Cromtech AP110002 Administrator Guide

OPERATION & INSTRUCTION MANUAL
CROMTECH™ VENTILATOR FANS
Spare Parts & Service
Sales: 1300 650 659
Thank you for your selection of a CROMTECH™Ventilator Fans.
This Operation Manual explains its use, installation, checking and
maintenance. CROMMELINS suggest that you retain this manual for ready
reference regarding proper handling of CROMTECH™Ventilator Fans.

2
CROMTECH™ Operation & Instruction Manual
Thank you for purchasing a CROMTECH™ Ventilator Fans.
This manual covers the operation, safety, and parts layout for Ventilator Fans.
The CROMTECH™ Ventilator Fans are compact and portable fans that can be
operated vertical and horizontally. Designed to fit ducting these models are
single phase and 250w.
Please take a moment to familiarise yourself with the proper operation
procedures to maximise the safe and efficient use of this product.
Keep this owner’s manual at hand, so that you can refer to it at any time.
Note: Due to constant efforts to improve our products, certain procedures and
specifications are subject to change without notice.
When ordering spare parts please have handy your products model number
and serial number.
Please fill in the following blanks after checking the model number and serial
number on your product. (The location of these numbers, vary depending on
product).
MODEL NO.
SERIAL NO.

3
CROMTECH™ Operation & Instruction Manual
INDEX
Australian Warranty Information ……………………………………….………. 4
Safety and Maintenance ……………………………………………………………. 5
Model Specifications …………………………………………………………………. 6
AP110001, AP110002, AP160016, AP110020 …………………………………….… 6
AS110001 Cromtech™ Air Scrubber ……………………………………….….. 7
Operation ………………………………………………………………………….. 8
Service ………………………………………………………………………….……. 9
Maintenance ………………………………………………………………….….. 10
Parts Break down ………………………………………………………………. 11
AP110002 Cromtech™ Drymax Carpet Dryer ……………….………….. 12
Operation ………………………………………………………………………….. 13
Maintenance …………………………………………………………………….. 14
Parts Break down ………………………………………………………………. 15
AP160016 Cromtech™ Down Draft Blower ………..…………………….. 16
Operation …………………………………………………………………………. 17
Maintenance & Trouble Shooting …………………………………….. 18
Parts Break down ……………………………………………………………… 19
AP110020 Cromtech™ Multi Air Mover …………………………………… 20
Operation & Maintenance ………………………………………………… 21
Trouble Shooting .……………………………………………………………… 22
Parts Break down ……………………………………………………………… 23

4
CROMTECH™ Operation & Instruction Manual
AUSTRALIAN WARRANTY INFORMATION
1 YEAR CROMTECH™ MANUFACTURER’S WARRANTY
Cromtech™products have a 1 year manufacturer’s warranty.
WARRANTY EXPLAINED
CROMTECH™ is a registered trademark of Crommelins Machinery.
Crommelins Machinery warrants their goods against defects in materials and workmanship
under normal use and service.
The Crommelins Machinery warranty does not cover fair wear commensurate with the age
of the product, any damage caused by accident, abuse, misuse, neglect, or failure to observe
proper operating instructions or proper machinery maintenance as described in the
instruction manual.
It is the owner’s responsibility to regularly maintain a product in accordance to the owner’s
manual and only use the equipment for its designed purpose.
Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and for compensation
for any other reasonably foreseeable loss or damage. You are also entitled to have goods
repaired or replaced if the goods fail to be of acceptable quality and the failure does not
amount to a major failure.
CONSUMER ADVICE
Any claim under these warranties must be made in the warranty period from the date of
purchase of the product.
To make a claim under the warranty, you must return the product (with proof of purchase)
to the place of purchase or the closest warranty agent.
There are over 185 national authorised service/repair agents available, visit
www.crommelins.com.au for their details and locations.
Where a failure does not amount to a major failure, Crommelins Machinery is entitled to
choose between providing you with a repair, replacement, or refund. To obtain
compensation, you would need to provide documentary evidence of the loss or damage
suffered, and documentary evidence that such loss or damage was a reasonably foreseeable
consequence of a failure by Crommelins Machinery to comply with a consumer guarantee
under the Australian Consumer Law.
Crommelins Operations Pty Ltd trading as Crommelins Australia and Crommelins Machinery
Ph: (08) 9350 5588 Fax: (08) 9451 6381
PO Box 352, BENTLEY WA 6982, ABN 11 008 889 656

5
CROMTECH™ Operation & Instruction Manual
SAFETY & MAINTENANCE
To reduce the risk of fire, electric shock, or injury:
1) These products are for indoor use only.
2) Read the manual carefully and completely before attempting to operate the unit. Following the
recommendations outlined in this manual will assure years of satisfactory service from your unit
3) Improper connection of the equipment grounding conductor can result in a risk of fire, electrical
shock, or personal injury. Always use a three-wire electrical system connected to the electrical
ground. For maximum protection against electrical shock, use a circuit that is protected by
ground fault circuit interrupter. Check with a qualified electrician or service person if you are in
doubt as to whether your outlet is properly grounded.
4) Do not use this machine near fuels, grain dust, solvents, thinners, or other flammable materials.
Do not use flammables to clean this machine.
5) Do not immerse or use this unit in water. Such use may cause electric shock. To avoid electrical
shock, do not expose to rain – store it indoors only. Do not expose the unit to freezing
temperatures
6) Do not pull or carry the cord, use cord as a handle, close a door on the cord or pull cord around
sharp edges/corners. Keep cord away from heated surfaces. Do not unplug cord by pulling on it.
To unplug, grasp plug, not the cord. Do not handle plug or appliance with wet hands.
7) The fan can only be used with all safety guards attached (for safety). Do not put any objects into
moving parts.
8) Keep free of dust, lint, hair. Keep hair, loose clothing, fingers, and all parts of the body away
from moving parts.
9) Turn off appliance before; unplugging, moving, cleaning, or removing the guards.
10) Operate on a level and stable surface to prevent from falling and possible injury or damage
11) Do not drop or throw unit - Treatment of this type can cause damage to the components and
create hazardous conditions.
12) Children should not operate without parent/adult/guardian supervision. Do not play with the
appliance.
13) If the supply cord is damaged, it must be replaced by and authorised service agent or similarly
qualified electrician.
MAINTENANCE:
•Cleaning - Clean off any grease and store machine in a dry place when not in use.
•Guarantee - When used in suitable working environments, this machine has a 1 year
Cromtech warranty.
•Maintaining - Only service machine with an authorised service agent. If the supply cord is
damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified
persons to avoid a hazard.
DISPOSAL:
Do not dispose of electrical appliances in general waste, use separate collection
facilities.

6
CROMTECH™ Operation & Instruction Manual
MODEL SPECIFICATIONS
CROMTECH™AIR EQUIPMENT
MODEL
AS110001
AP110002
AP160016
AP110020
AIR SCRUBBER
DRYMAX CARPET
DRYER
DOWN DRAFT
BLOWER
MULTI AIR MOVER
Wattage
250w 250w 250w 250w
Air Flow (CFM) 500CFM 850CFM 3500CFM 4500CFM
Volts
240V - 50hz
Speed 1 Speed (1.9amp)
1 Speed
(2.1amp)
2 Speed
(1.4 & 2.0amp)
2 Speed
(3.2 & 3.6amp)
RPM
2400rpmj 1600rpm 1200 / 1400rpm 1200 / 1400rpm
Motor 0.25hp Single Phase, Electric
dB(A)
Net Weight 16kg 8.5kg 19kg 13kg
Gross Weight 17kg 9.5kg 23kg 14kg
Cord Length (mm) 4.5m 6m 6m
Product Dimensions
(LxWxH)
610x560x355mm 540x430x250mm 560x680x590mm 560x305x510mm
Package Dimensions 655x570x360mm 545x430x250mm 595x575x450mm 575x365x560mm
Warranty 1 Year Cromtech Warranty
MAIN FEATURES:
•Compact design
•High impact plastic
•Stackable
•Ducting available
AS110001
AP110002
AP110020
AP160016

7
CROMTECH™ Operation & Instruction Manual
AS110001 CROMTECH™ AIR SCRUBBER
CAUTION: Risk of electric shock. Can cause injury or death.
NOTE: Remove foam cap before use
To reduce the risk of electric shock:
•Do not expose to standing water or rain
•Connect to GFCI outlet
•Do not use an extension cord
•Unplug fan before servicing or changing filters.
•Do not block air intake or outlet. One foot
minimum distance to obstructions.
•Indoor use only
•Do not use as stool or bench
•Do not operate with damaged cord or plug.
•Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar
•coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic
area and where it will not be tripped over.
TRANSPORTING THE AIR SCRUBBER:
The Air Scrubber should be transported vertically or horizontally on the appropriate feet
located on the bottom of the unit or opposite the handle
ELECTRICAL REQUIREMENTS:
The Air Scrubber can be plugged into a grounded 15 Amp circuit. It draws 2 Amps with clean filters
and no ducting. The amp draw will decrease slightly with added ducting and as the filters load with
particulate. Due to the presence of GFCI receptacle, the Pro model must be plugged directly into a
wall outlet. No extension cords should be used.
AIR DUCTING:
A. Inlet Ducting - Occasionally the area to be filtered is difficult to access and/ or the unit
cannot be in the area. In such cases, the air can be ducted to the unit's inlet. A round 16"
diameter flexible duct can be attached to the unit inlet. It connects by placing the wire in the
duct over the duct collar lip at one location and working over it over the lip gradually. It may
be removed after use for easier transport and storage.
B. Outlet Ducting - A detachable shaped exhaust ring is supplied that will allow 10" round lay-
flat plastic duct to be attached to the Air Scrubbers outlet. Put the plastic duct end through
the inside of the ring. Roll the duct end outward so that it over-laps the outside of the ring.
Clip the ring back onto the exhaust grill.
C. Negative Air Ducting - On the Air Scrubber can be used to filter and exhaust air from a
space. When exhausting to outside the space, the space will be under a slight negative
pressure. This will help prevent airborne particles from leaving the space, because the
negative pressure will draw air in through openings in the space's exterior surfaces.
Foam Cap

8
CROMTECH™ Operation & Instruction Manual
AS110001 CROMTECH™ AIR SCRUBBER OPERATION
CAUTION: Exhausting too much air from a space with open combustion devices (e.g. furnace,
fireplace or water heater) can cause those devices to backdraft. This can contaminate the space
with potentially fatal gases.
In such cases, the Air Scrubber must be used in one of the following three ways:
A. As a filtering unit only. Exhausting no air from the space and thus causing no negative
pressure or back drafting.
B. Exhausting a very limited amount of air which does not cause back-drafting. In case B, the
open combustion devices must be thoroughly checked to guarantee that they do not
backdraft while the Air Scrubber is running.
C. Direct the outlet duct from the Air Scrubber to the room with the open combustion
device(s). This will positively pressurize the room with HEPA filtered air, thus preventing
back-drafting. As in case B, those combustion devices must be checked after the Air
Scrubber is running to guarantee that they are not back-drafting.
POWER/SPEED CONTROL:
The power/speed switch is located on the control panel. When turned on to any speed, it powers
the impeller fan. Occasionally the impeller fan may not start on low speed. If this occurs, rotate the
speed control to high speed until the impeller fan starts, then adjust it to a lower speed.
CAUTION: Do not remove HEPA filter with the unit on. Removing the top and filters while running
will expose the dangerous rotating impeller fan. Disconnect the appliance before changing filters.
RESETTABLE CIRCUIT BREAKER:
The 10 amp resettable circuit breaker protects the unit and devices connected to it. The circuit
breaker is designed to sense the total current draw through the circuit. The circuit breaker "trips"
when more than 10 amps of electrical current are drawn through the device's power cord. Should an
over-current condition occur, the Air Scrubbers on-board circuit breaker prevents nuisance visits to a
remote power junction box.
IMPORTANT: Total amperage of the Air Scrubber plus all devices plugged into the receptacle must
not exceed 12 amps. The circuit breaker will not allow for loads in excess of 12 amps, although
there is a time delay before the overloaded circuit is broken.
IMPORTANT: When the Air Scrubber is plugged into a standard wall outlet and powered the Air
Scrubber's duplex outlet is live and AC voltage present.

9
CROMTECH™ Operation & Instruction Manual
AS110001 MAINTENANCE
SERVICING:
Before each use inspect for damage, blocked inlet/outlets. When the Air Scrubber is first turned on,
check for excessive vibration. If the unit vibrates excessively or if impeller rubs on housing, turn off
the unit immediately. Have a service technician inspect the unit to locate the problem.
WARNING: Use extreme caution when changing the HEPA filter as hazardous material could be
trapped in the media. Always make sure to dispose of filters in the appropriate way. If you are
unsure of how to safely dispose of any filter-consult an industrial hygienist to ensure that all
hazardous materials are contained and disposed of properly.
AIR FILTERS:
The standard Air Scrubber HEPA System is equipped with two filters that progressively filter out
smaller particles. An optional activated carbon/potassium permanganate filter can be also added.
These filters must be checked regularly. Operating the unit with dirty filters will reduce the airflow,
but will do no harm to the unit. The unit can be run indefinitely with dirty filters.
The two standard filters used are listed below (as installed in the unit from top to bottom):
1. 25 to 30% efficient (per ASHRAE 52.1-1992), MERV-7, pleated fabric pre-filter.
2. 99.97% DOP efficient HEPA filter
FILTER REPLACEMENT
When the amber "filter change light" illuminates. It may be time to replace one or both filters.
To check airflow accurately, an airflow meter or anemometer must be used:
1. When the filter change light illuminates; remove all ducting and run on high speed. if the
filter light remains lit; replace the pre-filter and run on high again. If the light remains; it is
time to replace the HEPA filter for full 500 CFM performance.
2. Airflow on high speed with all filters clean and no ducting is slightly over 500 CFM. The unit
can be run with very dirty filters and virtually no flow without harming the unit. The
operator's decision to change filters should be based on filter cost vs. the unit's filtering
effectiveness.
If airflow is 250 CFM vs. 500 CFM, the unit will filter particles from a space at half the rate. The
operator must judge if that is acceptable. If the operator determines the filters should be changed
due to low airflow, it is most economical to change them in the following order:
1. Change the pre-filter (top) first. This is the least expensive filter. Recheck the airflow. If the
airflow is acceptable, no other filters need to be changed.
2. If the airflow is still too low, the HEPA filter must be changed. To remove the HEPA filter,
follow these steps:
A. Loosen the eight screws one revolution
B. Rotate all eight clips out of the way.
C. Remove old filter.
D. Installing the new filter is the reverse of these instructions
Optional Activated Carbon/Potassium Permanganate Filters:
Optional filters are available. They use a blend of activated carbon and potassium permanganate.
This blend removes most contaminants encountered in most filtering applications. The activated
carbon removes the heavier volatile organics while the potassium permanganate removes lower
molecular weight contaminants. This is well suited to the smoke odours present after fire damage.
AS110001 MAINTENANCE

10
CROMTECH™ Operation & Instruction Manual
The life of the media blend depends upon both the hours used and the contamination level.
Another advantage of the blended media versus activated carbon only is that part of the blend
changes colour as it loads up with contaminants. It starts out black, then turns pink, then brown, and
finally white. It is best changed when it passes the brown stage and begins to turn white. It has lost
most of its effectiveness at that point.
The filter is the same size as the pleated fabric filter. Install it in place of the pleated fabric filter.

11
CROMTECH™ Operation & Instruction Manual
AS110001 PARTS BREAK DOWN
NOTE: Remove foam cap before use.
Description
Description

12
CROMTECH™ Operation & Instruction Manual
AP110002 CROMTECH™ DRYMAX CARPET DRYER
IMPORTANT SAFETY INSTRUCTIONS:
CAUTION: Risk of electric shock. Can cause injury or death to reduce the risk of electric shock
•Do not expose to standing water or rain
•Do not use an extension cord
•Unplug fan before servicing.
•Do not block air intake or outlet. One foot minimum distance to obstructions.
INDOOR USE ONLY:
•Do not use as stool or bench
•Do not operate with damaged cord or plug.
•Do not run cord under carpeting.
•Do not cover cord with throw rugs, runners, or similar coverings.
•Do not route cord under furniture or appliances. Arrange cord away from traffic area and
where it will not be tripped over.
WARNING: Not Suitable for use with Solid-State Speed Controls

13
CROMTECH™ Operation & Instruction Manual
AP110002 OPERATION
TRANSPORTING THE DRYMAX:
The Cromtech Drymax Carpet Dryer is designed to be stacked vertically or horizontally for transport.
ELECTRICAL REQUIREMENTS:
The Carpet Dryer can be plugged directly into any standard wall receptacle. Without ducting, the
Carpet Dryer will draw 1.9 amps. Ducting will reduce amp draw. Up to 6x Carpet Dryers can be daisy
chained on a standard 15-amp branch circuit.
DUCTING
The lip on the exhaust opening of the Carpet Dryer is designed to accommodate lay flat ducting with
14” or larger diameter.
RESETTABLE CIRCUIT BREAKER
The 10 amp circuit breaker protects the unit and devices connected to it. In case of a fault, the
breaker can be reset at the Carpet Dryer control panel.
Use of multiple fans and any other connected devices must be in accordance with the National
Electric Code and any additional codes or laws required by your local government.
IMPORTANT: Total amperage of the Carpet Dryer plus all devices plugged into its convenience
receptacle is limited by the onboard circuit breaker. Excessive current will cause the circuit breaker
to trip. This may occur instantly or after a while depending on the operating conditions.
IMPORTANT: When the Carpet Dryer is plugged into a standard “powered” wall outlet the Carpet
Dryer’s duplex outlet is electrically “HOT” and AC voltage is present.

14
CROMTECH™ Operation & Instruction Manual
AP110002 MAINTENANCE
WARNING: Disconnect the unit from power before servicing or cleaning. Replace all safety grills
after servicing or cleaning
POWER CORD:
Visually inspect cord and plug head before use. If there are signs of damage or excessive wear,
discontinue use until the unit has been serviced.
CLEANING:
The housing is made of durable and washable polypropylene. When cleaning, the use of solvents is
NOT recommended. When washing inside the unit, disconnect the unit from its power source.
Protect the switch, receptacle, and circuit breaker from water intrusion. Do not spray water or
cleaning solution at motor. If motor does get wet, allow motor to dry completely before restarting. If
fan is to be washed and not used within 24 hours, allow fan to drip dry for 10 minutes and then run
for 5 minutes before storing.
IMPORTANT: Do NOT remove impeller blade from motor assembly. Doing so can cause blade to
become imbalanced upon re-assembly.
SERVICE:
CAUTION: Servicing the Cromtech Carpet Dryer with its high voltage circuitry presents a health
hazard that could result in death, serious bodily injury, and/or property damage. Disconnect the
appliance from the power supply before servicing. Only qualified service people should service this
unit.
CAUTION: If the supply cord becomes damaged, they must be replaced by the manufacturer, its
service agent or similarly qualified person to avoid a hazard.

15
CROMTECH™ Operation & Instruction Manual
AP110002 PARTS BREAK DOWN

16
CROMTECH™ Operation & Instruction Manual
AP160016 CROMTECH™ DOWN DRAFT BLOWER
WARNING: Do not stack dryers more than 4 units’ high (for
transport), Do not stack 5 units high for storage.
FOR BEST PERFORMANCE
•Keep machine clean and in good operating condition
•Have machine checked periodically by your Dealer
•Use only authorized service centres for parts or
service
•Store machine carefully in dry area
•For optimum drying performance and safety, study
and follow this manual
GROUNDING:
This appliance must be grounded. If it should malfunction or
break down, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having
an equipment-grounding conductor and grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
This appliance is for use on a nominal 240V circuit and has a ground plug (see illustration, right).
Make sure that the appliance is connected to an outlet having the same configuration as the plug.
No adaptor should be used with this
appliance.
WARNING - Improper connection of the
equipment-grounding conductor can result
in a risk of electric shock. Check with a
qualified electrician or service person if
you are in doubt as to whether the outlet
is properly grounded. Do not modify the
plug provided with the appliance - if it will
not fit the outlet, have a proper outlet
installed
by a qualified electrician.

17
CROMTECH™ Operation & Instruction Manual
AP160016 OPERATION
1. Plug in to a standard outlet with the correct voltage and amperage for the unit.
2. Place the dryer in the desired operating position.
3. Set the switch at the desired speed: low or high.
4. Check for proper operation before leaving the unit unattended.
NOTE: Do not move or carry the dryer when it is running.
10 AMP RESETTABLE CIRCUIT BREAKER
The Cromtech Down Draft Blower features a 10 amp circuit breaker that will "trip" if more than 10
amps of electrical current drawn through the cord.
OPERATING POSITIONS
The Down Draft Blower is designed to operate in multiple positions for any type of drying.
1. Tilt Back - Tilt the Blower backward on the four curved moulded legs at an angle to direct air
for elevated drying
2. Upright - Set the Blower square with the handle on the top to direct air across a room
3. Tilt Forward - Tilt the Blower forward on the "standing legs at an angle to direct airflow
along the flow in front of the dryer
4. Face Down - Set the Blower on the four curved moulded legs with the "standing legs" facing
up to direct air straight down
5. Power Pitch - The Blower is equipped with a 3° down angle leg
6. Stack for Storage - The Blower interlock and stack for easy storage and transport.

18
CROMTECH™ Operation & Instruction Manual
AP160016 MAINTENANCE & TROUBLE SHOOTING
PERIODIC MAINTENANCE:
1. Check power cord for any breaks, separations, or cuts.
2. Make sure the ground pin or grounding prong is intact or the machine will be unsafe to
operate.
TROUBLE SHOOTING (if the dryer will not be running):
1. Check electrical cord; is it firmly seated in wall outlet
2. Check if dryer circuit breaker is tripped, reset if necessary
3. Check to see if building circuit breaker is tripped.
4. If using an extension cord, make sure it is in good condition, proper gauge and firmly
connected.

19
CROMTECH™ Operation & Instruction Manual
AP160016 PARTS BREAK DOWN
(Optional)
Description

20
CROMTECH™ Operation & Instruction Manual
AP110020 CROMTECH™ MULTI AIR MOVER
WARNING To reduce the risk of fire,
electric shock, or injury:
1. Read the manual carefully and
completely before attempting to
operate the unit. This manual has
important information for the use
and safe operation of the machine.
Following the recommendations
outlined in this manual will assure
years of satisfactory service from
your unit
2. Improper connection of the
equipment grounding conductor
can result in a risk of fire, electrical
shock, or personal injury. Always
use a three-wire electrical system
connected to the electrical ground.
For maximum protection against
electrical shock, use a circuit that is
protected by a ground fault circuit
interrupter. Check with a qualified
electrician or service person if you
are in doubt as to whether your
outlet is properly grounded. Do not
use a unit with a damaged cord or
plug.
3. Machines can cause an explosion when near flammable materials and vapours. Do not use
or store this machine with or near fuels, grain dust, solvents, thinners, or other flammable
materials. Do not use flammables to clean this machine.
4. Do not immerse or use this unit in standing water. Such use may cause electrical shock. To
avoid electrical shock, do not expose the unit to rain – store it indoors only. Do not expose
the unit to freezing temperatures.
5. Do not move or carry the unit when it is turned on. Do not pull or carry by the cord, use cord
as a handle, close a door on the cord or pull cord around sharp edges or corners. Keep cord
away from heated surfaces. Do not unplug cord by pulling on it. To unplug, grasp plug, not
the cord. Do not handle plug or air mover with wet hands.
6. Do not put any objects into openings. Do not use with any opening blocked; keep free of
dust, lint, hair, and anything that may reduce air flow. Keep hair, loose clothing, fingers, and
all parts of the body away from openings and moving parts.
7. Turn off all controls before unplugging.
8. Operate unit on a level and stable surface to prevent it from falling and possible cause of
injury or damage.
9. Do not drop or throw the unit. Treatment of this type can cause damage to the components
and create hazardous conditions.
This manual suits for next models
3
Table of contents