Cornell Series 1000 User manual

Door Monitor Systems
Series 1000
rev 6/04
CORNELL Communications, Inc.
Milwaukee, WI USA
800-558-8957 - www.cornell.com
CORNELL
Emergency Response Systems
OPERATION AND WIRING INSTRUCTIONS
BASIC SYSTEM OPERATION:
Each zone switch contains a red and a green LED. Each time the zone switch is pressed, the zone status toggles between
armed and disarmed.
The green LED indicates the disarmed status. The associated door may be opened without causing an alarm. A short
and/or open in the door contact wiring will cause the panel to go into the alarm condition.
A steady red LED indicates the armed status. If an armed door is opened, the alarm condition occurs. The red LED will
flash and an intermittent audio tone will sound. Pressing the cancel tone switch on the master panel will silence the audio
tone but will not clear the alarm. If another zone should go into the alarm condition, the tone would again sound until the
cancel tone switch is pressed or until all alarms are canceled.
To cancel an alarm, simply press and release the zone switch. This will return the zone to the disarmed status and
automatically cancel the alarm.
POWER SUPPLY REQUIREMENT:
The A-1000 Series Door Monitor System is designed to operate on regulated 12VDC power. Connecting an AC power
source or a DC power supply with a voltage above 12V will damage the system. Make sure you are using one of the
following CORNELL power supplies: P-512241A, P-512243A, or the B-5243A. Use minimum 18 gauge 2 conductor
wiring from power supply to the Master Panel. The B-5243A power supply provides battery back up allowing a typical
system to operate 24 hours or more on back-up power.
WIRING:
All wiring to be minimum 22 gauge unless otherwise specified. Refer to drawing D1000W-A for basic system wiring
information.
SYSTEM FEATURES:
Adjustable alarm volume - Volume of intermittent tone is adjustable with a screwdriver from the front of the
master panel.
Door contacts - The system can use either normally open (N.O.) or normally closed (N.C.) contacts. Two 22
gauge wires required between door switch and zone card. Refer the drawing D1000W-A.
Auxiliary output per zone - Each zone card has a switched negative (open collector) transistor output at
terminal 9, which turns on whenever that zone is in the alarm condition. Rating: 500mA, 40VDC
Auxiliary output, system - The “RM” terminal on the tone board is a switched negative (open collector)
transistor output, which turns on whenever any zone is in the alarm condition. Automatically turns off when all
alarms are canceled. Rating: 100mA, 12VDC
Door Status Output - Each zone card has a door status output at terminal 11-switched negative, (open collector)
transistor that turns on whenever the door is open, regardless of armed/disarmed status. Rating: 100mA, 12VDC
Zone Switch Disable - Cutting the factory installed Zone Switch Enable jumper between terminals 1 and 3 of a
zone card will disable the zone switch from making changes in the armed/disarmed status of the door. Status
changes will then only be possible using a remote zone control product (see OPTIONS-REMOTE ZONE
MONITOR/CONTROL PRODUCTS).
Zone Switch Disable during alarm - Cutting jumper J1 on a zone card will disable the zone switch from making
changes in the armed/disarmed status of the door only when the zone is in the alarm condition. The zone switch
will still function while the zone is either disarmed or armed. Once in the alarm condition, clearing the alarm will
only be possible from a remote zone control product. Note: If the Zone Switch Enable jumper (see Zone Switch
Disable) is cut, the zone switch will be disabled under all conditions.
A-1000 SERIES DOOR MONITOR
OPTIONS-REMOTE ZONE MONITOR/CONTROL PRODUCTS
A-1600 -The Remote Control Panel duplicates the functions of the Master Panel except it has a high/low switch instead
of a “Cancel Tone” switch for control of the alarm tone. When the Master Panel tone is silenced the tone for the Remote
Control Panel is also silenced. Individual zones have one green LED, one red LED, and a momentary three position,
center neutral toggle switch. Activating the toggle switch to the left or right will disarm or arm the zone, respectively.
More than one A-1600 panel may be used.
Wiring: Two 18-gauge conductors, one 22-gauge conductor plus four 22-gauge conductors per zone, all to master panel.
Refer to drawing DA1600WM.
A-1700 - The Remote Monitor Panel provides a visual and audible indication of any or all zones. Each zone contains
one green LED and one red LED. The panel contains a tone hi/low switch to control the audible alarm tone volume.
When the Master Panel tone is silenced, the tone at the A-1700 panel is also silenced. More than one A-1700 panel may
be used.
Wiring: Two 22-gauge conductors, one 22 conductor plus two 22-gauge conductors per zone, all to master panel. Refer
to drawing DA1600WM.
A-1800 - Remote control station for a single zone comprised of one green LED, one red LED, a key switch, and a toggle
switch on a single gang stainless steel plate. The key switch will enable/disable the use of the toggle switch. When
enabled, the toggle switch will change the status of that zone.
Wiring: Requires 5-conductor 22-gauge cable to Master Panel. Refer to drawing DA1800WM.
A-1801- A key operated switch with built-in timer designed to permit authorized personnel to pass though the door
when the zone is armed. The A-1801 has a key switch and red LED mounted on a single gang stainless steel plate. The
red LED will glow when the zone is armed. The red LED will flash when the zone is in the alarm condition. Operating
the key switch will disarm the zone and start the timer allowing the user to pass through the door. After the user
adjustable time period (1 second to one minute, approximately) that zone will automatically re-arm itself.
Wiring: Requires 5-conductor 22-gauge cable from switch to Master Panel. Refer to drawing DA1800WM.
A-1802 - A key switch and a red LED on a single gang stainless steel plate. It is designed to be used in conjunction with
the A-1801. A typical application would consist of an A-1802 installed on the outside of a secured door allowing entry
into the building when the zone is armed. Operating the key switch starts the timer in the A-1801 disarming the door.
After the delay period of the A-1801 timer, the zone will automatically re-arm itself. The red LED will glow when the
zone is armed and will flash when the zone is in the alarm condition.
Wiring: Requires four 22-gauge conductors to A-1801. Refer to drawing DA1800WM.
A-1806D - A keypad station with arm/disarm exit-delay feature. The exit delay feature will disarm the zone for a user
programmable period of 10-60 seconds allowing passage though an armed door. At the end of the delay period, the zone
will automatically re-arm itself. The A-1806D contains a 12-key keypad, a red LED, a green LED, and a yellow LED on a
two-gang stainless steel plate. The green LED glows when the zone is disarmed. The red LED glows when the zone is
armed and flashes when the zone is in the alarm condition. The yellow LED glows during the exit-delay period.
Wiring: Requires six 22-gauge conductors to Master Panel. Refer the drawing DA1806WM.
A-1808D -A keypad station with the exit delay feature. The zone cannot be armed or disarmed using the A-1808D.
Wiring: Requires six 22-gauge conductors to Master Panel. Refer to drawing DA1806WM.
A-1900 and A-1901 - Disable switch - Master Panel. Option to disable individual zone switches at the Master Panel.
Switch may be mounted on the Master Panel or at a remote location on single gang stainless steel plate (A-1900).
Wiring: Use 2 conductor cable from switch location to pins 1 and 3 on terminal (edge connector) as shown. Jumper from
pin 1 to pin 3 must be removed. The disable feature can be wired to selected zones. Refer to drawing DA1900WM.
D1000P
DA1800WM
FEATURES
-User programmable via keypad
-Allows any 1-6 digit access code
-Keypad programmable 10-60 second exit time delay
-Allows remote arm and disarm functions
-Remote exit time delay input from momentary SPST switch
-48 hour (minimum) power-loss code retention
GENERAL
The keypad must be programmed before it will operate. If the keypad contains no programming when powered up, the
yellow LED will flash rapidly. The user must enter the programming mode.
PROGRAMING MODE
To enter the programming mode, the following sequence of keys must be entered: *,0,0,*, then #. This is the
programming mode access code. During entry of the above keys, the yellow LED will turn off. If these keys are not
entered properly the yellow LED will again begin flashing rapidly awaiting the programming mode access code. If the
code is entered correctly, the yellow LED will pulse once. At this point, enter the desired 1-6 digit function access code
that will allow access to door functions, followed by the # key. For example, to enter function access code 1-2-3, enter
1,2,3,#. The keypad will acknowledge by pulsing the yellow LED twice. Now enter the exit time delay period, in
seconds, followed by the # key (must be 10-60 seconds). For example, to program a 15 second delay, enter 1-5-# . The
keypad is now programmed and will automatically enter the operating mode.
Note: If an invalid function access code is entered during programming (i.e., 7 digit code) the programming mode will be
exited leaving the previously stored function access code in place or returning to the power-up condition if no code had
been previously stored. Also, if an invalid exit time delay period is entered, the 10-second default value will be used.
OPERATING MODE
To access any door functions, the function access code must be entered followed by the “#” key. If the correct code is
entered, the yellow LED will flash three times. Any of the three functions can now be used.
1. To disarm the zone, press and release the “*” key.
2. To arm the zone, press and release the “#” key.
3. To initiate an exit time delay cycle, press and release the “0” key. The yellow LED will light for the duration of the
time period. During this time, the door may be entered/exited without causing an alarm and will re-arm automatically at
the end of the delay period again securing the door.
At anytime while in the operating mode, the exit time delay cycle can be initiated by
momentarily connecting terminals 3 and 4 of the keypad together with a SPST switch.
Also, at anytime while in the operating mode, the programming mode can be accessed to change the keypad programming
by entering the programming mode access code (see PROGRAMING MODE).
POWER-LOSS MODE
If power is removed from the keypad it will not function. However, its programming will be maintained for a maximum
of 48 hours. If power is restored within 48 hours (maximum), the keypad will automatically resume operation. If power
is not restored in time to preserve the keypads programming, it will need to be re-programmed when power is restored.
A-1806D REMOTE CONTROL KEYPAD
Rev 8/05
FEATURES
-User programmable via keypad
-Allows any 1-6 digit access code
-Keypad programmable 10-60 second exit time delay
-Remote exit time delay input from momentary SPST switch
-48 hour (minimum) power-loss code retention
GENERAL
The keypad must be programmed before it will operate. If the keypad contains no programming when powered up, the yellow LED
will flash rapidly. The user must enter the programming mode.
PROGRAMING MODE
To enter the programming mode, the following sequence of keys must be entered: *,0,0,*, then #. This is the programming mode
access code. During entry of the above keys, the yellow LED will turn off. If these keys are not entered properly the yellow LED
will again begin flashing rapidly awaiting the programming mode access code. If the code is entered correctly, the yellow LED will
pulse once. At this point, enter the desired 1-6 digit function access code that will allow access to door functions, followed by the #
key. For example, to enter function access code 1-2-3, enter 1,2,3,#. The keypad will acknowledge by pulsing the yellow LED twice.
Now enter the exit time delay period, in seconds, followed by the # key (must be 10-60 seconds). For example, to program a 15
second delay, enter 1-5-# . The keypad is now programmed and will automatically enter the operating mode.
Note: If an invalid function access code is entered during programming (i.e., 7 digit code) the programming mode will be exited
leaving the previously stored function access code in place or returning to the power-up condition if no code had been previously
stored. Also, if an invalid exit time delay period is entered, the 10-second default value will be used.
OPERATING MODE
To use the exit time delay function, the function access code must be entered followed by the “#” key. If the correct code is entered,
the yellow LED will flash three times. Press and release the “0” key to initiate an exit time delay cycle. The yellow LED will light
for the duration of the time period. During this time, the door may be entered/exited without causing an alarm and will re-arm
automatically at the end of the delay period again securing the door.
At anytime while in the operating mode, the exit time delay cycle can be initiated by
momentarily connecting terminals 3 and 4 of the keypad together with a SPST switch.
Also, at anytime while in the operating mode, the programming mode can be accessed to change the keypad programming by entering
the programming mode access code (see PROGRAMING MODE).
POWER-LOSS MODE
If power is removed from the keypad it will not function. However, its programming will be maintained for a maximum of 48 hours.
If power is restored within 48 hours (maximum), the keypad will automatically resume operation. If power is not restored in time to
preserve the keypads programming, it will need to be re-programmed when power is restored.
1808D REMOTE CONTROL KEYPAD
Rev 8/05

Other manuals for Series 1000

1

Popular Security System manuals by other brands

ELRO ARD51 manual

ELRO

ELRO ARD51 manual

NAPCO MAGNUM ALERT-850 manual

NAPCO

NAPCO MAGNUM ALERT-850 manual

PGST CT-PG-100 user manual

PGST

PGST CT-PG-100 user manual

First Alert FA200C user manual

First Alert

First Alert FA200C user manual

Polaroid ID-3000 Repair manual

Polaroid

Polaroid ID-3000 Repair manual

Sabik Marine Vega VLB-44X Series product manual

Sabik Marine

Sabik Marine Vega VLB-44X Series product manual

WirelessAlert TextAlert IV user manual

WirelessAlert

WirelessAlert TextAlert IV user manual

SecurityMan DigiLCDNDVRB user manual

SecurityMan

SecurityMan DigiLCDNDVRB user manual

Turing SKYSHIELD Setup guide

Turing

Turing SKYSHIELD Setup guide

Gent Nano operating instructions

Gent

Gent Nano operating instructions

ABC Office Vector 06502 user guide

ABC Office

ABC Office Vector 06502 user guide

Terex Genie Lift Guard GS-30 Operator's manual supplement

Terex

Terex Genie Lift Guard GS-30 Operator's manual supplement

Quell Q7DCO User and installer guide

Quell

Quell Q7DCO User and installer guide

ADEMCO via30+ installation instructions

ADEMCO

ADEMCO via30+ installation instructions

Evolveo SONIX user guide

Evolveo

Evolveo SONIX user guide

Data Aire MINI DATA ALARM PROCESSOR II Operation and maintenance manual

Data Aire

Data Aire MINI DATA ALARM PROCESSOR II Operation and maintenance manual

Steren TRS-400 user manual

Steren

Steren TRS-400 user manual

Tynetec Reach Plus User's installation guide

Tynetec

Tynetec Reach Plus User's installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.