Contents
2User Guide
The communication wires and power line should NOT be bound in the same conduit or tubing.
Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the
reader malfunction.
The standard installation: Door relay and lock use the same power supply, and reader use independent power supply.
Use AWG 22-24 Shielded Twist Pair to avoid star wiring ,CAT 5 cable for TCP/IP connection
1.Tubing:
2.Wire selection:
3.Power supply:
1Products 3Terminal Cables 4Tools
Notice
Connector Table (1)
5Optional
Wire Application Wire Color Description
Lock Relay 1Blue White (N.O.)DC24V1Amp
2
Purple White
(N.C.)DC24V1Amp
Lock Relay COM 3White (COM)DC24V1Amp
Door Contact 4Orange Negative Trigger Input
Exit Switch 5Purple Negative Trigger Input
Alarm Relay 6Gray Transistor Output Max. 12V/100mA
(Open Collector Active Low)
Power 7Thick Red DC 12V
8Thick Black DC 0V
Cable: P1
Wire Application Wire Color Description
RS-485 for Lift
Controller
1Thick Green RS-485(B-)
2Thick Blue RS-485(A+)
Cable: P4
Wire Application Wire Color Description
1 --- ---
2 --- ---
TCP/IP Output 3
Orange White
Net - TX+
4Orange Net - TX-
5Green White Net - RX+
6Green Net - RX-
7 --- ---
P3
Cable:
Wire Application Wire Color Description
Beeper 1Pink Beeper Output 5V/100mA, Low
LED 2Yellow Red LED Output 5V/20mA, Max
3Brown Green LED Output 5V/20mA, Max
Door Output 4Blue White Transistor Output Max. 12V/100mA
(Open Collector Active Low)
Wiegand 5Thin Green Wiegand DAT: 0 Input
6Thin Blue Wiegand DAT: 1 Input
WG Door Contact
7Orange Negative Trigger Input
WG Exit Switch 8Purple Negative Trigger Input
P2
Cable:
Use a screwdriver to screw the mounting plate to the wall.
Pull cables ends through the access hole in the mounting plate.
Attach ACC995-V2 to the mounting plate and install screws (supplied) into the holes at the
bottom with the allen key.
Apply power. LED (green) will light up with one beep.
Installation
ECL-ACC995-V2

V151027
14 : 49 : 04
WED Duty:0
12 07
Ready...
14 : 49 : 04
WED Duty:0
12/07
Ready...
Biometrics Device Access controller
Fingerprint
Front Panel & Indicator
1. System will automatically exit from Programming Mode when inactivating for 30 seconds.
2. LED status indicates controller’s mode and status.
OK (green) – blinking constantly when operates in Programming Mode
– or ashing an existed card in card learn mode, it comes 2 beeps warning and LCD panel displays “Same Card: user address / card number”
Error (red) – invalid card with 2 beeps warning and LCD panel displays “Card Number Err!”
– or in anti-pass-back mode, when violates the access, it comes one beep warning and LCD panel displays “Anti-pass Error!”
Arming (green) – arming on status
Alarm (red) – any abnormal condition occurs
3. Keypad will be locked up 30 sec. when constantly entering incorrect pin code or master code.
4. Maximum error in[ut of pin code and master code can be changed via the software 701Server (default: 5 times)
Power(Green)
Alarm(Red)
Alarm(Green)
OK(Green)
Error(Red)
In processing(Green)
Networking : / and interactively ash between the Month and DAY.
[e.g.] 12/07←→12 07
Stand-alone : No ashing [e.g.] 12/07
(←Reference to picture)
Connect to Electric Bolt
Wiring Diagram
EXIT
1
2
3
4
5
6
7
8
E
12V
GND
Exit Switch
12V
GND
12V
GND
N.O.
GND
N.O.
COM
PB
12V
GND
P1
Electric Bolt
Controller
RTE
POWER
12VDC
POWER
12VDC
EXIT
1
2
3
4
5
6
7
8
N.C.
COM
PB
12V
GND
12V
GND
12V
GND
12V
GND
N.O.
GND
P1
Controller
RTE
POWER
12VDC
POWER
12VDC
Magnet Lock
Connect to Magnet Lock
Connector Table (2)
Wire Application Wire Color Description
Power 1 Red DC 12V Output
Security trigger signal
2Purple Security trigger signal Output
Arming 3 Red White Arming Output
Duress 4 Yellow White Duress Output
P6
Cable:
Wire Application Wire Color Description
Anti-Tamper Switch 1Red N.C.
2Orange COM
3Yellow N.O.
P5
Cable:

COR-ACC995-V2
V151027
N.C.
N.O.
COM
CTL
12V
E
E
BZ
RLED
GLED
WG 0
WG 1
12V
GND
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
1
2
3
4
5
6
12V
GND
Exit Switch
12V
GND
12V
GND
12V
GND
12V
GND
12V
GND
PB
PB
COM
COM
N.O.
N.O.
P2
P1
P1
P1
BZ
RLED
GLED
Door Output
WG 0
WG 1
WG-DS
WG-PB
7
8
EXIT
1
2
3
4
5
6
7
8
1 2 3
N.C.
N.O.
COM
CTL
12V
GND
PB
12V
GND
12V
GND
N.O.
12V
GND
12V
GND
DDR
P1
P6 ACC-899
4
12V
N.C.
EXIT
RTE
EXIT
1
2
3
4
5
6
7
8
12V
GND
12V
GND
PB
COM
N.C.
P1
EXIT EXIT
Controller Controller
Reader
RTE
RTERTE
RTE
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
Electric Strike
Door Contact
Strengthen security with ACC-899
If any re emergency, the people can escape by press a switch to open all doors
Electric Bolt Electric Bolt
Electric Bolt
Fire Emergency
Transistor
IN4007
Transistor
IN4007
Connect to Reader
Magnet Lock
Connect to Electric Strike Connect to Door Contact
EXIT
1
2
3
4
5
6
7
8
12V
GND
12V
GND
12V
GND
N.O.
GND
N.O.
COM
PB
12V
GND
P1
Controller
RTE
POWER
12VDC
POWER
12VDC
Electric Strike
1
2
3
4
5
6
7
8
N.C.
N.O.
COM
CTL
12V
Door Contact
ALM
12V
GND
12V
GND
12V
GND
12V
GND
N.C.
P1
Controller
POWER
12VDC
POWER
12VDC
Alarm
Relay Outpot Module
Door Contact

V151027
Biometrics Device Access controller
Fingerprint
E. PIN Code
Access programming mode → User Setting → Password → Input 5-digit user address → Input 4-digit PIN (0001~9999) → Succeeded
Or via 701Client set it on Users screen
21
C. Initial setup
Node ID of Reader Setting
Access programming mode → Parameters[1] → Node ID → Input New Node ID : 1~254 (default value:001) → Main Door Number : 0~255
→ WG1 Door Number : 0~255 → Show UID (0=No,1=WG,2=ABA,3=HEX) → Enable DHCP(0:No,1:En,2=Exit) → Succeeded
3 1
Language Setting
Access programming mode → Tools → Language → EN → Succeeded → Initial system...
5 1 0
Programming
B. Entering and Exiting Programming Mode
Exiting
Press the repeatedly → Quit or Quit and Arming (Please refer to alarm / arming setting)
6
Changing the Master Code
Access programming mode → Tools → Master Code → Input the 6-digit new master code → Succeeded
5 2
A. Keyboard Lock/ Unlock
Lock/ Unlock
Press and , and at the same time to lock keyboard. Press again to unlock.
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456. If already changed the Master Code= 876112, input 876112 → Access programming mode
P.S.If entering no instruction within 30 sec., it will automatically leave the programming mode.
7
Access programming mode → Add/Delete → Add -> RF-Learn → Input 5-digit user address
→ Input Tag Units(pcs) → Close Tag into RF Area
※If a batch of tags are Sequential, input Tag Units(pcs) in the quantity of the tags and present the tag with
the lowest number to the controller.
1 2
Adding Tag by RF Learn Function
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
※ User capacity: 16384 (00000~16383)
Access programming mode → Add/Delete → Add -> Card ID → Input 5-digit user address → Input Site Code → Input Card Code
1 1
Adding Tag by Tag ID
Access programming mode → Add/Delete → Delete -> Addr → Input Start address → Input End address
1 5
Deleteing User Address
Access programming mode → User Setting → Access Mode → Input User Address → 0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN
2 2
Setting up the access mode
Access programming mode → Add/Delete → Delete -> ID # → Input Site Code → Input Card Code
1 6
Deleteing Tag by Tag ID
Access programming mode → Add/Delete → Suspend -> Addr → Input Start address → Input End address
1 3
Suspend User Address
Access programming mode → Add/Delete → Suspend -> ID # → Input Site Code → Input Card Code
1 4
Suspend Tag by Tag ID
Access programming mode → Add/Delete → Delete -> Addr → Input Start address → Input End address
1 7
Recover User Address
Access programming mode → Add/Delete → Delete -> ID # → Input Site Code → Input Card Code
1 8
Recover Tag by Tag ID
D. Adding and Deleting Tag

COR-ACC995-V2
V151027
H. Arming Password
J. Duress Code
K. Terminal Port
I. Arming Delay Time
Access programming mode → Parameters[1] → Arming PWD → Input 4-digit PIN (0001~9999; Default: 1234) → Succeeded
Or via 701Server and set it on ACC995-V2 screen
38
Or via 701Server to set it on ACC995-V2 screen
※Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to computer as a
warning signal.
Access programming mode → Parameters[2] → Duress Code → 4 sets (select one) → Input 4-digit PIN (0001~9999) → Succeeded
4 7
Access programming mode → Tools → Terminal Port → 0:Lift ; 1:Host ; 2:LED ; 3:PRN (default value:1) → Baud Selection
(default value:9600) → Succeeded
5 4
L. Setting up the alarm / arming
Conditions:
1. Arming enabled
2.Alarm system connected
Application:
1. Door open too long: Door is open longer than door relay time plus door close time.
2. Force open (Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal: When power is off and then on, reader on arming before power off.
Enable/Disable the arming status:
Standby Mode
Access Programming mode
Card only Card or PIN Card and PIN
Open the door
Present the tag to reader → Input
4 digits arming PWD →
Input user address → Input 4
digits individual PWD → →
Input 4 digits arming PWD →
Present the tag to reader → Input
4 digits individual PWD → →
Input 4 digits arming PWD →
Enable: Access programming mode → Quit & Arming
7Disable: Access programming mode → Quit
6
No open the door
→ Input 4 digits arming PWD
→ Present the tag to reader
Access programming mode → Parameters[1] → ArmingDelayTm → Enter armed sta. Delay time(Sec) ,Range:000~255
;
Armed pulse out-put time. (10ms) ,Range
:
000~255 → Succeeded
37
※ [Use FP] can substitute for [Induct valid card].
F. Adding / Deleting Fingerprint or Finger-Vein
Adding
Access programming mode → User Setting → Enroll FP → Key in 5-digit user address →1 or 2 different ngers on the sensor lens → Succeeded
P.S. The ACC995-V2 need to collect twice for each ngerprint.
2 6
Deleting
Access programming mode → User Setting → Delete FP → Key in 5-digit user address → Succeeded
P.S. If you want to delete all users’ FP, key in 99999
2 7
#
G. Access Mode
Access programming mode → User Setting
→ Access Mode
→ Key in 5-digit user address (00000~08999)
→ 0:Invalid; 1:Card; 2: Card or PIN; 3: Card and PIN
→ Finger Identify: 0: Must ; 1: Ignore
→ Succeeded
2
2
Access Mode Finger Identify Result
Hardware 701Client Hardware 701Client
0:Invalid
0: Must Just ngerprint
Just card control Invalid User
1: Ignore Just ngerprint
Just card control
1:Card
0: Must Just ngerprint
Just card control Finger+Card
1: Ignore Just ngerprint
Just card control
1. Card Only
2. Finger Only
2:Card or PIN
0: Must Just ngerprint
Just card control
1. Finger+Card
2. Finger+PIN
3. Card+Finger+PIN
4. Card+Finger+Card
5. PIN+Finger+PIN
6. PIN+Finger+Card
1: Ignore Just ngerprint
Just card control
1. Card Only
2. PIN Only
3. Finger Only
3:Card and PIN
0: Must Just ngerprint
Just card control Finger+Card+PIN
1: Ignore Just ngerprint
Just card control
1. Card+PIN
2. Finger+PIN

V151027
Biometrics Device Access controller
Fingerprint
O. Alarm Clock (for Factory)
P. OpenZone
Q. Open TimeZone
Hardware installation
M1
Board
Horn M2
1
2
3
4
5
6
7
8
N.C.
N.O.
COM
CTL
12V
ALM
12V
GND
GND
P1
Output to M1 and M2
Mike device
Mike device
Music Box
Music Box Mike's sound wire
Mike's sound wire
DC 12V Relay Board
Controller
POWER
12VDC
Access programming mode → Tools → Daily Alarm → Set (00~15) → Set Start Tm (24 Hours) ; Set Effect Sec.
(Seconds as the bell time, Range:1~255) → Set Weekday (0:disable, 1: enable) → Succeeded
5 9
Access programming mode → Parameters[1] → OnOff OpenZone → Main Controller Auto Open Zone (0:disable,1:enable) →
Open Door Imm. During Open Zone (0:No,1:Yes) → WG1 Port Auto Open Zone (0:disable,1:enable) → Open Door Imm. During
Open Zone (0:No,1:Yes) → Succeeded
3 2
N. Lift control
[e.g.] Connect with Lift Controller to control which oors the user will be able to access. (BAUD9600)
Access programming mode → Tools → Terminal Port → 0
:
Lift Controller → Baud Selection 0
: 9600
5 4
Setting Lift control
Access programming mode → User Setting → Single Floor →
Input 5-digit user address → Input single oor number: 1~64
2 4
Single oor
Access programming mode → User Setting → Multi Floor → Input 5-digit user address → Select range: 1 or 2 or 3 or 4 → Input 16 digits
multi oors number [0:disable, 1: enable]
[e.g.] Set NO. 114, can use it with the 8 F and 16F:
Access programming mode → User Setting → Multi Floor → 114 → 1 → 0000000100000001
2
2
5
5
Multi oors
Set Floor/ Stop
1
0
17
0
33
0
49
0
9
0
25
0
41
0
57
0
1
2
3
4
3
0
19
0
35
0
51
0
11
0
27
0
43
0
59
0
2
0
18
0
34
0
50
0
10
0
26
0
42
0
58
0
4
0
20
0
36
0
52
0
12
0
28
0
44
0
60
0
5
0
21
0
37
0
53
0
13
0
29
0
45
0
61
0
6
0
22
0
38
0
54
0
14
0
30
0
46
0
62
0
7
0
23
0
39
0
55
0
15
0
31
0
47
0
63
0
8
1
24
0
40
0
56
0
16
1
32
0
48
0
64
0
Access programming mode → Tools → Terminal Port → 1
:
Lift Controller
(need to use 725L485)
5 5
Access programming mode → Tools → Open TimeZone → Set (00~15) → Time (24 Hours) ; Main Port (0:disable, 1: enable) ;
WG Port (0:disable, 1: enable) → Weekday (0:disable, 1: enable) → succeeded
5 6
M. Anti-pass-back
Device enable
Access programming mode → Parameters[2] → Anti-pass-back → master controller select [1: Yes] → WG select [1: Yes]
4 6
Card user enable
Access programming mode → Add/ Delete → Antipass Group → Input 5-digit starting user address → Input 5-digit ending user
address → must select [1: Yes]
1 9

COR-ACC995-V2
V151027
RESET
Transfer ngerprint format V9 -> V2
Restoring Factory Settings
Software Settings on 701Server
Reset all device parameters and user card data
Uploading,downloading and deleting fingerprint
database via 701Server
Downloading ngerprint database from PC to the devices
Reset IP Setting:
When the device's power is on, press the
【
RESET】
button the main board untill the ERR (Red) LED of
screen lights up. (Reference to picture)
※ After operation as above, you will hear the long reminder sound,and wait until the sound
disappear then reset the power of the controller,the device will restore factory setting.
Manu Tree
5. Tools
1. Language
2. Master Code
3. Master Range
4. Terminal Port
5. Ext.Comm Port
6. Open Time Zone
7. Informations
8. Clock Setting
9. Daily Alarm
6. Quit
7. Quit & Arming
4. Parameters[2]
1. Auto Relock
2. Egress(R.T.E)
3. Miscellaneous
4. Force Open
5. Close & Stop
6. Anti-pass-back
7. Duress Code
8. Password Mode
9. Factory Reset
3. Parameters[1]
1. Node ID
2. OnOff OpenZone
3. Door Relay Tm
4. Door Close Tm
5. Alarm Relay Tm
6. Alarm Delay Tm
7. Arming Delay Tm
8. Arming PWD
2. User Setting
1. Password
2. Access Mode
3. Extend Options
4. Single Floor
5. Multi Floor
6. Enroll Finger
7. Delete Finger
1. Add/ Delete
1. Add > Card ID
2. Add > RF Learn
3. Suspend > Address
4. Suspend > ID #
5. Delete > Address
6. Delete > ID #
7. Recover > Address
8. Recover > ID #
9. Antipass Group
Reset all device parameters and user card data:
Access programming mode → Parameters2 → Factory Reset →0 : System Param ;
1 : User Setting ; 2 : System & User
94
First of all,please make sure users have registered their ngerprints
to the device.
1.Select node number of the device.
2.Click"Read".
3.Setting "User Range".
4. Click "Read Fingerprint".
5.Status popped up.
5
※ After done the "Factory Reset", the External Communication Port must be reset. Or the
biometric sensor won't be functional.
Tools → Ext. Comm Port (0:FP-200 ; 1:Lift ; 2:Vein2000 ; 3:FP-9000 ; 4:Reserved )
5
Uploading ngerprint database to PC
Deleting ngerprint database on the device
1
263
5
7
4
8
9
6.By selecting "Selected Only or All Connected Controller".
7.Click"Write Fingerprint".
3.Select the range of the ngerprints to be deleted.
8.Click"Delete Fingerprint".
9.Click "Transfer (V9-->V2/V5)" and select old ACC995 V9 FP le
format. SIF , the system will generate new single FP le format.
FP5 into 701Server folder.

V151027
admin
Biometrics Device Access controller
Fingerprint
IP Setting
Log-in User Password
When you choose the "Networking Setting" or "User Password" at rst.
Log-in window will pop out and please input
※ At the Factory Default
User name: admin
Password: No as default value,so please just press “OK” to log-in
Open your Web Browser and input factory default IP
address: http://192.168.1.127
Networking Setting
You will nd initial IP Address 192.168.1.127 and check
MAC Address is the same as sticker on Ethernet Module
device. Please revise IP address you want, and then click
“Update” button. After updating the IP, please re-connect
the Web Browser by new IP address.
User Password
The password composes of 10 characters at most, it can be
either A~Z or 0~9.
Change the log-in password to lock the IP setting of
Ethernet Module.
If the IP address of ACC995-V2 has
changed We must enter the new IP
address.
Show which computer is linking
on Ethernet Module.
Current IP address of the ACC995-V2
Page menu
Current State
Online Status is able to monitor and
show which computer is linking on Ethernet Module
IP Setting
Monitor the on-line computer
Change the Log-in information