Covert Systems SurvDome User manual

COVERT-
SYSTEMS.COM
928-759-2121
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Control System Operations Manual
LAW
ENFORCEMENT
PRODUCTS
Operations Manual
CS-RS485-Interceptor
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
DTMF Control System
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
SurvDome
Operation's Manual
Controlled Using
Covert-Systems.com
CS-RS485
Interceptor Module
With
Pelco D&P Extended Codes
Rapid SurvDome OSD Codes
& Rapid Presets Setup
DTMF
RS-485
Pelco P or D

COVERT-
SYSTEMS.COM
928-759-2121
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
Note:
User Defined RS485 Functionality Available
DTMF Control System FEATURES
LAW
ENFORCEMENT
PRODUCTS
FEATURES
CS-RS485-Interceptor
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
DTMF Control System
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
INTERCEPTOR-2
Order: Model KS-IC-2
Features:
DTMF to RS485 Control System
Pan, Tilt, Zoom, Focus or Iris Control
on any Pelco D or Pelco P device
Including all current extended codes
With rapid OSD access codes
for Covert Systems *SurvDome
including Battery BU Real Time Clock
and ID Line Automated Codes
Plus standard Baud rate selection
Video Server RS485 Interceptor Relay
Also provides normally active Video
Server control until DTMF is activated
Any Standard telephone may be
powered by the Interceptor which then
provides telephone control
* Note: Several phones my be paralled
DTMF radio control, 3.5mm Mono Jack
Remote Power On/Off 20 Amp Relay
* Microwave Power
12 Volt DC Operation
Dimensions:
Weight:
Input Voltage:
Input Current:
Temp Range:
Input Control:
Output Control:
DTMF Functions:
Codes:
4.3 x 2.9 x 1.0"
5 oz
10 to 16 Vdc
100 to 150 mA
-20 to 65 Deg. C
Video Server/DTMF
RS485
PTZ + Power Relay
Pelco D & P
DTMF
RS-485
Pelco P or D
* SurvDome
KSC-260Z

OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System SurvDome Setup
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
COVERT-
SYSTEMS.COM
928-759-2121
BLOCK DIAGRAM
CS-RS485-Interceptor
SurvDome
KSC-260Z
KSC-300Z
RS485 CONTROL
SurvDome VIDEO
Note:
All equipment is 12VDC Powered
User Defined RS485 Functionality Available
SurvDome Setup
Covert-Systems.com CS-485-Interceptor_Flyer.pdf

TRANSMITTER
12VDC IN
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System Radio Control Block Diagram
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
COVERT-
SYSTEMS.COM
928-759-2121
BLOCK DIAGRAM
CS-RS485-Interceptor
Video
Transmitter
KST-1550
SurvDome
KSC-260Z
KSC-300Z
Control
Receiver
VHF or UHF
RS485 CONTROL SWITCHED POWER
DTMF
SurvDome VIDEO
Note:
All equipment is 12VDC Powered
User Defined RS485 Functionality Available
Radio Control
Covert-Systems.com CS-485-Interceptor_Flyer.pdf

OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System Radio/Video Server Block Diagram
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
COVERT-
SYSTEMS.COM
928-759-2121
BLOCK DIAGRAM
CS-RS485-Interceptor
Video
Transmitter
KST-1550
SurvDome
KSC-260Z
KSC-300Z
Video
D/A
Video
Server
KS-VS-2
Control
Receiver
VHF or UHF
TRANSMITTER
12VDC IN
RS485 FROM SERVER RS485 CONTROL
SWITCHED PWR
DTMF IN
VIDEO TO TRANSMITTER
VIDEO TO SERVER SurvDome VIDEO
Note:
All equipment is 12VDC Powered
User Defined RS485 Functionality Available
Radio / Video Server
Covert-Systems.com CS-485-Interceptor_Flyer.pdf

OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System Pawn-Shop Setup
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
COVERT-
SYSTEMS.COM
928-759-2121
Pawn-Shop Setup
CS-RS485-Interceptor
RS485 CONTROL
SurvDome VIDEO
Time-Lapse
*Note:
Trunk Line 2 may be any trunk line not connected
to the telephone company (previously unused).
To operate the SurvDome or Pelco D/P coded device
simply switch to that line number. The Interceptor will
power the trunk line. Continuous tones must be output
when a key is pressed for the system to work.
SurvDome Setup
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
Phone
Trunk
*Line 2

COVERT-
SYSTEMS.COM
928-759-2121
DTMF
Code Basics
CS-RS485-Interceptor
SurvDome Setup
OSD Menu Items (10-)
DTMF Keypad Codes
KEYPAD CODE BASICS
SURV-DOME
DTMF
RS-485
Pelco P or D
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System DTMF Code Basics
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
Note:
All equipment is 12VDC Powered
User Defined RS485 Functionality Available
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
SINGLE KEY Control Functions
'1' Power Relay ON (4 Times)
& Start of Non-OSD Function Codes
'2' TILT UP
'3' Power Relay OFF (4 Times)
& Start of OSD Function Codes
'4' PAN LEFT
'5' ZOOM IN
'6' PAN RIGHT
'7' *IRIS CLOSE
'8' TILT DOWN
'9' *IRIS OPEN
'*' FOCUS NEAR
'0' ZOOM OUT
'#' FOCUS FAR
1. Single Key Control Functions (All others end with '#')
2. 1111# Power Relay On, 3333# Power Relay Off
3. 3330# Intercept on Tones Only, 3331# Always Intercept Server Control
4. Codes starting with '1' = Non-OSD Functions
5. Codes starting with '3' = SurvDome OSD Functions
FN
IC
COD
PL
ZO
TU
TD
ZI
FF
IO
OSD
PR
D
C
A
B
* The SURV-DOME OSD's ALC Iris default setting is "AUTO". The
Iris may not be changed until ALC is set to "FIXED".

COVERT-
SYSTEMS.COM
928-759-2121
Rapid Presets & Group Codes
CS-RS485-Interceptor
SurvDome Setup
OSD Menu Items (10-)
PRESET Functions (SurvDome preset positons 1 through 31)
Presets and Group Codes
SURV-DOME
DTMF
RS-485
Pelco P or D
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System Rapid Presets and Group Codes
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
User Defined RS485 Functionality is Available upon request
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
GROUP Functions
1301# Start Group No. 1 (Sequence through Presets 1-4)
1302# or 1305# Start Group No. 2 (Sequence through Presets 5-8)
1303# or 1309# Start Group No. 3 (Sequence through Presets 9-12)
1304# or 1313# Start Group No. 4 (Sequence through Presets 13-16)
GROUP DWELL Functions
1101# Dwell Set to 1 Second (Stay on each preset positon 1 second)
1105# Dwell Set to 5 Seconds
1110# Dwell Set to 10 Seconds
1130# Dwell Set to 30 Seconds (Stay on each positon preset 30seconds)
GROUP SPEED Functions
1202# 1106# 1112# Move 2, 6, 12 degrees-per-second between presets
1230# Move 30 degrees per second between presets
1260# Move 60 degrees per second between presets
12120# Move 120 degrees per second between presets
Pan/Tilt and Zoom SurvDome to each desired position to set presets
14XX# Set Preset number XX (1401# for preset 1)
15XX# Clear Single preset number XX (1509#clears preset 9)
16XX# Recall Preset number XX (1525#for preset 25)
1X# or 1XX# Quick Codes for Recall Preset number XX
(11#for preset 1, no leading zero required)
17XX# Clear 4 Presets numbers XX through XX+3
Examples:
1702# Clear Presets number 2 through 5
1413# Clear Presets number 13 through 16

COVERT-
SYSTEMS.COM
928-759-2121
Preset Setup Example
CS-RS485-Interceptor
SurvDome Setup
OSD Menu Items (10-)
Preset Setup Proceedure
Rapid Preset Setup Example
SURV-DOME
DTMF
RS-485
Pelco P or D
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System Preset Setup Example
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
User Defined RS485 Functionality is Available upon request
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
1. Zoom out to full zoomed out position, pan & tilting as desired
2. Set preset 1 code by entering 1401#
3. Zoom to front of round camera housing
4. Set preset 2 code by entering 1402#
5. Zoom to front of rectangular window
6. Set preset 3 code by entering 1403#
7. Zoom in to flag area
8. Set preset 4 code by entering 1404#

COVERT-
SYSTEMS.COM
928-759-2121
Preset Setup Example
CS-RS485-Interceptor
SurvDome Setup
OSD Menu Items (10-)
When recalling presets 1 through 4 you view images shown
Rapid Preset Setup Example
SURV-DOME
DTMF
RS-485
Pelco P or D
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System Preset Setup Example
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
User Defined RS485 Functionality is Available upon request
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
1. Recall preset 1 code by entering 1601#or QuickCode 11#
2. Recall preset 2 code by entering 1602#or QuickCode 12#
3. Recall preset 3 code by entering 1603#or QuickCode 13#
4. Recall preset 4 code by entering 1604#or QuickCode 14#
5. To sequence through these images enter Group 1 Code1301#
Group 1 always sequences through Presets 1-4 on SurvDome
Preset 1
Preset 3
Preset 2
Preset 4

COVERT-
SYSTEMS.COM
928-759-2121
Using Group Sequencing
CS-RS485-Interceptor
SurvDome Setup
OSD Menu Items (10-)
Group Sequencing
SURV-DOME
DTMF
RS-485
Pelco P or D
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System Using Group Sequencing
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
Preset 1 Preset 3Preset 2 Preset 4
LAW
ENFORCEMENT
PRODUCTS
Dwell Time Code
1101#, 1105# or 1130#
Seconds
Group Speed Code
1202#, 1206#, 1212#,
1230#, 1260# or 12120#
Degrees-Per-Second
DWELL
4 PLCS
Group
1
= Presets 1-4
Group
2
= Presets 5-8
Code 13
01
# & 13
02
#
Group 1
Shown Here
Group
3
= Presets 9-12
Group
4
= Presets 13-16
Code 13
03
# & 13
04
#
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314

COVERT-
SYSTEMS.COM
928-759-2121
Image Reversal Codes
CS-RS485-Interceptor
SurvDome Setup
OSD Menu Items (10-)
Image Reversal Codes
SURV-DOME
DTMF
RS-485
Pelco P or D
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System Image Reversal Codes
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
User Defined RS485 Functionality is Available upon request
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
Image 2 (V-Flip only)
By Entering 328# or 382#
(3 + TILT KEYS + #)
Image 1
May be corrected directly to
Image 3 by either of these
Codes 32846#, 32864#,
38246# or 38264#
(3 + PAN +TILT KEYS+ #)
Image 3
After Mirroring Image 2 by
entering codes 346# or 364#
(3 + PAN KEYS + #)

COVERT-
SYSTEMS.COM
928-759-2121
Pan/Tilt Key Reversal Codes
CS-RS485-Interceptor
SurvDome Setup
OSD Menu Items (10-)
Pan/Tilt Key Reversal Codes
SURV-DOME
DTMF
RS-485
Pelco P or D
OSD Menu Items (10-)
LAW
ENFORCEMENT
PRODUCTS
DTMF Pelco P&D Control System Pan/Tilt Key Reversal Codes
LAW
ENFORCEMENT
PRODUCTS
Covert Systems. com
, 12305 Triple T Lane, Prescott Valley, AZ 86314
User Defined RS485 Functionality is Available upon request
Covert-Systems.com CS-485-Interceptor_Flyer.pdf
Reversing either Pan or Tilt keys is performed
the same way as flipping or mirring the image with
the exception that a '1' is used in place of the '3' as
the first key pressed in the code.
To flip an image vertically you would enter code
328#or 382# (3 + TILT KEYS + #).
To flip an image horizontally you would enter code
346#or 364# (3 + PAN KEYS + #).
1) Tilt Key direction reversal
To Reverse the tilt key's direction you enter code
128#or 182# (1 + TILT KEYS + #).
2) Pan key direction reversal
To Reverse the pan key's direction you enter code
146#or 164# (1 + PAN KEYS + #).
This manual suits for next models
1
Table of contents
Other Covert Systems Security Camera manuals