PM,N Nominal motor power
PCB Printed circuit board
PELV Protective extra low voltage
Regen Regenerative terminals
RPM Revolutions per minute
s Second
TLIM Torque limit
UM,N Nominal motor voltage
V Volts
Table 1.2 Abbreviations
1.5 Additional Resources
•VLT
®
HVAC Basic Drive FC 101 Quick Guide provides
basic information on mechanical dimensions,
installation, and programming.
•VLT
®
HVAC Basic Drive FC 101 Programming Guide
provides information on how to program, and
includes complete parameter descriptions.
•Danfoss VLT®Energy Box software. Select PC
Software Download at www.danfoss.com/Busines-
sAreas/DrivesSolutions.
VLT®Energy Box software allows energy
consumption comparisons of HVAC fans and
pumps driven by Danfoss frequency converters
and alternative methods of ow control. Use this
tool to accurately project the costs, savings, and
payback of using Danfoss frequency converters
on HVAC fans, pumps, and cooling towers.
Danfoss technical literature is available in electronic form
on the documentation CD that is shipped with the
product, or in print from your local Danfoss sales oce.
MCT 10 Set-up Software support
Download the software from www.danfoss.com/Busines-
sAreas/DrivesSolutions/Software+MCT10/
MCT10+Downloads.htm.
During the installation process of the software, enter
access code 81463800 to activate FC 101 functionality. A
licence key is not required for using FC 101 functionality.
The latest software does not always contain the latest
updates for frequency converters. Contact the local sales
oce for the latest frequency converter updates (in the
form of *.upd les), or download the frequency converter
updates from www.danfoss.com/BusinessAreas/DrivesSo-
lutions/fc101driveupdates.
1.6 Denitions
Frequency converter
IVLT, MAX
The maximum output current.
IVLT,N
The rated output current supplied by the frequency
converter.
UVLT, MAX
The maximum output voltage.
Input
The connected motor can start and stop via LCP and
digital inputs. Functions are divided into 2 groups, as
described in Table 1.3. Functions in group 1 have higher
priority than functions in group 2.
Group 1 Reset, coast stop, reset and coast stop, quick
stop, DC brake, stop, and [O].
Group 2 Start, pulse start, reversing, start reversing, jog,
and freeze output.
Table 1.3 Control Commands
Motor
fJOG
The motor frequency when the jog function is activated
(via digital terminals).
fM
The motor frequency.
fMAX
The maximum motor frequency.
fMIN
The minimum motor frequency.
fM,N
The rated motor frequency (nameplate data).
IM
The motor current.
IM,N
The rated motor current (nameplate data).
nM,N
The nominal motor speed (nameplate data).
PM,N
The rated motor power (nameplate data).
UM
The instantaneous motor voltage.
UM,N
The rated motor voltage (nameplate data).
Introduction Design Guide
MG18C702 Danfoss A/S © 04/2016 All rights reserved. 7
11