Danby DKC054A1BSL2DB User manual

DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9
DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840
OWNER’S MANUAL
MANUEL DU PROPRIÉTAIRE
MANUAL DEL PROPIETARIO
www.Danby.com
MODEL • MODÈLE • MODELO
DKC054A1BSL2DB
KEG COOLER
Owner’s Manual.............................1 - 14
GLACIÈRE DE BIÈRE PRESSION
Manuel du propriétaire.................15 - 28
BARRIL REFRIGERADOR
Manual del propietario.................29 - 42
2018.07.04

1
2
3
4
1. Pressure gauge dial
2. Pressure relief ring
3. Open / Close valve
4. Tank strap
Ensure the CO2tank is empty before courier or 3rd party transport.
DANGER - A full or partially full CO2tank is under extreme pressure. Uncontrolled
release of pressure is extremely dangerous. The instructions below use the regulator to
control the release of this pressure in a safe manner. Do not bypass the regulator.
1. Ensure tank is secure
2. Fully open valve by turning counter-clockwise. Pressure gauge dial will show a
value if tank contains pressure.
3. Gently pull pressure relief ring. Released gas should be heard.
4. The pressure dial will read zero when the tank is empty. Continue to hold pressure
relief open until tank is empty.
5. Release the pressure relief ring.
6. Fully close valve by turning clock-wise.
1

Welcome
Welcome to the Danby family. We are proud of our quality products and we believe in
dependable service. We suggest that you read this owner’s manual before plugging in your new
appliance as it contains important operation information, safety information, troubleshooting and
maintenance tips to ensure the reliability and longevity of your appliance.
Visit www.Danby.com to access self service tools, FAQs and much more. For additional assistance
call 1-800-263-2629.
Note the information below; you will need this information to obtain service under warranty.
You must provide the original purchase receipt to validate your warranty and receive service.
Model Number: _________________________________________________
Serial Number: _________________________________________________
Date of Purchase: _______________________________________________
Need Help?
Before you call for service, here are a few things you can do to help us serve you better.
Read this owner’s manual:
It contains instructions to help you use and maintain your appliance properly.
If you receive a damaged appliance:
Immediately contact the retailer or builder that sold you the appliance.
Save time and money:
Check the troubleshooting section at the end of this manual before calling. This section
will help you solve common problems that may occur.
1-800-26- Danby
(1-800-263-2629)
2

3
SAFETY REQUIREMENTS
DANGER: Risk of fire or explosion. Flammable
refrigerant used. Do not puncture refrigerant tubing.
• Do not use mechanical devices to defrost
refrigerator.
• Ensure that servicing is done by factory
authorized service personnel, to minimize
product damage or safety issues.
• Consult repair manual or owner’s guide before
attempting to service this product. All safety
precautions must be followed.
• Dispose of properly in accordance with federal
or local regulations.
• Follow handling instructions carefully.
WARNING: Keep ventilation openings, in the
appliance enclosure or in the built-in structure, clear
of obstruction.
WARNING: Do not use mechanical devices or other
means to accelerate the defrosting process, other
than those recommended by the manufacturer.
WARNING: Do not damage the refrigerant circuit.
WARNING: Do not use electrical appliances inside
the food storage compartments of the appliance,
unless they are of the type recommended by the
manufacturer.
CAUTION: Children should be supervised to ensure
that they do not play with the appliance.
DANGER: Risk of child entrapment. Before throwing
away an old appliance:
• Remove the door or lid.
• Leave shelves in place so that children may not
easily climb inside.
This appliance is intended to be used in household
and similar applications such as:
• Staff kitchen areas in shops, offices and other
working environments;
• Farm houses and by clients in hotels, motels and
other residential type environments;
• Bed and breakfast type environments;
• Catering and similar non-retail applications.
SAFETY REQUIREMENTS
This appliance is not intended for use by persons
(including children) whose physical, sensory or
mental capabilities may be different or reduced,
or who lack experience or knowledge, unless such
persons receive supervision or training to operate
the appliance by a person responsible for their
safety.
Do not store explosive substances such as aerosol
cans with a flammable propellant in this appliance.
GROUNDING INSTRUCTIONS
This appliance must be grounded. Grounding
reduces the risk of electrical shock by providing an
escape wire for the electrical current.
This appliance has a cord that has a grounding
wire with a 3-prong plug. The power cord must be
plugged into an outlet that is properly grounded.
If the outlet is a 2-prong wall outlet, it must be
replaced with a properly grounded 3-prong wall
outlet. The serial rating plate indicates the voltage
and frequency the appliance is designed for.
WARNING - Improper use of the grounding
plug can result in a risk of electric shock.
Consult a qualified electrician or service agent
if the grounding instructions are not completely
understood, or if doubt exists as to whether the
appliance is properly grounded.
Do not connect your appliance to extension
cords or together with another appliance in the
same wall outlet. Do not splice the power cord.
Do not under any circumstances cut or remove the
third ground prong from the power cord. Do not
use extension cords or ungrounded (two prongs)
adapters.
If the power supply cord is damaged, it must be
replaced by the manufacturer, its service agent or
similar qualified person in order to avoid hazard.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!

WARNING: CO2CAN BE DANGEROUS!
CO2Cylinders, when charged, contain high
pressure compressed gas which can be hazardous
if not handled properly. Read and understand the
following procedures for CO2cylinders before
installation:
1. Always check the D.O.T. (Department of
Transportation) as well as the T.C. (Transport
Canada) test date located on the neck of the
cylinder before installation. If the date is older
than five (5) years, do not use! Return the gas
cylinder to a gas supplier for re-certification
(service charges may be applicable).
2. Always connect a CO2gas cylinder to a
regulator. Failure to do so could result in an
explosion which can possibly result in death or
injury when the cylinder valve is opened.
3. Always follow correct procedures when cylinders
are changed as per local codes.
4. Always secure a CO2 gas cylinder in an
“upright” position.
5. Always keep a CO2gas cylinder away from
heat. Store extra cylinders in a cool place
(preferably 70°F/21°C). Securely fasten with a
chain in an upright position when storing.
6. Always ventilate and leave the area immediately
after any leakage of CO2.
7. Never connect a CO2gas cylinder directly to a
beer keg.
8. Never drop or throw a CO2cylinder.
9. Never connect a keg without at least one
safety pressure release. There are two safety
mechanisms in the pressure system;
• One at or on the CO2regulator.
• One at or on the product container coupler
in the pressure gas line.
Note: The regulator and keg coupler supplied
with this appliance are inclusive of such safety
mechanisms.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
WARNING: CO2CAN BE DANGEROUS!
If it becomes difficult to breathe and/or your head
starts to ache, abnormal concentrations of carbon
dioxide (CO2) may be present in the area.
CLOSE THE MAIN VALVE ON THE CO2CYLINDER,
VENTILATE AND LEAVE THE ROOM IMMEDIATELY!
Beer is easily available with Danby’s Keg Cooler,
however, it is not intended to be available to people
under the legal age to consume beer. Danby
does not assume liability for the unlawful use or
consumption of the beer.
PLEASE DRINK RESPONSIBLY AND PLEASE DON’T
DRINK AND DRIVE!
WARNING
CO2GAS CAN BE DANGEROUS
CO2cylinders contain high-pressure compressed
gas which can be hazardous if not handled
properly. Make sure to read and understand
all safety procedures for CO2cylinders before
installation.
4

BEFORE USING YOUR KEG COOLER
• Remove the exterior and interior packaging.
• Check to be sure you have all the following
parts:
• 2 guard rails
• 1 drip tray (2 pieces)
• 1 CO2tank support
• 1 CO2regulator
• 1 CO2tank (empty)
• 2 CO2gas line hose (coloured)
• 2 beer hose
• 2 beer keg couplers
• 1 beer tower
• 2 faucet handles
• 1 metal plate for cabinet bottom
• 3 wire shelves
• 2 steel clamps for coloured hose
• 2 plastic washers for front casters
• 4 casters (2 front with locks)
Note: This appliance includes an American Sankey
tap coupler only.
Note: This keg cooler accepts domestic kegs up to
16-1/8” in diameter and up to 23-3/8” in height.
Check with the distributor to make sure the keg is
correct size.
FEATURES
1. Beer Tower
2. Rubber Gasket (may not be required in all
configurations)
3. Guard Rail
4. Drip Tray
5. Thermostat dial
6. Keg Coupler
7. Beer Keg (not included)
8. Metal Support Plate
9. Casters
10.CO2 Regulator
11.CO2 Tank
12.CO2 Tank Support
1
2
34
5
7
8
9
10
11 12
6
INSTALLATION INSTRUCTIONS
INSTALLATION LOCATION
• Place the appliance on a floor that is strong
enough to support it when it is fully loaded.
• Do not place the appliance in direct sunlight or
near sources of heat, such as a stove or heater,
as this can increase electrical consumption.
Extreme cold ambient temperatures may also
cause the appliance to perform improperly.
• Do not use the appliance near water, for
example in a wet basement or near a sink.
• This appliance is intended for indoor use only. It
is not designed for outside installation, including
anywhere that is not temperature controlled
(garages, porches, vehicles, etc.).
• Before connecting the appliance to a power
source, let it stand upright for approximately
6 hours. This will reduce the possibility of a
malfunction in the cooling system from handling
during transportation.
• This appliance is intended for free-standing
installation only and is not intended to be
built into a cabinet or counter. Building in this
appliance can cause it to malfunction.
5

INSTALLATION DIAGRAM
1. CO2 regulator
2. CO2 gas tank
3. Coloured CO2hoses
4. Faucet assemblies
5. Tower
6. Clear hoses
7. Couplers
8. Kegs
INSTALLATION INSTRUCTIONS
1
2
3
4
5
6
7
8
CASTER INSTALLATION INSTRUCTIONS
Install the four casters. The two locking casters
should be placed at the front. Four screw holes have
been pre-drilled into the bottom of the cabinet at
each corner for each caster. Put the plastic washers
provided on the front casters before installing them.
CASTOR BRAKES
The two front casters are supplied with brakes to ensure the appliance does not move excessively while
being used. It is recommended to engage the brakes while the appliance is in use to avoid damage to the
appliance, the contents or personal property.
Step on to brake Step on to
release brake
6

INSTALLATION OF CO2 TANK SUPPORT
Install the metal support onto the four studs located
on the exterior back wall of the cabinet.
Align the holes in the support with the studs and
push down firmly.
INSTALLATION OF CO2 TANK AND CO2REGULATOR
The CO2tank does not come filled. The tank must be
filled with CO2before use.
Place the charged tank into the support stand.
Attach the CO2regulator to the tank by turning
the regulator nut onto the tank valve, making sure
the washer is securely inserted into the connecting
nut. Tighten snug using an adjustable wrench (not
supplied) and ensure there are no leaks, i.e. no
hissing sounds when the CO2is turned on.
INSTALLATION OF CO2 AIR LINE AND CONNECTION TO CO2REGULATOR
Remove the plug located at the exterior back of the
cabinet, in the top left hand corner. Save the plug
for later use convert the appliance to a refrigerator.
Feed the gas line through the cabinet and out
through the uncovered hole.
Attach the open end of the hose to the hose barb
connection on the regulator. Secure the hose
by using one clamp provided. Use pliers or a
screwdriver to tighten the clamp to prevent leaks.
INSTALLATION INSTRUCTIONS
7

INSTALLATION OF THE BEER TOWER
• Remove the plug from the top of the fridge
cabinet by twisting and pulling out. Save the
plug for later use to convert the appliance to a
refrigerator.
• Unravel the beer lines (clear hoses) from the
tower and insert the beer lines and wing nuts
through the uncovered hole on top of the
cabinet.
• Secure the beer tower assembly to the top of the
cabinet by pressing down and turning the tower
to lock in place. Ensure the faucet is aligned with
the front of the appliance.
• The rubber gasket can be used to make the
connection between the tower and the cooler
tighter if needed. If the beer tower will not turn
to lock in place, try removing the rubber gasket.
The rubber gasket may not be required in all
configurations.
Note: If the faucet is leaking or if the beer is very
foamy, ensure that the washers inside the faucet are
intact. Replace the washers with spare parts from
the accessory bag, if necessary.
1. Handle washer
2. Tap washer
3. Spout washer
INSTALLATION INSTRUCTIONS
FAUCET WRENCH
The provided faucet wrench is for either removing or tightening the faucet connection. If the beer is not
flowing freely, use the wrench to remove the faucet for cleaning. If the faucet connection is leaking, use the
wrench to tighten the faucet connection.
PLASTIC FAUCET HANDLE
Attach the black plastic handle to the top of the faucet. Hold the silver nut underneath so it does not turn.
If there is a small drip from the faucet, the silver nut may be overtightened. Unscrew silver nut counter-
clockwise by one turn.
INSTALLATION OF THE PROTECTIVE METAL PLATE
The protective metal plate should be installed on the bottom of the inside of the cabinet. This plate should
always be installed when a keg is in place to protect the floor of the cabinet from damage.
INSTALLATION OF THE BEER KEG
• Two people should lift the keg to avoid back injury
• Position the keg directly in front of the open door.
• Using the keg handles, lift the front of the keg just enough so the front end is resting on the front edge
of the keg cooler bottom cabinet.
• Grasp the keg handles and slide it all the way into the cabinet.
8

INSTALLATION OF THE KEG COUPLER
Insert the keg coupler into the locking neck of the
beer keg and turn it clockwise to lock into position,
making sure the keg coupler handle is in the closed
position, with the handle up.
1. Coupler pressure release valve
2. Handle in closed position
INSTALLATION OF THE CO2AIR LINE HOSE
Attach the end of the coloured air line hose to the hose connection on the side of the coupler. Ensure that
the reed valve is inserted into the connection, number 4 on the image below.
If, after assembly, beer will not flow, ensure that the reed valve has a small hole in it. If there is no hole in
the reed valve then CO2cannot enter the line and the beer will not flow.
1. Valve washer
2. Check valve
3. O-type washer
4. Reed valve
5. Valve washer
6. Valve washer
CONNECTING THE BEER TOWER TO THE COUPLER
• Ensure all washers are properly inserted into the coupler,
as per the below image.
• Ensure the check valve is in place inside the coupler,
number 2 on the below image.
• Place the wing nut attached to the end of the beer line
into the top of the coupler, turning until tight.
If, after assembly, the beer is very foamy, it most likely means
that a connection in the coupler is leaking and air is entering
the lines. Double check all connections in the coupler and
replace the washers from the accessory bag as necessary.
INSTALLATION INSTRUCTIONS
1
2
9

HOW TO TAP A KEG OF BEER
• Make sure the CO2is turned off and the valve
on the regulator is in the closed position.
• Pull out and release the pressure release valve
on the coupler to purge any air pressure.
• Make sure the faucet handle is in the closed
position.
• Pull the coupler handle out and downward until
it locks into its open position. The teeth on the
underside of the coupler will bite into the locking
neck of the beer keg.
Note: If a keg is very tall, it may be necessary to
connect the coupler to the keg before inserting the
keg into the keg cooler.
OPENING THE CO2TANK MAIN VALVE
• Make sure the secondary shut-off valve (shown below in “open” position) is closed. To open the main
CO2cylinder valve, slowly turn the main valve counter-clockwise until fully open.
• Notice the needle on the regulator gauge start to climb.
OPERATING INSTRUCTIONS
12
1. Coupler pressure release valve
2. Handle in open position
1. Connection to C02tank
2. Shut off valve (open position)
3. Lock nut
4. Adjustment screw
10
ADJUSTING THE CO2REGULATOR
The gauge monitors internal keg pressure and should be
adjusted to read between 8-12 PSI. The pressure can be
adjusted as needed. After making any adjustment to the PSI,
wait 5 - 10 minutes before attempting to pour another beer
to allow the pressure to equalize.
• If the beer is very foamy, try turning the pressure down.
• If the flow of beer is very weak, try turning the pressure
up.
1. Loosen the lock nut.
2. Turn the adjustment screw with a flat screwdriver.
• To increase pressure, turn screw clockwise.
• To decrease pressure, turn screw counter-clockwise.
3. Allow several minutes for the keg to properly pressurize
before adjusting the pressure further. The regulator
gauge may drop while this happens.
4. Retighten the lock nut to ensure the pressure does not get
adjusted accidentally.
Note: Listen for hissing along all connections to identify if
there are any leaks.
1
2
2
3
4

DISPENSING OF BEER
• Keep beer keg refrigerated at all times.
• Never allow beer lines to dry out.
• Use clean glassware before pouring.
• Hold glass at a 45° angle, when it is 2/3 full,
start to straighten glass as the glass fills.
• Always make sure the faucet handle is pushed
all the way back.
Note: The refrigerator compartment cannot
accommodate the “Coors” style beveled barrel keg.
Note: This keg cooler accepts domestic kegs up to
16-1/8” in diameter and up to 23-3/8” in height.
Check with the distributor to make sure the keg is
correct size.
Note: It is important to allow the keg to sit upright
and undisturbed, for 2 hours before tapping.
SETTING THE TEMPERATURE
The temperature is controlled by adjusting the
thermostat control knob.
• The thinnest part of the dial is the warmest
setting.
• The thickest part of the dial is the coldest setting.
• To turn off the cooling, rotate the control knob to
the “0” (OFF) position.
AUTOMATIC DEFROSTING
There is no need to defrost the keg cooler. Defrost
water collects and passes through the drain outlet
in the rear wall into a tray located above the
compressor, where it evaporates.
Note: If the appliance is unplugged, power lost or
turned off, wait 3 to 5 minutes before restarting the
appliance. If there is an attempt to restart before this
time delay, the compressor may not start.
CONVERTING TO A REFRIGERATOR
1. Turn the thermostat dial to the “OFF” position.
2. Close the main valve on the CO2cylinder.
3. Close the secondary shut-off valve on the
regulator pipe.
4. Close the connection between the beer keg and
the keg coupler.
5. Drain any remaining beer from the lines. (We
recommend cleaning at this point, please see
Care and Maintenance section).
6. Disconnect the beer line and CO2gas line from
the keg coupler.
7. Remove the beer keg.
8. Remove the keg coupler.
9. Disconnect the gas line from the CO2cylinder.
10.Remove the CO2gas line from cabinet plug.
11.Replace the gas line rear cabinet plug.
12.Remove the beer tower. Also pull the beer line
through the top of the cabinet.
13.Replace the top cabinet plug.
14.Adjust the temperature as desired.
Note: In order to convert the appliance, the gas line
must be disconnected from the regulator in order to
remove it from the cabinet.
Note: Install the shelf by sliding it into the desired
spot in the appliance.
OPERATING INSTRUCTIONS
11

OPERATING INSTRUCTIONS
DOOR REVERSAL INSTRUCTIONS
If the appliance is placed on its back or side for any
length of time during this process, it must be allowed
to remain upright for 6 hours before plugging it in
to avoid damage to internal components.
1. Remove the lower hinge from the bottom right
side of the cabinet. Remove the door from the
cabinet.
2. Remove the hinge pin from the upper right side
of the cabinet. Install it on the upper left side of
the cabinet.
3. Install the door on the cabinet and install the
lower hinge on the bottom right side of the
cabinet.
Note: Ensure the top of the door is level with the top
of the cabinet and that the rubber gasket is making
a good seal with the cabinet all the way around
before tightening the screws.
1
2
3
CLEANING THE KEG COOLER
• Turn the temperature control to “OFF”, unplug
the keg cooler, and remove the contents.
• Wash the inside surfaces with a warm water and
baking soda solution. The solution should be 2
tablespoons of baking soda to a quart of water.
• Wash the shelves and stand with a mild
detergent solution.
• Wipe down any electrical controls with a dry
cloth.
• Wash the outside cabinet with warm water and
mild liquid detergent. Rinse well and wipe dry
with a clean soft cloth.
CLEANING THE BEER LINES
Beer lines have to periodically be cleaned because
of a crystallized sugar build up which forms on
the fittings, lines and taps. If the build up is not
completely removed in a cleaning process it will
leave an unsanitary surface that can harbor
microorganisms which will cause an undesirable
flavour and/or cause the beer to go flat. Sufficient
build up will also lead to dispensing problems
ranging from foamy beer to flat beer, regardless of
the carbonation levels or the quality or age of the
beer in the keg.
Scheduled line and faucet cleaning eliminates the
build-up, protecting the integrity of the product and
condition of the dispensing system and seals. The
beer line should be cleaned and rinsed with hot
water approximately once every three weeks or
every other keg - which ever comes first. The faucet
should be cleaned with hot water on a weekly basis
or prior to every use if not used on a regular basis.
Note: If the faucet handle becomes stuck or hard
to move, this is usually indicative that it requires
cleaning. DO NOT apply force to move the handle
in this situation, as this can lead to damaging the
handle or faucet and will not be covered by the
warranty.
CARE & MAINTENANCE
12

TROUBLESHOOTING
Danby Consumer Care: 1-800-263-2629
Hours of operation:
Monday to Thursday 8:30 am - 6:00 pm Eastern Standard Time
Friday 8:30 am - 4:00 pm Eastern Standard Time
Information in this manual is subject to change without notice.
13
PROBLEM POSSIBLE CAUSE
The unit does not operate • Not plugged in
• The circuit breaker tripped or blown fuse
Turns on and off
frequently • The room temperature is hotter than normal
• The door is open too often
• The door is not closed completely
• The temperature control is not set correctly
• The door gasket does not seal properly
• The unit does not have proper clearance
Vibrations • Check that the keg cooler is level
The keg cooler seems to
make too much noise • The rattling noise may come from the flow of refrigerant, which is normal
• Gurgling, caused by liquid refrigerant cycling is normal
• Contraction and expansion of the inside walls may cause popping and
crackling noises
• The keg cooler is not level
The door will not close
properly • The keg cooler is not level
• The door was reversed and not properly reinstalled
• The gasket is dirty
• The shelves or stand are out of position
• The keg is not properly centered in the unit
• The casters are not attached
Excessive beer foam • Ensure the beer line hose from the tower and the CO2air line hose from
the CO2regulator are attached to the correct connections on the coupler;
beer line to the top of the coupler, CO2air line to the side of the coupler
• Check that there are no leaks in any connections
• Ensure that the reed valve in the CO2connection at the coupler has a
hole in it
• The CO2pressure may be set too high; try turning the pressure down
• Ensure that the check valve is inserted into the coupler
• Ensure the beer lines are clean
Weak beer flow • Ensure the beer line hose from the tower and the CO2air line hose from
the CO2regulator are attached to the correct connections on the coupler;
beer line to the top of the coupler, CO2air line to the side of the coupler
• Check that there are no leaks in any connections
• Ensure that the reed valve in the CO2connection at the coupler has a
hole in it
• The CO2pressure may be set too low; try turning the pressure up
• Ensure there are no bends or kinks in any of the hoses that could impede
fl o w
• Ensure the beer lines are clean

LIMITED IN-HOME APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating
conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter
“Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
First Year
During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the ORIGINAL purchaser.
To obtain
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance
Service
requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at
their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below.
Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service
must be performed by a qualied service technician.
If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all
obligations of Danby under this warranty shall be void.
Boundaries of
If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be
In Home Service
delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for
warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he
responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due
to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its
authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees
under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages
to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of
the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions
(extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application).
Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our
AUTHORIZED SERVICE DEPOT.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
04/09
1-800-263-2629
Warranty Service
In-home
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an authorized service
depot. Any appliance requiring service outside the limited boundaries of “In Home Service”, will be the consumer’s
responsibility to transport at their own expense to the original point of purchase or a service depot for repair. If the
appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center, it must
be delivered to the nearest authorized Danby Service Depot by the purchaser.
Transportation charges to and from the service location are not protected by this warranty and are the
responsibility of the purchaser.
During the first twelve (12) months, any functional parts of this product found to be defective, will be repaired or
replaced, at warrantor’s option, at no charge to the original purchaser.
Contact the dealer where the unit was purchased, or contact the nearest authorized Danby service depot, where
service must be performed by a qualified service technician. If service is performed on the unit by anyone other
than an authorized service depot, all obligations of Danby under this warranty shall be void.
First 12 months
To obtain service
Boundaries of
in-home service
LIMITED “IN HOME” WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used
under the normal operating conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby
Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts are warranted for thirty (30) days from the date of purchase, with no extensions provided.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other
contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, by Danby, there are no other warranties, conditions, representations or guarantees, express or implied, made
or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any
warranties, conditions, representations or guarantees under any Sale of Goods Act or like legislation or statute is hereby expressly
excluded. Save as herein provided, Danby shall not be responsible for any damages to persons or property, including the unit itself,
howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit, the
purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or property caused by
the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating
conditions (ie. extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor
application, including but not limited to: garages, patios, porches or anywhere that is not properly insulated or climate controlled).
Proof of purchase date will be required for warranty claims; retain bills of sale. In the event that warranty service is required, present
the proof of purchase to our authorized service depot.
Warranty Service
In Home
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
1-800-263-2629
04/17

1
2
3
4
1. Cadran de manomètre
2. Anneau de limitation de pression
3. Soupape de l’ouverture / fermeture
4. Sangle du réservoir
Vérifiez que le réservoir de CO2est vide avant de messagerie ou transport 3e
parti.
DANGER - Un réservoir plein ou partiellement plein de CO2est sous une pression
extrême. La libération incontrôlée de la pression est extrêmement dangereuse. Les
instructions ci-dessous utilisent le régulateur pour contrôler la libération de cette
pression de manière sûre. Ne contournez pas le régulateur.
1. Assurez-vous que le réservoir est bien fixé
2. Ouvrir complètement la soupape en tournant dans le sens anti-horaire. Le cadran
du manomètre indiquera une valeur si le réservoir contient de la pression.
3. Tirez doucement la bague de décharge de pression. Le gaz rejeté doit être
entendu.
4. Le cadran de pression indique zéro lorsque le réservoir est vide. Continuez à
maintenir le soulagement de pression ouvert jusqu’à ce que le réservoir soit vide.
5. Relâcher l’anneau de décharge de pression.
6. Fermez complètement la soupape en tournant dans le sens horaire.
15

16
Bienvenue
Bienvenue à la famille Danby. Nous sommes fiers de la qualité de nos produits et nous croyons au
service fiable. Nous vous suggérons de lire ce manual d’utilisation avant de brancher votre nouvel
appareil, car il contient des informations inportantes sur l’utilisation, la sécurité, le dépannage et
la maintenance, afin d’assurer la fiabilité et la longévité de votre appareil.
Visitez www.Danby.com pour accéder aux outils d’autoservice, aux FAQ et bien plus encore. Pour
obtenir de l’aide supplémentaire, composez le 1-800-263-2629.
Notez les informations ci-dessous; Vous aurez besoin de cette information pour obtenir un
service sous garantie.
Vous devez fournir le reçu d’achat original pour valider votre garantie et recevoir le service.
Numéro de modèle : _____________________________________________
Numéro de serie : _______________________________________________
Date d’achat : __________________________________________________
Besoin d’assistance?
Avant d’appeler pour le service, voici quelques choses que vous pouvez faire pour nous
aider à mieux vous servir.
Lire ce manuel du propriétaire :
Il contient des instructions pour vous aider à utiliser et à entretenir votre appareil
correctement.
Si vous recevez un appareil endommagé :
Contactez immédiatement le revendeur ou l’entrepreneur qui vous a vendu l’appareil.
Gagnez du temps et de l’argent :
Avant d’appeler pour le service, consultez la section de dépannage à la fin de ce
manuel. Cette section vous aidera à résoudre les problèmes courants pouvant survenir.
1-800-26- Danby
(1-800-263-2629)

EXIGENCES DE SÉCURITÉ
DANGER : Risque d’incendie ou d’explosion.
Liquide frigorigène inflammable utilisé. Ne pas
percer les tubes de réfrigérant.
• N’utilisez pas de dispositifs mécaniques pour
dégivrer le réfrigérateur.
• Assurez-vous que l’entretien est effectué par le
personnel de service autorisé en usine, afin de
minimiser les dommages sur les produits ou les
questions de sécurité.
• Consultez le manuel de réparation ou le guide
du propriétaire avant d’essayer de réparer
ce produit. Toutes les précautions de sécurité
doivent être respectées.
• Éliminer conformément aux règlements fédéraux
ou locaux.
• Suivez attentivement les instructions de
manutention.
AVERTISSEMENT : Garder les ouvertures de
ventilation, dans l’enceinte de l’appareil ou dans la
structure intégrée, sans obstruction.
AVERTISSEMENT : N’utilisez pas de dispositifs
mécaniques ou d’autres moyens pour accélérer
le processus de dégivrage, autres que ceux
recommandés par le fabricant.
AVERTISSEMENT : Ne pas endommager le circuit de
réfrigérant.
AVERTISSEMENT : N’utilisez pas d’appareils
électriques à l’intérieur des compartiments de
stockage d’aliments de l’appareil, à moins qu’ils ne
soient du type recommandé par le fabricant.
ATTENTION : Les enfants devraient être surveillés
pour s’assurer qu’ils ne jouent pas avec l’appareil.
DANGER : Risque de piégeage des enfants. Avant
de jeter un ancien appareil :
• Retirez la porte ou le couvercle.
• Laissez les étagères en place afin que les enfants
ne puissent pas facilement monter à l’intérieur.
Cet appareil est destiné à être utilisé dans des
applications domestiques et similaires telles que:
• Cuisines du personnel dans les magasins, les
bureaux et autres environnements de travail;
• Les maisons de ferme et par les clients dans les
hôtels, motels et autres environnements de type
résidentiel;
• Chambres d’hôtes;
• Restauration et applications similaires non
commerciales.
EXIGENCES DE SÉCURITÉ
Cet appareil n’est pas destiné à être utilisé par
des personnes (y compris des enfants) dont les
capacités physiques, sensorielles ou mentales
peuvent être différentes ou réduites, ou qui n’ont
pas d’expérience ou de connaissances, à moins que
ces personnes ne reçoivent de supervision ou de
formation pour faire fonctionner l’appareil par une
personne responsable de leur sécurité.
Ne pas stocker des substances explosives comme
les bombes aérosol avec un propulseur inflammable
dans cet appareil.
INSTRUCTIONS DE MISE À LA TERRE
Cet appareil doit être mis à la terre. La mise à
la terre réduit le risque de choc électrique en
fournissant un fil d’échappement pour le courant
électrique.
Cet appareil possède un cordon doté d’un fil de
mise à la terre avec une fiche à 3 broches. Le
cordon d’alimentation doit être branché sur une
prise correctement mise à la terre. Si la sortie
est une prise murale à 2 broches, elle doit être
remplacée par une prise murale à 3 broches
correctement mise à la terre. La plaque signalétique
en série indique la tension et la fréquence
auxquelles l’appareil est conçu.
AVERTISSEMENT - Une utilisation incorrecte de la
fiche de mise à la terre peut entraîner un risque
d’électrocution. Consultez un électricien qualifié
ou un agent de service si les instructions de mise
à la terre ne sont pas complètement comprises ou
s’il existe un doute quant à savoir si l’appareil est
correctement mis à la terre.
Ne branchez pas votre appareil à des rallonges
ou avec un autre appareil dans la même prise
murale. Ne pas épisser le cordon d’alimentation.
Ne coupez ou retirez en aucun cas la troisième
broche du cordon d’alimentation. N’utilisez pas de
cordons de prolongement ou d’adaptateurs sans
mise à la terre (deux broches).
Si le cordon d’alimentation est endommagé, il doit
être remplacé par le fabricant, son agent de service
ou une personne qualifiée similaire afin d’éviter tout
risque.
Consignes de sécurité importantes
LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ
GARDEZ CES INSTRUCTIONS!
17

ATTENTION: LE CO2PEUT ÊTRE
DANGEREUX!
Les bouteilles de CO2, lorsqu’elles sont chargées,
contiennent du gaz comprimé à haute pression
qui peut être dangereux s’il n’est pas manipulé
correctement. Lisez et comprenez les procédures
suivantes pour les bouteilles de CO2avant
l’installation:
1. Vérifiez toujours le D.O.T. (Département des
Transports) ainsi que le T.C. (Transports Canada)
date d’essai située sur le goulot de la bouteille
avant l’installation. Si la date est plus vieille
que cinq (5) ans, n’utilisez pas! Retourner la
bouteille de gaz à un fournisseur de gaz pour
une nouvelle certification (des frais de service
peuvent être applicables).
2. Toujours connecter une bouteille de gaz CO2
à un régulateur. Ne pas le faire pourrait
provoquer une explosion qui peut entraîner la
mort ou des blessures lorsque la soupape de la
bouteille est ouverte.
3. Toujours suivre les procédures correctes lorsque
les cylindres sont changés selon les codes
locaux.
4. Toujours fixer une bouteille de gaz CO2dans
une position «verticale».
5. Toujours garder une bouteille de gaz CO2
loin de la chaleur. Stocker les cylindres
supplémentaires dans un endroit frais (de
préférence 70 °F / 21 °C). Fixez solidement
avec une chaîne dans une position verticale lors
du stockage.
6. Toujours ventiler et quitter la zone
immédiatement après toute fuite de CO2.
7. Ne raccordez jamais une bouteille de gaz CO2
directement à un fût de bière.
8. Ne jamais laisser tomber ou jeter une bouteille
de CO2.
9. Ne branchez jamais un fût sans au moins un
déclencheur de sécurité. Il y a deux mécanismes
de sécurité dans le système de pression;
• Un à ou sur le régulateur de CO2.
• L’un au ou sur le coupleur de récipient
de produit dans la conduite de gaz sous
pression.
Remarque: Le régulateur et le coupleur de fûts
fournis avec cet appareil sont inclus de tels
mécanismes de sécurité.
ATTENTION: LE CO2PEUT ÊTRE
DANGEREUX!
S’il devient difficile de respirer et/ou si la tête
commence à faire mal, des concentrations
anormales de dioxyde de carbone (CO2) peuvent
être présentes dans la région.
FERMER LA VANNE PRINCIPALE SUR LE CYLINDRE
DE CO2, VENTILER ET LAISSER LA CHAMBRE
IMMÉDIATEMENT!
La bière est facilement disponible avec le
refroidisseur de Keg de Danby, cependant, il n’est
pas destiné à être disponible pour les personnes
n’ayant pas l’âge légal pour consommer de la
bière. Danby n’assume aucune responsabilité pour
l’utilisation illégale ou la consommation de la bière.
VEUILLEZ BOIRE RESPONSABLEMENT ET S’IL VOUS
PLAÎT NE PAS BOIRE ET CONDUIRE!
ATTENTION
ATTENTION: LE CO2PEUT ÊTRE DANGEREUX!
Les bouteilles de CO2contiennent du gaz
comprimé à haute pression qui peut être
dangereux s’il n’est pas manipulé correctement.
Assurez-vous de lire et de comprendre toutes les
procédures de sécurité pour les bouteilles de CO2
avant l’installation.
Consignes de sécurité importantes
LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ
GARDEZ CES INSTRUCTIONS!

AVANT D’UTILISER VOTRE REFROIDISSEUR DE FÛT
• Retirez l’emballage extérieur et intérieur.
•
• Vérifiez que vous avez toutes les pièces
suivantes:
• 2 garde-corps
• 1 bac d’égouttage (2 pièces)
• 1 support de réservoir de CO2
• 1 régulateur de CO2
• 1 réservoir de CO2(vide)
• 2 tuyau de ligne de gaz CO2(couleur)
• 2 tuyau de bière
• 2 coupleur de fût de bière
• 1 tour de bière
• 2 poignée de robinet
• 1 plaque métallique pour le fond de
l’armoire
• 3 étagères
• 2 pince en acier pour tuyau coloré
• 2 rondelles en plastique pour roulettes avant
• 4 roulettes (2 avant avec serrures)
Remarque: Cet appareil comprend un coupleur de
prise American Sankey uniquement.
CARACTÉRISTIQUES
1. Tour de bière
2. Joint en caoutchouc (peut ne pas être requis
dans toutes les configurations)
3. Garde-corps
4. Bac de récupération
5. Cadran du thermostat
6. Coupleur pour le fût
7. Fût de bière (non inclus)
8. Plaque de support en métal
9. Roulettes
10.Régulateur de CO2
11.Réservoir de CO2
12.Support de réservoir de CO2
INSTRUCTIONS D’INSTALLATION
EMPLACEMENT D’INSTALLATION
• Placez l’appareil sur un sol suffisamment solide
pour le supporter lorsqu’il est complètement
chargé.
• Ne placez pas l’appareil à la lumière directe
du soleil ou à proximité de sources de chaleur,
telles qu’une cuisinière ou un radiateur, car cela
peut augmenter la consommation électrique.
Des températures ambiantes froides extrêmes
peuvent également empêcher l’appareil de
fonctionner correctement.
• N’utilisez pas l’appareil près de l’eau, par
exemple dans un sous-sol humide ou près d’un
évier.
• Cet appareil est destiné à une utilisation en
intérieur uniquement. Il n’est pas conçu pour être
installé à l’extérieur, y compris dans les endroits
où la température n’est pas contrôlée (garages,
porches, véhicules, etc.).
• Avant de brancher l’appareil à une source
d’alimentation, laissez-le reposer pendant
environ 6 heures. Cela réduira la possibilité
d’un dysfonctionnement du système de
refroidissement lors de la manipulation pendant
le transport.
• Cet appareil est destiné uniquement à une
installation autonome et n’est pas conçu pour
être intégré dans une armoire ou un comptoir.
La construction de cet appareil peut entraîner un
dysfonctionnement.
19
1
2
34
5
7
8
9
10
11 12
6
Other manuals for DKC054A1BSL2DB
2
Table of contents
Languages:
Other Danby Accessories manuals

Danby
Danby Silhouette DKC646BLS User manual

Danby
Danby DKC054A9SLDB User manual

Danby
Danby DKC054A9SLDB User manual

Danby
Danby Designer Chill'n Tap DKC645BLS User manual

Danby
Danby DKC054A1BSL2DB User manual

Danby
Danby DKC5811BSL-2 Assembly instructions

Danby
Danby DKC054A1BSLDB User manual

Danby
Danby DKC052BSLDB-D Assembly instructions
Popular Accessories manuals by other brands

International Biomedical
International Biomedical AirBORNE A750i Service manual

IFM
IFM O2D51 Series operating instructions

TMT
TMT TI-5700 Operation manual

Greengate
Greengate OAC-DT-2000-MV installation instructions

Linn
Linn KUDOS SNEAKY installation instructions

Troy-Bilt
Troy-Bilt OEM-290-255 Operator's manual