CPI 01N31LM User manual

5/17 920900-02
Owner’s Manual for
01N31LM and 01N12LM
Electronic Water Meters
IMPORTANT NOTICE
Use this meter for water only. Do not use to meter
fuels or chemicals.
The meter is very sensitive to electrical “noise” andmay not operatecorrectly if locatednearsome
electrical
equipment.

5/17 920900-02
CALIBRATION
This meter has a permanent factory calibration for measuring water. If installed and used correctly,
inaccuracies of no greater than ±5% will be obtained.
INSTALLATION
This meter may be installed in-line either horizontally or vertically or at the end of the hose adjacent to
the nozzle, if present. Installation to metal connections is not recommended. Install as follows:
1. If necessary, remove nozzle from hose.
2. Apply pipe sealant to all threaded connections.
3. Attach meter to hose with arrow on outlet port pointed in the direction of flow.
4. If necessary, attach nozzle to meter.
5. Hand tighten the meter at the housing ends. Do not use a wrench or similar tools to tighten
the meter housing. The plastic housing could be damaged.
OPERATION
Batch and Cumulative Totals
The meter maintains two totals. The batch total may be reset to measure flow during a single use. The
cumulative total provides continuous measurement and may not be manually reset. The batch total is
labeled as TTL1. The cumulative total is labeled TTL2.
When the cumulative total reaches a maximum reading of 9999, it will automatically reset to zero.
Press the DISPLAY button briefly to switch between the batch and cumulative total.
ActivatetheMeter
Turn the meter ON by starting water flow or briefly pressing the DISPLAY button. The meter will display
the batch or cumulative total from last use.
Press DISPLAY briefly to display the batch total. Hold the DISPLAY button down for three seconds to
reset the batch total to zero.
The meter is programmed to turn off automatically if not used for about one minute.
MAINTENANCE
Proper handling and care will extend the life and service of the meter.
Turbine Rotor
The meter is virtually maintenance-free. However, it is important the rotor moves freely. Keep the meter
clean and free of contaminants.
If the rotor does not turn freely, apply a penetrating lubricant on the rotor, shaft, and bearings. Remove
any debris or deposits from the rotor using a soft brush or small probe. Be careful not to damage the
turbine rotor or supports.
CAUTION: Blowingcompressed airthroughthe
turbine assembly could damage the rotor.
Battery Replacement
The meter is powered by two AAA alkaline batteries which may be replaced while the meter is installed.
When batteries are removed, or lose power, the batch and cumulative totals reset to zero but the
factory calibration is retained.
If the meter display becomes dim or blank, replace the batteries as follows:
1. Remove the four Phillips-head screws from the face of the meter and lift the faceplate from

5/17 920900-02
the turbine.
2. Remove the old batteries and clean any corrosion from the terminals.
3. Install new batteries. Make sure the positive post is in the correct position.
4. When the batteries are replaced, the face plate will power ON. Check the display to ensure
normal functions have resumed before assembling again.
5. Reseat batteries, if necessary, and position the faceplate on the turbine housing. To avoid
moisture damage, make sure the O-ring is fully seated. Tighten the four screws on the
faceplate.
SPECIFICATIONS
Model:
01N31LM
UnitofMeasure:
Litres
Flowrate:
11to113LPM
Working Pressure:
10.3bar
Operating Temperature:
-10°Cto+54°C
Storage Temperature:
-40°Cto+70°C
Threads:
1inchNPT
Model:
01N12LM
UnitofMeasure:
Litres
Flowrate:
11to113LPM
Working Pressure:
10.3bar
Operating Temperature:
-10°Cto+54°C
Storage Temperature:
-40°Cto+70°C
Threads:
1inch ISO7 (BSPT)
Limited Warranty Policy
Great Plains Industries Australia, hereby provides a limited warranty against defects in material and
workman-ship
on all products manufactured by Great Plains Industries, Inc. This product includes a 1
year warranty fromdateof
purchase as evidenced by the original sales receipt. A 18 month warranty from
product date of manufacture will
apply in cases where the original sales receipt is not available.
Reference product labeling for the warranty
expiration date based on 18 months from date of
manufacture. Manufacturer’s sole obligation under the foregoing
warranties will be limited to either, at
Manufacturer’s option, replacing or repairing defective Goods (subject to
limitations hereinafter
provided) or refunding the purchase price for such Goods theretofore paid by the Buyer, and
Buyer’s
exclusive remedy for breach of any such warranties will be enforcement of such obligations of
Manufacturer. The warranty shall extend to the purchaser of this product and to any person to whom such
product
is transferred during the warranty period.
This warrantyshall notapply if:
A.
the product has been altered or modifiedoutsidethe warrantor’sduly appointedrepresentative;
B.
the product has been subjected to neglect, misuse, abuse or damage or has been installed
or operated other than inaccordancewiththe manufacturer’soperatinginstructions.
Tomakeaclaimagainstthiswarranty,contacttheyourlocalFLOMECdistributororGPIAustralia
Customer
GPI will stepyou through a product troubleshooting process to determine appropriate corrective actions.
GREAT PLAINS INDUSTRIES AUSTRALIA, EXCLUDES LIABILITY UNDER THIS WARRANTY FOR
DIRECT,
INDIRECT, INCIDENTAL AND CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR
LOSS OF USE OF THE
PRODUCT WARRANTED HEREUNDER.
The company herewith expressly disclaims any warranty of merchantability or fitness for any particular
purpose other
than for which it was designed.
GPI Australia also provides automatic guarantees of all goods according to Australian Consumer Law.

5/17 920900-02
Declaration of Conformity
Manufacturer's Name:
Great Plains Industries Australia
Manufacturer'sAddress:
1/16 Atkinson Rd, Taren Point,
NSW, Australia, 2219
Declares, that the product:
Product Name: Electronic Digital Meter
Model Numbers: 01A12LM-A, 01N12LM, 01A31LM-A,
01A52LM-A, 01N31LM
Conforms to the following Standards:
EMC:
EN 50081-1 : 1992 (Reference EN 55022)
EN 55082-1 : 1992
Supplementary Information:
-
The products comply with the requirements of the EMC Directive 89/336/EEC.
-
The products conform to Council Directive 2011/65/EU and 2002-95-EC as amended
(RoHS Directive)
relating to the restriction of certain hazardous substances in
electrical and electronic equipment.
-
This product is not recommended for custody transfer or application where levying by
consumption takes
place.
-
This product has insufficient internal volume size or pressure ratings to meet a pressure
directive.
-
Year of Manufacturing is displayed directly on the product as Manufacturing Date
Code (Mfg.) indicating month and year.
Ithe undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
Signature:
Full Name: Matthew Wyres
Position:
Engineering Manager
Great Plains Industries Australia
Place:
Taren Point, NSW, Australia
May, 2017
© 2017 GREAT PLAINS INDUSTRIES, INC.All Rights Reserved.
and FLOMEC are registered trademarks of Great Plains Industries, Inc.
This manual suits for next models
1
Table of contents
Popular Measuring Instrument manuals by other brands

iSystem
iSystem Aurora RH850 user manual

Danfoss
Danfoss ADAP-KOOL AK-LM 340 user guide

Myron L
Myron L bluDock Ultrameter III installation instructions

Gastops
Gastops ChipCHECK CC120 Health and Safety Precautions Booklet

Hanna Instruments
Hanna Instruments HI96722 user manual

sauter
sauter TD 225-0.1US. instruction manual