
Stirangetemp.
Pressuremedium
Cable
Drip-proofstructure
NetWeight
Specifications
-10〜75℃
0〜50℃
35〜85%RH(Nocondensation)
-20〜90℃(
Atmosphericpressure,humidity65%RHmaximum
)
Corrosivegases/liquidscompatiblewithSUS316andHastelloy
Ñ
C-22
3-coreshieldedcable(PA-870,PA-878)
4-corecable(PS87)
Withoutdrip-proofcover:IP-54,Withdrip-proofcover:IP-65
Approx.190g
6.2 Power
Item
Supplyvoltage
Consumptioncurrent
Specifications
10.8〜26.4VDC
10mAmaximum(PA-870)
15mAmaximum(PS87)

4
7.WARRANTY
Thisproductiscoveredbywarrantyforaperiodofoneyearfromthedateofdelivery.Thiswarrantyisonlyapplicabletothisproductitself.Thiswarrantycoversfree-of-
chargerepairandreplacementfordefectsoccurringthroughdesignormanufacturinginadequacyofNIDECCOPALELECTRONICSCORP.Evenduringthewarranty
period,thefollowingfailureswillbehandledonafeebasis.
1)Failureordamagesoccurringthroughmisuseordisoperationperformednotfollowingtheinstructionmanual,thecatalogandthespecificationsheet.
2)Failureordamagesoccurringthroughimpropermodification,adjustment,orrepair.
3)Failureordamagesoccurringthroughtechnicallyandscientificallyunpredictablefactors.
4)Replacementofaccessories(e.g.O-ringrubber,etc.)
6.3 Switchoutput(PS87)
Item
No.ofoutputs
Outputinterface
Settingmethod
Adjustablerange
Display
Accuracy
Hysteresis
Switchingcapacity
Residualvoltage
Response
Specifications
1
Opencollectoroutputwhichinsulatedaphoto-coupler
AdjustabledyVR
10〜105%ofratedpressurerange
RedLEDON
±3%F.S.(Referencetemp. :25℃)
Approx.1〜10%S.F.ofsettingrange
35VDC100mA
1.2Vmaximum
Approx.2ms
6.4 Analogoutput
Outputvoltage/current
Zerovoltage/current
Spanvoltage/current
Linearity/Hysteresis
Loadresistance
Respones
±0.5%F.S.
±0.05%F.S./℃
±0.05%F.S./℃
2msmaximum
Thermalerror
500Ωmaximum
(Atpowervoltage24V)
ZERO
SPAN
Item
Modelnumber PA-870 PA-878
1〜5VDC
1±0.05V
4±0.05V
10kΩminimum
4〜20mADC
4±0.1mA
16±0.1mA
This manual suits for next models
2
Table of contents
Popular Transducer manuals by other brands

DATUM ELECTRONICS
DATUM ELECTRONICS M425 Handbook & installation guide

Garmin
Garmin gWind Race installation instructions

Viatran
Viatran 28H Installation data manual

Graco
Graco 25B128 installation manual

Ashcroft
Ashcroft GC55 Installation and maintenance instructions

ETH-messtechnik
ETH-messtechnik DRVL Operator's manual