Danby DKC054A9SLDB User manual

DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9
DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840
OWNER’S MANUAL
MANUEL DU PROPRIÉTAIRE
MANUAL DEL PROPIETARIO
www.Danby.com
*
*
MODEL • MODÈLE • MODELO
DKC054A9SLDB
KEG COOLER
Owner’s Manual.............................1 - 16
GLACIÈRE DE BIÈRE PRESSION
Manuel du propriétaire.................17 - 32
BARRIL REFRIGERADOR
Manual del propietario.................33 - 48
2021.03.08

1
2
3
4
1. Pressure gauge dial
2. Pressure relief ring
3. Open / Close valve
4. Tank strap
Ensure the CO2tank is empty before courier or 3rd party transport.
DANGER - A full or partially full CO2tank is under extreme pressure. Uncontrolled
release of pressure is extremely dangerous. The instructions below use the regulator to
control the release of this pressure in a safe manner. Do not bypass the regulator.
1. Ensure tank is secure
2. Fully open valve by turning counter-clockwise. Pressure gauge dial will show a
value if tank contains pressure.
3. Gently pull pressure relief ring. Released gas should be heard.
4. The pressure dial will read zero when the tank is empty. Continue to hold pressure
relief open until tank is empty.
5. Release the pressure relief ring.
6. Fully close valve by turning clock-wise.
1

3
SAFETY REQUIREMENTS
DANGER: Risk of fire or explosion. Flammable
refrigerant used. Do not puncture refrigerant tubing.
• Do not use mechanical devices to defrost
refrigerator.
• Ensure that servicing is done by factory
authorized service personnel, to minimize
product damage or safety issues.
• If the power supply cord is damaged, it must be
replaced by the manufacturer, its service agent
or similar qualified person in order to avoid
hazard.
• Consult repair manual or owner’s guide before
attempting to service this product. All safety
precautions must be followed.
• Dispose of properly in accordance with federal
or local regulations.
• Follow handling instructions carefully.
• Do not store explosive substances such as
aerosol cans with a flammable propellant in this
appliance.
WARNING: Keep ventilation openings, in the
appliance enclosure or in the built-in structure, clear
of obstruction.
WARNING: Do not use mechanical devices or other
means to accelerate the defrosting process, other
than those recommended by the manufacturer.
WARNING: Do not damage the refrigerant circuit.
WARNING: Do not use electrical appliances inside
the food storage compartments of the appliance,
unless they are of the type recommended by the
manufacturer.
CAUTION: Children should be supervised to ensure
that they do not play with the appliance.
DANGER: Risk of child entrapment. Before throwing
away an old appliance:
• Remove the door or lid.
• Leave shelves in place so that children may not
easily climb inside.
DANGER: Do not add a lock to the door or lid. This
can cause child entrapment and harm.
SAFETY REQUIREMENTS
This appliance is not intended for use by persons
(including children) whose physical, sensory or
mental capabilities may be different or reduced,
or who lack experience or knowledge, unless such
persons receive supervision or training to operate
the appliance by a person responsible for their
safety.
This appliance is intended to be used in household
and similar applications such as:
• Staff kitchen areas in shops, offices and other
working environments;
• Farm houses and by clients in hotels, motels and
other residential type environments;
• Bed and breakfast type environments;
• Catering and similar non-retail applications.
GROUNDING INSTRUCTIONS
This appliance must be grounded. Grounding
reduces the risk of electrical shock by providing an
escape wire for the electrical current.
This appliance has a cord that has a grounding
wire with a 3-prong plug. The power cord must be
plugged into an outlet that is properly grounded.
If the outlet is a 2-prong wall outlet, it must be
replaced with a properly grounded 3-prong wall
outlet. The serial rating plate indicates the voltage
and frequency the appliance is designed for.
WARNING - Improper use of the grounding
plug can result in a risk of electric shock.
Consult a qualified electrician or service agent
if the grounding instructions are not completely
understood, or if doubt exists as to whether the
appliance is properly grounded.
Do not connect your appliance to extension
cords or together with another appliance in the
same wall outlet. Do not splice the power cord.
Do not under any circumstances cut or remove the
third ground prong from the power cord. Do not
use extension cords or ungrounded (two prongs)
adapters.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!

WARNING: CO2CAN BE DANGEROUS!
CO2Cylinders, when charged, contain high
pressure compressed gas which can be hazardous
if not handled properly. Read and understand the
following procedures for CO2cylinders before
installation:
1. Always check the D.O.T. (Department of
Transportation) as well as the T.C. (Transport
Canada) test date located on the neck of the
cylinder before installation. If the date is older
than five (5) years, do not use! Return the gas
cylinder to a gas supplier for re-certification
(service charges may be applicable).
2. Always connect a CO2gas cylinder to a
regulator. Failure to do so could result in an
explosion which can possibly result in death or
injury when the cylinder valve is opened.
3. Always follow correct procedures when cylinders
are changed as per local codes.
4. Always secure a CO2 gas cylinder in an
“upright” position.
5. Always keep a CO2gas cylinder away from
heat. Store extra cylinders in a cool place
(preferably 70°F/21°C). Securely fasten with a
chain in an upright position when storing.
6. Always ventilate and leave the area immediately
after any leakage of CO2.
7. Never connect a CO2gas cylinder directly to a
beer keg.
8. Never drop or throw a CO2cylinder.
9. Never connect a keg without at least one
safety pressure release. There are two safety
mechanisms in the pressure system;
• One at or on the CO2regulator.
• One at or on the product container coupler
in the pressure gas line.
Note: The regulator and keg coupler supplied
with this appliance are inclusive of such safety
mechanisms.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
WARNING: CO2CAN BE DANGEROUS!
If it becomes difficult to breathe and/or your head
starts to ache, abnormal concentrations of carbon
dioxide (CO2) may be present in the area.
CLOSE THE MAIN VALVE ON THE CO2CYLINDER,
VENTILATE AND LEAVE THE ROOM IMMEDIATELY!
Beer is easily available with Danby’s Keg Cooler,
however, it is not intended to be available to people
under the legal age to consume beer. Danby
does not assume liability for the unlawful use or
consumption of the beer.
PLEASE DRINK RESPONSIBLY AND PLEASE DON’T
DRINK AND DRIVE!
WARNING
CO2GAS CAN BE DANGEROUS
CO2cylinders contain high-pressure compressed
gas which can be hazardous if not handled
properly. Make sure to read and understand
all safety procedures for CO2cylinders before
installation.
4

BEFORE USING YOUR KEG COOLER
• Remove the exterior and interior packaging.
• Check to be sure you have all the following
parts:
• 2 guard rails
• 1 drip tray (2 pieces)
• 1 CO2tank support
• 1 CO2regulator
• 1 CO2tank (empty)
• 1 CO2gas line hose (coloured)
• 1 beer hose
• 1 beer keg coupler
• 1 beer tower
• 1 faucet handle
• 1 metal plate for cabinet bottom
• 2 wire shelves
• 1 steel clamp for coloured hose
• 2 plastic washers for front casters
• 4 casters (2 front with locks)
Note: This appliance includes an American Sankey
tap coupler only.
Note: This keg cooler accepts domestic kegs up to
16-1/8” in diameter and up to 23-3/8” in height.
Check with the distributor to make sure the keg is
correct size.
FEATURES
1. Beer Tower
2. Rubber Gasket (may not be required in all
configurations)
3. Guard Rail
4. Drip Tray
5. Thermostat dial
6. Keg Coupler
7. Beer Keg (not included)
8. Metal Support Plate
9. Casters
10.CO2 Regulator
11.CO2 Tank
12.CO2 Tank Support
10
11
9
8
7
6
5
4
3
1
2
12
INSTALLATION INSTRUCTIONS
INSTALLATION LOCATION
• Place the appliance on a floor that is strong
enough to support it when it is fully loaded.
• Do not place the appliance in direct sunlight or
near sources of heat, such as a stove or heater,
as this can increase electrical consumption.
Extreme cold ambient temperatures may also
cause the appliance to perform improperly.
• Do not use the appliance near water, for
example in a wet basement or near a sink.
• This appliance is intended for indoor use only. It
is not designed for outside installation, including
anywhere that is not temperature controlled
(garages, porches, vehicles, etc.).
• Before connecting the appliance to a power
source, let it stand upright for approximately
6 hours. This will reduce the possibility of a
malfunction in the cooling system from handling
during transportation.
• This appliance is intended for free-standing
installation only and is not intended to be
built into a cabinet or counter. Building in this
appliance can cause it to malfunction.
5

INSTALLATION DIAGRAM
1. CO2 regulator
2. CO2 gas tank
3. Coloured CO2hose
4. Faucet assembly
5. Tower
6. Clear hose
7. Coupler
8. Keg
INSTALLATION INSTRUCTIONS
1
2
3
8
7
6
4
5
CASTER INSTALLATION INSTRUCTIONS
Install the four casters. The two locking casters
should be placed at the front. Four screw holes have
been pre-drilled into the bottom of the cabinet at
each corner for each caster. Put the plastic washers
provided on the front casters before installing them.
CASTOR BRAKES
The two front casters are supplied with brakes to ensure the appliance does not move excessively while
being used. It is recommended to engage the brakes while the appliance is in use to avoid damage to the
appliance, the contents or personal property.
Step on to brake Step on to
release brake
6

INSTALLATION OF CO2 TANK SUPPORT
Install the metal support onto the four studs located
on the exterior back wall of the cabinet.
Align the holes in the support with the studs and
push down firmly.
INSTALLATION OF CO2 TANK AND CO2REGULATOR
The CO2tank does not come filled. The tank must be
filled with CO2before use.
Place the charged tank into the support stand.
Attach the CO2regulator to the tank by turning
the regulator nut onto the tank valve, making sure
the washer is securely inserted into the connecting
nut. Tighten snug using an adjustable wrench (not
supplied) and ensure there are no leaks, i.e. no
hissing sounds when the CO2is turned on.
INSTALLATION OF CO2 AIR LINE AND CONNECTION TO CO2REGULATOR
Remove the plug located at the exterior back of
the cabinet, in the top left hand corner. Save the
plug for later use to convert the appliance to a
refrigerator.
Feed the gas line through the cabinet and out
through the uncovered hole.
Attach the open end of the hose to the hose barb
connection on the regulator. Secure the hose
by using one clamp provided. Use pliers or a
screwdriver to tighten the clamp to prevent leaks.
INSTALLATION INSTRUCTIONS
7

INSTALLATION OF THE BEER TOWER
• Remove the plug from the top of the fridge
cabinet by twisting and pulling out. Save the
plug for later use to convert the appliance to a
refrigerator.
• Unravel the beer line (clear hose) from the tower
and insert the beer line and wing nut through
the uncovered hole on top of the cabinet.
• Secure the beer tower assembly to the top of the
cabinet by pressing down and turning the tower
to lock in place. Ensure the faucet is aligned with
the front of the appliance.
• The rubber gasket can be used to make the
connection between the tower and the cooler
tighter if needed. If the beer tower will not turn
to lock in place, try removing the rubber gasket.
The rubber gasket may not be required in all
configurations.
Note: If the faucet is leaking or if the beer is very
foamy, ensure that the washers inside the faucet are
intact. Replace the washers with spare parts from
the accessory bag, if necessary.
1. Handle washer
2. Tap washer
3. Spout washer
INSTALLATION INSTRUCTIONS
FAUCET WRENCH
The provided faucet wrench is for either removing or tightening the faucet connection. If the beer is not
flowing freely, use the wrench to remove the faucet for cleaning. If the faucet connection is leaking, use the
wrench to tighten the faucet connection.
PLASTIC FAUCET HANDLE
Attach the black plastic handle to the top of the faucet. Hold the silver nut underneath so it does not turn.
If there is a small drip from the faucet, the silver nut may be overtightened. Unscrew silver nut counter-
clockwise by one turn.
INSTALLATION OF THE PROTECTIVE METAL PLATE
The protective metal plate should be installed on the bottom of the inside of the cabinet. This plate should
always be installed when a keg is in place to protect the floor of the cabinet from damage.
INSTALLATION OF THE BEER KEG
• Two people should lift the keg to avoid back injury
• Position the keg directly in front of the open door.
• Using the keg handles, lift the front of the keg just enough so the front end is resting on the front edge
of the keg cooler bottom cabinet.
• Grasp the keg handles and slide it all the way into the cabinet.
8

INSTALLATION OF THE KEG COUPLER
Insert the keg coupler into the locking neck of the
beer keg and turn it clockwise to lock into position,
making sure the keg coupler handle is in the closed
position, with the handle up.
1. Coupler pressure release valve
2. Handle in closed position
INSTALLATION OF THE CO2AIR LINE HOSE
Attach the end of the coloured air line hose to the hose connection on the side of the coupler. Ensure that
the reed valve is inserted into the connection, number 4 on the image below.
If, after assembly, beer will not flow, ensure that the reed valve has a small hole in it. If there is no hole in
the reed valve then CO2cannot enter the line and the beer will not flow.
1. Valve washer
2. Check valve
3. O-type washer
4. Reed valve
5. Valve washer
6. Valve washer
CONNECTING THE BEER TOWER TO THE COUPLER
• Ensure all washers are properly inserted into the coupler,
as per the below image.
• Ensure the check valve is in place inside the coupler,
number 2 on the below image.
• Place the wing nut attached to the end of the beer line
into the top of the coupler, turning until tight.
If, after assembly, the beer is very foamy, it most likely means
that a connection in the coupler is leaking and air is entering
the lines. Double check all connections in the coupler and
replace the washers from the accessory bag as necessary.
INSTALLATION INSTRUCTIONS
1
2
9

HOW TO TAP A KEG OF BEER
• Make sure the CO2is turned off and the valve
on the regulator is in the closed position.
• Pull out and release the pressure release valve
on the coupler to purge any air pressure.
• Make sure the faucet handle is in the closed
position.
• Pull the coupler handle out and downward until
it locks into its open position. The teeth on the
underside of the coupler will bite into the locking
neck of the beer keg.
Note: If a keg is very tall, it may be necessary to
connect the coupler to the keg before inserting the
keg into the keg cooler.
OPENING THE CO2TANK MAIN VALVE
• Make sure the secondary shut-off valve (shown below in “open” position) is closed. To open the main
CO2cylinder valve, slowly turn the main valve counter-clockwise until fully open.
• Notice the needle on the regulator gauge start to climb.
ADJUSTING THE CO2REGULATOR
The gauge monitors internal keg pressure and should be
adjusted to read between 8-12 PSI. The pressure can be
adjusted as needed. After making any adjustment to the PSI,
wait 5 - 10 minutes before attempting to pour another beer
to allow the pressure to equalize.
• If the beer is very foamy, try turning the pressure down.
• If the flow of beer is very weak, try turning the pressure
up.
1. Loosen the lock nut.
2. Turn the adjustment screw with a flat screwdriver.
• To increase pressure, turn screw clockwise.
• To decrease pressure, turn screw counter-clockwise.
3. Allow several minutes for the keg to properly pressurize
before adjusting the pressure further. The regulator
gauge may drop while this happens.
4. Retighten the lock nut to ensure the pressure does not get
adjusted accidentally.
Note: Listen for hissing along all connections to identify if
there are any leaks.
OPERATING INSTRUCTIONS
12
1. Coupler pressure release valve
2. Handle in open position
1
2
3
4
1. Connection to C02tank
2. Shut off valve (open position)
3. Lock nut
4. Adjustment screw
10

DISPENSING OF BEER
• Keep beer keg refrigerated at all times.
• Never allow beer lines to dry out.
• Use clean glassware before pouring.
• Hold glass at a 45° angle, when it is 2/3 full,
start to straighten glass as the glass fills.
• Always make sure the faucet handle is pushed
all the way back.
Note: The refrigerator compartment cannot
accommodate the “Coors” style beveled barrel keg.
Note: Our keg cooler accepts domestic kegs up to
16-1/8” in diameter and up to 23-3/8” in height.
Check with your distributor to make sure keg is
correct size.
Note: It is important to allow the keg to sit upright
and undisturbed, for 2 hours before tapping.
SETTING THE TEMPERATURE
The temperature is controlled by adjusting the
thermostat control knob.
• The thinnest part of the dial is the warmest
setting.
• The thickest part of the dial is the coldest setting.
• To turn off the cooling, rotate the control knob to
the “0” (OFF) position.
AUTOMATIC DEFROSTING
There is no need to defrost the keg cooler. Defrost
water collects and passes through the drain outlet
in the rear wall into a tray located above the
compressor, where it evaporates.
Note: If the appliance is unplugged, power lost or
turned off, wait 3 to 5 minutes before restarting the
appliance. If there is an attempt to restart before this
time delay, the compressor may not start.
CONVERTING TO A REFRIGERATOR
1. Turn the thermostat dial to the “OFF” position.
2. Close the main valve on the CO2cylinder.
3. Close the secondary shut-off valve on the
regulator pipe.
4. Close the connection between the beer keg and
the keg coupler.
5. Drain any remaining beer from the lines. (We
recommend cleaning at this point, please see
Care and Maintenance section).
6. Disconnect the beer line and CO2gas line from
the keg coupler.
7. Remove the beer keg.
8. Remove the keg coupler.
9. Disconnect the gas line from the CO2cylinder.
10.Remove the CO2gas line from cabinet plug.
11.Replace the gas line rear cabinet plug.
12.Remove the beer tower. Also pull the beer line
through the top of the cabinet.
13.Replace the top cabinet plug.
14.Adjust the temperature as desired.
Note: In order to convert the appliance, the gas line
must be disconnected from the regulator in order to
remove it from the cabinet.
Note: Install the shelf by sliding it into the desired
spot in the appliance.
OPERATING INSTRUCTIONS
11

OPERATING INSTRUCTIONS
12
DOOR REVERSAL INSTRUCTIONS
If the appliance is placed on its back or side for any length of time
during this process, it must be allowed to remain upright for 6 hours
before plugging it in to avoid damage to the internal components.
1. Remove the two screws from the back of the worktop. Lift the back
of the worktop and pull it toward the front of the appliance to
remove it. Remove the worktop hinge hole cover from the left side
of the worktop and move it to the hinge hole on the right side of
the worktop.
2. Remove the door spindle cover that covers the hinge on the top
left side of the door. Remove the hole cover from the top right side
of the door. Removing the hole cover may require a flat blade
screwdriver.
3. Remove the upper hinge from the top right side of the cabinet.
Remove the door from the cabinet.
4. Remove the lower hinge hole cover from the bottom left side of the
door and move it to the bottom right side of the door.
5. Remove the lower hinge from the bottom of the cabinet and
remove the hinge pin from the lower hinge. Flip the lower hinge
over and install the hinge pin on the other side.
6. Remove the adjustable foot from the bottom right side of the
cabinet. Remove the solid foot and screws from the bottom left
side of the cabinet. Install the solid foot on the bottom right side of
the cabinet. Install the lower hinge and the adjustable foot on the
bottom left side of the cabinet.
7. Remove the hinge pin from the upper hinge. Flip the upper hinge
over and install the hinge pin on the other side.
8. Install the upper hinge and door onto the cabinet.
9. Install the door spindle cover to cover the hinge on the top right
side of the door. Install the hole cover in the hole on the top left
side of the door.
10.Install the worktop by laying it on top of the appliance and
pushing it toward the back until it clicks into place and then
reinstall the two screws at the back.
Note: When reinstalling the door, ensure that the top of the door is
level with the top of the cabinet and that the rubber gasket makes a
good seal with the cabinet all the way around.
1
2
3
4
5
6
7
8
9
10

CLEANING THE KEG COOLER
• Turn the temperature control to “OFF”, unplug
the keg cooler, and remove the contents.
• Wash the inside surfaces with a warm water and
baking soda solution. The solution should be 2
tablespoons of baking soda to a quart of water.
• Wash the shelves and stand with a mild
detergent solution.
• Wipe down any electrical controls with a dry
cloth.
• Wash the outside cabinet with warm water and
mild liquid detergent. Rinse well and wipe dry
with a clean soft cloth.
CARE & MAINTENANCE
CLEANING THE BEER LINES
Beer lines have to periodically be cleaned because
of a crystallized sugar build up which forms on
the fittings, lines and taps. If the build up is not
completely removed in a cleaning process it will
leave an unsanitary surface that can harbor
microorganisms which will cause an undesirable
flavour and/or cause the beer to go flat. Sufficient
build up will also lead to dispensing problems
ranging from foamy beer to flat beer, regardless of
the carbonation levels or the quality or age of the
beer in the keg.
Scheduled line and faucet cleaning eliminates the
build-up, protecting the integrity of the product and
condition of the dispensing system and seals. The
beer line should be cleaned and rinsed with hot
water approximately once every three weeks or
every other keg - which ever comes first. The faucet
should be cleaned with hot water on a weekly basis
or prior to every use if not used on a regular basis.
Note: If the faucet handle becomes stuck or hard
to move, this is usually indicative that it requires
cleaning. DO NOT apply force to move the handle
in this situation, as this can lead to damaging the
handle or faucet and will not be covered by the
warranty.
13

14
FREQUENTLY ASKED QUESTIONS
What are the standard wattage and amps used?
Information pertaining to watts and amps can be found on the rating plate located on the back of the unit.
Tips before trying a pour
• Has the CO2tank be filled and is the recommended pressure set
• Allow the keg to settle and cool (think of the unsettled keg as a shaken soda can)
• Wetting glass before pour reduces surface tension with less foam in glass.
No beer coming out of tap when it’s opened for a pour
• Make sure the CO2tank has been filled and is set at the recommended pressure
• Make sure the CO2tank is open all the way
• Make sure the beer keg is a North American beer keg
• Make sure the regulator is fastened on tank properly ( check for gas before hose hook-up)
• Make sure the cock valve on the regulator is pointing down the hose and not across the hose (Open
position arm pointing down)
• Ensure the tap on the coupler is pushed down and locked in the open position
• Remove cap on top of the tower and make sure the beer line is not kinked
A very slow pour
• Kinked beer line
• Low or no pressure in the CO2tank (pressure set at the recommended pressure)
• No beer in the keg
• Handle on coupler not down all the way and locked in the open position
A very large amount of foam on top of the beer
• The pressure is not set properly (an adjustment may have to be made)
• The beer in the keg is still unsettled allow to settle and cool before a pour
• Check to make sure the ball float (inside the coupler) is free to move
• NOTE: If any adjustment is made let the pressure settle before a pour
Beer leaking from a connection
• Make sure there are washers where there is a metal to metal connection
• Make sure the washers or “o” rings are not damaged and in the proper place
• Make sure there are no impurities on any of the washers or “o” rings; “o” rings in the tap washers are
in the hose and coupler connections
Handle won’t move.
If beer in the tap was not cleaned out before the unit sat idle for an extended period of time the sugars in
the beer may have hardened and caused the beer tap lever to stick. Remove the tap from the tower and
soak it in hot water for 30 minutes. This will soften and dissolve the hardened sugars inside the tap and
allow movement. Rinse the tap throughly before replacing on the tower.

TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE
The unit does not operate • Not plugged in
• The circuit breaker tripped or blown fuse
Turns on and off
frequently • The room temperature is hotter than normal
• The door is open too often
• The door is not closed completely
• The temperature control is not set correctly
• The door gasket does not seal properly
• The unit does not have proper clearance
Vibrations • Check that the keg cooler is level
The keg cooler seems to
make too much noise • The rattling noise may come from the flow of refrigerant, which is normal
• Gurgling, caused by liquid refrigerant cycling is normal
• Contraction and expansion of the inside walls may cause popping and
crackling noises
• The keg cooler is not level
The door will not close
properly • The keg cooler is not level
• The door was reversed and not properly reinstalled
• The gasket is dirty
• The shelves or stand are out of position
• The keg is not properly centered in the unit
• The casters are not attached
Excessive beer foam • Ensure the beer line hose from the tower and the CO2air line hose from
the CO2regulator are attached to the correct connections on the coupler;
beer line to the top of the coupler, CO2air line to the side of the coupler
• Check that there are no leaks in any connections
• Ensure that the reed valve in the CO2connection at the coupler has a
hole in it
• The CO2pressure may be set too high; try turning the pressure down
• Ensure that the check valve is inserted into the coupler
• Ensure the beer lines are clean
Weak beer flow • Ensure the beer line hose from the tower and the CO2air line hose from
the CO2regulator are attached to the correct connections on the coupler;
beer line to the top of the coupler, CO2air line to the side of the coupler
• Check that there are no leaks in any connections
• Ensure that the reed valve in the CO2connection at the coupler has a
hole in it
• The CO2pressure may be set too low; try turning the pressure up
• Ensure there are no bends or kinks in any of the hoses that could impede
fl o w
• Ensure the beer lines are clean
15
Other manuals for DKC054A9SLDB
1
Table of contents
Other Danby Accessories manuals

Danby
Danby DKC054A1BSLDB User manual

Danby
Danby DKC054A9SLDB User manual

Danby
Danby Silhouette DKC646BLS User manual

Danby
Danby DKC054A1BSL2DB User manual

Danby
Danby DKC054A1BSL2DB User manual

Danby
Danby DKC052BSLDB-D Assembly instructions

Danby
Danby Designer Chill'n Tap DKC645BLS User manual

Danby
Danby DKC5811BSL-2 Assembly instructions
Popular Accessories manuals by other brands

Keysight Technologies
Keysight Technologies N6841A user guide

weinor
weinor Cassita Assembly instructions

Interlevin
Interlevin PD10H instruction manual

KUNDALINI
KUNDALINI SHAKTI Assembly instructions

Dometic
Dometic POWER AWNING PRO Installation and operation manual

EZ CONNECT
EZ CONNECT EZ Button Getting started