Air lter dirty. Remove, clean and reinstall.
customer service. Have diaphragm replaced by a qualied service
A small air lter is located on the underside of the pump. This should be
removed, rinsed, dried and reinstalled periodically.
AIRPUMPS
CARE AND OPERATING INSTRUCTIONS FOR
MODEL
AP-2
AP-3
AP-4
AP-8
Watts
1.5
2.8
3.5
7
Air Flow
cu. in/min
73
110
275
549
Pressure
psi
1.45
1.45
2.0
2.0
Max Water
depth
3’
3.3’
4’
4.5’
E.G. Danner Manufacturing, Inc. will repair or replace any air pump
found to be defective within one year of original purchase by original
owner from an accredited dealer. Air lter, apper valves, and
diaphragms are wearable items and are not covered by this warranty.
Cutting or altering the cord voids any warranty consideration. For
warranty repair, return only the part that is defective to our factory.
Please include a dated proof of purchase and $5.00 for postage and
handling. Damages or injuries resulting from negligence or misuse of
the product are not covered by this warranty. This warranty gives you
specic legal rights. You may have other rights which may vary from
state to state. To validate this warranty keep your proof of purchase
(Copy of sales receipt from an accredited dealer).
DANNER MFG. INC. •160 Oval Drive, Islandia, NY 11749
(631) 234-5261 •Visit our web site at www.dannermfg.com
LIMITED ONE-YEAR WARRANTY
MAINTENANCE & TROUBLESHOOTING
If pump volume decreases or stops, check the following:

Airline tube may be kinked. Straighten out tube or install new
tubing if necessary.

Airstone clogged. Replace air stone.


Plug is not secure in receptacle. Check all electrical connections.

Internal diaphragm is worn. Replacement diaphragm kit Item #
14605 is available for models AP-4 and AP-8; please call Danner
technician. Note that the 14605 repair kit provides parts to repair two
outlets. Use one kit to repair the AP-4 and two kits to repair the AP-8.
The AP-Series air pumps have been designed to satisfy the requirements
of a multitude of water related applications. These beautifully designed,
environmentally friendly pumps can be used for:
Aerating Single or Multiple Aquarium Tanks
Oxygenating Hydroponic Nutrients
Oxygenating Indoor Ponds and Water Gardens
Aerating Single or Multiple Terrarium Tanks
Oxygenating Indoor Water Features
All AP-Series air pumps operate on standard 110V electric and come with
6’ power cords. They have been designed to operate efficiently with a
motor that is non-oil lubricated.
Models Item #’s
AP-2 40512 06402
AP-3 40513 06403
AP-4 40514 06404
AP-8 40518 06408
ZG144 3/11
14
AIR PUMP
POWER
SUPPLY
CORD
WATER
TANK
DRIP
LOOP
Pump on tank
No Drip Loop
Pump
mounted
Pump
on shelf
Drip Loop
Drip Loop
IMPORTANT SAFETY INSTRUCTIONS
A) READ AND FOLLOW ALL SAFETY INSTRUCTIONS
WARNING WARNING -
WARNING -
PUMP INSTALLATION AND OPERATION
DANGER -
To guard against injury, basic safety precautions
should be observed, including the following:
A). FOR INDOOR AND HOUSEHOLD USE ONLY.
B). TO PREVENT POSSIBLE ELECTRIC SHOCK RESULTING FROM WATER BACK
SIPHONING, PUMP SHOULD BE LOCATED HIGHER THAN WATER LEVEL.
To avoid possible electric shock, special care should be taken since water is employed in the
use of aquarium and pond equipment. For each of the following situations, do not attempt
repairs by yourself; return the appliance to an authorized service facility for service or discard
the appliance.
I. If the appliance falls into the water, DON’T reach for it! First unplug it and then retrieve it. If
electrical components of the appliance get wet, unplug the appliance immediately.
II. Carefully examine the appliance after installation. It should not be plugged in if there is
water on parts not intended to be wet.
III. Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or
has been dropped or damaged in any manner.
IV. To avoid the possibility of the appliance plug or
receptacle getting wet, position the aquarium stand and
tank to one side of a wall-mounted receptacle to prevent
water from dripping onto the receptacle or plug. A
“drip loop” shown in the gure below, should be
arranged by the user for each cord connecting an
aquarium appliance to a receptacle. The “drip loop” is
that part of the cord below the level of the receptacle, or the connector if an extension
cord is used, to prevent water from traveling along the cord and coming in contact with the
receptacle. If the plug or receptacle does get wet, DON’T unplug the cord. Disconnect the
fuse or circuit breaker that supplies power to the appliance. Then, unplug and examine for
the presence of water in the receptacle.

Please read this operating instruction manual thoroughly and keep it for reference.

The pump is not designed to work submerged, so do not place the pump into water.

Always securely position the pump higher than water level. This will prevent water from
entering the pump housing through the air hose if power is interrupted.

Avoid sharp turns that can cause kinks in airline tubing as it may cause excessive back
pressure and decrease air flow.

The AP-4 and AP-8 are supplied with variable output control knob on the top of the
pump. The air output can be regulated by turning the control knob.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning the use of the of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
INCORRECT
CORRECT
CORRECT
32
B). Close supervision is necessary when an appliance is used by or near children.
C). To avoid injury, do not contact moving parts or hot parts such as heater, reectors, lamp
bulbs and the like.
D). Always unplug an applicance from an outlet when not in use. before putting on or taking o
parts, and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug and
pull to disconnect.
E). Do not use an appliance for other than intended use. The use of attachments not
recommended or sold by the appliance manufacturer may cause an unsafe condition.
F). Do not install or store the appliance where it will be exposed to the weather or
to temperature below freezing.
G). Make sure any appliance mounted on a tank is securely installed before operating it.
H). Read and observe all important notices on the appliance.
I). If an extension cord is necessary, a cord with a proper rating should be used. A cord rated
for less amperes or watts than the appliance rating may overheat. Care should be taken to
arrange the cord so that it will not be tripped over or pulled.
J). This appliance has a polarized plug (One blade is larger than the other). As a safety feature,
this plug will t in a polarized outlet only one way, If the plug does not t fully in the outlet,
reverse the plug. If it still does not t, contact a qualied electrician. Never use with an
extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature.
K). This appliance has no user serviceable parts.
L). SAVE THESE INSTRUCTIONS

This manual suits for next models

11

Other Danner Water Pump manuals

Danner Pondmaster 9.5 User manual

Danner

Danner Pondmaster 9.5 User manual

Danner 02519 User manual

Danner

Danner 02519 User manual

Danner 20370 User manual

Danner

Danner 20370 User manual

Danner 20370 User manual

Danner

Danner 20370 User manual

Danner SP-155 User manual

Danner

Danner SP-155 User manual

Danner 02740 User manual

Danner

Danner 02740 User manual

Popular Water Pump manuals by other brands

Aquatech Pressmain Aquamatic AMV Series instructions

Aquatech Pressmain

Aquatech Pressmain Aquamatic AMV Series instructions

Doheny's 90500 Installation, operation & parts

Doheny's

Doheny's 90500 Installation, operation & parts

salmson MULTI-H Series Installation and starting instructions

salmson

salmson MULTI-H Series Installation and starting instructions

vacuubrand MZ 2 VARIO-SP Instructions for use

vacuubrand

vacuubrand MZ 2 VARIO-SP Instructions for use

Zuwa UNISTAR 2001-A operating instructions

Zuwa

Zuwa UNISTAR 2001-A operating instructions

DAISHIN PTD Series manual

DAISHIN

DAISHIN PTD Series manual

Gardner Denver Elmo Rietschle V-KTR 100 operating instructions

Gardner Denver

Gardner Denver Elmo Rietschle V-KTR 100 operating instructions

Lincoln J Series Owner's/operator's manual

Lincoln

Lincoln J Series Owner's/operator's manual

KIRLOSKAR CPHM Instruction on installation, operation and maintenance

KIRLOSKAR

KIRLOSKAR CPHM Instruction on installation, operation and maintenance

umbra pompe ACUAFLUSS 4 Addendum

umbra pompe

umbra pompe ACUAFLUSS 4 Addendum

Aqua HC 100 Operating and maintenance instructions

Aqua

Aqua HC 100 Operating and maintenance instructions

Casella Apex2 Field guide

Casella

Casella Apex2 Field guide

ARO PF20R-X-B Operator's manual

ARO

ARO PF20R-X-B Operator's manual

Elmo Rietschle V-VGD 10 operating instructions

Elmo Rietschle

Elmo Rietschle V-VGD 10 operating instructions

SPX PE8 Series operating instructions

SPX

SPX PE8 Series operating instructions

Grundfos Hydro 2000 F Installation and operating instructions

Grundfos

Grundfos Hydro 2000 F Installation and operating instructions

SFA SaniCondens Eco installation instructions

SFA

SFA SaniCondens Eco installation instructions

Sealey TP96 instructions

Sealey

Sealey TP96 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.