manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CORFLEX
  6. •
  7. Home Gym
  8. •
  9. CORFLEX Marathon Air Walker Ankle User guide

CORFLEX Marathon Air Walker Ankle User guide

This manual suits for next models

5

Popular Home Gym manuals by other brands

T.D.S. 3501 Assembly instructions

T.D.S.

T.D.S. 3501 Assembly instructions

Body Solid EXM1950 Assembly instructions

Body Solid

Body Solid EXM1950 Assembly instructions

Horizon Fitness OXFORD 6 manual

Horizon Fitness

Horizon Fitness OXFORD 6 manual

Energetics Multi Trainer 5.1 owner's manual

Energetics

Energetics Multi Trainer 5.1 owner's manual

Precor Discovery Series owner's manual

Precor

Precor Discovery Series owner's manual

Matrix MG-PL Series Service manual

Matrix

Matrix MG-PL Series Service manual

Reebok Tbr2i Manuale d'istruzioni

Reebok

Reebok Tbr2i Manuale d'istruzioni

Weider 8300 Hard Drive manual

Weider

Weider 8300 Hard Drive manual

Pure Fitness 8526HE owner's manual

Pure Fitness

Pure Fitness 8526HE owner's manual

Weider 8700 I Bedienungsanleitung

Weider

Weider 8700 I Bedienungsanleitung

Bowflex Sport 001-6961 Assembly instructions

Bowflex

Bowflex Sport 001-6961 Assembly instructions

NordicTrack E8200 Competition Bench Bedienungsanleitung

NordicTrack

NordicTrack E8200 Competition Bench Bedienungsanleitung

Insportline RW600 user manual

Insportline

Insportline RW600 user manual

Weider WEMC10161 user manual

Weider

Weider WEMC10161 user manual

Body Solid GHYP-345 owner's manual

Body Solid

Body Solid GHYP-345 owner's manual

Evo TAHOE 5105 user manual

Evo

Evo TAHOE 5105 user manual

ParaBody 40 Assembly instructions

ParaBody

ParaBody 40 Assembly instructions

JLL Ventus Pro Air Power instruction manual

JLL

JLL Ventus Pro Air Power instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

°°
CORFLEX.COM | 800 426 7353
1. Place leg inside liner and position heel as
far back as possible. Close forefoot cover
over top of foot and fasten it snugly.
Fitting and Application
MarathonTM Air Walker
Ankle
Application Instructions
2. Wrap liner around the front of lower leg
and secure with hook and loop closures.
POSITION FOREFOOT
COVER OVER TOP OF FOOT
WRAP LINER AROUND
FRONT/LOWER LEG
FOREFOOT COVER
The Marathon Air Walker features an
inatable interior bladder that allows for a
custom t while providing compression and
stabilization throughout recovery.
3. Situate front shell over liner taking care
to properly position it over the ination bulb.
Check that the inate/deate knob is in the
DEFLATE position before tightening straps,
this will allow air to escape from the bladder.
The front shell should not contact the foot or
leg, adjust as needed.
5. Secure forefoot strap. Insert top strap
through outer shell slot, then through front
shell and fasten back on itself.
Fitting and Application (continued)
4. Insert initial ankle strap through plastic
buckle and secure strap. Always secure this
strap rst to encourage proper positioning in
the walker.
6. Test for desired comfort level, do not
overtighten straps.
INSERT STRAP THROUGH
REAR AND THEN FRONT
OUTER SHELL
SECURE ANKLE STRAP
FIRST FOR PROPER FIT
TIGHTEN STRAPS
UNTIL SECURE AND
COMFORTABLE
INFLATE LINER
CAUTION:
DO NOT
OVERINFLATE
LINER
CAUTION:
DO NOT
OVERTIGHTEN
STRAPS
PRESS AND RELEASE
INFLATION BULB AND
TURN THE INFLATE/
DEFLATE KNOB
COUNTERCLOCKWISE
7. To inate liner, turn the inate/deate
knob clockwise until fully opened and
press and release ination bulb until liner is
providing support and comfort.
1339/12-19GM-5088-000
Troubleshooting:
If you cannot inate or deate the liner check that metal valve located on
the top of the ination bulb is not blocked.
If you cannot inate or deate the liner check that the inate/deate valve
is in the correct position.
If boot does not t snugly at top of boot, move the top strap to the
alternate vertical top slot located in the plastic shell.
Care Instructions:
Liner should be hand washed only using warm water and detergent for
delicate fabrics, repeatedly rinsed and line dried only. Do not use bleach or
place in a dryer. Wipe plastic shell with damp cloth, you may use
disinfectant or mild soap and wipe dry.
Caution:
This product has been designed and tested based on single patient
use only. It should never be used by multiple patients. If additional pain,
swelling or symptoms occur while using the device, seek medical attention.
Product should be applied by a licensed or certied healthcare practitioner
and as prescribed by a physician or other qualied medical authority.
Indications:
Indicated for stable foot fractures, severe sprains, soft tissue injuries,
post-op and post-cast removal.
Warranty:
Products manufactured by Corex are warranted to the original purchaser
against defects in workmanship and material for the life of the product.
The foregoing warranty shall not apply to normal wear and tear; or if the
product has been subjected to misuse or misapplication the warranty will
be voided at the discretion of Corex.
CORFLEX | 669 EAST INDUSTRIAL PARK DRIVE | MANCHESTER, NH 03109
CORFLEX.COM
|
TOLL FREE: 800 426 7353
|
FAX: 603 623 4111
Fitting and Application (continued)
Marathon Air Walkers
TURN THE INFLATE/DEFLATE
KNOB COUNTERCLOCKWISE
TO RELEASE AIR
CLOCKWISE
INFLATES LINER
COUNTERCLOCKWISE
RELEASES AIR FROM
THE LINER
7. To release air from liner, turn the inate/
deate knob counterclockwise several
times. If at any time the liner feels too tight,
immediately release air by turning the inate/
deate knob counterclockwise.
Designed to increase stability and decrease
edema, our walker features a built-in pump to
achieve desired level of compression. Ideal for
stable foot/ankle fractures, severe
sprains, soft tissue Injuries, post
cast removal and post surgical
application. Custom sole and
low prole non-skid bottom and
adjustable toe protector promotes
natural gait. Available in two heights,
ankle and tall.
•DEFLATE LINER BEFORE REMOVING THE AIR WALKER.
• PRESSURE CAN BE ADJUSTED BY TIGHTENING AND LOOSENING STRAPS.
• DO NOT OVERINFLATE.
• FOLLOW PHYSICIANS INSTRUCTIONS.
XS S M L XL
Marathon Air Walker Ankle 79-2020 79-2021 79-2022 79-2023 79-2024
Replacement Liner Ankle 79-2040 79-2041 79-2042 79-2043 79-2044
XS S M L XL
Men's Size 3-4 4½-7 7½-10 10½-12½ 13+
Women's Size 4-5½ 6-8 8½-11 11½-13 14+
To Reorder:
Product Number
Sizing Guide
Measured by Shoe Size