manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cosmo
  6. •
  7. Control Unit
  8. •
  9. Cosmo CKPL User manual

Cosmo CKPL User manual

Other Cosmo Control Unit manuals

Cosmo CKZM User manual

Cosmo

Cosmo CKZM User manual

Cosmo CFWME User manual

Cosmo

Cosmo CFWME User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Power Supply from the CKL6230N wiring centre
Max load 5 (2) A
Dimensions [mm] 80 x 80 x 20
CKPL module extends the functionality of the CKL6230N wiring
centre.
The module is used to control the pump using N / E / L contacts.
It helps to save electrical power. Whenever there is no heat demand,
the pump will be unpowered and not wasting any energy.
This product complies with the essential requirements and other
relevant provisions of the following EU Directives: EMC 2014/30/EU,
Low Voltage Directive LVD 2014/35/EU, RoHS directive 2011/65/EU.
Use in accordance to national and EU regulations. Use the device
as intended, keeping it in dry condition. Product for indoor use only.
Installation must be carried out by a qualified person in accordance
to national and EU regulations.
Before any of operation releated to power supply (connecting
wires, installing the device, etc.), make sure that the device is not
connected to any power source. Incorrect connection of the wires
may cause damage to the wiring centre. The module can not be
used in conditions of water vapor condensation neither exposed
to water.
The serial connector from the CKL6230N wiring centre provides
communication between the wiring centre and the CKPL module.
CKL6230N wiring centre + CKPL module increases functionality
and additionally makes possible to control pump. CKPL module is
powered from the wiring centre.
COSMO GmbH
Brandstücken 31
22549 Hamburg
info@cosmo-info.de
www.cosmo-info.de
March 2020
V003
Pump Logic Module
Model: CKPL
Quick Guide
INTRODUCTION
SERIAL CONNECTOR FOR
CKPL MODULE
PRODUCT COMPLIANCE
SAFETY INFORMATION
TECHNICAL SPECIFICATION
TERMINALS DESCRIPTION
fuse (T10A)
LN
LNLNLNLN
LNLN
1
1
2
2
3
3
4
4
5
5
6
6
N N N N
N N
TERMINAL DESCRIPTION
N Neutral pin
Earth pin
L Pump output
Note: All terminals are screwless, push type.
Make sure that all the wires are properly connected, mount top
cover and power up the wiring centre - the green „Power” indicator
LED will illuminate.
These are used to set in minutes the delay time (overrun time).
Default setting is „0”.
0-5 values specify the time in minutes. E.g. when jumper is set to
value „0”, the module will turn off as soon as the thermostats stop
calling for heat. If jumper will be set to the value „5”, the module will
turn off 5 min after the thermostats stop calling for heat.
They are used to select the zone which turns on the module. Default
setting is „P”.
P– all zones start the module
1, 2, 3, 4, 5, 6 – select the specific zone which turns on the module.
Remove the top cover of the wiring centre.
Note: Before connecting the module, disconnect the main power
from the CKL6230N wiring centre.
Connect the module to the serial connector.
JUMPERS DESCRIPTION LED INDICATION
INSTALLATION
WIRING DIAGRAM
JUMPERS P, 1, 2, 3, 4, 5, 6
PUMP CONTROL
JUMPERS 0-5
1
2
3
LED DESCRIPTION
Green Pump is running
Red Pump is off
LN
min
Nachlaufzeit P 1
40 5 5 6
2 3
LN
min
Nachlaufzeit P 1
40 5 5 6
2 3
LN
min
Nachlaufzeit P 1
40 5 5 6
2 3
max 5 (2) A