Datalogic ID-NET QL Series User manual

QL300 / QL500
Quick Link ID-NET™ Connectors
DESCRIPTION
The QL series ID-NET™ connectors provide a fast and efficient way to
cable an ID-NET™ network using standard cables. The QL300/500s are
typically Master ID-NET™ connectors designed to be used with the
QL100/150/200s ID-NET™ Slave connectors.
The QL300 is a passive connection module which can be used in
Standalone or ID-NET™ Master Multidata, Slave Multidata or Master
Synchronized layouts. It provides separate ports for Power Supply,
External Trigger, Digital I/O and Communication. Host communication is
provided through connectivity to the reader Main serial interface
(RS232/485) or Aux RS232 serial interface.
ID-NET™ network and power supply signals are sent out to the next
connected device by means of a dedicated port, however input power is
not received from the network. Therefore each QL300 must be powered
separately.
The QL500 is an active connection module which can be used in
Standalone or ID-NET™ Master Multidata, or Master Synchronized
layouts. It provides separate ports for Power Supply, External Trigger,
Digital I/O and Communication. Host communication is provided through
the integrated Ethernet module which connects internally to the reader's
Main serial interface. Reader Aux RS232 serial interface is also provided.
ID-NET™ network and power supply signals are sent out to the next
connected device by means of a dedicated port, however there is no
network input connector and therefore it cannot be used as an ID-NET™
Slave.
The QL series are compatible with the following readers:
DS2100N DS4800 Matrix 400™
DS2400N Matrix 200™
QL300
QL500
821001641 (Rev. A)
CONNECTIONS
ID-NET Out
M12 5P Female (A-coded)
Pin Function
1 Shield
2 Vdc
3 GND
4 ID+
5 ID-
QL300 only (ID-NET In)
M12 5P Male (A-coded)
Pin Function
1 Shield
2 nc
3 GND
4 ID+
5 ID-
QL500 only (Ethernet)
RJ45 8P Female
Pin Function
1 TX+
2 TX-
3 RX+
6 RX-
4, 5, 7, 8 nc
P8 P1
OVERALL DIMENSIONS
129
[4.56]
42
[1.49] 45
[1.59]
56
[1.98]
76
[2.67]
27
[0.95]
QL300
129
[4.56]
56
[1.98]
42
[1.49] 45
[1.59]
27
[0.95]
76
[2.67]
QL500
Power
M12 3P Male (B-coded)
Pin Function
1 Earth
2 Vdc
3 GND
Trigger
M12 4P Female (A-coded)
Pin Function
1 +V
2 nc
3 -V
4 I1+
MOUNTING
There are two self-threading screws provided for mounting the QLs to
various wooden or plastic surfaces. Mounting to other surfaces such as
concrete walls or metallic panels requires user-supplied parts (screws,
screw anchors, nuts, etc). Keep in mind that the connected reader must
have its Chassis grounded to Earth, see paragraph "Grounding".
QLs can also be mounted to a Bosch Frame using the BA200 mounting
accessory.
The distance between mounting bushings is given in the overall
dimension diagram for each QL.
NOTE
IP65 protection is provided when the cables (or QLs)
are properly mated.
GROUNDING
There are two general rules to follow regarding network grounding:
1) The network Shield must only be connected to Earth ground at
one point (the Master).
When using isolated power supplies, Earth grounding can be
accomplished through the CAB-PW-EXT accessory cable and the
BA400 or QL300/500 Power connector.
Power Supply
Earth ground connection
QL300
Power
CAB-PW-EXT
2) All reader Chassis must be connected to Earth ground.
All the readers in the network must have their Chassis connected to
Earth ground either by: mounting to conductive metal brackets or
frames which are connected to Earth ground; or through the CBX or
SC4000; or through the QL bushing.
In the case of grounding through the CBX or SC4000, connect the
Earth signal to a good earth ground and set the internal Chassis
jumper to Earth.
In the case of grounding through the QL bushing, connect a flying
lead from the mounting bushing to an Earth ground. The mounting
bushing is internally connected to the reader Chassis.
*pins 4 and 5 are nc for QL500.
*pins 4, 5, 12 and 15 are nc for QL500.
CAUTION
Do not connect GND and SGND to different (external)
ground references. GND and SGND are internally
connected through filtering circuitry which can be
permanently damaged if subjected to voltage drops over
0.8 Vdc.
ACCESSORIES
Description Part Number Connection
Cables
CAB-PW-EXT M12 POWER
EXTENSION CABLE
93A051381 Power
CBL-1480-01 THIN M12/5P
MALE/FEMALE 1M
CBL-1480-02 THIN M12/5P
MALE/FEMALE 2M
970101021
970101022 ID-NET Out/In
CAB-AUX04 15P DSUB TO DB9
SERIAL CABLE 3M
93A051386 I/O Port
Terminators
CBL-1490 TERM. RESIST.
THIN M12/5P/MALE
970101069 ID-NET Out
CBL-1496 TERM. RESIST.
THIN M12/5P/FEMALE
970101082 ID-NET In
Field Mountable Connectors
FMC400 M12 3P F. CONN. POWER 93ACC1884 Power
Mounting
BA200 Bosch Adaptors 93ACC1822
The FMC accessory connectors can be used to make custom External
Power and Service cables in case the standard cables don't satisfy the
application requirements.
Reader
25P D-Sub Female
1
142
5
13
Pin Function Pin Function
1,
shell,
both bushings
Reader Chassis
2 TXM 14 nc
3 RXM 15 nc
4 RTSM *16 nc
5 CTSM *17 nc
6 I2A 18 I1A
7 GND 19 GND
8 O1+ 20 RXA
9 nc 21 TXA
10 I2B 22 O1-
11 O2+ 23 ID+
12 O2- 24 ID-
13 Vdc 25 GND
I/O Port
15P HD D-Sub Female
1
6
15
5
11
10
Pin Function Pin Function
1 O1+ 9 I2A
2 TXA 10 O2-
3 RXA 11 I2B
4 RXM *12 TXM *
5 CTSM *13 GND
6 O1- 14 SGND
7 Vdc 15 RTSM *
8 O2+
mm
in
mm
in
TECHNICAL SPECIFICATIONS
ELECTRICAL FEATURES QL300 QL500
Supply Voltage 10 to 30 Vdc
(see Voltage Drop below)
Consumption - 210 mA - 70 mA
Maximum Distributed Current
Allowed
see related reading device manual
for consumption
4 A
Inputs see relative reader Reference Manual
Outputs see relative reader Reference Manual
PHYSICAL FEATURES
Mechanical Dimensions 129 x 76 x 27 mm
(5.1 x 3 x 1.1 in.)
Weight 312 g.
(11 oz.)
309
(10.9 oz.)
ENVIRONMENTAL FEATURES
Operating Temperature 0° to 50 C (+32° to 122 °F)
Storage Temperature -20° to 70 C (-4° to 158 °F)
Humidity max. 90% non condensing
Vibration Resistance 14 mm @ 2 to 10 Hz
EN 60068-2-6
2 hours on each axis
1.5 mm @ 13 to 55 Hz
2 g @ 70 to 200 Hz
Shock Resistance 30 g; 11 ms;
EN 60068-2-27 3 shocks on each axis
Protection Class
EN 60529
IP65
(when IP protection caps or
IP cables and reading
device are correctly
connected)
IP40
The features given are typical at a 25 C ambient temperature (if not otherwise
indicated).
VOLTAGE DROP AND MAX DISTRIBUTED CURRENT CALCULATIONS
For correct network management, the maximum number of readers which can
propagate power through the QLs must be calculated so that max distributed current is
not exceeded and so voltage drop doesn't affect reader functioning. This is done
according to the following formula:
Voltage Drop = (Max Reader Current x Number of readers) x
(Resistance per Meter per wire* x Cable length in Meters)
* the resistance calculation must include both wires (Vdc and GND).
Example:
An ID-NET™ network is composed of 4 DS2100N readers. Three 2 meter ThinNet
cables are used to connect the readers, which have Cable Resistance = 0.058 Ohms
per meter per wire. The network power is 24 Vdc.
(0.2083 A x 4 readers) x [(0.058 x 2) x 6 meters] = 0.58 Vdc voltage drop
24 Vdc - 0.58 = 23.42 Vdc at reader number 4 (worst case)
Integrate a sufficient number of QL200s to resupply network power.
TYPICAL LAYOUTS
Point to Point - Matrix 200™ with QL500 (Ethernet to Host)
1The reader connected to the QL500 must be configured for Ethernet communication. See the QL500
Ethernet Configuration sheet.
ID-NET™ Synchronized Network - Matrix 400™ Master with QL300
+ Matrix 400™ Slaves with QL150
TRIGGER
In order to allow direct trigger cabling between the photocell and the QL300/500 using standard M12 A-
coded one-to-one cables, the trigger signal has been internally wired to manage PNP type photocells. The
external trigger therefore must be connected as shown in the diagram below.
EXTERNAL TRIGGER
Ground
V
Signal
VCC ~
~
+-
READ ER
19
13 Vdc
I1B
QL300/500
2
1+V
nc
19
13
Trigger
18 I1
A
4I1+18
7 GND 3-V
7
Power 1
Vdc
23
GND
Reader
The electrical features of both inputs and outputs are given in the relative reader Reference Manual.
ID-NET™ Synchronized Network - DS4800 Master with QL500
+ DS4800 Slaves with QL200 and QL100
1The reader connected to the QL500 must be configured for Ethernet communication. See the QL500
Ethernet Configuration sheet.
2The above diagram is an example showing layout connections and is not intended to represent power
limits, which instead, depend on each specific application. See "Voltage Drop and Max Distributed
Current Calculations".
ID-NET™ Multidata Network - DS4800 Master with QL300
+ Mixed Reader Slaves with QL300s
COMPLIANCE
FCC Compliance
Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to
use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
CE Compliance
Warning:
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may
be required to take adequate measures.
Power Supply
This product is intended to be installed by Qualified Personnel only.
This accessory device is intended to be supplied by a UL Listed or CSA Certified Power Unit with «Class 2» or LPS power
source.
Host QL500 1
PS
Power I/O
CAB-PW-EXT
Matrix 200™
Ethernet
Host
QL150
PS
Power
Main Interface
CBL-1490
ID-NET
Terminator
The ID-NET network must be terminated inserting an
ID-NET terminator into the QL300 (Master) and into the
last QL in the network.
Slave Nodes
CBL-1480-xx
CAB-PW-EXT
CBL-1480-xx
CAB-AUX03 CAB-AUX03
QL300
CBL-1496
ID-NET
Terminator
Master
QL150
ID-NET™
Host
QL200 2
PS
Power
Ethernet Interface
CBL-1490
ID-NET
Terminator
The ID-NET network must be terminated
inserting an ID-NET terminator into the last
QL in the network.
ID-NET on the QL500 is internally
terminated.
Slave Nodes
CBL-1480-xx
CAB-PW-EXT
CBL-1480-xx
Power
QL500 1
Master
QL100ID-NET™
Host
QL300
PS
CBL-1490
ID-NET
Terminator
The ID-NET network must be terminated inserting an
ID-NET terminator into the QL300 (Master) and into the
last QL300 in the network.
Slave
CBL-1480-xx
A
UX Port
CBL-1480-xx
Power
QL300 Master QL300
Power Power
Slave
PS PS
CBL-1496
ID-NET
Terminator
ID-NET™

This manual suits for next models

2

Other Datalogic Cables And Connectors manuals

Datalogic 94ACC0174 User manual

Datalogic

Datalogic 94ACC0174 User manual

Datalogic Win-Net Vehicle PWR Cab HRS 3500-16P-CV User manual

Datalogic

Datalogic Win-Net Vehicle PWR Cab HRS 3500-16P-CV User manual

Datalogic QL300 User manual

Datalogic

Datalogic QL300 User manual

Datalogic QL300 User manual

Datalogic

Datalogic QL300 User manual

Datalogic 94ACC0160 User manual

Datalogic

Datalogic 94ACC0160 User manual

Popular Cables And Connectors manuals by other brands

knapp FIXclip H12 instruction manual

knapp

knapp FIXclip H12 instruction manual

Lindy 32569 user manual

Lindy

Lindy 32569 user manual

Kiramek OB-23 manual

Kiramek

Kiramek OB-23 manual

TRENDnet TK-C15 - DATA SHEETS Other

TRENDnet

TRENDnet TK-C15 - DATA SHEETS Other

CYP CDPS-4KQ Operation manual

CYP

CYP CDPS-4KQ Operation manual

Manhattan 510424 instructions

Manhattan

Manhattan 510424 instructions

Farnell NI-9214 Getting started

Farnell

Farnell NI-9214 Getting started

Lindy 41307 user manual

Lindy

Lindy 41307 user manual

Leviton 5G110-RX5 Instructions for use

Leviton

Leviton 5G110-RX5 Instructions for use

Parkside 280209 Translation of the original instructions

Parkside

Parkside 280209 Translation of the original instructions

Goobay 90658 user manual

Goobay

Goobay 90658 user manual

VPC VTAC HSD user manual

VPC

VPC VTAC HSD user manual

AVGear AVG-UDATP4 user manual

AVGear

AVGear AVG-UDATP4 user manual

ORVIS Battenkill Mid Arbor quick start guide

ORVIS

ORVIS Battenkill Mid Arbor quick start guide

PIRIT Heated Hose PWL-03-12 Care and use

PIRIT

PIRIT Heated Hose PWL-03-12 Care and use

Philips SWV3537 Specifications

Philips

Philips SWV3537 Specifications

Titanium TT-FL00-4P-MF Connection instructions

Titanium

Titanium TT-FL00-4P-MF Connection instructions

CYP CLUX-4M Operation manual

CYP

CYP CLUX-4M Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.