GENERAL DESCRIPTION
During the production of float glass, one side of the molten glass comes into contact with a bath of molten tin, Traces of tin
or tin oxide metal are deposited on the surface of glass as is removed from the molten tin bath. This surface of the glass is
identified as the ‘ TIN SIDE· surface of the glass. The opposite side of the glass Is denoted as the “AIR SIDE’. The presence
of the tin is invisible to the human eye. Glass processors find it beneficial to know which surface of the glass is the tin side
surface, since the tin side of the glass results in a smoother surface (among other reasons).
The TS1320 Commercial Tin Side Detector is very helpful in identifying the tin side. Short-wave UV energy causes the tin
to fluorescence at a frequency that is visible to the human eye. When the lamp is placed on the tin side surface, the tin will
fluoresce and produce a milky while image that Is visible to the human eye. If you place the lamp on the non-tin side of the
glass, the lack of tin results in no fluorescence and therefore only the duller image of the UV lamp is seen. Since the float
glass substrate does not transmit the UV light, the tin coating on the opposite side of the glass is not exposed to the UV
energy, and therefore It will only fluoresce when the lamp is placed on the tin side of the glass.
WARNING
Do not expose eyes and skin to shortwave ultra violet light, as rays are harmful to unprotected eyes and skin. Never view
the image of the lamp directly without placing a piece of glass between your eyes and the lamp. We recommend the user
wear the UV Blocking safely glasses supplied with the product UV light is not visible to the human eye. Although the UV
lamp may appear dim, recognize that this is only a small percentage of the intensity being emitted by the lamp. Your eyes
cannot detect the full intensity of the short-wave UV lamp.
FEATURES
• Identify the tin side of float glass using a custom UV lamp for detection
• Also works on coated glass as long as coaling does not block UV-C energy
• Commercial design Includes a rubber boot for rugged applications
• Bulb mounting system absorbs shock of dropping the unit. better than previous competing models
• Drop tested to withstand falls up to five feet
• Momentary power switch allows user to pulse the power to see the tin side glow much easier, plus helps conserve
life of batteries
• Slide switch also included for extended use of the lamp
• Low Battery indicator
• Powered by only three-AA batteries (included)
• 50% longer battery life than previous competing models, despite fewer batteries
• Protective UV blocking safety glasses included
• Replaceable lamp option, with convenient Insertion sockets for easy replacement
• Extended warranty period compared with previous models

GLASS DRILL INSTRUCTION MANUAL
INSTRUCTION MANUAL
crlaurence.com
C.R. Laurence Co., Inc. •2503 E. Vernon Ave., Los Angeles, CA 90058 •1.800.421.6144 •crlaurence.com
NOVEMBER 2020
P. 3
POWER SWITCH
The momentary (membrane) power switch is the preferred switch to use for the TS1320 product. This switch minimizes
the use of the lamp in between tests, and extends the life of the batteries. As described later in this operating manual,
being able to cycle the power on and off also aids in the determination of the tin side glow.
The continual power (slide) switch should only be used when the operator is going to be taking repeated measurements
continuously, with few breaks.
OPERATION
You can use the TS1320 in three different methods. You can either choose to view the image of the lamp through the glass
by placing the instrument on the bottom side of the glass, OR you can tilt the TS1320 on the top surface of the glass and
view the reflection of the lamp under the meter. You may find that one approach may work better for certain glass sam-
ples and various lighting conditions. BEFORE performing any tests, we recommend putting on the protective UV blocking
safety glasses that were supplied with the product.
TRADITIONAL BOTTOM SIDE METHOD
To test glass using the bottom side method, place the TS1320 on the bottom side of the glass, as shown in Figure 1. Tum
on the power, but do not view the image of the lamp unless it is placed behind the glass. If the bottom side is the TIN SIDE
of the glass, the Image of the lamp will appear milky white (Figure 1). The intensity of the lamp may even appear lo get
stronger. There are 2 simple ways to improve the viewing of the glow. The first is louse the momentary power switch on the
meter to pulse the power on and off. The pulsing power magnifies the difference between a tin side glow versus no glow.
The second method is to wave the meter closer and further away from the glass surface to magnify the glow differential. In
certain situations it may be easier to view the milky white image at a slight angle. Viewing the Image at an angle is especially
helpful when working with tinted and reflective glass.
If you are on the air side of the glass, there will be no milky while glow. The image of the lamp will remain unchanged as
shown below.
CONTINUAL POWER
(Slide switch) power stays on continuously when
the slide switch is moved to the ON position
MOMENTARY POWER
(Membrane switch)power only stays on while
the membrane switch is being depressed
FIGURE 2:
Air Side (NOT Tin Side)
Dull violet lamp image
FIGURE 1:
Tin Slide Milky
while image

GLASS DRILL INSTRUCTION MANUAL
INSTRUCTION MANUAL
crlaurence.com
C.R. Laurence Co., Inc. •2503 E. Vernon Ave., Los Angeles, CA 90058 •1.800.421.6144 •crlaurence.com
NOVEMBER 2020
P. 4
TRADITIONAL TOP SIDE METHOD
To test glass using the top side method, place the TS 1320 on the top surface of the glass, as shown in Figure 3. Using this
method, it is important that you put on your UV blocking safety glasses. Turn on the power but DO NOT look directly at the
lamp. Tilt the unit at a slight angle so you can view the REFLECTION of the lamp.
If the reflection of the lamp on the glass appears milky white (Figure 3), then the top surface of the glass is the TIN SIDE.
The Intensity of the lamps reflection may even appear to get stronger. Again, there are two simple ways to improve the
viewing of the glow. The first is to use the momentary power switch on the meter to pulse the power on and off. The
pulsing power magnifies the difference between a tin side glow versus no glow. The second method Is to wave the meter
closer and further away from the glass surface to magnify the glow differential. In certain situations it may be easier to view
the milky white image at a slight angle. Viewing the image at an angle is especially helpful when working with tinted and
reflective glass. If the top surface of the glass is NOT the TIN SIDE, then it is the AIR SIDE. The air side of the glass will
result in the lamp image appearing normal (violet color) (Figure 4).
ADDITIONAL OPERATING TIPS
1. If the Instrument lamp does not turn on instantly, tap the meter firmly against your hand. The lamp will illuminate
immediately. Please see Figure 6.
2. In cold temperatures, the lamp may take a few moments to warm up to full intensity.
3. Pulsing the power with the momentary power switch makes it easier to differentiate if there is a tin side glow or not.
4. Waving the lamp closer and then further away from the glass, often makes it easier to see the glowing tin side image
as well.
FIGURE 4:
Air Side (NOT Tin Side)
Dull violet lamp reflectlion
FIGURE 3:
Tin Side
Milky white reflection
FIGURE 6:

GLASS DRILL INSTRUCTION MANUAL
INSTRUCTION MANUAL
crlaurence.com
C.R. Laurence Co., Inc. •2503 E. Vernon Ave., Los Angeles, CA 90058 •1.800.421.6144 •crlaurence.com
NOVEMBER 2020
P. 5
LAMP REPLACEMENT
The TS1320 includes a custom short wave UV lamp inside the enclosure. If the lamp stops working, confirm that your
batteries are still functional. If you have replaced the batteries and installed them correctly (double-check polarity) and
the instrument is still not working, It may be necessary for you to replace the short wave UV lamp. The replacement lamp is
PART# TS1310 and is available from your dealer.
To replace the lamp, the unit off first. WARNING: YOU MUST REMOVE THE BATTERIES BEFORE SERVICING THE
INSTRUMENT. There are dangerous high voltages present inside the enclosure, and the electronics should never be
touched when powered. Use a Phillips screwdriver to remove the four screws of the enclosure. Please note, two of the
screws are located behind the battery compartment cover.
The body of the lamp is held in place by foam pieces, while the terminals are inserted into sockets In the circuit board.
Carefully pull the old lamp out of the sockets. Pay special attention to the foam pieces as you may have to peel them
away from the bulb. Leave as much of the foam in place as possible, as this helps provide shock absorption to the bulb
during use.
The replacement bulb should never be handled with bare fingers. Please use gloves when handling the replacement bulb.
The replacement bulb will be sent to you with the terminals crimped at the proper location. DO NOT MAKE ANY
ADJUSTMENTS TO THE TERMINALS, AS THEY ARE EXTREMELY FRAGILE. Carefully press the lamp terminals into
the receptacles. Fully reassemble the unit before turning power on to check the new lamp.
Remember, DO NOT stare at the lamp output directly. Either look at the image through a piece of float glass, or put on
your UV blocking safety glasses (included).
FIGURE 8: Remove batteries and four screws from enclosure
FIGURE 9: Remove the old lamp and replace with new
two
screws
two
screws

GLASS DRILL INSTRUCTION MANUAL
INSTRUCTION MANUAL
crlaurence.com
C.R. Laurence Co., Inc. •2503 E. Vernon Ave., Los Angeles, CA 90058 •1.800.421.6144 •crlaurence.com
NOVEMBER 2020
P. 6
BATTERY REPLACEMENT
If the low battery indicator illuminates, the instrument Is warning that the batteries should be replaced in the near future.
It is possible that the TS1320 product will continue to work for some time after the indicator illuminates. It is totally safe to
continue using the instrument while the low battery indicator is Illuminated. Monitor the intensity of the lamps to know the
exact time that !he batteries need replaced. The TS1320 is powered by three AAA alkaline batteries. Alkaline batteries are
required for the best performance of this device. Before replacing the batteries, be sure to turn the power off. To access
the batteries, you must first remove the rubber boot from the product. Next you can remove the battery cover on the back
side of the enclosure by pressing your thumb in the center on the battery cover and sliding the removable lid off. Replace
the batteries and Install the cover. Be sure to install the batteries correctly (polarity +/-): A battery polarity indicator is
included inside the battery compartment. Installing the batteries backwards may cause permanent damage to the lamp
and will not be covered by the product warranty. If the unit is going to be stored for more than a month, we recommend
removing the batteries during storage.
REPLACEMENT PARTS
PART# DESCRIPTION
TS1310 Replacement Lamp
TS1317 Replacement Rubber Boot
WARRANTY
The manufacturer warrants the electronics included In all models of the TS1320 to be free from defects In material and
workmanship under normal use and service as specified within the operator’s manual. The manufacturer shall repair or
replace the unit within twelve (12) months from the original date of shipment after the unit is returned lo the manufactures
factory, prepaid by the user, and the unit is disclosed lo the manufacturers satisfaction, to be thus defective. This warranty
shall not apply to any unit that has been repaired or altered other than by the manufacturer. The aforementioned
provisions do not extend the original warranty period of the unit which has been repaired or replaced by the manufacturer.
Batteries, lamps, rubber boot, and front panel interface com· potents are not covered by warranty.
The manufacturer assumes no liability for the consequential damages of any kind through the use or misuse of the TS1320
product by the purchaser or other. No other obligations or liabilities are expressed or imported. AI damage or liability claims
will be limited to an amount equal to the sale price of the TS1320, as established by the manufacturer.

GLASS DRILL INSTRUCTION MANUAL
INSTRUCTION MANUAL
crlaurence.com
C.R. Laurence Co., Inc. •2503 E. Vernon Ave., Los Angeles, CA 90058 •1.800.421.6144 •crlaurence.com
NOVEMBER 2020
P. 7
RELATED PRODUCTS
“Glass-Chek ELITE”
Identify location and type of low e
coatings as well as glass, lami & air space
thickness. Good for single, double &
triple pane windows. (Model# GC3200)
“ETEKT+
Dual Pane Low E Coating Detector
(Model# AE1601)
Digital Tin Side Detectors
(Model # TS2300)
STRENGTHENED GLASS DETECTOR”
(Model# SG2700)
Identify Strengthened/Tempered Glass
“The EDGE” Low- E Coating Detector
(Model# CM2030)
Low-E coating & Edge Deletion Detector
“LOW·E CARD” & “LOW-E CARD+”
(Model# AE2200 & AE2250)
Credit Card Size Low-E Detector
Table of contents