manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Curbell
  6. •
  7. Measuring Instrument
  8. •
  9. Curbell CareSense CSM-PM100 User manual

Curbell CareSense CSM-PM100 User manual

Remove the plastic film from face of the
monitor, and install batteries.
Confirm that the green “IN USE” light is flashing.
Attach the linen clip to the patient’s clothing
(out of the patient’s reach)
Adjust the volume control in the battery
compartment, close the cover, and
tighten the screw
TEST THE ALARM: Remove the magnetic
dome from the socket. The alarm will sound,
and the red “ALARM” light will flash.
Adjust the string to a length that will pull out
the magnetic dome to activate the alarm if the
patient attempts an exit.
CONNECTING TO NURSE CALL: Plug a Nurse
Call Connection Cable into the ”NURSE CALL”
socket on the monitor, connect the opposite
end of cable into Nurse Call Station (an adaptor
may be required) and test.
Attach the Velcro strap.
Secure the monitor to back of the patient’s
chair or bed.
1
1
4
2
2
5 6
3
3
Setup
©2015 Curbell Medical Products, Inc. MAP1212B
www.curbellmedical.com • 1-888-222-2188
CSM-PM100 QUICK SETUP GUIDE NOTE: Consult the “Directions For Use” included with monitor for
complete instructions, troubleshooting, and safety information
Use
This checklist has been developed to help identify common issues that can be quickly
addressed to prevent unnecessary product returns. Please also refer to the product’s
Directions for Use and instructional video on Curbell’s website (www.curbellmedical.com).
If, after completing the checklist, the product continues to malfunction, please call your
Curbell Representative at 888-222-2188.
No power/green “IN USE” light does not blink
o Batteries are installed according to the diagram in the battery compartment.
o Batteries are fresh and/or known to be good.
No alert is given to the facility’s nurse call system
o The connection between the monitor and the nurse call patient station is securely connected and not
damaged (a 1/4” mono nurse call jack and/or an adaptor for compatibility is required).
False alarm occurs
o Check that the magnetic dome is secured in the monitor socket.
o Check that the string length is not too short.
A chirping sound occurs
o Check for a Low battery LED indicator and replace the batteries if necessary.
No alarm sound occurs
o The volume level has been turned up.
3
3
3
3
3
3
3
CSM-PM100 TROUBLESHOOTING CHECKLIST

Popular Measuring Instrument manuals by other brands

CDI Meters CDI 25 Installation and operating instructions

CDI Meters

CDI Meters CDI 25 Installation and operating instructions

AG ZR-HM3-50-RC Installation and instruction manual

AG

AG ZR-HM3-50-RC Installation and instruction manual

KROHNE OPTISWIRL 4200 quick start

KROHNE

KROHNE OPTISWIRL 4200 quick start

Metrohm NIRS DS2500 manual

Metrohm

Metrohm NIRS DS2500 manual

Hawk OptioLaser L200 manual

Hawk

Hawk OptioLaser L200 manual

AGFA DX-G user manual

AGFA

AGFA DX-G user manual

Agilent Technologies 8702D installation guide

Agilent Technologies

Agilent Technologies 8702D installation guide

PASCO SF-9568A instruction sheet

PASCO

PASCO SF-9568A instruction sheet

Memsense Nano IMU Product Specification & User Guide

Memsense

Memsense Nano IMU Product Specification & User Guide

PeakTech 1650 Operation manual

PeakTech

PeakTech 1650 Operation manual

H. HERMANN EHLERS CONTOIL VZO Series Mounting and operating instructions

H. HERMANN EHLERS

H. HERMANN EHLERS CONTOIL VZO Series Mounting and operating instructions

Unipulse F320 Operation manual

Unipulse

Unipulse F320 Operation manual

Radiodetection PCMx Operation manual

Radiodetection

Radiodetection PCMx Operation manual

Audison APM owner's manual

Audison

Audison APM owner's manual

Elamed EASYTON manual

Elamed

Elamed EASYTON manual

Industrial Scientific Ventis MX4 Operation manual

Industrial Scientific

Industrial Scientific Ventis MX4 Operation manual

Xylem Sensus PolluTherm F Installation and operating instructions

Xylem

Xylem Sensus PolluTherm F Installation and operating instructions

AMALGAMATED INSTRUMENT HH4-PH Operation and instruction manual

AMALGAMATED INSTRUMENT

AMALGAMATED INSTRUMENT HH4-PH Operation and instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.