CTs SERIES
Building on the foundation of the Crown®
Com-Tech®Series, the CTs Series offers new
flexibility and value for installed sound appli-
cations. The Com-Tech Series was the first to offer
independent selection of high- and low-impedance
operation for a specific channel, and CTs Series
amplifiers continue that tradition, with power
levels and features carefully chosen to perfectly
integrate into fixed install design requirements.
For added flexibility, the CTs Series includes both
dual-channel and multi-channel models.
All models in the CTs Series feature Crown’s new
Switching Power Supply for lighter weight, and
all models are also compatible with Harman Pro
System Architect as well as the IQ System®.
Two-channel models accept PIP2™ modules, and
also feature selectable high-pass filters and input
sensitivity for each channel.
In a profession where unplanned service calls
quickly wipe out profits, the CTs Series amplifiers
are designed to be the most reliable amplifiers you
can install.
For more details about the CrownCTs Series,
contact Crown Customer Service at 800-342-6939
or 574-294-8200. Also, visit the Crown Audio
website at www.crownaudio.com.
Specifications
Minimum Guaranteed Power: See power charts
at left.
Frequency Response (at 1 watt, 20 Hz - 20 kHz):
±0.25 dB.
Signal to Noise Ratio below rated power (20 Hz
to 20 kHz): 105 dB A-weighted.
Total Harmonic Distortion (THD) at full rated
power, from 20 Hz to 20 kHz: CTs 600/1200:
< 0.1%. CTs 2000/3000 < 0.35%.
Damping Factor: 10 Hz to 100 Hz: > 3000.
Crosstalk (below rated power, 20 Hz to 1 kHz):
> 80 dB.
Common Mode Rejection (CMR) (20 Hz to 1
kHz): 50 dB.
DC Output Offset:< ±2 mV.
Input Impedance (nominal): 10 kilohms balanced,
5 kilohms unbalanced.
Maximum Input Level: +20 dBu before input com-
pression, +32 dBu absolute maximum.
Load Impedance: (Note: Safe with all types of
loads)
CTs 600/1200
Stereo: 2/4/8/16 ohms, 70V, 100V
Bridge Mono: 4/8/16 ohms, 140V.
CTs 2000/3000
Stereo: 2/4/8/16 ohms, 70V, 100V
Bridge Mono: 4/8/16 ohms, 140V, 200V.
Features
• Switching Power Supply for reduced weight
• High power-density, with all two-channel models in
a 2U chassis
• Direct constant-voltage (70V/100V/140V/200V) or
low-impedance (2/4/8 ohm) operation
• Input sensitivity independently selectable for each
channel
• TLC protection circuitry protects the amplifier from
long-term excessive heat by subtly and dynamically
reducing the gain only when necessary
• PIP2 (Programmable Input Processor) connector
accepts accessory modules that tailor the amplifier
to suit specific applications
• Removable terminal block input connectors, with “Y”
Input Switch in the standard PIP2-BBY module
• Switchable high-pass filter for each channel provides
low-frequency roll off to eliminate step down trans-
former saturation when used in distributed systems
• Comprehensive array of indicators including Power,
Data and Bridge, along with Ready, Signal, Clip,
Thermal and Fault for each channel, provide accurate
diagnostics
• Blue Power Indicator flashes if the AC mains is
under/over voltage
• Advanced protection circuitry guards against: shorted
outputs, DC, mismatched loads, general overheating,
under/over voltage, high-frequency overloads and
internal faults
• JTs circuitry (CTs 600/1200) quickly protects output
transistors from unsafe operating conditions without
shutting the channel down
• Legendary Crown AB+B (Multi-Mode®) output
topology in the CTs 600/1200 and Class I (BCA®)
output topology in the CTs 2000/3000 offer the best
in amplifier reliability
• Continuously variable fans optimize cooling efficiency
• Three Year, No-Fault, Fully Transferable
Warranty completely protects your investment and
guarantees its specifications
CTs Series
2-channel
CTs 2000
2-ohm Dual (per ch.)
4-ohm Dual (per ch.)
8-ohm Dual (per ch.)
16-ohm Dual (per ch.)
70V Dual (per ch.)
100V Dual (per ch.)
4-ohm Bridge
8-ohm Bridge
16-ohm Bridge
140V Bridge
200V Bridge
1000W
1000W
1000W
625W
1000W
1000W
2000W
2000W
2000W
2000W
2000W
20 Hz–20 kHz
Power
20 Hz–20 kHz Power refers to maximum average
power in watts from 20 Hz to 20 kHz with 0.35% THD.
CTs 3000
2-ohm Dual (per ch.)
4-ohm Dual (per ch.)
8-ohm Dual (per ch.)
16-ohm Dual (per ch.)
70V Dual (per ch.)
100V Dual (per ch.)
4-ohm Bridge
8-ohm Bridge
16-ohm Bridge
140V Bridge
200V Bridge
1500W
1500W
1250W
625W
1500W
1500W
3000W
3000W
2500W
3000W
3000W
20 Hz–20 kHz
Power
20 Hz–20 kHz Power refers to maximum average
power in watts from 20 Hz to 20 kHz with 0.35% THD.
Crown International
1718 W. Mishawaka Rd.
Elkhart, IN 46517-9439
TEL: 574-294-8200
FAX: 574-294-8FAX
www.crownaudio.com
9/07 136317-2B
CTs Series
2-channel
Voltage Gain (at maximum level setting):
8/4 ohm operation, 1.4V sensitivity
CTs 600 35:1 (31 dB)
CTs 1200 50:1 (34 dB)
CTs 2000 63.9:1 (36 dB)
CTs 3000 71.4:1 (37 dB).
26 dB: 20:1 (26 dB).
70V operation, 1.4V sensitivity or 100V opera-
tion, 2.0V sensitivity: 50:1 (34 dB).
AC Line Voltage and Frequency Configurations
Available (±10%): 120VAC/60Hz, 230VAC/50 Hz.
Power Draw at Idle (120VAC mains):
CTs 600/1200: 24W (standby mode)
CTs 2000/3000: 35W (standby mode).
Cooling: Continuously variable speed forced air,
front-to-back airflow.
Dimensions: 19 in. (48.3 cm) W x 3.5 in. (8.9 cm)
H x 14.25 in. (36.2 cm) D.
Weight: Net, Shipping
CTs 600: 22.8 lb (10.3 kg), 27.7 lb (12.6 kg)
CTs 1200: 23.4 lb (10.6 kg), 28.3 lb (12.8 kg)
CTs 2000: 27.0 lb (12.2 kg), 32.0 lb (14.5 kg)
CTs 3000: 27.7 lb (12.6 kg), 32.7 lb (14.8 kg).
Front Panel Controls and Indicators
Bridge Mode Indicator: Yellow LED illuminates
when the rear-panel Mode Switch is set to the
“Bridge” position.
Ready Indicator: Green LED, one per channel,
illuminates when the channel is initialized and
ready to produce audio output. Indicator is off
when PIP puts the amplifier in standby mode via
the control system.
Signal Indicators: Three green LEDs per channel
indicate the amplifier’s input and output signal
levels.
Signal: input signal is above –40 dBu.
–20 dB: amplifier output is 20 dB below clipping.
–10 dB: amplifier output is 10 dB below clipping.
Clip Indicator: Red LED, one per channel, illumi-
nates when the channel’s output signal reaches the
onset of audible clipping. The Clip Indicator also
will illuminate during Thermal Level Control (TLC)
limiting or when the input compressor/limiter is
protecting the amplifier from input overload.
Thermal Indicator: Red LED, one per channel,
illuminates when the channel has shut down, or
is very near shutting down, due to thermal stress
or overload.
Fault Indicator: Red LED, one per channel, flashes
when the amplifier output channel has stopped
operating.
Data Indicator: Yellow LED indicates control data
activity (if the amplifier is equipped with an IQ-
PIP2 module, and connected to a control system).
Power Indicator: Blue LED indicates amplifier has
been turned on and AC power is available. The
LED will flash when the AC line voltage is 15%
above or 25% below the nominal rated value.
Cooling Vents: Front-to-rear forced airflow.
Power Switch: Push-on / push-off switch.
Back Panel Controls and Connectors
Power Cord Connector: Standard 15 amp IEC
inlet. Voltage is indicated above IEC inlet.
Reset Switch: Resets the circuit breaker that
protects the power supply.
Speaker Connectors: One four-pole touch-proof
terminal strip. Accepts up to 10 AWG terminal
forks.
Input Connectors: Balanced 2-pin terminal block
connector, one per channel, on the standard PIP2-
BBY module.
Channel Level Control: One 21-position detented
rotary attenuator per channel, ranging from minus
infinity (–70 dB) to 0 dB gain.
Mode Switch: Two-position switch is used to
select the amplifier’s mode of operation: Dual or
Bridge-Mono.
Highpass Filter: One 3-position switch per
channel selects between OFF, 35Hz and 70Hz
3rd-order filters.
“Y” Input Switch: When set to ON, this switch
parallels the input signals of the two channels for
use when the input signal is mono. Also can be
used to daisy-chain the signal to another amplifier.
Ventilation Grille: Front-to-rear forced airflow.
Options
PIP2 modules, including the PIP-Lite, PIP-USP3,
and PIP-USP3/CN.
Protection Systems
Thermal Level Control (TLC): If an amplifier chan-
nel starts to overheat, the TLC circuit will engage
the input compressor. By compressing the input,
the amplifier will not generate as much heat and
will have a chance to cool down.
Junction Temperature Simulation (JTS): In the
CTs 600/1200, if excess power is demanded, JTS
circuitry limits the drive level of the output devices
to a safe range, preventing damage.
Fault: The amplifier will light the Fault LED if the
amplifier output stage stops operating.
AC Under-/Over-Voltage Protection: If the AC line
voltage drops below 25% or rises above 15% of
the nominal operating voltage of the amplifier, the
amplifier’s power supply turns off and the blue
Power LED flashes. The amplifier will turn back on
when the AC line voltage returns to safe operating
levels.
Circuit Breaker: This breaker protects the ampli-
fier from excessive AC current draw.
DC Output Servo: The output servo circuit pro-
tects your drivers by eliminating DC offset, even in
the presence of very large asymmetrical signals.
In-rush Limiting: A soft-start circuit in the power
supply minimizes the amplifier’s current draw
during power-on.
Variable-speed Fan: Two continuously variable
speed fans direct the airflow through the amplifier
for cooling.
Specifications subject to change without prior notice. Latest
information available at www.crownaudio.com.
Crown, Crown Audio, Com-Tech, IQ System, BCA and Multi-
Mode are registered trademarks and PIP2 is a trademark of
Crown International. HiQnet is a trademark of Harman Inter-
national Industries, Inc. Other trademarks are the property of
their respective owners. Printed in U.S.A.
© 2007 Crown Audio®, Inc.
Crown’s Three-Year, No-Fault, Fully Transferable Warranty
Crown offers a Three-Year, No-Fault, Fully Transferable Warranty for every new Crown amplifier—an
unsurpassed industry standard. With this unprecedented No-Fault protection, your new Crown
amplifier is warranted to meet or exceed original specifications for the first three years of ownership.
During this time, if your amplifier fails, or does not perform to original specifications, it will be
repaired or replaced at our expense. About the only things not covered by this warranty are those
losses normally covered by insurance and those caused by intentional abuse. And the coverage is
transferable, should you sell your amplifier.
See your authorized Crown dealer for full warranty disclosure and details. For customers outside
of the USA, please contact your authorized Crown distributor for warranty information or call
574-294-8200.

Other manuals for CTs 1200

9

This manual suits for next models

5

Other Crown Amplifier manuals

Crown XTi 6002 User manual

Crown

Crown XTi 6002 User manual

Crown Macro-Tech MA-3600VZ User manual

Crown

Crown Macro-Tech MA-3600VZ User manual

Crown XLi 3500 User manual

Crown

Crown XLi 3500 User manual

Crown XTi 6000 User manual

Crown

Crown XTi 6000 User manual

Crown Macro-Tech 5002 VZ User manual

Crown

Crown Macro-Tech 5002 VZ User manual

Crown Macro-Tech MA-36X12 Manual

Crown

Crown Macro-Tech MA-36X12 Manual

Crown CE-1000A User manual

Crown

Crown CE-1000A User manual

Crown Power Base-2 Quick start guide

Crown

Crown Power Base-2 Quick start guide

Crown 4300 User manual

Crown

Crown 4300 User manual

Crown Micro-Tech MT-1000 Quick start guide

Crown

Crown Micro-Tech MT-1000 Quick start guide

Crown Pulse 4X300 User manual

Crown

Crown Pulse 4X300 User manual

Crown CTs 600 User manual

Crown

Crown CTs 600 User manual

Crown DSi 1000 User manual

Crown

Crown DSi 1000 User manual

Crown XTi 4000 User manual

Crown

Crown XTi 4000 User manual

Crown I-Tech 4x3500 HD User manual

Crown

Crown I-Tech 4x3500 HD User manual

Crown DC 300 User manual

Crown

Crown DC 300 User manual

Crown CTs 1200 User manual

Crown

Crown CTs 1200 User manual

Crown 28M Installation and operating instructions

Crown

Crown 28M Installation and operating instructions

Crown CH1 User manual

Crown

Crown CH1 User manual

Crown CROWN K Series User manual

Crown

Crown CROWN K Series User manual

Crown DSi-8M User manual

Crown

Crown DSi-8M User manual

Crown XLS 402 User manual

Crown

Crown XLS 402 User manual

Crown CDi 6000 User manual

Crown

Crown CDi 6000 User manual

Crown CP660 User manual

Crown

Crown CP660 User manual

Popular Amplifier manuals by other brands

Sony TA-AV571 - Integrated A/v Amplifier operating instructions

Sony

Sony TA-AV571 - Integrated A/v Amplifier operating instructions

Fiplex TXPA220 User & installation manual

Fiplex

Fiplex TXPA220 User & installation manual

AMS Neve 1081 Technical manual

AMS Neve

AMS Neve 1081 Technical manual

Outlaw Marantz AV7005 user guide

Outlaw

Outlaw Marantz AV7005 user guide

Arcam FMJ P35 user guide

Arcam

Arcam FMJ P35 user guide

Adastra A120TUD user guide

Adastra

Adastra A120TUD user guide

CyberData 11097 Operation guide

CyberData

CyberData 11097 Operation guide

Carver pm700 user manual

Carver

Carver pm700 user manual

ALLNIC AUDIO L-8000 DHT owner's manual

ALLNIC AUDIO

ALLNIC AUDIO L-8000 DHT owner's manual

AAVIK M-380 user guide

AAVIK

AAVIK M-380 user guide

Lindsay LHA Series instruction manual

Lindsay

Lindsay LHA Series instruction manual

Toshiba XB-1000 Service data

Toshiba

Toshiba XB-1000 Service data

ITC T-6241 Operation manual

ITC

ITC T-6241 Operation manual

Goldmund TELOS 250 user manual

Goldmund

Goldmund TELOS 250 user manual

AudioSource AMP 210 owner's manual

AudioSource

AudioSource AMP 210 owner's manual

ADS PQ20.2 owner's manual

ADS

ADS PQ20.2 owner's manual

Toa BG-1015 Specification sheet

Toa

Toa BG-1015 Specification sheet

Kustom Defender V50 owner's manual

Kustom

Kustom Defender V50 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.