Hardware Installation
Please note that daisy-chaining capability is limited to two
MULTINETswitches
™
, thereby providing access to as many
as 32 segments using two MULTINETswitches™. The expla-
nation below will focus on the dual DSS Server installation
configuration to multiple W2358DSL WANswitches
™
shown
in Figure C2. To make interconnection between multiple
WAN switches
™,
two DSS/SIS’s, and individual network
links, follow the steps below:
Step 1: (
NOTE
:If a WA N switch™is to be used in a mixed
switch daisy-chain, it must be the first switch.) Install each
switch in the order that corresponds to it’s respective switch
address as assigned in the switch addressing program.
Connect the WAN MONITOR port of the dual DSS Server to
the
WAN Common Port
of the first MULTINETswitch™using a
DRL312-3 cable. Connect the LAN MONITOR port of the
dual DSS Server to the
LAN Common Port
of the first
MULTINETswitch™using a DRL366-3 cable. Then connect
the
WAN Link 8
and
LAN Segment 8
ports of the first
MULTINETswitch™to the
WAN Common Port
and
LAN
Common Port
of the second MULTINETswitch™using
DRL312-3 and DRL366-3, respectively.
Step 2: Connect the COM1 ports of the dual DSS Server to
the
Control
port of the first MULTINETswitch™using a
DRL293A-3 Control Cable . Then connect the
Link
port of
the first MULTINETswitch™to the
Control
port of the second
MULTINETswitch™using a DRL293A-3 cable.
Step 3: Connect network cables to the desired Link and
Segment ports of each MULTINETswitch™.
Step 4: Connect the Power Supply 5-pin DIN Male connec-
tor into the
Power
port of the MULTINETswitch™and then
plug the Power Supply into the external power source wall
receptacle. A green light within the center of the Datacom
front panel logo indicates power is on.
After the daisy-chain hardware installation is complete, the
API software must be configured or reconfigured. If this
installation is for a new daisy-chain, refer to the full ‘API
Software’ Appendix section beginning on Page D1 of this
USERguide. If you are adding or changing one or more
MULTINETswitches™to your configuration, reconfigure by
referring to Step 9 through Step 11 of the ‘API Software —
API Software Installation’ section on Page D5 of this
Appendix.
After the daisy-chain hardware installation is complete, the
switch control software must be configured or reconfigured.
Refer to the DATACOMswitch SOFTWAREguide.
C3
DDAAIISSYY--CCHHAAIINN