DISCLAIMERS
The information in this manual has been carefully checked and
is believed to be accurate. Cypress Technology assumes no
responsibility for any infringements of patents or other rights of third
parties which may result from its use.
Cypress Technology assumes no responsibility for any inaccuracies
that may be contained in this document. Cypress also makes no
commitment to update or to keep current the information contained
in this document.
Cypress Technology reserves the right to make improvements to this
document and/or product at any time and without notice.
COPYRIGHT NOTICE
No part of this document may be reproduced, transmitted,
transcribed, stored in a retrieval system, or any of its part translated
into any language or computer le, in any form or by any means—
electronic, mechanical, magnetic, optical, chemical, manual, or
otherwise—without express written permission and consent from
Cypress Technology.
© Copyright 2015 by Cypress Technology.
All Rights Reserved.
TRADEMARK ACKNOWLEDGMENTS
All products or service names mentioned in this document may be
trademarks of the companies with which they are associated.

SAFETY PRECAUTIONS
Please read all instructions before attempting to unpack, install or
operate this equipment and before connecting the power supply.
Please keep the following in mind as you unpack and install this
equipment:
• Always follow basic safety precautions to reduce the risk of re,
electrical shock and injury to persons.
• To prevent re or shock hazard, do not expose the unit to rain,
moisture or install this product near water.
• Never spill liquid of any kind on or into this product.
• Never push an object of any kind into this product through any
openings or empty slots in the unit, as you may damage parts
inside the unit.
• Do not attach the power supply cabling to building surfaces.
• Use only the supplied power supply unit (PSU). Do not use the PSU
if it is damaged.
• Do not allow anything to rest on the power cabling or allow any
weight to be placed upon it or any person walk on it.
• To protect the unit from overheating, do not block any vents or
openings in the unit housing that provide ventilation and allow for
sufcient space for air to circulate around the unit.
REVISION HISTORY
VERSION NO. DATE (DD/MM/YY) SUMMARY OF CHANGE
RDV1 30/07/15 Preliminary release
RDV2 03/08/16 Draft manual

CONTENTS
1. Introduction............................................ 1
2. Applications........................................... 1
3. Package Contents ................................ 1
4. System Requirements............................ 2
5. Features.................................................. 2
6. Operation Controls and Functions....... 3
6.1 Front Panel ........................................3
6.2 Top Panel ..........................................7
6.3 Bottom Panel ....................................7
6.4 Left Panel ..........................................8
6.5 Right Panel........................................8
6.6 Remote Control................................9
6.7 RS-232 Protocol...............................10
6.8 RS-232 and Telnet Commands .....11
6.9 Telnet Control .................................15
6.10 OSD Menu.....................................17
6.10 .1 Analyzer Mode...................17
6.10. 2 Pattern Mode .....................22
6.11 Test Timings....................................26
6.11.1 Input Timings ........................26
6.11.2 Output Timings ....................27
6.12 Test Patterns..................................29
7. Connection Diagram .......................... 42
8. Specications ...................................... 43
8.1 Technical Specications ...............43
8.2 Supported Color Formats..............44
8.3 Supported Audio Formats .............44
9. Acronyms ............................................. 45

1
1. INTRODUCTION
The HDMI 6G Signal Generator & Analyzer is an advanced and handy
tool for generating, testing and verifying the signal path within your 6G
HDMI ecosystem. With 88 built-in resolutions, 55 test patterns and over
a dozen types of A/V analysis functions, this unit provides an enormous
range of testing options. HDMI data packet, EDID and HDCP analysis
is supported along with EDID upload and emulation. Additionally the
Status and Control Data Channel (SCDC) can be monitored, allowing
HDMI 6G signal detection and analysis. Up to 8 channels of LPCM
audio test tones can be generated with a wide range of frequencies.
The unit also supports the ability to upload up to 2 user-generated
graphic les which can be used as additional test patterns. The use of
multi-function and multi-color backlit buttons allows for easy operation
of the unit’s wide variety of functions and a clear OLED display
provides a way to quickly view the current signal status information. In
addition to the front panel buttons, the unit can also be controlled via
RS-232, Telnet and IR providing a complete range of control options.
2. APPLICATIONS
• Installer/Integrator multi-function test tool
• HDMI source and sink testing
• UHD system/SCDC error identication
• Third-party equipment setup
• Source and sink EDID reading, writing and saving
• HDCP compliance verication
• Production testing
• R&D design and testing
3. PACKAGE CONTENTS
• 1×HDMI 6G Signal Generator & Analyzer
• 1×Remote Control (CR-174)
• 1×DC to USB Power Cable
• 1×5V/2.6A Power Adaptor
• 1×Operation Manual

2
4. SYSTEM REQUIREMENTS
• HDMI/VGA receiving equipment such as an HDTV, monitor or audio
amplier and/or HDMI source equipment such as a media player,
video game console or set-top box.
• Analog audio source equipment such as a PC or media player
and/or analog audio receiving equipment such as headphones, an
audio amplier or powered speakers.
• RS-232 or Ethernet control device such as PC/Laptop (Optional)
• USB enabled device for uploading user test patterns
5. FEATURES
• HDMI 2.0 (up to 4K@60Hz 4:4:4) and DVI 1.0 compliant
• HDCP 1.4 and 2.2 compliant
• Analysis of source and sink data paths up to 6G HDMI signals
• Analysis of HDMI data packets
• Analysis and control of HDCP v1.4 and v2.2
• Analysis and emulation of EDID data, including SCDC
• Analysis of input audio signals
• HDR bypass and analysis support
• Generate HDMI timings up to 6Gbps (4096×2160@60Hz 4:4:4, 8-bit)
• Generate HDMI and VGA signal outputs
- VGA output resolutions: 350p, 480p, 576p, 720p, 1080i, 1080p,
640×480, 800×600, 1024×768, 1280×1024, 1366×768, 1400×1050,
1440×900, 1600×900RB, 1600×1200, 1680×1050, 1920×1200RB,
2048×1080p
- HDMI output resolutions: 350p, 480p, 576p, 720p, 1080i, 1080p,
640×480, 800×600, 1024×768, 1280×1024, 1366×768, 1400×1050,
1440×900, 1600×900RB, 1600×1200, 1680×1050, 1920×1200RB, 3G4K,
6G4K
• 2 custom user test pattern resolutions - 640×480 & 1920×1080
• External stereo audio input and output
• Generation of LPCM sinewave audio on up to 8 channels
• Front-panel, RS-232, Telnet, and IR Remote controls

3
• OLED display with rapid updates of current status information
• Detailed OSD for settings and informational displays
• Supports USB rmware and pattern update
• Small, portable, unit with DC and USB power support
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
FACTORY
RESET
MENU ENTER
OPTION
COLOR
SPACE TIMING PATTERN
HDCP
PATTERN
EDID
PATTERN
DEEP
COLOR
OUTPUT
FORMAT
ANALYSER
/ PATTERN
HDCP
ON/OFF
AUDIO
LPCM
-
+
HDCP2.2
No Signal
5V=0 CKDT=0 SCDT=0
1
8
5
6
7
4
2
1512
10 1413119
3
1OLED Screen: Displays the current signal analysis information
or test pattern mode selection details including input and/or
output resolution timing. The screen layout changes completely
depending on the unit’s mode.

4
Analyzer Mode (Analyzer/Pattern button is RED): In Analyzer mode,
if there is no live video source detected on the input port, the
OLED will display any voltage, TMDS or sync that might be present.
Once a live video signal is detected, the unit will display that
signal’s current timing, format, HDCP version, AV Mute status, color
space, color depth and audio format.
No Signal
5V=0 SKDT=0 SCDT=0
TMDS clock
detection
+5V pin
detection
Sync signal
detection
1920x2080p24 3D HDMI
HDCP1 M Y444 12B LPCM
Resolution
HDCP
1.4/2.2
Color
depth
Color
space
General control
package
Audio
HDMI/DVI3D
Pattern Mode (Analyzer/Pattern button is BLUE): In Pattern mode,
when the output isn’t connected to a sink, the unit will display the
current output timing, Rx Sense, and Hot-plug detection status.
Once an active sink has been connected, the lower portion of the
display will change to indicate the current test pattern number
and name.
T62 1080p59
Sink RSEN=0 HPD=0
Hot plug
detection
RX sense
detection
Sink/
Source
T62 1080p59
P06 Colorbar S.
Test pattern
Test timing
2IR Window: Accepts IR signals from the included IR remote for
control of this unit only.
3MENU: Press to enter the OSD menu, or to back out from menu
items.
4ENTER/OPTION: Press to conrm a selection or to go deeper into a
menu item. When the selected function has optional selections,

5
the associated button’s LED will illuminate along with the ▼/▲ (-/+)
buttons.
5 +/- & ▲/▼: Press to move up and down or adjust selections within
menus. These buttons will illuminate when the selected function
has values that can be adjusted up or down.
6PATTERN: Within Pattern mode, press to enable selection of the
test pattern used. The ▼/▲ buttons will illuminate and are used
to select the new pattern. The new test pattern will automatically
become active after selecting it and pausing for 2 seconds. Within
Analyzer mode, press to turn on/off a “title-safe/action-safe”
overlay.
7TIMING: Press to enable selection of the output timing and
resolution used. The ▼/▲ buttons will illuminate and are used to
select the new timing. The currently selected timing will be shown
on the OLED display. The new timing will automatically become
active after selecting it and pausing for 2 seconds.
Note: In Analyzer mode, please select the “Bypass” timing if you
do not wish for your source’s output signal to be scaled by the unit
before being sent to the display. The LED will blink Red when the
timing is set to Bypass.
8ANALSER/PATTERN: Press to switch the unit between Analyzer Mode
(LED=Red) and Pattern Mode (LED=Red). When in Analyzer Mode,
press and hold the button for 2 seconds to force an Rx hot-plug.
When in Pattern Mode, press and hold the button for 2 seconds
to turn on/off the AVMute bit within the output’s GCP (General
Control Packet).
FACTORY RESET: Press and hold this button while powering the unit
on to perform a factory reset of the unit.
9EDID PATTERN: Press to enable selection of the EDID to use on the
HDMI input port. The ▼/▲ buttons will illuminate and are used to
select the new EDID. The currently selected EDID will be shown on
the OLED display. The new EDID will automatically become active
after selecting it and pausing for 5 seconds.
10 AUDIO LPCM: Within Analyzer mode, press to select which digital
audio source pair (0-3) is routed to the primary stereo channel
(LPCM 2.0 and headphone output) for monitoring. The LED color
indicates the selection (Off=SD0, Red=SD1, Blue=SD2, Purple=SD3).
Within Pattern mode, press to switch between LPCM 2.0

6
(LED=Red), 5.1 (LED=Blue) and 7.1 (LED=Purple) channel test tone
output formats. Press and hold this button for 2 seconds to allow
adjustment of the output volume.
11 HDCP PATTERN: Press to enable/disable the OSD display of the
detected HDCP version support and handshaking information
between the sink and source. In Analyzer mode the unit is the
Rx, in Pattern mode the unit is the Tx. In Pattern mode, if HDCP
handshaking fails, an error message “HDCP OUT FAIL” will be
displayed on the OSD.
12 HDCP ON/OFF: Press to switch between supported HDCP versions
or to disable HDCP. Within Analyzer mode, OFF (LED=Off), HDCP 1.4
(LED=Red), and HDCP 1.4+2.2 (LED=Blue) modes are available for
the input port. Within Pattern mode, OFF, HDCP 1.4, and HDCP 2.2
modes are available for the output port.
13 COLOR SPACE: Press repeatedly to switch between the available
color space formats. The button’s LED is colored to indicate the
current color space: Red=RGB, Blue=YCbCr 4:4:4, Purple=YCbCr
4:2:0, Off=YCbCr 4:2:2.
14 DEEP COLOR: Press repeatedly to switch between the available
output color bit depth options. The button’s LED is colored to
indicate the current bit depth: Off=8-bit, Red=10-bit, Blue=12-bit.
15 OUTPUT FORMAT: Press to switch between DVI (LED=Blue) and HDMI
(LED=Red) output formats. Press and hold the button for 2 seconds
to disable/enable video output completely. The button’s LED will
turn off when output is disabled.

7
6.2 Top Panel
VGA OUT
HDMI OUT
AUDIO OUT
321
1AUDIO OUT: Connect to powered speakers or an amplier for
stereo analog audio output with a 3.5mm phone jack cable.
2VGA OUT: Connect to a VGA (RGB) monitor or display for analog
video output.
3HDMI OUT: Connect to HDMI TVs, monitors or ampliers for digital
video and audio output.
6.3 Bottom Panel
HDMI IN
AUDIO IN
1 2
1HDMI IN: Connect to HDMI source equipment such as a media
player, game console or set-top box.
2AUDIO IN: Connect to the stereo analog output of a device such
as a CD player or PC.

8
6.4 Left Panel
POWER
1
1POWER: Flip this switch to turn the unit ON or OFF after connecting
an appropriate power source.
6.5 Right Panel
CONTROLRS232 SERVICE DC 5V
1 2 3 4
1CONTROL: Connect directly, or through a network switch, to your
PC/laptop to control the unit via Telnet.
1RS-232: Connect directly to your PC/laptop to send RS-232
commands to control the unit.
1SERVICE: This slot is used for rmware updates and uploading
customer designed test pattern les.
Note: The patterns are restricted to 640×480 and 1920×1080. Both
must be 24-bit RGB bitmap les
1DC 5V: Plug the 5V DC power supply into the unit and connect it
to an AC wall outlet for power or use the DC to USB adapter cable
to connect to a portable USB power bank for power.

9
6.6 Remote Control
1Analyzer/Pattern: Press to switch
between Analyzer Mode and Pattern
Mode.
2EDID: Press repeatedly to switch
between the available EDIDs for the
HDMI input.
3Color Space: Press repeatedly to
switch between the available color
space formats (RGB, YCbCr 4:4:4,
YCbCr 4:2:2 and YCbCr 4:2:0).
4HDCP SW.: Press to switch between
supported HDCP versions or to
disable HDCP.
5Format: Press to switch between DVI
and HDMI output formats.
6VGA~4K6G: Press to directly select
the output resolution.
7Output On: Press to enable video output.
8Output Off: Press to disable video output.
9T-/T+/P+/P-/OK: Press to move up and down or adjust selections
within menus. Press OK to conrm the selection.
10 Menu: Press to enter the OSD menu.
11 Exit: Press to exit the OSD or cancel the selection.
12 Source*: Press to display source signal information on the OSD.
Video T*.: Press to display video analysis details on the OSD.
Audio T*.: Press to display audio analysis details on the OSD.
Packet*: Press to display the HDMI input’s packet analysis info.
Hotplug*: Press to force an Rx hot-plug event on the input port.
Note: * for use in Analyzer Mode only.
Sink**: Press to display HDMI output detection/information on the
OSD.
AV Mute1**: Press to turn on the AVMute bit within the output’s
GCP.
CR-174
OK
Output On
Pattern
Analyser/
HDCP SW.
Output Off
Color Space FormatEDID
T+
Menu
P+
Exit
P
-
T
-
Audio CH HotplugPacket
Sink AVMute1 AVMute0
Source Audio T.Video T.
VGAWXGA WUXGA
480p 720p 1080p
1080i4K3G 4K6G
Vol+Vol-Mute
1
2
7
6
9
10
12
13
4
5
3
8
11
14

10
AV Mute0**: Press to turn off the AVMute bit within the output’s
GCP.
Note: ** for use in Pattern Mode only.
13 Audio CH: Within Analyzer mode, press to select which digital
audio source pair (0-3) is routed to the primary stereo channel for
monitoring. Within Pattern mode, press to switch between LPCM 2.0,
5.1 and 7.1 channel test tone output formats.
14 Mute/Vol-/Vol+: Press the Mute button to mute both digital and
analog audio outputs. Press the Vol-/Vol+ buttons to increase/
decrease the volume.
6.7 RS-232 Protocol
SIGNAL GENERATOR
►
◄
REMOTE CONTROLLER
Pin Assignment Pin Assignment
1 NC 1 NC
2TxD 2RxD
3RxD 3TxD
4 NC 4 NC
5 GND 5 GND
6 NC 6 NC
7 NC 7 NC
8 NC 8 NC
9 NC 9 NC
Baud Rate: 115200bps
Data bit: 8 bits
Parity: None
Flow Control: None
Stop Bit: 1

11
6.8 RS-232 and Telnet Commands
COMMAND RESPONSE DESCRIPTION
>boot [go] >boot ready Re-start system. During
booting, system
doesn't respond to any
command.
>boot? >boot? ready Get boot status
>edid_copy_sink [c1/
c2~c10]
>edid_copy_sink c1/
c2~c10/err
Copy HDMI sink EDID
to one of Copy1~10. If
copy fail, respond "err".
>edid_read [d1/
d2~d10/c1/c2~c10/
sink],[block0/1]
>edid_read d1/d2~d10/
c1/c2~c10/
sink,block0/block1
<CR><LF>128byte data
Console reads one of
EDID - Default1~10,
Copy1~10 or HDMI sink.
The data stream is
continuous 128 bytes
after - end characters -
CR+LF are sent. (Telnet
NOT support)
>edid_rx [d1/d2~d10/
c1/c2~c10/sink]
>edid_rx d1/d2~d10/c1/
c2~c10/sink
Select Rx EDID from
Default1~10, Copy1~10
or HDMI sink.
>edid_rx? >edid_rx? d1/d2~d10/
c1/c2~c10/sink
Get Rx EDID selection
>edid_write [c1/
c2~c10],[block0/
block1]<CR><LF>
[128byte data]
>edid_write c1/
c2~c10,block0/block1
>edid_write err_
checksum/err_syntax
Console writes an EDID
le to one of Copy1~10.
The data stream is
continuous 128 bytes
after - end characters
- CR+LF are received.
(Telnet NOT support)
>err System responds to
invalid command
>factory >boot ready Do factory reset & re-
start system
>fwver? >fwver? vx.xx Get rmware main-
version for customer
>hdcp_in_sw [off/on] >hdcp_in_sw off/on Set HDCP input port
switch on/off in Analyzer
mode

12
COMMAND RESPONSE DESCRIPTION
>hdcp_in_sw? >hdcp_in_sw? off/on Get HDCP input port
switch on/off setting
>hdcp_in_detect? >hdcp_in_detect? off/
v1.4/v2.2
Detect HDCP status of
source
>hdcp_in_ver [v1.4/
v1.4+v2.2]
>hdcp_in_ver v1.4/
v1.4+v2.2
Set HDCP input port
version in Analyzer
mode
>hdcp_in_ver? >hdcp_in_ver? v1.4/
v1.4+v2.2
Get HDCP input port
version setting
>hdcp_out_sw [off/on] >hdcp_out_sw off/on Set HDCP output switch
on/off in pattern mode
>hdcp_out_sw? >hdcp_out_sw? off/
v1.4_on/v1.4_talk/v2.2_
on/v2.2_talk
Get HDCP output
switch status in Analyzer
or pattern mode
"talk" means it's going
handshaking.
>hdcp_out_ver [v1.4/
v2.2]
>hdcp_out_ver v1.4/
v2.2
Set HDCP output version
in pattern mode
>hdcp_out_ver? >hdcp_out_ver? v1.4/
v2.2
Get HDCP output
version setting in pattern
mode
>help Show command list
>? Show command list
>model? >model? CPHD-V4 Get model number
>motion_text [text] Max.
20 Char
>motion_text text Set text for pattern
Motion-H and Motion-V.
Maximum length of text
is 20 characters.
>motion_text? >motion_text? text Get text for pattern
Motion-H and Motion-V.
>net_gate? >net_gate? xxx.xxx.xxx.
xxx
Get gateway address
status
>net_ip? >net_ip? xxx.xxx.xxx.xxx Get IP address status
>net_ip_mode [dhcp/
static]
>net_ip_mode dhcp/
static
Set IP mode
>net_ip_mode? >net_ip_mode? dhcp/
static
Get IP mode status
>net_link? >net_link? link/not_link Get Ethernet link status

13
COMMAND RESPONSE DESCRIPTION
>net_mac? >net_mac? xx-xx-xx-xx-
xx-xx
Get Ethernet MAC
address
>net_mask? >net_mask? xxx.xxx.xxx.
xxx
Get subnet mask
address status
>net_static_gate [xxx.
xxx.xxx.xxx]
>net_static_gate xxx.
xxx.xxx.xxx
Set static gateway
address
>net_static_gate? >net_static_gate? xxx.
xxx.xxx.xxx
Get static gateway
address
>net_static_ip [xxx.xxx.
xxx.xxx]
>net_static_ip xxx.xxx.
xxx.xxx
Set static IP address
>net_static_ip? >net_static_ip? xxx.xxx.
xxx.xxx
Get static IP address
>net_static_mask [xxx.
xxx.xxx.xxx]
>net_static_mask xxx.
xxx.xxx.xxx
Set static subnet mask
address
>net_static_mask? >net_static_mask? xxx.
xxx.xxx.xxx
Get static subnet mask
address
>pattern [1/2/3/~] >pattern 1/2/3/~ Select pattern P01/P02/
P03~
>pattern? >pattern? 1/2/3/~ Get pattern selection
>task_mode [analyser/
pattern]
>task_mode analyser/
pattern
Set task mode
>task_mode? >task_mode? analyser/
pattern
Get task mode
>timing [1/2/3/~] >timing 1/2/3/~ Select video timing T01/
T02/T03~
>timing? >timing? 1/2/3/~ Get video timing
selection
>update_fw >boot ready Update rmware from
USB & re-start system
>update_img480 >boot ready Update image 640x480
from USB & re-start
system
>update_img1080 >boot ready Update image
1920x1080 from USB &
re-start system
Note:
• Start Character is > , Stop Character is Carriage Return ASC(0x0D)

14
• Commands are case-insensitive
• Symbol '[' , ']' mean inner is parameter. No need to input char '[' , ']'
• Response for a command repeats the original command except
>err, >help
• Response command with end characters - Carriage Return(0x0D) +
Line Feed(0x0A)
• Console should wait for response before next command execution.
• Command with end character ? means inquire status.
• System responds >err to invalid command
• Remark H means it's a hidden & protected command.
• Some commands are not supported for Telnet.

15
6.9 Telnet Control
Before attempting to use Telnet control, please ensure that both
the matrix and the PC/Laptop are connected to the same active
networks. To access Telnet in Windows 7, click on the “Start” menu
and type “cmd” in the search eld, then press “Enter”. Under Windows
XP go to the “Start” menu, click on "Run", type "cmd" then press “Enter”.
Under Mac OS X, go to Go→Applications→Utilities→Terminal. See
below for reference.
Once in the CLI (Command Line Interface) type "telnet" followed by
the IP address of the unit and "23", then hit “Enter”. The IP address is
available on LCM display.
Other manuals for CPHD-V4
2
Table of contents
Other CYP Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

TSI Incorporated
TSI Incorporated VELOCICALC 5725 Operation and service manual

wtw
wtw Cond 1970i operating manual

Servomex
Servomex 2500 Series installation manual

Compressed Air Alliance
Compressed Air Alliance POM400 user manual

Sonic Meter
Sonic Meter Soni operating manual

Hilti
Hilti PD 42 operating instructions