Danatronics ECHO FD User manual

Ver:1.0A
Quick Start Guide for ECHO FD
ECHO FD Ultrasonic Flaw Detector

Danatronics, Corp.
2
Liability
Ultrasonic testing is a function of using the proper equipment (electronics, transducer,
cable and couplant combination) for the inspection and a qualified operator who knows
how to use this manual, the instruments and all calibration procedures. The improper use
of this equipment, along with the improper calibration can cause serious damage to
components, factories, facilities, personal injury, and even death. ALL DANATRONICS
ULTRASONIC THICKNESS GAGES ARE NOT INTRINSICALLY SAFE AND
SHOULD NOT BE USED IN ANY HAZEDOUS OR EXPLOSIVE AREAS.
It is understood that the operator of this equipment is a well trained inspector qualified by
either their own company or another outside agency to issue Ultrasonic Level I, 40 hour
class room training in Ultrasonic Theory. Danatronics, Corp. and any of its employees or
representatives shall not be held responsible for improper use of this equipment for its
intended use. Proper training, a complete understanding of Ultrasonic wave propagation,
thorough reading of this manual, proper transducer selection, correct zeroing of the
transducer, correct sound velocity, proper test blocks, proper cable length, proper
couplant selection all play a factor in successful ultrasonic thickness gaging. Special care
should be taken when test pieces have rough or painted surfaces, particularly those
applications where the test piece is thin to begin with as doubling of the echoes is
possible even if the transducer is capable of measuring the desired thickness. As
transducers wear or heat up, results can be either too thin due to a lack of sensitivity as a
result of wear or too thick due to heating up of the transducer, referred to as “drift.”

ECHO FD Ultrasonic Flaw Detector
3
Table of Contents
!"#$"%"&'())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(*!
+(,-&&"./(0&-2()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(3!
4$56&(&7-(89:;(0-1"-<())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(3!
*(=#<">(;?-1#&"5.<()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(@!
A5B-1(;.(&7-(C."&()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(@!
D-'?#2(E6.>&"5.<())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(F!
=#&&-1'(A#>G())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(H!
I5."&51"./(&7-(=#&&-1'(97#1/-(J15K(&7-(L"<?%#'(0>1--.())))))))))))))))))))))))))))))))))))))))))))))))))))))(H!
M-N>7#1/"./(&7-(=#&&-1'()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(O!
C<"./(P5.N1->7#1/-#$%-(44(=#&&-1"-<()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(+Q!
=55&R(=#"%R(#.2(0&1#?(E-#&61-<())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(+Q!
A%#>"./(&7-(=55&(5.(&7-(C."&()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(++!
M-K5S"./(&7-(=55&(J15K(&7-(C."&()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(++!
C<"./(&7-(=55&(0&1#?(#.2(=#"%()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(++!
;&7-1(C."&(E-#&61-<())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(++!
C<"./(&7-(TUM(+(#.2(TUM(*(A51&<())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(++!
!5>#&"./(&7-(C0=(0%5&()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(++!
C<"./(&7-(4>>-<<51'(I56.&())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(++!
!5>#&"./(&7-(4%&"&62-(97#./-(M-%-#<-(M-/6%#&51()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(++!
89:;(EL(C<-1(V.&-1J#>-())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(++!
A#1#K-&-1(;S-1S"-B())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(+3!
Gain!......................................................................................................................................!15!
Frequency!............................................................................................................................!15!
Measurement!Mode!............................................................................................................!16!
Reject!...................................................................................................................................!16!
Rectification!.........................................................................................................................!16!
Gate!1!Start!..........................................................................................................................!17!
Gate!1!Width!........................................................................................................................!17!
Gate!1!Level!.........................................................................................................................!18!
Gate!1!Alarm!........................................................................................................................!18!
Gate!1!Auto!80!.....................................................................................................................!18!
Gate!2!Start!..........................................................................................................................!19!
Gate!2!Width!........................................................................................................................!19!
Gate!2!Level!.........................................................................................................................!20!
Gate!2!Alarm!........................................................................................................................!20!
Gate!2!Auto!80!.....................................................................................................................!20!
Zero!......................................................................................................................................!21!
Velocity!................................................................................................................................!21!
Angle!....................................................................................................................................!22!
Thickness!..............................................................................................................................!22!
Energy!..................................................................................................................................!22!
DAC!......................................................................................................................................!23!
Curve!....................................................................................................................................!23!
DAC!Gain!..............................................................................................................................!24!
Range!...................................................................................................................................!24!

Danatronics, Corp.
4
Delay!....................................................................................................................................!24!
Gate!1!Detection!..................................................................................................................!25!
Gate!2!Detection!..................................................................................................................!25!
Measurement!Box!2!.............................................................................................................!25!
Measurement!Box!3!.............................................................................................................!26!
Measurement!Box!1!.............................................................................................................!26!
ID!..........................................................................................................................................!26!
Peak!Memory!.......................................................................................................................!27!
L"<?%#'(0>1--.())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(*F!
I5."&51"./(&7-(=#&&-1'(97#1/-(J15K(&7-(L"<?%#'(0>1--.()))))))))))))))))))))))))))))))))))))))))))))))))))))(*O!
W(9#%"$1#&"./(&7-(89:;(EL(J51(95.&#>&(T1#.<26>-1<())))))))))))))))))))))))))))))))))))))))))))))))))))(WQ!
X-%5>"&'(9#%"$1#&"5.(;.%'())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(W+!
Y(89:;(EL(9#%"$1#&"5.<())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(W*!
4./%-(=-#K(9#%"$1#&"5.())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(WY!
0-&&"./(M-J-1-.>-(,#".()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(WH!
0-&&"./(M-J(,#".(0&-?())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(WO!
3(8>75(EL(#2S#.>-2(<5J&B#1-(J-#&61-<()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(YQ!
4Z0(LN1#&"./())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(YQ!
0-&&"./(,#&-(4%#1K<())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(Y+!
A5<"&"S-(,#&-(4%#1K())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(Y+!
P-/#&"S-(,#&-(4%#1K())))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(Y*!
I"."K6K(L-?&7(4%#1K()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(Y*!
0&51-2(<-&6?<()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(YW!
L49([L"<&#.>-(4K?%"&62-(9511->&"5.(961S-<\(,CV()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(Y3!
@(T->7.">#%(4<<"<&#.>-()))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))(YF!

ECHO FD Ultrasonic Flaw Detector
5
1 Getting Started
About the ECHO Series
ECHO FD is a portable ultrasonic flaw detector in the same field-proven case as our
popular ECHO series, and it represents a breakthrough in terms of cost, size, ease of use,
and versatility. ECHO FD can even toggle from an every day flaw detector to a corrosion
or precision thickness gage making it the smallest and most affordable unit in the world
to offer such a vast application set. Our new hand-held ultrasonic flaw detector is packed
with many useful and practical features including:
Ø3.5" sunlight readable display with color pallet
ØChange color and vibrate on alarm
Ø2 independent gates
ØDAC
ØAWS
ØAPI-5UE
ØPeak Memory
Ø2GB, expandable to 32GB, micro SD card memory
ØDatalogger including B-scan and export of reading to excel
Ø13 hour battery life
ØCustom rubber boot with padded wrist strap and bail
ØMade and designed in the USA

Danatronics, Corp.
6
2 Basic Operations
Make sure the connector is plugged into TR 2 when using a single element probe.
Power On the Unit
To power on any ECHO FD, follow these steps:
1. Press and hold the F1 key for more than 3 seconds. The power symbol, as shown
below, is under the F1 key printed on the keypad.
2. After powering on the ECHO FD, the unit will display the last instrument settings
as well as the battery life in the bottom right corner. The image below shows the
battery life at 49%.
Note: Set your parameters based on the type of probe you are using.
3. Press the MENU/OK key and use the up and down arrow keys to select the
Setups option. Press the MENU/OK key again.
4. In the Setups menu, use the up and down arrow keys to select the probe closest to
the one you will be using. If none of the options are close, then press the F1 –
Exit key to set your own parameters.
Power symbol
under the F1 key

ECHO FD Ultrasonic Flaw Detector
7
ECHO FD has 4 default setup template files that cannot be deleted. They are as follows:
1. Straight beam contact probe 5 MHz, 5" range
2. Dual probe 5 MHz on a 0.100-0.500" (2.52-12.7mm) test block
3. Angle beam AWS type 2.25 with ref gain on
4. Angle beam quick change 5 MHz, 45 degree
To get started, we recommend that you choose a setup close to what you will be using.
This will allow you to get echoes and make smaller adjustments when fine-tuning your
setups and calibrations. As stated, the default setups cannot be deleted. Once a new
custom setup is saved (1,800 max.), you can also use the included Data XL interface
program to save them on your computer and even send the setups to additional ECHO
FDs.
Keypad Functions
The figure below shows the full keypad layout representative of each ECHO series unit.

Danatronics, Corp.
8
The following table refers to each key or symbol shown on the keypad. Note, the F keys
correspond to text above each key and prompts change depending on which screen you
are adjusting.
Key
Function
Up arrow key
Down arrow key
Left arrow key
Right arrow key
On/Off symbol (under the F1 key)
MENU/OK key
F1
Varies
F2
Varies
F3
Varies
F4
Varies
Function keys, or F keys (e.g., F1, F2, F3, F4), have various unit functions and may
change depending on the display screen. View the bottom of the display screen for the
function that corresponds with the appropriate F key. For example, F1 may correspond
with the Save function, F2 with the Freeze function, or F3 with the Directory function
Battery Pack
To ensure the highest level of performance and protection, the battery compartment is
separated from the electronic components of the unit.
Monitoring the Battery Charge from the Display Screen
The ECHO unit continuously displays the percentage of battery life remaining on the
bottom right corner of the measurement display screen. When the battery life is below
10%, the battery indicator will turn from green to red. When the battery life is below 5%,
the indicator will flash.
Note: Power off the ECHO unit to ensure any saved data is stored internally.

ECHO FD Ultrasonic Flaw Detector
9
Re-charging the Battery
To re-charge the battery, simply plug in the charger to an AC outlet (between 100-240V)
and plug the other end into the USB connector on the top of the ECHO series unit. The
F4 key will light up with a blue LED when charging, and the light will go out when fully
charged. Allow several hours (up to 10 hours) to fully charge. We recommend using the
charger and high-quality USB cable that is supplied with the ECHO unit. Using lower
quality USB cables can result in little or no charge.
Note: It is possible to use a computer to charge the unit, but this will take significantly
more time than using an AC outlet and we do not recommend it; however, if you decide
to charge the flaw detector using this method, make sure the unit is powered off before
you connect the USB to the computer and to the flaw detector itself.
When charging is complete, the F4 key will appear translucent in color. Power off the
flaw detector, and unplug the charger from the USB connector on the top of the unit.
Keep in mind, there is a battery indication monitor on the bottom right of the screen that
displays the percentage of battery life, as shown in the image below at 71%.
USB port

Danatronics, Corp.
10
Using Non-rechargeable AA Batteries
A non-rechargeable alkaline AA pack is also available. This option requires a spare tray
and 3 AA batteries. Follow these steps to insert non-rechargeable batteries:
1. Un-screw the battery door.
2. Disconnect the Li-Ion battery connector.
3. Plug in the AA tray connector.
4. Replace the battery door and tighten screws.
Note: When using the 3 AA battery tray, batteries cannot be re-charged.
Boot, Bail, and Strap Features
The custom rubber boot with built in bail and 4-point chest harness is an accessory for all
ECHO series units. Not only does the boot help to protect the unit from the elements, but
the functional bail and strap also offers a variety of positioning options.

ECHO FD Ultrasonic Flaw Detector
11
Placing the Boot on the Unit
To insert the unit into the rubber boot, follow these steps:
1. Guide the unit strap through the hole at the top of the boot (either right or left
side).
2. Slide the unit into the top of the boot.
3. Gently apply pressure to the bottom of the unit until it fully pops into the boot.
Removing the Boot from the Unit
Be sure that the bail is set in the open position before attempting to remove the boot.
Follow these steps:
1. Apply pressure to the bottom two corners of the boot until the unit pops out.
2. Wriggle the top section of the unit out of the boot.
3. Guide the unit strap through the hole at the top of the boot.
Using the Boot Strap and Bail
The boot strap is attached to the bail on the back of the boot. It can be used as a right- or
left-handed strap, or a finger strap. You can also connect the strap to a 4-point chest
harness for hands-free use.
The bail, including the straps, can be removed from the boot. This is useful when adding
accessories or locating the unit’s serial number. Simply open the bail and apply gentle
pressure to one side of the connector, which is located at the top of the bail. The piece
will pop off exposing the accessory mount (see below) and unit serial number.
Other Unit Features
Using the T/R 1 and T/R 2 Ports
On the top of the ECHO series units are two ports for transducer connectivity.
If you are using a dual element transducer, you may use either port—T/R 1 or T/R 2—
interchangeably. However, if you are using a single element transducer, plug the
connector into the T/R 1 port only.
Locating the USB Slot
The ECHO series units are furnished with a USB 2.0 slot on the top of the unit. Use the
USB slot to connect AC chargers or to connect to a computer for cross-functionality.
Using the Accessory Mount
On the back of the unit is a ¼x 20 accessory mount. This connector point is compatible
with a multitude of accessories including a magnetic pipe attachment and a Gorilla Pod.
Locating the Altitude Change Release Regulator
At the bottom of the unit is a circular outline with small holes. This feature regulates
pressure due to altitude change. Any pressure built up inside the unit will be
automatically released.
ECHO FD User Interface
Press and hold the F1 key to power on the unit. The following Display screen will appear
for 5 seconds.

Danatronics, Corp.
12
Display screen shows remaining battery life
The Measurement screen will appear following the Display screen. There are five
Measurement screens as shown below. Use the F4 – DISP MD key to toggle the screen
between display modes.
Display Mode 1
Display Mode 2

ECHO FD Ultrasonic Flaw Detector
13
Display Mode 3
Display Mode 4 (Scan Mode)
Note: You cannot use the left or right arrow keys to edit any parameter in the scanning
mode screen. The parameter in the large measurement box (e.g., soundpath
measurement of 0.498" shown above) will be displayed in the top right corner of the
screen. To change a parameter, press the F4 – DISP MD key.
Display Mode 5
Similar to ECHO 9 and ECHO 7, the left and right arrow keys will activate editing of the
parameters. A parameter that is highlighted will be active to edit by using the up and
down arrow keys. The right arrow key will select parameters in a clockwise direction and

Danatronics, Corp.
14
the left arrow key will select parameters in a counter clockwise direction. Red-circled
parameters, shown below, will be editable. This screen also represents the default screen
because it allows full instrument operation while showing the largest A-scan. This screen
will appear 10 seconds after the Parameter screen is displayed upon powering on the
unit. To change the Display mode, simply press the F4 – DISP MD key.
Color Waveform in Echo-to-Echo mode, filename, ID, thickness value, gain, rectification, battery
life, alarm, freeze, backlight, and display mode.
Press the left or right arrow key to activate the Parameter Edit mode. Once active, you
can scroll through the list using the left or right arrow key and then use the up and down
arrow keys to make adjustments. When finished, press the F1 – Done key to end editing
or the F4 key to select the next set of parameters. The list will toggle the right side
parameter list in following order:

ECHO FD Ultrasonic Flaw Detector
15
Parameter Overview
ECHO FD Ultrasonic Flaw Detector has many parameters that can be edited by using the
functions keys. Note, the function keys will vary depending on the current screen in use.
Below is an overview of editable parameters for ECHO FD and how the function keys
work for each relevant screen.
Note: Some of the below F1, F2, F3 and F4 screen shots are subject to change with
software updates.
Gain
•F1: Done (exit edit mode)
•F2: Gate 1 Auto 80 – set signal within Gate 1 amplitude to 80% by adjusting
gain automatic
•F3: Toggle Ref Gain On/Off. If Ref Gain is active, then Ref Gain and
Scanning Gain will appear as follows:
Also F2 will become ADD. In this situation when F2 is pressed, Ref Gain and
Scanning Gain will be added and Scanning Gain will be deactivated.
•F4: Next page of Gate 1 parameters
•Up/Down Arrow: Slew gain from 0.0 dB to 90.0 dB, and if Ref Gain is
active, the Up/Down arrow keys will slew Scanning Gain
•Right Arrow: Select Scanning Gain if Ref Gain is selected, or select Freq to
edit if Scanning Gain is selected
•Left Arrow: Select Peak to edit if you are in Gain or Ref Gain and if
Scanning Gain is selected
•MENU/OK: Go to Menu to set the Gain parameters
Frequency
•F1:Done (exit edit mode)
•F2:Cycle through fixed list of frequencies: 1.0M, 2.2M, 5.0M, 7.5M, 10.0M,
12.0M
•F3: None
•F4: Next page of Gate 1 parameters

Danatronics, Corp.
16
•Up/down Arrow: Slew frequency from 1.0MHz to 12.0 MHz
•Right Arrows: Select Measurement mode to edit
•Left Arrows: If Ref Gain is on, then select Scanning Gain or else select Gain
to edit
•MENU/OK: Go to Menu to set the Frequency parameters
Measurement Mode
•F1:Done (exit edit mode)
•F2:None
•F3:None
•F4:Next page of Gate 1 parameters
•Up/Down Arrow: Cycle thru P/E, THRU, DUAL
•Right Arrow: Select Reject to edit
•Left Arrow: Select Frequency to edit
•MENU/OK: Go to Menu to set Measurement mode parameters
Reject
•F1: Done (exit edit mode)
•F2:None
•F3:None
•F4:Next page of Gate 1 parameters
•Up/Down Arrow: Slew 0 to 85%
•Right Arrow: Select Rectification to edit
•Left Arrow: Select Mode to edit
•MENU/OK: Go to Menu to set Reject parameters
Rectification
•F1:Done (exit edit mode)

ECHO FD Ultrasonic Flaw Detector
17
•F2: None
•F3: None
•F4: Next page of Gate 1 parameters
•Up/Down Arrow: Cycle thru FULL, HW+, HW-, RF
•Right Arrow: Select Range to edit
•Left Arrow: Select Reject to edit
•MENU/OK: Go to Menu to set Rectification parameters
Gate 1 Start
•F1: Done (exit edit mode)
•F2: None
•F3: None
•F4: Next page of Gate 2 parameters
•Up/Down Arrow: Slew Gate 1 Start value from Delay up to (Delay + Current
Range)
•Right Arrow: Select Gate 1 Width to edit
•Left Arrow: Select Peak to edit
•MENU/OK: Go to Menu to set Gate 1 Start parameters
Gate 1 Width
•F1: Done (exit edit mode)
•F2: None
•F3: None
•F4: Next page of Gate 2 parameters
•Up/Down Arrow: Slew Gate 1 Width value from 0.010" to (Delay + Current
Range)
•Right Arrow: Select Gate 1 Level to edit
•Left Arrow: Select Gate 1 Start to edit
•MENU/OK: Go to Menu to set Gate 1 Width parameters

Danatronics, Corp.
18
Gate 1 Level
•F1:Done (exit edit mode)
•F2: None
•F3: None
•F4: Next page of Gate 1 parameters
•Up/Down Arrow: Slew Gate 1 Level value from 2% to 95%
•Right Arrow: Select Gate 1 Alarm to edit
•Left Arrow: Select Gate 1 Width to edit
•MENU/OK: Go to Menu to set Gate 1 Level parameters
Gate 1 Alarm
•F1: Done (exit edit mode)
•F2: None
•F3: None
•F4: Next page of Gate 2 parameters
•Up/Down Arrow: Toggle options: OFF, POS, NEG, MIN DEPTH if DAC is
inactive
OFF, POS, NEG, MIN DEPTH, ASME if DAC = ASME
OFF, POS, NEG, MIN DEPTH, 0 dB, -6 dB, -14 dB if
DAC = ASME3
OFF, POS, NEG, MIN DEPTH, RL, SL, EL if DAC =
CUSTOM
•Right Arrow: Select Gate 1 Auto 80 to set
•Left Arrow: Select Gate 1 Level to edit
•MENU/OK: Go to Menu to set Gate 1 Alarm parameters
Gate 1 Auto 80

ECHO FD Ultrasonic Flaw Detector
19
•F1: Done (exit edit mode)
•F2: Perform Auto 80
•F3: None
•F4: Next page of Gate 2 parameters
•Up/Down Arrow: None
•Right Arrow: Select Range to set
•Left Arrow: Select Gate 1 Alarm to edit
•MENU/OK: None
Gate 2 Start
•F1: Done (exit edit mode)
•F2: None
•F3: G2 OFF or ON
•F4: Next page of parameters
•Up/Down Arrow: Slew Gate 2 Start value from Delay up to (Delay + Current
Range)
•Right Arrow: Select Gate 2 Width to edit
•Left Arrow: Select Peak to edit
•MENU/OK: Go to Menu to set Gate 2 Start parameters
Gate 2 Width
•F1: Done (exit edit mode)
•F2: None
•F3: G2 OFF or ON
•F4: Next page of Parameters
•Up/Down Arrow: Slew Gate 2 Width value from 0.010" to (Delay + Current
Range)
•Right Arrow: Select Gate 2 Level to edit
•Left Arrow: Select Gate 2 Start to edit
•MENU/OK: Go to Menu to set Gate 2 Width parameters

Danatronics, Corp.
20
Gate 2 Level
•F1: Done (exit edit mode)
•F2: None
•F3: G2 OFF or ON
•F4: Next page of parameters
•Up/Down Arrow: Slew Gate 2 Level value from 2% to 95%
•Right Arrow: Select Gate 2 Alarm to edit
•Left Arrow: Select Gate 2 Width to edit
•MENU/OK: Go to Menu to set Gate 2 Level parameters
Gate 2 Alarm
•F1: Done (exit edit mode)
•F2: None
•F3: G2 OFF or ON
•F4: Next page of parameters
•Up/Down Arrow: Toggle options: OFF, POS, NEG, MIN DEPTH if DAC is
OFF
OFF, POS, NEG, MIN DEPTH, ASME if DAC = ASME
OFF, POS, NEG, MIN DEPTH, 0 dB, -6 dB, -14 dB if
DAC = ASME3
OFF, POS, NEG, MIN DEPTH, RL, SL, EL if DAC =
CUSTOM
•Right Arrow: Select Gate 2 Auto 80 to set
•Left Arrow: Select Gate 2 Level to edit
•MENU/OK: Go to Menu to set Gate 1 Alarm parameters
Gate 2 Auto 80