CTI Products MCN RYB-8 User manual

MCN RYB-8 Relay Board
with Power and Termination Options
Hardware Manual
S2-60657-115
68-11206-115

Standard Limited Hardware Warranty
LIMITED WARRANTY. Equipment manufactured by CTI Products, Inc. is warranted to be free from defects in material and workmanship for a period of
ONE (1) YEAR from date of shipment to original purchaser. Under this warranty, our obligation is limited to repairing or replacing any equipment proved to
be defective by our inspection within one year of sale to the original purchaser. This warranty shall not apply to equipment which has been repaired outside
our plant in any way, so as to, in the judgment of CTI Products, Inc. affect its stability or reliability, nor which has been operated in a manner exceeding its
specifications, nor which has been altered, defaced, or damaged by lightning.
CUSTOMER REMEDIES. In the event of a defect, malfunction, or failure to conform to specifications established by the seller during the period shown,
the customer shall call CTI Products, Inc. to obtain a Return Authorization Number and return the product or module, shipping and insurance prepaid. CTI
Products, Inc., will then at its option, either repair or replace the product or module and return it, shipping prepaid, or refund the purchase price thereof. On-
site labor at the purchaser's location is not included in this warranty.
EQUIPMENT NOT MANUFACTURED BY CTI Products, Inc. Equipment not manufactured by CTI Products, Inc. is excluded from this warranty, but
is subject to the warranty provided by its manufacturer, a copy of which will be supplied to you upon specific written request.
NO OTHER WARRANTIES. The foregoing constitutes the sole and exclusive remedy of the buyer and exclusive liability of CTI Products, Inc., AND IS
IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY AS TO MERCHANTABILITY, FITNESS FOR
PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS OR ANY OTHER MATTER.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES. WITHOUT LIMITING THE FOREGOING, IN NO EVENT SHALL CTI PRODUCTS, INC.
OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, OR
OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF OR INABILITY TO USE CTI PRODUCTS, INC. EQUIPMENT BY PURCHASER OR
OTHER THIRD PARTY, WHETHER UNDER THEORY OF CONTRACT, TORT (INCLUDING NEGLIGENCE), INDEMNITY, PRODUCT
LIABILITY OR OTHERWISE, EVEN IF CTI PRODUCTS, INC. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES.
IN NO EVENT SHALL CTI PRODUCTS, INC.’S, LIABILITY EXCEED THE TOTAL AMOUNT PAID BY PURCHASER FOR THE EQUIPMENT
GIVING RISE TO SUCH LIABILITY.
CTI Products, Inc.
1211 W. Sharon Rd.
Cincinnati, OH 45240
If you have questions about this equipment, call us at:
(513) 595-5900. (8:30 to 5:00 Eastern)
Information contained in this document is subject to change without notice and does not represent a commitment on the part of CTI Products, Inc.
No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for
any purpose without the written permission of CTI Products, Inc.
Copyright 2007, CTI Products, Inc. All rights reserved.
MCN is a trademark of CTI Products, Inc. Other trademarks referenced are properties of their respective owners.
68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
1. RYB-8 RELAY BOARD...............................................................................3
1.1 INTRODUCTION...............................................................................................3
1.1.1 Related Documents..............................................................................................4
1.2 CIRCUIT DESCRIPTION ....................................................................................5
1.2.1 Relay Control Inputs E1-E8 “B” Side ................................................................5
1.2.2 Sub-Category Jumpers E1-E8 “A” Side.............................................................6
1.2.3 Adjacent Relay Drive Jumpers E17-E23.............................................................6
1.2.4 600 Ohm Termination Jumpers E9-E16..............................................................7
1.2.5 Jumper List..........................................................................................................8
1.2.6 Power Input - TB1...............................................................................................8
1.2.7 Relay Output Connections - J1 ...........................................................................9
1.2.8 Relay Input Connections - J2............................................................................10
1.3 MOUNTING AND CABLING ..............................................................................12
1.4 SPECIFICATIONS –RYB-8 RELAY BOARD.......................................................14
1.5 SCHEMATIC –RYB-8 RELAY BOARD..............................................................15
1.6 BOARD LAYOUT –RYB-8 RELAY BOARD........................................................16
2. HOT-STANDBY POWER SUPPLY OPTION ............................................17
2.1 INTRODUCTION.............................................................................................17
2.1.1 Power Distribution............................................................................................17
2.1.2 Status Indication................................................................................................17
2.1.3 Fuses..................................................................................................................18
2.1.4 Terminal Blocks ................................................................................................18
2.2 MOUNTING...................................................................................................19
2.3 SPECIFICATIONS –HOT STANDBY POWER SUPPLY OPTION..............................19
2.4 SCHEMATIC -POWER DISTRIBUTION BOARD ...................................................20
2.5 BOARD LAYOUT –POWER DISTRIBUTION BOARD.............................................21
3. PASSIVE BRIDGE BOARD ......................................................................22
3.1 INTRODUCTION.............................................................................................22
3.2 MOUNTING...................................................................................................22
i 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
This page intentionally left blank
ii 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
1. RYB-8 Relay Board
1.1 Introduction
The MCN-RYB-8 board is a relay board accessory to the MCN Monitoring and
Control Network product family.
The MCN-RYB-8 board has the following features:
•(8) DPDT Relays (Configured to switch circuit pairs).
•Hi-reliability long-life sealed relays.
•Relays rated for low-level (dry circuit) audio switching, up to 2A.
•Selectable 600 Ohm terminations for the Normally Open, Normally Closed, or
Common circuits (may be de-selected).
•LEDs to indicate which relays are active.
•Control Connector (relay coil inputs) which is pin-compatible with the MCN
IOB modules.
•25-pair telco connectors used for control inputs and relay outputs.
•Jumpers to control adjacent relays.
•Jumpers for Sub-Category strapping for MCNRCD variable status text
messages.
•Optional EIA 19” rack-mount panel available for mounting (4) MCN-RYB-8
boards.
Part Number Description
S3-60644 Basic board with no jumpers installed
S2-60694 Board with standard jumpers installed
E1-E8: B1 installed (I/O Line 1 controls relays)
B4 installed (Spare sub-category jumper, parked)
E9-E16: (2) jumpers installed in park position
(600 Ohm Termination de-selected)
S2-60508 Board with A/C jumpers installed
S2-60509 Board with B jumpers installed
S2-60510 Board with C/C jumpers installed
S2-60794 Board with A/B jumpers installed
S2-60645 Cable Assy, IOB/CIB/IIB to RYB-8, 50 Conductor, 1' Length
Note: The MCN RYB-8 Relay board is pin-compatible with the IOB module and
is fully supported for operation with it. Although it is also pin- compatible with
the CIB Comparator Interface Module (in Spectra-TAC mode only), it is not
supported for use with CIB modules. References are made within this document
to the CIB Comparator Interface Module only for completeness, especially with
the MCNRCD PC Software.
3 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
1.1.1 Related Documents
1. MCN IOB Input/Output Control Module
Part Number S2-60630
2. MCN System Manual
Part Number S2-60425
3. MCN Remote Comparator Display (MCNRCD) Manual
Part Number S2-60428
4 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
1.2 Circuit Description
The MCN-RYB-8 board has 8 identical circuits. The following will describe the
first such circuit.
Relay K1 has the following I/O bits associated with it:
J2
Pin Relay I/O Bit Relay Board
Function CIB Module
Signal IOB Mode 1
Signal
21 1 1 Input/Output VOTE 1 Input/Output 1
22 1 2 Output RECEIVE 1 input 1
20 1 3 Input/Output DISABLE 1 Input/Output 9
23 1 4 Output FAIL 1 input 9
I/O bits 1 or 3 can be used as inputs to drive the coil of the relay (see Figure 1).
1.2.1 Relay Control Inputs E1-E8 “B” Side
Each relay has its own jumper block (E1-E8) to select the input that will drive the
relay coil. Each relay can be controlled from either I/O bit 1 or 3 associated with
it, depending upon the position of the B1 or B3 jumper in jumper blocks E1-E8.
The following table shows the jumper configuration for relay K1:
J2 Pin I/O Bit Jumper
21 1 E1-B1 In (Default)
20 3 E1-B3 In
Only one jumper (E1-B1 or E1-B3) should be installed at a time.
CA-80270-100
A
B
4
3
2
1
DIS
VOTE
RX
FAIL
I/O BIT
DEFAULT POSITION
I/O BIT 1 DRIVES RELAY
ALTERNATE POSITION
I/O BIT 3 DRIVES RELAY
JUMPER POSITIONS FOR
SUB-CATEGORY JUMPERING
B4 PARKING FOR UNUSED JUMPER
B2 PARKING FOR UNUSED JUMPER
Figure 1. Input Jumpering E1-E8
Positions B2 and B4 can be used to "park" unused jumpers.
5 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
1.2.2 Sub-Category Jumpers E1-E8 “A” Side
When you use the MCN Relay Board with an MCN IOB module and the
MCNRCD PC Software, you can use the “A” side of jumper blocks E1 through
E8 to provide static sub-category status text selections. This will allow you to
specify different status text messages (On/Off, Up/Down, Main/Standby, etc. as
defined in the MCNRCD.CFG file) for different relays on the MCN-RYB-8
board.
For relay K1, the jumpering is shown in Table 1:
J2
Pin Relay I/O Bit Jumper CIB Signal IOB Mode 1
Signal MCNRCD
Bit Weight
21 1 1 E1-A1 In VOTE 1 Input/Output 1 1
22 1 2 E1-A2 In RECEIVE 1 input 1 04
20 1 3 E1-A3 In DISABLE 1 Input/Output 9 10
23 1 4 E1-A4 In FAIL 1 input 9 40
Table 1 - Sub-Category Jumpers
Since I/O bit 1 is normally used to control the relay, I/O bits 2-4 are available for
sub-category selection. Up to (8) sub-categories can be configured with these 3
bits. When a jumper is inserted, the bit is active. See the MCNRCD Software
Manual and IOB hardware manual for more details on sub-categories.
1.2.3 Adjacent Relay Drive Jumpers E17-E23
In some applications you may need to drive two relays from the same input
signal. You can use jumpers E17-E23 to connect a relay's coil to an adjacent
relay's coil.
E17 jumpers the coils for relays 1 & 2 together. E18 jumpers relays 2 & 3, and so
on.
Caution
When you insert the Adjacent Relay Drive jumpers (E17-E23), be sure that you
have only one input active (E1-E8 "B" side) for each set of relays that are
connected together.
These jumpers are normally not installed from the factory, unless a custom
configuration is ordered.
6 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
1.2.4 600 Ohm Termination Jumpers E9-E16
A selectable 600 Ohm termination is available for each relay. The termination is
used in some telephone line applications when you need to terminate an unused
phone line. Jumper blocks E9 to E16 control the terminations. You can terminate
the Normally Open, Normally Closed, or Common pair as shown in Table 2 and
Figure 2
600 Ohm Termination E9-E16 Jumpers Installed
None None (or insert in "Park" positions)
Common Pair A1 & B1
Normally Open Pair A2 & B2
Normally Closed Pair A4 & B4
Table 2 - 600 Ohm Termination Jumpering
CA-80272-100
---------------
B
A
1
12
23
34
4
---------------
---------------
TERMINATE
COMMON PAIR
TERMINATE
TERMINATE
N.O. PAIR
N.C. PAIR
B
A
1
12
23
34
4
B
A
1
12
23
34
4
---------------
B
A
1
12
23
34
4
NO TERMINATION
(PARKING FOR UNUSED JUMPERS)
Figure 2. 600 Ohm Termination Jumpering E9-E16
7 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
1.2.5 Jumper List
Jumper Controls
Relay Description
E1 1 Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E2 2 Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E3 3 Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E4 4 Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E5 5 Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E6 6 Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E7 7 Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E8 8 Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E9 1 600 Ohm Termination Selection
E10 2 600 Ohm Termination Selection
E11 3 600 Ohm Termination Selection
E12 4 600 Ohm Termination Selection
E13 5 600 Ohm Termination Selection
E14 6 600 Ohm Termination Selection
E15 7 600 Ohm Termination Selection
E16 8 600 Ohm Termination Selection
E17 1 & 2 Adjacent relay coil selection--Connects relay coils 1 & 2
E18 2 & 3 Adjacent relay coil selection--Connects relay coils 2 & 3
E19 3 & 4 Adjacent relay coil selection--Connects relay coils 3 & 4
E20 4 & 5 Adjacent relay coil selection--Connects relay coils 4 & 5
E21 5 & 6 Adjacent relay coil selection--Connects relay coils 5 & 6
E22 6 & 7 Adjacent relay coil selection--Connects relay coils 6 & 7
E23 7 & 8 Adjacent relay coil selection--Connects relay coils 7 & 8
Table 3 - Jumper Block List
1.2.6 Power Input - TB1
The board requires 12V external power at 704 mA. Power is applied through
screw terminal block TB1 as shown in Table 4.
TB1 Pin Function
1 +12V
2 +12V (can be used to daisy-chain power)
3 Ground
4 Ground (can be used to daisy-chain power)
Table 4 - Power Connections TB1
8 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
1.2.7 Relay Output Connections - J1
The relay output connections appear on a 50-pin female micro-ribbon telco-style
connector, J1. The pinouts are as follows:
J1 Pin Function
26 K1 Tip Common
1 K1 Ring Common
27 K1 Tip Normally Open (N.O.)
2 K1 Ring Normally Open (N.O.)
28 K1 Tip Normally Closed (N.C.)
3 K1 Ring Normally Closed (N.C.)
29 K2 Tip Common
4 K2 Ring Common
30 K2 Tip Normally Open (N.O.)
5 K2 Ring Normally Open (N.O.)
31 K2 Tip Normally Closed (N.C.)
6 K2 Ring Normally Closed (N.C.)
32 K3 Tip Common
7 K3 Ring Common
33 K3 Tip Normally Open (N.O.)
8 K3 Ring Normally Open (N.O.)
34 K3 Tip Normally Closed (N.C.)
9 K3 Ring Normally Closed (N.C.)
35 K4 Tip Common
10 K4 Ring Common
36 K4 Tip Normally Open (N.O.)
11 K4 Ring Normally Open (N.O.)
37 K4 Tip Normally Closed (N.C.)
12 K4 Ring Normally Closed (N.C.)
38 K5 Tip Common
13 K5 Ring Common
39 K5 Tip Normally Open (N.O.)
14 K5 Ring Normally Open (N.O.)
40 K5 Tip Normally Closed (N.C.)
15 K5 Ring Normally Closed (N.C.)
41 K6 Tip Common
16 K6 Ring Common
42 K6 Tip Normally Open (N.O.)
17 K6 Ring Normally Open (N.O.)
43 K6 Tip Normally Closed (N.C.)
18 K6 Ring Normally Closed (N.C.)
44 K7 Tip Common
19 K7 Ring Common
45 K7 Tip Normally Open (N.O.)
20 K7 Ring Normally Open (N.O.)
46 K7 Tip Normally Closed (N.C.)
21 K7 Ring Normally Closed (N.C.)
47 K8 Tip Common
22 K8 Ring Common
48 K8 Tip Normally Open (N.O.)
23 K8 Ring Normally Open (N.O.)
49 K8 Tip Normally Closed (N.C.)
24 K8 Ring Normally Closed (N.C.)
50 No Connection
25 No Connection
Table 5 - J1 Relay Contact Pinout
9 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
1.2.8 Relay Input Connections - J2
The relay input connections appear on a 50-pin female micro-ribbon telco-style
connector, J2. The relay input connector is laid out to match the MCN IOB
module pin-for-pin. J2 can be connected to the IOB module directly through a
25-pair straight-through male to male cable.
Since the MCN CIB module was originally set up to match the Digitac P805
pinout, the signals are a bit scrambled. For convenience, the pinouts are as shown
in two tables, the first sorted by relay and function, and the second sorted by pin
number. The corresponding signal names for the CIB and IOB modules are also
shown.
J2
Pin Relay I/O Bit Relay Board
Function CIB
Module
Signal
IOB Mode 1 Signal
21 1 1 Input/Output VOTE 1 Input/Output 1
22 1 2 Output RECEIVE 1 Input 1
20 1 3 Input/Output DISABLE 1 Input/Output 9
23 1 4 Output FAIL 1 Input 9
46 2 1 Input/Output VOTE 2 Input/Output 2
47 2 2 Output RECEIVE 2 Input 2
45 2 3 Input/Output DISABLE 2 Input/Output 10
48 2 4 Output FAIL 2 Input 10
15 3 1 Input/Output VOTE 3 Input/Output 3
16 3 2 Output RECEIVE 3 Input 3
14 3 3 Input/Output DISABLE 3 Input/Output 11
17 3 4 Output FAIL 3 Input 11
40 4 1 Input/Output VOTE 4 Input/Output 4
41 4 2 Output RECEIVE 4 Input 4
39 4 3 Input/Output DISABLE 4 Input/Output 12
42 4 4 Output FAIL 4 Input 12
9 5 1 Input/Output VOTE 5 Input/Output 5
10 5 2 Output RECEIVE 5 Input 5
8 5 3 Input/Output DISABLE 5 Input/Output 13
11 5 4 Output FAIL 5 Input 13
34 6 1 Input/Output VOTE 6 Input/Output 6
35 6 2 Output RECEIVE 6 Input 6
33 6 3 Input/Output DISABLE 6 Input/Output 14
36 6 4 Output FAIL 6 Input 14
3 7 1 Input/Output VOTE 7 Input/Output 7
4 7 2 Output RECEIVE 7 Input 7
2 7 3 Input/Output DISABLE 7 Input/Output 15
5 7 4 Output FAIL 7 Input 15
28 8 1 Input/Output VOTE 8 Input/Output 8
29 8 2 Output RECEIVE 8 Input 8
27 8 3 Input/Output DISABLE 8 Input/Output 16
30 8 4 Output FAIL 8 Input 16
1 Common Ground Ground Ground
Table 6 - Relay Inputs Connector J2 Pinout - Sorted by Relay & Function
10 68-11206-115

CTI Products, Inc. MCN RYB-8 Relay Board Manual
J2
Pin Relay I/O Bit Relay Board
Function CIB Module
Signal IOB Mode 1
Signal
26
1 Common Ground Ground Ground
27 8 3 Input/Output DISABLE 8 Input/Output 16
2 7 3 Input/Output DISABLE 7 Input/Output 15
28 8 1 Input/Output VOTE 8 Input/Output 8
3 7 1 Input/Output VOTE 7 Input/Output 7
29 8 2 Output RECEIVE 8 Input 8
4 7 2 Output RECEIVE 7 Input 7
30 8 4 Output FAIL 8 Input 16
5 7 4 Output FAIL 7 Input 15
31
6
32
7
33 6 3 Input/Output DISABLE 6 Input/Output 14
8 5 3 Input/Output DISABLE 5 Input/Output 13
34 6 1 Input/Output VOTE 6 Input/Output 6
9 5 1 Input/Output VOTE 5 Input/Output 5
35 6 2 Output RECEIVE 6 Input 6
10 5 2 Output RECEIVE 5 Input 5
36 6 4 Output FAIL 6 Input 14
11 5 4 Output FAIL 5 Input 13
37
12
38
13
39 4 3 Input/Output DISABLE 4 Input/Output 12
14 3 3 Input/Output DISABLE 3 Input/Output 11
40 4 1 Input/Output VOTE 4 Input/Output 4
15 3 1 Input/Output VOTE 3 Input/Output 3
41 4 2 Output RECEIVE 4 Input 4
16 3 2 Output RECEIVE 3 Input 3
42 4 4 Output FAIL 4 Input 12
17 3 4 Output FAIL 3 Input 11
43
18
44
19
45 2 3 Input/Output DISABLE 2 Input/Output 10
20 1 3 Input/Output DISABLE 1 Input/Output 9
46 2 1 Input/Output VOTE 2 Input/Output 2
21 1 1 Input/Output VOTE 1 Input/Output 1
47 2 2 Output RECEIVE 2 Input 2
22 1 2 Output RECEIVE 1 Input 1
48 2 4 Output FAIL 2 Input 10
23 1 4 Output FAIL 1 Input 9
49
24
50
25
Table 7 - Relay Inputs Connector J2 Pinout - Sorted by Pin Number
11 68-11206-115

MCN RYB-8 Relay Board Manual CTI Products, Inc.
1.3 Mounting and Cabling
The following options are available for the MCN-RYB-8 Relay Board:
S2-60646 Relay Board quad rack-mounting panel
S2-60645 Ribbon Cable assembly for CIB or IOB to Relay Board
(25-pair)
The Mounting Panel mounts in an EIA 19” rack. It can hold 4 MCN RYB-8
boards. It has snap-in standoffs for board mounting and includes tie-points for
use with cable ties. It is 10.5” high (6 Rack Units).
Figure 3 shows a view of the Mounting Panel from the front side of the equipment
rack. Since the Relay Boards are mounted to the opposite side, they are shown as
if the panel and boards were transparent. This figure also shows the ribbon cable
used to connect the relay boards with an IOB or CIB module.
CA-80267-101
J1
J2
J1
J2
J1
J2
26
1
30
5
35
10
40
15
45
20
50
25
J2
RESET
DC IN
OPTION
IN
OUT
NETWORK
PRODUCTS,INC.
MODULEGROUP
1
2
3
4
ON
PWR
ACT
ERR
RESET
DCIN
OPTION
IN
OUT
NETWORK
PRODUCTS, INC.
MODULE
GROUP
123
4
ON
PWR
ACT
ERR
RESET
DC IN
OPTION
IN
OUT
NETWORK
PRODUCTS, INC.
MODULE
GROUP
1
2
34
ON
PWR
ACT
ERR
RESET
DC IN
OPTION
IN
OUT
NETWORK
PRODUCTS, INC.
MODULEGROUP
1
2
34
ON
PWR
ACT
ERR
Products, Inc.
84-11194-100
10-14-96
COPYRIGHT1996
MCN-RYB
12V
GND
1
4
++
--
TB1
K1
K2
K3
K4
K5
K6
K7
K8
Products, Inc.
84-11194-100
10-14-96
COPYRIGHT1996
MCN-RYB
12V
GND
1
4
++
--
TB1
K1
K2
K3
K4
K5
K6
K7
K8
Products, Inc.
84-11194-100
10-14-96
COPYRIGHT1996
MCN-RYB
12V
GND
1
4
++
--
TB1
K1
K2
K3
K4
K5
K6
K7
K8
Products, Inc.
84-11194-100
10-14-96
COPYRIGHT1996
MCN-RYB
12V
GND
1
4
++
--
TB1
K1
K2
K3
K4
K5
K6
K7
K8
PANELS MAY BE MOUNTED ADJACENT.
1 RACK UNIT
6 RACK UNITS
S2-60435 MCN RACK MOUNT KIT
QUAD SIZE A
J1
26
1
30
5
35
10
40
15
45
20
50
25
26
1
30
5
35
10
40
15
45
20
50
25
26
1
30
5
35
10
40
15
45
20
50
25
261
30
5
35
10
40
15
45
20
50
25
261
305
35
10
40
15
45
20
50
25
261
305
35
10
40
15
45
20
50
25
261
30
5
35
10
40
15
45
20
50
25
NOTE: MOUNTING PLATES SHOWN SEPARATED FOR CLARITY,
Figure 3. Relay Mounting Panel
12 68-11206-115

MCN RYB-8 Relay Board Manual CTI Products, Inc.
CA-80274-100
R
VELCRO STRAP
CIB OR IOB MODULE
CABLE TIE HOLE
AMP
Figure 4. Relay Mounting Panel – Side View
13 68-11206-115

MCN RYB-8 Relay Board Manual CTI Products, Inc.
1.4 Specifications – RYB-8 Relay Board
Relay Circuits 8, DPDT (Dual Form C), Sealed
Relay Type MIL-R-39016/6
Contact Type Gold Plated over Hardened Silver;
Stationary contacts are bifurcated
Contact rating and life
expectancy 0.5 A @ 28VDC Resistive 500,000 Operations
1.0 A @ 28VDC Resistive 250,000 Operations
2.0 A @ 28VDC Resistive 100,000 Operations
3.0 A @ 28VDC Resistive 50,000 Operations
0.16 A @ 28VDC Lamp 10,000 Operations
30 uA @ 50 mVDC Low Level 1,000,000 Operations
Relays which are used for intermediate and high-level (above
.5A and/or 28 volts), inductive, or lamp service will not be
suitable for low-level operation.
Relay Coil Load Active low
88 mA max. @12VDC
110 mA max. @15VDC
Operate & Release Time 4.0 ms max.
with 12 VDC supply and contact load of 10 mA @ 6VDC
Supply Voltage 12 VDC Nominal (10-15 VDC)
Supply Current
(all 8 relays activated) 704 mA max. @12VDC
880 mA max. @15VDC
Relay Control (Input)
Connector 50-pin Female Micro-ribbon AMP connector
(TELCO 25-pair style)
Relay Output (Contact)
Connector) 50-pin Female Micro-ribbon AMP connector
(TELCO 25-pair style) with Velcro cable clamp
Optional telephone line
terminations: 620 Ohm 1/4 W 5%
Power Connector: 4-pin screw terminal strip, accepts #24 to #14 AWG wire.
Fuse AGC 1A
PCB Flammability Rating: 94V-0
Temperature Rating -25 to +65 Degrees C
Size 7.5”H x 3.75”W x 2.5”D (mounted, with connectors seated)
14 68-11206-115

MCN RYB-8 Relay Board Manual CTI Products, Inc.
1
.5 Schematic – RYB-8 Relay Board
Title
Product
Drawn By
Date
Date
Sheet
Drawing no.
File Name
Of
Approved
The information on this document
is PROPRIETARY to
and may only be used
for the purpose of installation
and maintenance of
This document MAY NOT BE COPIED
in
this product.
whole or in part without express
written permission
PRODUCTS, INC.
of CTI PRODUCTS, INC.
CTI PRODUCTS, INC.
MH1 MH2 MH3 MH4 MH5 MH6
---------------
TERM
NONE
COMMON
N.O.
N.C.
E9-E16
OUT
600? TERMINATIONS
A1+B1 IN
A2+B2 IN
A4+B4 IN
B
A
1
12
23
34
4
---------------
B
A
1
12
23
34
4
---------------
B
A
1
12
23
34
4
---------------
B
A
1
12
23
34
4
---------------
B
A
1
12
23
34
4
---------------
B
A
1
12
23
34
4
---------------
B
A
1
12
23
34
4
---------------
B
A
1
12
23
34
4
J1
D1
D2
D4
D5
D6
D7
D8
TB1
F6
K1
K2
K3
K4
K5
K6
K7
K8
E1
E3
E5
E7
E8
E6
E4
E2
R1
LD1
LD2
R2
E17
E18
E19
E20
E21
E22
E23
R3
R4
R5
R6
R7
R8
LD3
LD4
LD5
LD6
LD7
LD8
J2
J2
J2
J2
J2
J2
J2
J2
J2
J2
R9
R10
R11
R12
R13
R14
R15
R16
E9
E10
E11
E12
E13
E14
E15
E16
1
2
3
4
5
26
27
28
29
30
6
7
8
9
10
31
32
33
34
35
11
12
13
14
15
36
37
38
39
40
16
17
18
19
20
41
42
43
44
45
21
22
23
24
25
46
47
48
49
50
1
2
3
4
36
8
1
5
4
2
7
36
8
1
5
4
2
7
36
8
1
5
4
2
7
36
8
1
5
4
2
7
36
8
1
5
4
2
7
36
8
1
5
4
2
7
36
8
1
5
4
2
7
36
8
1
5
4
2
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
1 1
RSC
DRG
MCRY.FSH
CA-11194-100
MCN RELAY BOARD
84-11194-100 MCN-RYB-8
10-14-96
10-14-96
D3
+12V
+12V
GND
GND
AB
1
2
3
4
AB
AB
AB
A
A
A
A
B
B
B
B
1
2
3
4
A
A
A
A
B
B
B
B
1
2
3
4
A
A
A
A
B
B
B
B
1
2
3
4
A
A
A
A
B
B
B
B
4
3
2
1
A
A
A
A
B
B
B
B
1
2
3
4
AB
AB
AB
AB
1
2
3
4
AB
AB
AB
AB
1
2
3
4
2.7K
2.7K
2.7K
2.7K
2.7K
2.7K
2.7K
2.7K
DIS
VOTE
RX
FAIL
DIS
VOTE
RX
FAIL
DIS
VOTE
RX
FAIL
MON 1-8
DIS
VOTE
RX
FAIL
DIS
VOTE
RX
FAIL
DIS
VOTE
RX
FAIL
DIS
VOTE
RX
FAIL
DIS
VOTE
RX
FAIL
600?
600?
600?
600?
600?
600?
600?
600?
15 68-11206-115

MCN RYB-8 Relay Board Manual CTI Products, Inc.
1.6 Board Layout – RYB-8 Relay Board
CB-11194.100
16 68-11206-115

MCN RYB-8 Relay Board Manual CTI Products, Inc.
2. Hot-Standby Power Supply Option
2.1 Introduction
The Hot-Standby Power Supply Option is a redundant 12Vdc supply to power the
relay coils of the RYB-8 Relay Boards. This option consists of dual 100/240Vac
to 12Vdc Power Supplies (81-11665), a Relay Power Distribution Board (S3-
61193), and mounting hardware. A single (non-redundant) Power Supply is also
available. For this option, the information in Section 5.1 should be ignored.
Part Number Description
S2-61084 Hot-Standby Power Supply Option
S2-61390 Hot-Standby Power Supply Option with Rack Panel
S2-61240 Single Power Supply Option
S2-61117 Single Power Supply Option with Rack Panel
2.1.1 Power Distribution
The outputs from the redundant power supplies are independently connected to
inputs on the Relay Power Distribution Board. Each supply input on this board is
separately fused with an automotive style fuse, and has an “OK” and “FAIL”
LED indicator. When the input supply is present (and the input fuse is intact), the
corresponding green “OK” LED is lit. If either input supply is not present, or the
fuse is blown, the green “OK” LED for that input is turned off, and the red
“FAIL” LED is lit. In addition, an on-board buzzer sounds when either supply
input is not present, or if any of the input (F5, F6) or output (F1 – F4) fuses are
blown. The buzzer may be disabled by moving Jumper E4 to the “OFF” position.
The Relay Power Distribution Board passes the supply current from the input
supplies to four outputs (one for each relay board on the mounting panel). Each
supply output is separately fused, and has an “OK” and “FAIL” LED indicator.
When the output supply is present (and the output fuse is intact), the
corresponding green “OK” LED is lit. If an output supply is not present, or the
fuse is blown, the green “OK” LED for that output is turned off, and the red
“FAIL” LED is lit.
2.1.2 Status Indication
Three status signals are available to inform monitoring equipment if the redundant
power supplies are functioning or if any fuses are blown. The three status signals
are driven from solid state relays, with an output rating of 60V, and protected
with 0.5A fuses. (These fuses are non-field replaceable, since they are soldered.)
These signals can either be referenced to the GND signal by installing the
appropriate jumper, or isolated by removing the jumper. Table 11 lists the
terminal connections for these signals and jumpers for referencing to GND.
17 68-11206-115

MCN RYB-8 Relay Board Manual CTI Products, Inc.
2.1.3 Fuses Table 8 lists field replaceable fuses for the Relay Power Distribution Board.
Fuse
Designation CTI
Part Number
Description
F1, F2, F3, F4 65-11820 Fuse 1A 60V Fast Blow GMT Indicating
F5, F6 65-11851 Fuse 4A 32V Fast Blow Auto Mini
Table 8 – Fuses for Relay Power Distribution Board
2.1.4 Terminal Blocks
2.1.4.1 TB1 – TB4: Supply Outputs
Signal TB1 – TB4
Terminal Description
+12Vdc 1 Fused Supply Output Voltage
GND 2 Ground Reference
Table 9 – TB1 – TB4 Terminal Blocks
2.1.4.2 TB5 – TB6: Supply Inputs
Signal TB5 – TB6
Terminal Description
+12Vdc 1 Supply Input Voltage
GND 2 Ground Reference
Table 10 – TB5 – TB6 Terminal Blocks
2.1.4.3 TB7 - Status Output Signals
Signal TB7
Terminal GND
Ref
Jumper
Description
GND 1 Ground Reference
ALRM_FUSE- 2 E3 Relay contact closes if either input supply is
ALRM_FUSE+ 3 not present, or if any fuse (F1 – F6) is blown.
PWRB_OK- 4 E2 Relay contact closes if the input supply is
PWRB_OK+ 5 present and Fuse F6 is OK.
PWRA_OK- 6 E1 Relay contact closes if the input supply is
PWRA_OK+ 7 present and Fuse F5 is OK.
Table 11 – TB7 Terminal Block
18 68-11206-115
Table of contents