CREE LIGHTING SmartCast CSC-GW-CWC-W User manual

INSTALLATION INSTRUCTIONS
CSC-GW-CWC-W
SmartCast® Wireless Gateway with WiFi
LPN00655X0001A0_C
1 of 3
1
RJ45 Cable Port
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed
including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l’alimentation avant l’installation.
2. Must be installed in accordance with the NEC or your local electrical code. If you
are not familiar with these codes and requirements, consult a qualied electrician.
Ce produit doit être installé conformément à NEC ou votre code électrique local.
Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter
un électricien qualié.
3. Indoor use only and Suitable for Damp Locations.
Pour usage interieur seulement et convient aux emplacements humides.
4. This equipment shall be installed and operated with a minimum distance 20cm
between the radiator and your body.
L’équipement doit etre installe d’une facon qu’une distance minimum de 20cm soit
maintenue entre l’emetteur et toute partie du corps.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
• Suitable for use in other Environmental Air Space (Plenums)
in accordance with section 300.22,(C) of the National Electrical
Code, and Sections 2-128, 12-010(3) and 12-100 of the Canadian
Electrical Code, Part 1 CSA C22.1
Peut être utilisé dans de gaines transportant de l’air traité,
conformément à la section 300.22,(C) du National Electrical Eode
et aux articles 2-128, 12-010(3) ET 12-100 du Code Candian de
l’électricité Premiére partie, CSA C22.1.
• Plenum rated cables need to be used when the SWG is installed in
a plenum.
• SWG needs to connected to PoE networks without routing to outside
plant connections.
• When this product is supplied by the Listed Direct
Plug-In Power Unit Starwell Technology PSE-480050US it is
intended to be used in a 25C environment up to 2000m.
T-BAR MOUNTING
STEP 1:
Plug customer supplied Ethernet RJ45
cable into the RJ45 cable port located on the
backside of the device. See Figure 1.
NOTE: Plenum rated cables need to be used
when the SWG is installed in a plenum.
STEP 2:
Insert the T-Bar clip into the back of the SWG
unit using provided screw as shown in
Figure 2.
STEP 3:
NOTE: Before you attach the SWG device,
please save the details from the label on the
back of the device - SSID and password. You
will need these details to login and connect to
the device over Wi-Fi.
To attach the SWG device to the ceiling
T-bar, rotate the device counter clockwise 45
degrees and apply an upward force to engage
the T-bar clip. While maintaining the upward
force, rotate the device clockwise 45 degrees
to snap and lock the device to the T-bar.
STEP 4:
Connect the supplied Ethernet RJ45 cable to
the POE wall supply (POE Port) .
2
T-Bar Clip
Arms
T-Bar Clip
Screw
Back of the SWG Unit

LPN00655X0001A0_C
2 of 3
SURFACE MOUNTING USING JUNCTION
BOX ADAPTER-
REQUIRES CSC-GW-JBOX-ADPTR
STEP 1:
Using provided screw, washer and spacer attach
the metal plate to the back of the SWG unit as
shown in Figure 4.
STEP 2:
Plug supplied Ethernet RJ45 cable into the RJ45
cable port located on the device. See Figure 3.
NOTE: Plenum rated cables need to be used
when the SWG is installed in a plenum.
STEP 3:
Insert provided (2) screws or drywall screws
into the slots on each end of the metal plate and
attach the unit to the desired surface or mount.
See Figure 5.
STEP 4:
Rotate the whole unit 45 degrees clockwise in
order to hide the screw holes. See Figure 5.
STEP 5:
Connect the supplied Ethernet RJ45 cable to the
PoE wall supply (PoE Port).
STEP 6:
Please make sure the device is powered and
operational. Please refer to the STATUS LED
INDICATOR TABLE in the Troubleshooting section
on page 3.
STEP 7:
Please proceed to configure the device using
SmartCast documentation available at
https://www.creelighting.com/touchscreen-help.
4
Metal Plate
Washer
Screw
Back of the SWG
Unit
Metal Plate
Slot
3
RJ45 Cable Port
Spacer
5
Screw in
Metal Plate
Slot to Attach
to Surface or
Mount
Screw in Metal
Plate Slot to
Attach to Surface
or Mount
Mounting
Surface

LPN00655X0001A0_C
3 of 3
www.creelighting.com
© 2019 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content
is subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree®and the Cree logo are
registered trademarks and the Cree SmartCast Technology logo is a trademark of Cree, Inc. SmartCast®, is a registered
trademark and OneButtonTM is a trademark of Cree Lighting, A company of IDEAL INDUSTRIES.
TROUBLESHOOTING:
If LEDs do not illuminate:
1. Check that the ethernet cable is connected to a the power
supply and the power is turned on.
2. Check that the network cable is fully seated in the connector on
the back side of the SmartCast Wireless Gateway such that the
locking feature is fully engaged.
STATUS LED INDICATOR TABLE
STATUS CODE Issue
LED COLOR PATTERN DESCRIPTION
Red Any Hardware error. Contact Cree
Lighting Support.
Purple 10 Blinks User initiated Factory Reset.
Blue
2 Blink SWG is in DISCOVERY mode.
4 Blinks SWG is in CONFIG mode
Green Solid System operational. No issues
detected.
FCC NOTICE
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the device.
This device has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the device is operated in a commercial environment.
This device generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of
this device in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his
own expense.
In addition, this device complies with ICES-005 of the Industry Canada
(IC) Regulations.
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation
of the device. In addition, this device complies with ICES-005 of the
Industry Canada (IC) Regulations.
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas
produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
Table of contents