CSafe TracSafe MAX User manual

TracSafe MAX
User Manual
Multi-use Data Logger

The TrcaSafe MAX also has integral LCD display to view the temperature status and notifications via the recessed
function buttons.The device also includes a USB port that can be used to directly download the shipment data or
configure the shipment alarm limits prior to the shipment using a PC, for users without access to a smart phone or
tablet.
Summary
①
②
③
④
⑤
⑥
① USB cap ② Light Sensor ③LCD Screen ④ Start / Stop Button ⑤ Internal Sensor ⑥ External Probe
1
⑤
②
The CSafe TracSafe MAX Shipment monitor is used to monitor and record temperature and location data associated
with temperature sensitive product shipments. The data can be viewed without disturbing the protective thermal
packaging by employing Bluetooth Low Energy technology, that allows touchless temperature checks of in-transit
shipments using a smart phone or tablet via the CSafe TracSafe app (iOS or Android). It enables direct monitoring of
the temperature-sensitive products during the shipment or storage phases and can easily identify if the tempera-
tures hava been maintained at the end destination.

Specification
1.Measurement range:
Internal temperature: -30℃~70℃
Internal humidity: 0%RH~100%RH
External temperature: -200℃~150℃
Shock: 0g~16g
Light: >80Lux
2.Accuracy arrange:
Temperature: ±0.3℃(-20℃~40℃)±0.5℃(50℃~85℃)±1℃(-100℃~150℃)±2℃(others)
Humidity: ±3%RH(25℃,20%RH~80%RH)±5%RH(others)
Shock: ±0.5g
Light: ±5%
3.Resolution: Temperature: 0.1℃, humidity: 1%RH, shock: 0.1g
4.Memory Storage Capacity: 32,000 data points (MAX)
5.Logging interval: 3min~60min
6.Start mode: Button push, immediate start, or start delay, useTracSafe APP or CSafe pc software
7.Stop mode: Button push, stop when inserted into pc, stop when memory is full,use TracSafe APP or CSafe pc
software
8.Alarm Limits: 1 high and 1 low limit for temperature/ 1 high and 1 low limit for humidity Alarm type: Single,
cumulative
9.Alarm type: Single, cumulative
10.Alarm delay time: 10s~24H
11.Connection: USB, Bluetooth
12.Battery Life / Type: 12 month operating life, Lithium replaceable battery, VCC:3.6VDC
13.Environmental Protection: IP65 (non probe version),IP54 (probed version)
14.Dimensions: 96.3 mm(L) x 47.5 mm(W)x 19 mm(H) (non probe version)
103.3mm(L)x 47.5 mm(W)x 19 mm(H) (probe version)
15.Weight: 68g
2
16.Bluetooth: Operating Frequency: 2402MHz~2480MHz
Rated Output Power: 0dBm

Operation Instructions for PC
1.Download CSafe software
(In this part, we need to add the website which can download CSafe software)
2.Configure Parameter
•Plug the device into the computer, until “USB” symbol is shown on the LCD screen.
•Using CSafe software to configure parameter:
•If users don’t need to change the default parameter, you can click “Summary” and then click “Quick Reset” to
synchronize time.
•If use need to change the parameter, you can click “Parameter”, click “Save Parameter” after configuration.
Notice:
To avoid time/time zone errors, please click Quick Reset or Save Parameters before the first use or after replacing
the battery to ensure that the local time is configured into the recorder.
3.Start Modes
•Press button:
•Press START button for 3 seconds, ▶shows on the LCD screen.
•Use CSafe APP/software to start.
Notice:
Notice:
▶symbol blinks continuously, it indicates start delay has been set.
4.Stop Modes
•Press button: Press STOP button for 3 seconds, ■shows on the LCD screen;
•Auto stop: Stop when memory is full;
•USB stop:Stop after plugging the device into computer;
•Using CSafe APP or software to stop.
Press button to stop is default option, this function can be changed if necessary.
5.Download Data
•Plug device into computer and wait until USB symbol shows on the LCD screen:
1. User can review the PDF and CSV report in the drive which is generated by the device.
2. Using CSafe software to download the data: the data will be uploaded to CSafe’s platform automatically after
downloaded via softwareIf it fails to upload data automatically, please click "Loading" to upload manually.
:
6. Reuse
•User can re-configure and start logging after stop device or export the complete data.
Notice:
The history data will be cleared about saving parameter. User can click “History” in CSafe to review the history data
if user forget to save/download data.
3

Operation Instruction for CSafe APP
1.Turn on Bluetooth
•Press START and STOP buttons simultaneously for 3 seconds until the two LED lights blink at the same time
and shows on the LCD screen.
2.Download CSafe APP
•The user can download the CSafe TracSafe APP in iOS APP store or Google Play for Android
•User needs to register according to the prompts.
3.Configuration and logging
•Click “Loggers” tab to review the device list that are within range.
•Press the stop button then the device will be moved to the top of the device list and the background would
become orange.
•Click “Config” to configure the parameters then click “Save”.
•Click “OK→” to finish configuration.
•After configuration, click the device and then click “Start” tab to start logging.
4

4.Read & download data
•Click in Loggers page to refresh the device list and click “Read data”.
•After the data has been read completely user can click “stop” to stopping logging; Click “Data” tab to review the
history data; user can download PDF and CSV reports via clicking “Download data” tab.
5.Quick operations via scanning the bar code on the device
• In “Loggers” page, click the to scan the bar code on the device and then user can start quick operations (Start,
Config, Read data)
5

Status indication
1.Button functions
Function
Start logging
Stop logging
Switching the LCD pages
Back to LCD main page
Operation
Press START button for 3s
Press STOP button simultaneously for 3s
Press START and STOP button for 3s
Press START button
Press STOP button
LED
blink 5 times
blink 5 times
(or )blink once(or twice)
(or )blink once(or twice)
red and green LED blink 5 times at the same time
2.LCD screen
① ② ③ ④
⑤
⑥
⑦⑧
⑨
⑩
① Status of logging ② MAX, AMB, MIN ③ Bluetooth ④ Battery
⑤ Temperature value ⑥ Sample # ⑦ Humidity value/total sampling points ⑧ Shock
⑨ Status of external probe ⑩ Light
6

LCD interface
R R
1. Not started 2. Start delay 3. Started 4. Stopped
R R
5. MAX 6. MIN 7. Generating reports 8. USB connected
B
R
P
#
9. Internal sensor error 10. External sensor error 11. Re-save parameters
7

Function
▶
■
Started
Stopped
No alarm
Alarm
External probe is connected.
External probe error
Bluetooth is turned on.
LCD symbols
Note:
1. Please store the device in a room temperature environment.
2. When using the device for the first time, be sure to connect the computer for parameter configuration to synchro-
nize time.
3. Please do not take out the battery when recording.
the screen again if necessary.
5. After configuration, the history data will be cleared. Please read and save the historical data of the device before
configuration.
6. To ensure humidity accuracy, please avoid contacting unstable chemical solvents or other chemical compounds,
especially avoid long-term storage or exposure to high concentration of ketene, acetone, ethanol, isopropanol,
toluene and other environments.
7. When the battery symbol on the LCD is less than two bars, please do not use it for long-distance transportation.
8. Please enable the Bluetooth function before connecting the device via TracSafe APP.
8

Factory default parameters
Default parameter
5 min
Press button to start
No start delay
Enabled
Enabled
°C
15s
60s
3s
No blinking
UTC-05: 00
Not enabled
Not enabled
Single
No delay
8°C
2°C
Not enabled
Not enabled
Items
Logging interval
Start mode
Start delay
Press button to stop
Temporary PDF
Temperature units
LCD display time
LCD main page display time
LCD other pages display time
LED blink
Time zone
Light sensor
Shock sensor
Probe type
Alarm type
Alarm delay
Temperature high limit H1
Temperature low limitL1
Humidity high limit
Humidity low limit
9
Probe : External & Internal Temperature
Device : Internal Temperature
Note

FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of t he FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
Environment.
IC Caution
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and
compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure
and compliance.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science
and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following
two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
This equipment should be installed and operated with a minumum distance of 20 cm between
the radiator and your body.
Le dispositif rencontre l'exemption des limites courantes d'évaluation dans la section 2.5 de RSS102
et la conformité à l'expostion de RSS-102 rf, utilisateurs peut obtenir l'information canadienne sur
l'exposition et la conformité de rf.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR
d’Innovation, Sciences et Développement économique
Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes :
(1) L’appareil ne doit pas produire de brouillage;
(2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionne.
Table of contents