Dakota Computer Solutions Scout KVM Switch User manual

Scout kvm switch™
Keyboard, Monitor & M ouse Switch
Installation and Operation Manual
ENGLISH/DEUTSCH

LIMITED WARRANTY
Dakota Computer Solutions warrants the Scout KVM Switch™ to be in good working order for one year from
the date of purchase from Dakota Computer Solutions or an authorised dealer. Should this product fail to be in
good working order at any time during this one year warranty period, Dakota Computer Solutions will, at its
option, repair or replace the Unit as set forth below. Repair parts and replacement units will be either
reconditioned or new. All replaced parts become the property of Dakota Computer Solutions. This limited
warranty does not include service to repair damage to the Unit resulting from accident, disaster, abuse, or
unauthorised modification of the Unit, including static discharge and power surges.
Limited Warranty service may be obtained by delivering this unit during the one year warranty period to Dakota
Computer Solutions or an authorised repair centre providing a proof of purchase date. If this Unit is delivered by
mail, you agree to insure the Unit or assume the risk of loss or damage in transit, to prepay shipping charges to
the warranty service location, and to use the original shipping container or its equivalent. You must call for a
return authorisation number first. Under no circumstances will a unit be accepted without a return authorisation
number. Contact an authorised repair centre or Dakota Computer Solutions for further information
ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT INCLUDING THE WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN
DURATION TO A PERIOD OF ONE YEAR FROM THE DATE OF PURCHASE, AND NO WARRANTIES,
WHETHER EXPRESS OR IMPLIED, WILL APPLY AFTER THIS PERIOD. SOME COUNTRIES DO NOT
ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE
LIMITATION MAY NOT APPLY TO YOU.
IF THIS PRODUCT IS NOT IN GOOD WORKING ORDER AS WARRANTED ABOVE, YOUR SOLE
REMEDY SHALL BE REPLACEMENT OR REPAIR AS PROVIDED ABOVE. IN NO EVENT WILL
DAKOTA COMPUTER SOLUTIONS BE LIABLE TO YOU FOR ANY DAMAGES INCLUDING ANY
LOST PROFITS, LOST SAVINGS OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES
ARISING OUT OF THE USE OF OR THE INABILITY TO USE SUCH PRODUCT, EVEN IF DAKOTA
COMPUTER SOLUTIONS OR AN AUTHORISED DEALER HAS BEEN ADVISED OF THE POSSIBILITY
OF SUCH DAMAGES, OR FOR ANY CLAIM BY ANY OTHER PARTY.
C€
NOTE: This equipment complies with the requirements for the following Agency Approvals:
UL1950, CSA C22.2 No. 950, EN60950, FCC parti 5B, EN55022 and EN50082
This equipment has been found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
© Copyright 2000. All rights reserved.
No part of this manual may be reproduced, stored in a retrieval system, or transcribed in any form or any means,
electronic or mechanical, including photocopying and recording, without the prior written permission o f Dakota
Computer Solutions.
IBM ® AT, and PS/2 are trademarks of International Business Machines Corp.
Microsoft ® and Microsoft Windows ™ are registered trademarks of Microsoft Corp.
Multisync is a trademark of NEC Technologies, Inc.

INSTALLATIO N
Locating the Scout unit
The Scout unit is best located as close to the CPUs as possible. This will reduce the length of
the CPU cables and provide a more cost-effective and neater installation. While usage of the
Scout is trouble-free and transparent and need not be in an accessible location, you may wish
to access the front panel to verify the currently selected port or to switch to the next port.
Connecting the Unit
1. Connecting the keyboard, monitor and mouse. The monitor, keyboard and mouse connect
directly to the unit.
2. Connecting the CPUs. CPU Cable sets connect your computers to the Scout. Each
computer requires its own CPU cable kit, with appropriate connectors for your particular
CPU. CPU cable kits are available where you purchased your Scout.
3. Plug the keyboard monitor and mouse connectors of the CPU set cable into one of the
numbered CPU ports on the Scout’s rear panel.
4. Plug the CPU cable kits cable’s keyboard, monitor and mouse connectors into the CPU’s
corresponding ports.
5. Powering up the system. Boot up each of the connected CPUs.
Your Scout is now ready for operation using its default settings. This information is
summarised in the Keyboard command summary.
■

Basic Operations
PCs may be powered-up one-at-a-time or all at once. The green LEDs over each channel will
light, indicating that the attached computer is powered on. After power-up, a lit amber LED
indicates the selected computer. Other PCs may now be selected for operation.
Selecting a PC
___________________________________________________
There are two ways to select a PC. One way is via the Select button. This selects the next
computer in sequence. Another way is by entering a short sequence of keystrokes on the
keyboard. This is called keyboard, or hot-key, switching.
Press the Control key twice within one second to place your Scout in Command Mode. Your
keyboard LEDs will flash to verify that you are operating in Command Mode. Now, what ever
you type will be interpreted as Scout system commands until Enter is pressed to accept the
command or Escape is pressed to cancel.
In Command Mode, type the PC's letter(s) you wish to select. Press Enter to accept.
Key Sequence Action
<Ctrl><Ctrl> x <Enter> Substitute jc with the active PC channel desired.
Example
1. <Ctrl><Ctrl> C <Enter>
2. <CtrlxCtrl> B <Enter>
3. <Ctrl><Ctrl> AB <Enter>
Selects Channel C.
Selects Channel B.
Selects the Scout attached to Channel A on the base unit,
then selects Channel B on the cascaded unit.
Scanning PCs
The scanning feature allows you to automatically monitor, or scan, each PC in your Scout
system. If you use the keyboard during scanning, the scan will pause until you finish, then
resume with the next PC. The length of time each PC’s video remains on the screen, or dwell
time, can be changed at any time. Scanning will be halted if the Halt command is entered or if
another PC is selected. The following key sequences configure and control scanning.
Key Sequence
<Ctrl><Ctrl> Dnn <Enter>
<Ctrl><Ctrl> SG <Enter>
<Ctrl><Ctrl> SH <Enter>
Action
Configures the dwell time. Substitute nn with a value
from 2 to 60 seconds. The default value is 5 seconds.
Enables the scan Go command.
Enables the scan Halt command.
If you would like mouse and keyboard activity to suspend scanning, see the commands below.
Key Sequence
<Ctrl><Ctrl> M+ <Enter>
<Ctrl><Ctrl> M- <Enter>
Example
1. Ctrl><Ctrl> DIO <Enter>
2. <Ctrl><Ctrl> SG <Enter>
3. <Ctrl><Ctrl> SH <Enter>
Action
Mouse will suspend scanning.
Mouse will not suspend scanning, (default)
Each PC’s video will remain on the screen for 10 seconds
before the next channel is displayed.
Scanning begins with the current computer, then
continues to the next PC in sequence.
Scanning is halted until the Go command is issued again.

K E Y B O AR D C O M M A N D SUM M A R Y
To enter any keyboard command, first press and release the left Control Key , this is
represented by <Ctrl>. Then enter the command followed by any parameters you wish to
specify, for example the port number. Letter commands are not case sensitive, and are shown
in upper case for clarity only. Do not use the numeric keypad to enter any commands.
Key Sequence Action
<Ctrl><Ctrl> x <Enter> Selects an active channel via keyboard.
<Ctrl><Ctrl> Dnn <Enter> Configures the dwell time. Substitute nn with a value
from 2 to 60 seconds. The default value is 5 seconds.
<Ctrl><Ctrl> SG <Enter> Enables the scan Go command.
<Ctrl><Ctrl> SH <Enter> Enables the scan Halt command.
<Ctrl><Ctrl> M+ <Enter> Mouse will suspend scanning.
<Ctrl><Ctrl> M- <Enter> Mouse will not suspend scanning, (default)
<Ctrl><Ctrl> ZM <Enter> Resynchronises the mouse.
<CtrlxCtrl> MR <Enter> Resets a computer’s PS/2 mouse.
<Ctrl><Ctrl> MW <Enter> Resets a computer’s IntelliMouse.
<Ctrl><Ctrl> Kn <Enter> Sets keyboard scan set; n is a number 1 - 3.
<Ctrl><Ctrl> AV <Enter> Displays the current firmware version of the processors
inside your Scout unit. You must be either at a DOS
prompt or in a text editor/word processor to view this
information.

T RO U B LE SH O O T IN G
Scout Unit
__________________________________________
____________
Green channel LED not lit
a) Verify that the computer is powered on. Check the cabling between your CPU and Scout.
b) Verify that a keyboard works when plugged directly into your PC.
Unable to switch channels
Verify that all attached PCs are powered and correctly connected to the unit.
Video
No video
a) Verify the video cable between the CPU and Scout is connected to the selected port.
b) Verify the monitor cable is correctly connected to the Scout.
c) Power down the computer. Connect the monitor directly to the computer and power up
again. If the monitor does not operate correctly direct to the computer, try another monitor.
Mouse
___________________________________________________________
Mouse jumps or “hugs” screen
a) If the mouse has been hot-plugged while running in Windows, you may need to close and
restart Windows.
b) If the mouse still does not function, try the mouse resynchronisation command:
<Ctrl><Ctrl> ZM <Enter>.
Mouse is inoperable on one or more channels
a) Try the mouse reset command: <Ctrl><Ctrl> MR <Enter> for PS/2 mice,
<Ctrl><Ctrl>MW<Enter> for IntelliMouse.
b) Verify the cables from the computer to the Scout are connected properly.
c) Verify the mouse is plugged into the mouse port in the User Console area on the rear panel
of the unit.
d) Verify the computer works when a mouse connected directly. If not, try another mouse.
Keyboard
________________________________________________________
Keyboard is inoperable on one or more channels
a) Verify the cables from the PC to the Scout are connected properly. Verify the keyboard is
plugged into the keyboard port in the User Console area on the rear panel of the unit.
b) Verify the keyboard works properly connected directly to the computer. If not, try a
different keyboard. If the keyboard still does not function, turn on and off all computers.
Keyboard is inoperable after switching channels or characters on screen do not match
keyboard input
Try changing the keyboard scan set by using the keyboard command sequence: <Ctrl><Ctrl>
Kn <Enter>, where n is a scan set number 1-3.
Hot Plugging Scouts
If you hot-plug your cascaded Scout, you may experience a loss of mouse signal. Execute a
channel switch on the cascaded Scout to restore the signal.
WARNING: Avoid routing cable near fluorescent lights, air conditioning compressors,
or machines that may create electrical noise. For best quality video, use coax cable.
_________

SE R VIC E INFO RM ATIO N
Maintenance and repair
The unit does not contain any user-serviceable parts inside. Any malfunction of the unit
should be reported to a factory-authorised repair centre for service. Any discrepancies in the
operation of the unit according to this manual should be reported to the Technical Support
Department of Dakota Computer Solutions.
Technical support__________________________________________________
If you cannot determine the nature of a problem, please call Dakota Computer Solutions and
ask for Technical Support. If possible, call from a phone located near the unit we may be able
to solve your problem directly over the phone. If we cannot solve your problem, and
determine that the fault is in the unit, we will issue a Return Material Authorisation (RMA)
number that must appear on the outside of all returned products. The unit should be double-
packed in the original container, insured, and shipped to the address given to you by our
Technical Support representative. To speak to Technical Support, call (+44) 0181 452 8400
from 9:00am to 5:00pm, Monday to Friday.
Append!* V. Genera! sped Heal ions
SIZE 4.83 x 20.57 x 12.7 cm
(Height, Width, Depth) 1.9” x 8.1” x 5.0”
WEIGHT 550 g
1.2 lbs
ENVIRONMENT Operating Temperature: 5° - 40° C
Storage Temperature: -20° - 50° C
OPTIONAL POWER 6VDC@ 700 mA “Class 2” or “L.P.S.”
SUPPORTED HARDWARE CPU: IBM PC/AT, PS/2 and 100% compatibles
Video: VGA and SVGA
Max Resolution: 1600 x 1280 @ 80 Hz
PS/2 keyboard, PS/2 mouse, PS/2 IntelliMouse
AGENCY APPROVALS UL 1950, CSA C22.2 No. 950, EN60950 FCC part 15B,
EN55022, EN50082
Appendix R, Cables and accessories
Description Part No.
Cabling
Scout CPU Cable Set - High Resolution
SVGA, PS/2 Keyboard & PS/2 Mouse 1.8 m 2085-02P
SVGA, PS/2 Keyboard & PS/2 Mouse 3.0 m 2085-03P
AT Keyboard & Serial Mouse Adaptor Kit 2085-00S


Scout kvm switch™
DEUTSCH
Tastatur-, Monitor- und Maus-Umschalter
Installations- und Bedienungshandbuch

INSTALLATION
Standort des Scout_________________________________________________
Die Scout-Einheit sollte so nahe wie möglich am Rechner plaziert werden. Dies würde die
Länge der CPU-Kabel verringern und eine kostenminimierte und elegante Installation
ergeben.
Solange der Scout störungsfrei arbeitet und nicht in Zugriffreichweite stehen muss, kann per
Tastatur umgeschaltet werden. Um jedoch den aktuellen Port zu verifizieren oder zu anderen
Port zu schalten, verwenden dazu die Tasten auf der Frontseite des Geräts.
Anschluß_________________________________________________________
1. Tastatur, Monitor und Maus: Diese werden direkt mit der Scout-Einheit verbunden.
2. Rechner: Die jeweiligen CPU-Kabelsätze verbinden die Rechner mit der Scout-Einheit.
Jeder Rechner benötigt ein eigenes Kabelkit mit entsprechenden Anschlüssen am Rechner
(PS/2, AT/seriell). Die Kabelkits sollten mitbestellt werden, wenn Sie Ihr Scout-Gerät
erstehen.
3. Schließen Sie die Tastatur-, Monitor- und Mausanschlüsse des CPU-Kabelsatzes in eines
der bezeichneten Scout-CPU-Ports (auf der Rückseite des Scout-Geräts) an.
4. Schließen Sie die Tastatur-, Monitor- und Mausanschlüsse des CPU-Kabelsatzes in die
entsprechenden Rechnerports an.
5. Fahren Sie die Rechner hoch..
Ihr Scout-Umschalter ist nun mit den Werkseinstellungen bereit. Diese sind in der Liste der
Tastatur-Kommandos zusammengefasst.

Grundlagen
Die Rechner sollten einzeln oder alle zusammen hochgefahren werden. Dies wird durch die
grünen LED-Lämpchen angezeigt. Nach dem Hochfahren markiert eine kleine gelbes LED-
Lämpchen den aktuell ausgewählten Rechner. Andere PCs können nun ausgewählt werden.
Auswahl eines PCs
Es gibt zwei Arten, einen PC auszuwählen. Der eine ist über die Auswahl-Tasten. Dies wählt
den nächsten in der Reihe der Rechner aus. Der andere Weg ist über die Eingabe eine kurzen
Tastenkombination auf der Tastatur.
Betätigen Sie 2mal innerhalb einer Sekunde die <STRG>-Taste. Dies versetzt Ihren Scout in
den Kommando-Modus. Ihre Tastatur-LED sollte nun kurz blinken. Die dann folgenden
Zeichen interpretiert der Scout als seine Kommandos, bis Sie die ENTER-Taste (für das
Akzeptieren des Kommandos) oder die ESC-Taste (Ignorieren der Kommandos) betätigt
haben. Im Kommando-Modus geben Sie bspw. den Buchstaben des Rechners ein, den Sie
auswählen möchten. Akzeptieren Sie mit der ENTER-Taste.
T astenkombination
<Strg><Strg> x <Enter>
Beispiele
1. <Strg><Strg> C <Enter>
2. <Strg><Strg> B <Enter>
3. <Strg><Strg> AB <Enter>
Aktion
Substitute x with the active PC channel desired.
Wählt PortC.
Wählt Port B.
Kaskade: Wählt den Scout, der am Port A der Basis-
Einheit liegt - dann Port B der kaskadierten Einheit.
Scannen der Rechner (automatische laufende Rechnerwahl)
Das Merkmal des Scannens ist, daß Sie automatisch Ihre Rechner überwachen können - ohne
während des Vorgangs die Tastatur benutzen zu müssen. Sollten Sie dennoch die Tastatur
benutzen, dann pausiert der Scan-Vorgang bis Sie Ihre Unterbrechung beendet haben. Danach
wird der Scan mit dem nächsten Rechner fortgesetzt.
Die Zeit, in der jedes Rechnerbild auf Ihrem Monitor erscheint und verbleibt, kann zu jeder
Zeit verändert werden. Der Scan-Vorgang wird angehalten, wenn Sie das HALT-Kommando
geben oder ein anderer Rechner ausgewählt wird. Die folgenden Tastenkombinationen
konfigurieren und steueren den Scan-Vorgang.
T astenkombination
<Strg><Strg> Dnn <Enter>
<Strg><Strg> SG <Enter>
<Strg><Strg> SH <Enter>
Key Sequence
<Strg><Strg> M+ <Enter>
<Strg><Strg> M- <Enter>
Aktion
Verbleibe-Zeit (in Sekunden): Ersetzten Sie nn durch
einen Wert zwischen 2 und 60. Voreinstellung: 5
Scan GO
Scan H ALT
Soll das Aussetzen des Scan-Vorgang von Maus- und Tastaturaktivitäten abhängig sein, dann
gelten folgende Kommandos:
Action
Maus setzt den Scan aus.
Maus setzt nicht den Scan aus. (voreingestellt)
Example
1. <Strg><Strg> D10 <Enter>
2. <Strg><Strg> SG <Enter>
3. <Strg><Strg> SH <Enter>
Jedes Rechnerbild verbleibt auf dem Bildschirm für 10
Sekunden, bevor der nächste Port angewählt wird.
Der Scan beginnt mit dem aktuellen Rechner, um dann
mit dem nächsten weiterzumachen.
Der Scan wird bis zum GO-Kommando angehalten.

I AS rA I U RKO.M M A \ DOS
Voraussetzung ist das Betätigen der linken <STRG>-Taste. Dann folgt das gewünschte
Tastaturkommando mit entsprechenden Parametern. Es wird nicht zwischen Groß- und
Kleinschreibung unterschieden. Benutzen Sie für die Eingabe von Ziffern bitte nicht den
Ziffemblock auf der rechten Seite Ihrer Tastatur, sondern stets die obere Ziffemreihe.
Tasten kombmation. Aktion
<Strg><Strg> x <Enter> Wählt einen aktiven Kanal aus.
<StrgxStrg> Dnn <Enter> Verbleibe-Zeit (in Sekunden): Ersetzten Sie nn durch
einen Wert zwischen 2 und 60. Voreinstellung: 5.
<Strg><Strg> SG <Enter> Scan GO.
<Strg><Strg> SH <Enter> Scan HALT.
<Strg><Strg> M+ <Enter> Maus setzt den Scan aus.
<Strg><Strg> M- <Enter> Maus setzt den Scan nicht aus (voreingestellt)
<Strg><Strg> ZM <Enter> Resynchronisieren der Maus.
<Strg><Strg> MR <Enter> Reset einer PS/2-Maus.
<Strg><Strg> MW <Enter> Reset einer IntelliMouse.
<Strg><Strg> Kn <Enter> Tastatur-Scan-Set: n ist eine Zahl zwischen 1 und 3.
<Strg><Strg> AV <Enter> Zeigt die aktuelle Firmware-Version des Scout-
Prozessors. Dazu sollten Sie entweder auf Systemebene
oder in einen Texteditor schalten. Dort kann die
Ausgabe der gewünschten erfolgen.

FKHLKRBKHKBIINC
Scout-Einheit
Das grüne LED leuchtet nicht
a) Stellen Sie sicher, daß der Rechner eingeschaltet ist. Überprüfen die Verkabelung
zwischen zwischen dem Scout und dem Rechner.
b) Überprüfen Sie die Funktion Ihrer Tastatur, indem Sie sie direkt mit dem Rechner
verbinden.
Die Umschaltung erfolgt nicht
Stellen Sie sicher, daß alle Rechner ordnungsgemäß mit dem Scout verbunden sind.
Videobild
Kein Bild
a) Überprüfen Sie das Monitorkabel zwischen dem Rechner und dem Scout.
b) Überprüfen Sie das Monitorkabel zwischen Monitor und dem Scout.
c) Fahren Sie Ihren Rechner herunter. Verbinden Sie den Monitor direkt mit dem Rechner
und fahren ihn erneut hoch. Sollte das Problem noch immer bestehen, versuchen Sie es
mit einem anderen Monitor.
Maus
Die Maus springt
a) Haben Sie die Maus während einer Windows-Sitzung eingesteckt, dann starten Sie
Windows mit eingesteckter Maus erneut.
b) Re-Synchronisieren Sie Ihre Maus: <Ctrl><Ctrl> ZM <Enter>.
Die Maus arbeitet nicht an einem oder mehreren Ports
1. Maus Reset-Kommando: <Strg><Strg> MR <Enter> für PS/2-Maus,
<Strg><Strg>MW<Enter> für IntelliMouse.
2. Überprüfen Sie die Verkabelung zwischen Rechner und Scout.
3. Überprüfen Sie den Anschluß der Maus im “User Control”-Port des Scout.
4. Überprüfen Sie die Maus, indem Sie sie direkt mit dem Rechner verbinden.
Tastatur
Die Tastatur arbeitet nicht an einem oder mehreren Ports
a) Überprüfen Sie die Verkabelung zwischen Rechner und Scout. Überprüfen Sie den
Anschluß der Tastatur im “User Control”-Port des Scout.
b) Überprüfen Sie die Tastatur, indem Sie sie direkt mit dem Rechner verbinden. Sollte das
Problem noch immer bestehen, starten Sie alle Rechner erneut.
Die Tastatur arbeitet nach dem Umschalten nicht oder nicht ordnungsgemäß
Verändern Sie den Tastatur-Scan-Set: <Strg><Strg> Kn <Enter>, n zwischen 1-3.
Scout im laufenden Betrieb anschließen
Sollten Sie im arbeitenden System einen zusätzlichen Scout kaskadieren, werden Sie das
Maus-Signal verlieren. Führen Sie eine Umschaltung auf den kaskadierten Scout aus, um das
Signal wiederherzustellen.
WARNUNG: Vermeiden Sie es bitte, die Kabel in die Nähe von Leuchtstoffröhren,
Klimaanlagen oder elektro-magnetischen Felder zu verlegen.
______________
____________
QT]

SK R VICK IINFORMATION
Wartung und Reparaturen
Das Gerät enthält keine Teile, die vom Benutzer repariert werden könnten oder müßten. Jede
Fehlfunktion des Gerätes sollten Sie Dakota Computer Solution Berlin mitteilen.
Technische Unterstützung
Falls Sie einen Fehler nicht lokalisieren oder beheben können, rufen Sie bitte Dakota
Computer Solutions an und fragen nach der technischen Unterstützungabteilung. Falls
möglich, rufen Sie bitte von einem Telefon in der Nähe des Gerätes an. Oftmals ist es
möglich, daß wir Ihr Problem direkt über das Telefon lösen können. Falls dies nicht der
Fall sein sollte und es sich herausstellt, daß das Gerät defekt ist, erhalten Sie von uns eine
Rückgabenummer. Rücksendungen ohne Rückgabenummer werden nicht akzeptiert. Bitte
versenden Sie die defekten Produkte nur in der Originalverpackung mit einer
Transportversicherung zu der Adresse, die Ihnen unsere technische Unterstützungs
abteilung mitteilt.
Sie können unsere technische Unterstützunsabteilung Montags bis Freitags von 9:00 bis 17:00
Uhr unter der Nummer (+49) 030 8595 37-0 erreichen.
Anhan« A. Allgemeine Spezifikationen
Maße (Höhe, Breite, Tiefe) 4.83 x 20.57 x 12.7 cm
Gewicht 550 g
Umgebungsfaktoren Betriebstemperatur: 5° - 40° C
Lagerungstemperatur: -20° - 50° C
Optionale Stromversorgung 6VDC @ 700 mA “Class 2” oder “L.P.S.”
Unterstützte Hardware Rechner: IBM PC/AT, PS/2 und 100% kompatible
Video: VGA und SVGA
Max Auflösung: 1600 x 1280 @ 80 Hz
PS/2 Tastatur, PS/2 Maus, PS/2 IntelliMaus
Richtlinien-Prüfungen UL 1950, CS A C22.2 No. 950, EN60950 FCC Teil 15B,
EN55022, EN50082
Anhang B. Kabel und Zubehör
Beschreibung
Kabel
ArtikelNr.
Scout CPU Kabelsatz - Hohe Auflösung
SVGA, PS/2 Tastatur & PS/2 Maus 1.8 m 2085-02P
SVGA, PS/2 Tastatur & PS/2 Maus 3.0 m 2085-03P
AT Tastatur & serielle Maus Adapter Kit 2085-00S


Computer Solutions
4 Harp Business Centre
Apsley Way
London NW2 7LW
England
Tel: +44 (0)20 8438 3800
Fax: +44 (0)20 8438 3899
1579 Lexington Road
Green Oaks. IL 60048
USA
info-us@dakota-euro. com
Tel: +1 847 816 1337
Fax +1 847 816 4558
Distribution Centre
Shannon Free Zone
Co. Clare
Ireland
info-ie@dakota-euro.com
Tel:+353 (0)61 70 4000
Fax. +353 (0)61 70 4099
Francisco De Vitoria 19 Ent
50008 Zaragoza
Spain
info-es@dakota-euro.com
Tel: +34 976 210 256
Fax: +34 976 219 943
Salzufer 16, Geb. B
D-10587 Berlin
Germany
info-de@dakota-euro.com
Tel: +49 (0)30 8595 37-0
Fax: +49 (0)30 8595 37-99
Udviklingsparken
Sonderhoj 46
8260 VibyJ
Denmark
info-dk@dakota-euro. com
Tel:+ 45 (0)8734 5610
Fax: +45(0)8734 5611
http://www.dakota-euro.com
Table of contents
Languages:
Other Dakota Computer Solutions Switch manuals
Popular Switch manuals by other brands

Leviton
Leviton decora smart DW15S installation instructions

Razberi
Razberi MP Series user manual

Speaka Professional
Speaka Professional SP-HDS-210 operating instructions

Leviton
Leviton 1080 Quick start manual

TP-Link
TP-Link JetStream L2 Lite TL-SG3210 user guide

Allied Telesis
Allied Telesis 8100L Series installation guide