Ed. 0121 - 70702580 REV01 Silea - Pre-installation
Silea
MIXER
Pre-installation and installation manual
SILEA 20
SILEA 30

2
This product has been designed with the utmost care and
has undergone rigorous tests in our laboratories and for this
reason we guarantee its absolute safety and functionality.
The installation must be carried out by professionally
qualied staff, that can take responsibility for the installation
and guarantee the best safe operating conditions.
Before the installation, read the content of this manual
carefully: it contains important information regarding
product assembly and safety regulations.
Technical service
The Dealer can solve any technical problem regarding
installation.
Do not hesitate to contact him in case of doubt.
ContentsIntroduction
1CHECKS BEFORE PURCHASING......................................3
2TECHNICAL SPECIFICATIONS...........................................5
3INSTALLATION............................................................................7
Safety instructions.....................................................................................7
Symbols applied to the machine.....................................................8
Transport .........................................................................................................9
Preliminary operations............................................................................9
Positioning .....................................................................................................9
Serial number plate reading ...............................................................10
Electrical connection...............................................................................11
Wiring diagrams..........................................................................................13
4FINAL OPERATIONS..................................................................18
Checking the installation is correct................................................18
The company cannot be held liable for any print or
transcription errors, reserving the right to make changes
where deemed suitable without prior notice.
Partial reproduction without the Manufacturer's consent
is prohibited. Measurements are purely indicative and not
binding.
The original language used to prepare this manual is English:
the Manufacturer is not responsible for any translation/
interpretation or print errors.
CUPPONE 1963
Cuppone F.lli S.r.l.
Via Sile, 36
31057 Silea (TV) - ITALY
T +39 0422 361143
F +39 0422 360993
info@cuppone.com - www.cuppone.com

3
Ed. 0121 - 70702580 REV01 Silea - Pre-installation
min.
500 mm
( in. 19,7)
Max 35°C
Max 70% Min 5°C
Max 104°F
Min 41°C
20K
Fig. 1
Fig. 2
Before purchasing the product and installing it, check the
following conditions, necessary for the correct installation,
operation and maintenance of the product.
A Transport (Owner’s inspection)
√Make sure that, on the day when you receive the
product or it is installed:
•Fig. 1 lifting equipment is available that can handle
the appliance safely (check weight and dimensions in
the following pages), together with staff qualified to
carry out this operation;
•personal protection equipment is available (e.g. safety
shoes, gloves, etc.)
B Installation room (Owner’s inspection)
√Make sure that:
•the floor of the installation room is fireproof, perfectly
flat and capable of withstanding the weight of the
appliance;
•Fig. 2 the installation room:
•is dedicated and suitable to cooking food;
•has adequate air ventilation;
•complies with the current regulations on health
and safety and systems in the workplace;
•is protected from the weather;
•has a maximum temperature of between +5° (41°F)
and +35°C (104°F);
•has a maximum humidity of 70%.
•the appliance easily passes through doorways;
•Fig. 2 there are NO other sources of heat (i.e. grills,
fryers, etc.), highly flammable substances or fuels
(i.e. gasoline, petrol, bottles of alcohol, etc...) in the
vicinity of the appliance. It is absolutely necessary to
comply with the minimum safety distances between
the product and other flammable equipment or
materials. The distances indicated must be increased
in case of objects in heat-sensitive materials.
1CHECKS BEFORE PURCHASING

4
D Electrical connection (qualied electrician’s inspection)
√For a correct connection during the installation:
•provide a socket connecting to the electrical network near the
product.
•machines have the power cable already installed; a plug
(not supplied) must be tted to it of suitable capacity.
This operation must be carried out by qualified personnel.
•check that the systems in the room comply with the legal
provisions in force in the country of use and meet the
specifications on the serial number plate. For a correct electrical
connection, the appliance must:
•be included in an equipotential system in compliance
with the legislation in force. This connection must be made
between the various devices with the terminal marked
with the equipotential symbol . The cable must have
a maximum cross-section of 10 mm2(in compliance with
IEC EN 60335-2-42:2003-09) and must be yellow-green;
•must be grounded to the mains (green-yellow wire);
•must be connected to a circuit breaker in compliance with
the regulations in force (0.03A A type);
•must be connected to an omnipolar circuit breaker
allowing complete disconnection in overvoltage III category
conditions.
Electrical data
Model
SILEA
Supply
VkW Average
consumption
kW/h
Absorbed
current
A
Cable type*
n x mm2
Cust. panel
prot.
nxA
20
single-phase 230V 50/60Hz 0.75 0.45 3.3 3x1,5 2x16
three-phase 3x230V50/60Hz 0.75 0.45 1.9 4x1,5 3x16
three-phase 3x400V+N 50/60Hz 0.75 0.45 1.1 5x1,5 4x16
30
single-phase 230V 50/60Hz 1.1 0.66 4.8 3x1,5 2x16
three-phase 3x230V50/60Hz 1.1 0.66 1.8 4x1,5 3x16
three-phase 3x400V+N 50/60Hz 1.1 0.66 2.6 5x1,5 4x16
single-phase 208v 50-60Hz 1.1 0.66 5.3 3xAWG16 3x16
three-phase 3x208V50/60Hz 1.9 1.14 5.3 4xAWG16 4x16
Checks before purchasing

5
Ed. 0121 - 70702580 REV01 Silea - Pre-installation
20K
6
1
5
2
3
410
20K
7
8
9
BA
MADE IN ITAL
Y
Mod.SIL/30KR - C5 - CP
VOL
T
AC
3-400-50HZ
KW
2,1
2020
S/NSIL30KRC5CP 20 01 0129
Fig. 3
2TECHNICAL DATA
The main parts of the machine are:
1 Protection grille: prevents you from inserting your hands into the
bowl while the cycle is in progress; if the protection is lifted during
mixing, the movement of both the spiral and the bowl is stopped.
2 Bowl
3 Control panel
4 Wheel with brake
5 Wheel without brake
6 Power cable
7 Equipotential terminal
8Dough-breaking rod
9Spiral
10 Shows the correct direction of rotation of the bowl
Control panel
ASTOP button: stops the rotation of both the spiral and the bowl
BSTART button: starts the rotation of both the spiral and the bowl

6
810mm (31.89 in.)
850mm (33.46) 480mm (18.9)
810mm (31.89 in.)
705mm (27.76) 380mm (14.96)
Technical specifications mixer SILEA/20
mixer weight 80 kg [176,3 lb]
weight of packaging + mixer 88 kg [194 lb]
mixer packaging measurements 400 x 740 x 950 mm
[15.75 x 29.13 x 37.4”]
finished dough 20 kg [44 lbs]
RPM
(revolutions per minute)
mixing bowl 16 RPM
spiral 110 RPM
bowl diameter 360 mm [14.17 inc.]
bowl height 240 mm [9.45 inc.]
bowl capacity 24.43 litres [6.4 gal.]
bowl diameter 450 mm [17.72 inc.]
bowl height 260 mm [10.24 inc.]
bowl capacity 41.35 litres [11 gal.]
RPM
(revolutions per minute)
mixing bowl 16 RPM
spiral 88 RPM
Technical specifications mixer SILEA/30
mixer weight 103 kg [227 lb]
weight of packaging + mixer 114 kg [251,3 lb]
mixer packaging measurements 490 x 920 x 950 mm
[19.29 x 36.22 x 37.4”]
finished dough 30 kg [66.14 lbs]

7
Ed. 0121 - 70702580 REV01 Silea - Pre-installation
Safety instructions
•Read this guide carefully before installing the
appliance, and keep it with care in an accessible
place for any future consultation by the various
operators.
•Moreover, the manual must always accompany
the product through its life, even in case of
transfer.
•Before any movement or installation, check
that the room is suitable and systems comply
with the installation country standards and the
specifications indicated on the appliance rating
plate.
•All installation, assembly and non-routine
maintenance operations must be performed
exclusively by qualified technicians that are
authorised by the Manufacturer, in compliance
with the regulations in force in the user country,
and with the regulations on systems and work
safety.
•Before performing any installation or maintenance,
disconnect the electricity supply.
•Unauthorised actions, tampering or modifications
that do not follow the information provided in
this manual can cause damages, injuries or fatal
accidents and null and void the warranty.
•It is forbidden to install the product in
environments at risk of explosion.
•Installation or maintenance that fails to comply
with the instructions in this manual may cause
damage, injury or fatal accidents.
•Do not obstruct the ventilation and exhaust
holes of this or other equipment.
•Persons not involved with the appliance
installation may not pass through or stand in the
work area during appliance assembly.
•The serial plate provides important technical
information. This is vital in case of a request for
maintenance or repair of the equipment: please
do not remove, damage or modify it.
•These appliances are intended to be used
for commercial applications, for example in
restaurant kitchens, canteens, hospitals and
commercial companies such as bakeries,
butcher shops, etc., but not for the continuous
and mass production of food.
•To avoid risks, if the power cable is damaged,
it must be replaced by the Retailer, its service
agent or qualified personnel.
•Failure to follow these regulations may cause
damage or even fatal injury, subsequently
invalidating the guarantee and relieving the
Manufacturer of all liability.
3INSTALLATION
Symbols used in the manual and on
the labels applied to the machine
Indicates that caution is required when performing
an operation described in a paragraph that bears this
symbol. The symbol also indicates that maximum
operator awareness is required in order to avoid
unwanted or dangerous consequences
Reference to another chapter where the subject is
dealt with in more detail.
Manufacturer’s tip
Indicates that the surfaces marked with this symbol
may be hot and must therefore be touched carefully
Dangerous voltage
The symbol identifies the terminals which,
connected to each other, carry the various parts
of a device or system to the same potential (not
necessarily the earth potential)
Indicates that it is necessary to read carefully
the paragraph marked with this symbol before
installing, using and maintaining the equipment
The company cannot be held liable for any print or
transcription errors, reserving the right to make changes
where deemed suitable without prior notice.
Partial reproduction without the Manufacturer's consent
is prohibited. Measurements are purely indicative and not
binding.
The original language used to prepare this manual is English:
the Manufacturer is not responsible for any translation/
interpretation or print errors.

8
Installation
Symbols applied to the machine
Risk of
electrocution
Equipotential
terminal
Hazard due to
moving parts
20K
MADE IN ITALY
Mod. SIL/30KR - C5 - CP
VOLT
AC
3-400-50HZ
KW
2,1
2020
S/N SIL30KRC5CP 20 01 0129
Notes

9
Ed. 0121 - 70702580 REV01 Silea - Pre-installation
20K
20K
H2O
min.
500 mm
( in. 19,7)
20K
Fig. 4 Fig. 5
Fig. 6
Transport
Fig. 4
Fitted with personal protection equipment, transport the
appliance to the installation location.
Use suitable equipment, capable of dealing with its weight:
persons not involved with the appliance installation may not
pass through or stand in the work area during the appliance
assembly.
During the transport, pay particular attention to passing
through openings and/or doors.
Preliminary operations
Fig. 5
Carefully remove the protective film.
If any glue residue is left on the surfaces, remove it with soapy
water but without any corrosive or abrasive products or sharp
or pointed instruments.
Check that all the parts making up the product are in
good condition and without any faults or breakages, if
that is not the case, contact the Dealer for the
procedures to follow.
Positioning
Fig. 6
Install the appliance in a room:
•dedicated and suitable to the cooking of food;
•having adequate air ventilation;
•containing no flammable or explosive elements;
•that complies with the current regulations on health and
safety and systems in your country;
•is protected from the weather;
•has a maximum temperature of between +5° (41°F) and
+35°C (95°F);
•has a maximum humidity of 70%.
Installation
To reduce the risk of a fire,
comply with the stated
minimum distances
and install the appliance in
reproof environments that are
not at risk of explosion.
The floor of the installation room
must have a surface reproof
finish too.

10
Fig. 7
20K
MADE INITAL
Y
Mod.SIL/30KR-C5 -CP
VOLT
AC
3-400-50HZ
KW
2,1
2020
S/NSIL30KRC5CP20010129
MADE IN ITALY
Mod. SIL/30KR - C5 - CP
VOLT AC 3-400-50HZ KW 2,1
2020
S/N SIL30KRC5CP 20 01 0129
Installation
Serial number plate reading
Fig. 7
The serial number is on the back of the appliance.
It provides important technical information that is vital in case
of a request for maintenance or repair of the appliance: please
do not remove, damage or modify it.
Model
Electrical parameters
Absorption
Year of production
Serial number

11
Ed. 0121 - 70702580 REV01 Silea - Pre-installation
A
20K
N:
F - R - S - T...L:
MADE IN ITAL
Y
Mod.SIL/30KR - C5 - CP
VOLT
AC
3-400-50HZ
KW
2,1
2020
S/N SIL30KRC5CP 20 01 0129
AC 3 N400
AC 3 230
AC 230
AC 208
AC 3 208
L1
L1
L2
L2
L3
N
N
T
S
R
F
T
S
R
Fig. 8
Electrical connection
The electrical connection must be carried out
exclusively by qualified personnel after reading the
safety warnings at the beginning of the manual.
Before installing the appliance, check that systems
comply with the regulations in force in the country
where it is going to be used and with the
specications indicated on the appliance rating plate
on the LH side of the product.
•machines have the power cable already installed; a plug
(not supplied) must be tted to it of suitable capacity.
This operation must be carried out by qualified personnel.
For a correct electrical connection, the appliance must:
•be included in an equipotential system Fig. 10 in
compliance with the legislation in force. This connection
must be made between the various devices with the terminal
marked with the equipotential symbol . The cable must
have a maximum cross-section of 10 mm2(in compliance
with IEC EN 60335-2-42:2003-09) and must be yellow-green;
•must be grounded to the mains (green-yellow wire);
•must be connected to a circuit breaker in compliance with
the regulations in force (0.03A A type);
•must be connected to an omnipolar circuit breaker
allowing complete disconnection in overvoltage III category
conditions.
The Manufacturer accepts no liability for failure to comply with
the above.
If required, the cable must be replaced by the Dealer
or its technical service or by a person with similar
qualifications to prevent any risk.
Installation
earth
neutral
phases
The following pages show the electrical diagrams: please refer
to the one of the specific model to connect.
The diagrams on the right are supplied in case of replacement of
the connection cable with a new one, as the machines have the
connection cable already fitted.

12
20K
Fig. 9
Fig. 10
Installation
Electrical data
Model
SILEA
Supply
VkW Average
consumption
kW/h
Absorbed
current
A
Cable type*
n x mm2
Cust. panel
prot.
nxA
20
single-phase 230V 50/60Hz 0.75 0.45 3.3 3x1,5 2x16
three-phase 3x230V50/60Hz 0.75 0.45 1.9 4x1,5 3x16
three-phase 3x400V+N 50/60Hz 0.75 0.45 1.1 5x1,5 4x16
30
single-phase 230V 50/60Hz 1.1 0.66 4.8 3x1,5 2x16
three-phase 3x230V50/60Hz 1.1 0.66 1.8 4x1,5 3x16
three-phase 3x400V+N 50/60Hz 1.1 0.66 2.6 5x1,5 4x16
single-phase 208v 50-60Hz 1.1 0.66 5.3 3xAWG16 3x16
three-phase 3x208V50/60Hz 1.9 1.14 5.3 4xAWG16 4x16

13
Ed. 0121 - 70702580 REV01 Silea - Pre-installation
3 230-V 3 N 400-V
RSTRS TN
Wiring diagrams
Abbreviation Description
SB1 Stop button
SB2 ON button
KM1 Contactor
FR1 Internal thermal protection
SQU1
Safety microcontact
Abbreviation Description
SB1 Stop button
SB2 ON button
KM1 Contactor
FR1 Internal thermal protection
SQU1
Safety microcontact

14
230-V 208-V
FN L1 L2
Wiring diagrams
Abbreviation Description
SB1 Stop button
SB2 ON button
KM1 Contactor
FR1 Internal thermal protection
SQU1
Safety microcontact
Abbreviation Description
SB1 Stop button
SB2 ON button
KM1 Contactor
FR1 Internal thermal protection
SQU1
Safety microcontact

15
Ed. 0121 - 70702580 REV01 Silea - Pre-installation
3 208V
L1 L2 L3
Wiring diagrams
Abbreviation Description
SB1 Stop button
SB2 ON button
KM1 Contactor
FR1 Internal thermal protection
SQU1
Safety microcontact

16
Pre-testing and nal inspection
The product is checked and tested in the Manufacturer’s plant before being delivered to the customer.
The“production process check sheet”enclosed with it guarantees that each step in the production process, from assembly to packaging, was carefully checked from both the operating and safety
standpoints.
After installing the appliance, to complete the installation, carry out A, B, Cand D.
AChecking the installation is correct
Mark with a “√“ all the boxes of the table below: this will confirm the installation is complete and correct.
√ Positioning checks
Is the installation room adequate and compliant with regulations? (minimum, maximum temperature, etc.)
Is the appliance resting on a perfectly level floor?
Have the minimum distances stated been complied with?
Has the protective film been removed from the surfaces?
√ Electrical checks
Does the mains voltage match the data on the rating plate?
Do electric connections meet current regulations in the country
of installation and follow the diagrams supplied?
√ Miscellaneous
Does the user have all the documentation relative to the product?
4FINAL OPERATIONS

17
Ed. 0121 - 70702580 REV01 Silea - Pre-installation
20K
Final operations
•in three-phase machines swap one of the phases over;
•in single-phase machines check the bridges on the motor
W
2
U
1
V
1
W
1
U
2
V
2
W
2
U
1
V
1
W
1
U
2
V
2
BRIDGES POSITIONED CORRECTLY the bowl will rotate in the direction of the arrow
If, after connecting the wires to the plug, the bowl rotates in the wrong
direction swap two phases over (e.g. black wire with brown wire)
BRIDGES POSITIONED INCORRECTLY the bowl will rotate in the opposite direction
BChecking the correct direction of rotation of the bowl
Make sure that the bowl rotates in the direction of the arrow.
If this is not the case:

Final operations
DWarranty activation
At the end of the test, the warranty MUST be activated.
IF NOT REGULARLY ACTIVATED, THE VALIDITY OF THE SAME STARTS FROM THE INVOICE DATE AND NOT FROM THE ACTUAL INSTALLATION
DATE.
CChecking the operation and rst start-up
Start the appliance following the instructions in the “Use and Maintenance”manual annexed: monitor it during the whole test and check that all the electrical components work properly.

19
Ed. 0121 - 70702580 REV01 Silea - Pre-installation

CUPPONE 1963
Cuppone F.lli S.r.l.
Via Sile, 36
31057 Silea (TV) - ITALY
T +39 0422 361143
F +39 0422 360993
Other manuals for SILEA 20
1
This manual suits for next models
1
Table of contents
Other Cuppone Mixer manuals