1
Corporate Headquarters, Sales & Manufacturing:
Dabir Surfaces, Inc., 7447 West Wilson Ave., Harwood Heights, IL 60706, USA, www.dabir-surfaces.com
Sales Inquiries: sales@dabir-surfaces.com, Tel: +1(888)559-3641
Technical Support: support@dabir-surfaces.com, Tel: +1(888)559-3642
PATENT: www.dabir-surfaces.com/patents
Distributor (North America): STERIS Corporaon, Customer Service, Tel: +1(800)548-4873, Fax: +1(440)639-4450; Service Support, Tel: +1(800)333-8828
Authorized European Rep: Emergo Europe, Prinsessegracht 20, 2514 AP The Hague, The Netherlands
DOC# R02-0006-00014-IA 1
MD
®
Quick Set-Up Guide (C2-10XX Models ONLY)
Important Before You Start: THIS IS A “QUICK SET-UP” GUIDE ONLY
Please refer to the Dabir Operaon / Service Technical Manual for full set-up and usage instrucons. Failure to carefully read and
follow all instrucons and safety informaon may result in decreased product performance or injury.
Controller Pre-Assembly
1. Remove components from their individual packaging containers.
2. Place controller on a at, stable surface, away from any edges to
prevent fall damage.
3. Insert latching power cord as shown.
4. Conrm proper inseron with a slight pull.
5. If applicable, assemble controller mounng accessories per the
separately supplied user instrucons. (RECOMMENDED)
STEP 3: Insert power cord
System Installaon - Controller
6. Place controller in a safe, stable locaon near a wall power outlet
and at an appropriate distance from the paent care area.
7. Route the power cord such that it does NOT present a trip hazard.
8. Plug the power cord into the AC wall receptacle or other power
source with appropriate currents and protecve earth ground.
STEP 8: Plug-in power cord
System Installaon - Surfaces
9. Place surface onto at maress with “THIS SIDE UP” facing up (gray
side down) and secure oponal corner straps when applicable.
(Surface should lay at when properly installed.) Hose exit orientaon
is oponal depending on the desired set-up.
10. Place facility supplied linen and inconnence pad(s) over the top of
the surface and tuck edges underneath the maress. Avoid wrinkles
whenever possible to opmize Dabir performance and paent
comfort.
STEP 9: Place surface onto at Maress
WARNINGS / CAUTIONS:
• Surfaces are intended to be used ABOVE an underlying bed
maress with good pressure redistribuon properes over the full
paent contact area.
• Always place the surface ABOVE the maress and cover it with a
bed linen. (Surfaces are NOT intended to be used in direct contact
with the paent’s skin.)
• It is the responsibility of the user to secure and protect against
paent movement and/or falls.
• It is the responsibility of the user to properly clean and disinfect the
system prior to paent use. (Visit www.dabir-surfaces.com/cleaners
for a list of Dabir approved & unapproved cleaners.)
NOTE: Controller User Interface may vary from instrucons.