S85-MH-5-Y
Distance sensor with laser emission and time of flight measurement
INSTRUCTION MANUAL
CONTROLS
INSTALLATION
The installation of the sensor can be carried out thanks to the two through holes on the body, by means
of screws (eg M4x45 UNI5739) with nuts and washers.
To install the product only and always refer to the reference surface (A) shown in Fig.1.
There are orientable fixing brackets to ease the sensor positioning (see Accessories catalog).
With direct fixing it has a range of angular adjustment of the laser emission of ± 1.5 °. The measure is
referred to the front surface of the sensor as in Fig.2.
Fig.1
Ref.
Fig.2
1) Connect and secure the M12 connector power free.
2) Connect the cable to power supply and/or I/O as for indicated for each model.
3) Fix the sensor to suitable support, taking care to align the laser spot on the center of target
before.
4) Measure will be available within few seconds from power on.
5) Wait for warm up time before to start operation.
6) Configure device unlocking by contemporarily push of for S85-MH-5-Y13 (device
automatically lock configuration at the end of configuration)
CONNECTIONS
N.B.: Color of wires are referred to european standard.
CONFIGURATION SETTING FOR S85-MH-5-Y03
Push buttons 3sec at least and release them when dedicated LED blinks
Push MIN to teach scalable range “min” until blinking of LED yellow 1
Push MAX to teach scalable range “max” until blinking of LED yellow 2
Push Q1 to teach switching point 1 until blinking of LED yellow 1
Push Q2 to teach switching point 2 until blinking of LED yellow 2
Push MIN + MAX to restore range default values until blinking of LED green 3
Push MAX + Q1 / MIN + Q2 to restore default switching point 1/2 until blinking of LED
green 3 ( = 500 mm )
Background suppressor mode Foreground suppressor mode
CONFIGURATION SETTING FOR S85-MH-5-Y13
TECHNICAL DATA
S85-MH-5-Y03-OOV S85-MH-5-Y03-OOI S85-MH-5-Y13-OOIVY S85-MH-5-Y13-OOY
Power supply: 24 VDC ± 20%
Consumption: < 2.8 W < 3 W
Measurement range: 0,2..10 m (90% white) / 0,2..5 m (18% grey) /
0,2..3 m (6 % black)
0.2..20 m (90% white) / 0.2..8 m (18% grey) /
0.2..5 m (6 % black)
Accuracy (1 sigma / 90% white XRite target): 10 mm 7 mm (slow response time)
Repeatibility (1 sigma / 90% white XRite target): 1 mm 1 mm up to 10 m / < 2 mm up to 20 m (slow response time)
Resolution: 1 mm / 16 bit
Hysteresis: 10mm configurable (5 … 1000 mm)
Analogue output:
(*Linearity error ±0.03% FSV, ±0.02% FS)
0.2-10 V scalable
(1200 min)
short-circuit protection
4-20 mA scalable
(100 max.)
short-circuit protection
Configurable
(0.2-10V / 4-20 mA /scalable)
short-circuit protection
Not availble
Response time SLOW : -45 msec ( typ )
Response time MEDIUM: 30 msec ( typ )
Response time FAST: 15 msec ( typ )
RS 485
output stream:
Not available
Input command:
Switching output / Alarm: Push Pull / Q Configurable (PNP NPN Push Pull Q Qneg)
Multifunction input: not available See par. “Default Configuration”
Warm up time: 20 min typ
Indicators: Q1 (YELLOW) / Q2 (YELLOW) / POWER ON (GREEN) - OUT OF RANGE (RED)
5-digit / multi display (only for S85-MH-5-Y13-OOIVY / OOY)
Operating temperature: -15 … 50 °C (with powered devices) - reduce the min temp. to -5°C in case of cold power on
Storage temperature: -25 … 70 °C
Dielectric strength: 500 VAC, 1 min between electronics and housing
Insulating resistance: > 20 M
, 500 VDC between electronics and housing
Typical spot dimension (T = 25°C) typ 15mm @ 8m typ 15mm @ 8m typ 15mm @ 10m typ 15mm @ 10m
Laser power emission / Pulse duration: 1 mW / 4 nsec
Wavelenght : 658 nm
Laser class emission: CLASS 2 According to IEC 60825-1 (2007)
Ambient light rejection: According to EN 60947-5-2, >40 Klux DC ambient light
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Humidity: < 90% not condensed
Housing material: ZINC ALLOY ZAMA 13 EN-1774 / Display: PC LEXAN 121R
Lens material: PMMA
Mechanical protection: IP67
Connections: M12 - 5 poles M12 - 8 poles
Dimension ( max shape): 58 x 61 x 37 mm
Peso 250 gr.max.
UL requirements: Class 2 power supply according to UL 508 - Type 1 Enclosure
minimum distance between the “Proximity Switch Metal Enclosure” and any “External uninsulated live part” shall be at least 12.7 mm
CDRH requirements: Complies with 21 CFR 1040.10 and 1040.11
DEFAULT CONFIGURATION
DETECTION DIAGRAMS
DIMENSIONS
SAFETY WARNINGS
All the safety electrical and mechanical regulations
and laws have to be respected during sensor
functioning. The sensor has to be protected against
mechanical damages.
Do not look directly into the laser beam!
Do not point the laser beam towards people!
Eye irradiation for over 0.25 seconds is dangerous; refer to class 2 standard (EN60825-1).
This product is intended for indoor use only.
Use of controls or adjustments or performance or procedures other than those specified herein may
result in hazardous radiation exposure.
MAINTENANCE
Device do not need for particular maintenance. Anycase, take care to clean optic surface with compliant
cleanser in order to avoid decay of performance . Use protection for plastic parts in case of hazardous
environment .
The sensors are NOT safety devices, and so MUST NOT be used in the safety control of
the machines where installed.
DECLARATION OF CONFORMITY
We Datalogic Automation declare under our sole responsibility that these products are conform to the
2004/108/CE and successive amendments.
WARRANTY
Datalogic Automation warrants its products to be free from defects.
Datalogic Automation will repair or replace, free of charge, any product found to be defective during the
warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of Datalogic
Automation products.
DATALOGIC AUTOMATION srl
ia Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy
el: +39 051 6765611 - Fax: +39 051 6759324 www.datalogic.com
DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification.
© 2013 – 2014 Datalogic Automation - ALL RIGHTS RESERVED - Protected to the fullest extent under U.S. and international
laws. • Copying, or altering of this document is prohibited without express written consent from Datalogic Automation.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and
the E.U.
821002573 Rev.C
OUTPUT LED (yellow)
Yellow led’s 1 and 2 light on, show digital outputs
Q1 e Q2 enable
OUT OF RANGE / POWER ON LED (red/green)
Led 3 light on RED shows the out of range
measures.
Led 3 light on GREEN shows the sensor power on
and the laser emission activations
EVALUATI
E
ANALOGUE
OUTPUT
EVALUATIVE
ANALOGUE
OUTPUT
S85-MH-5-Y
Distance sensor with laser emission and time of flight measurement
INSTRUCTION MANUAL
CONTROLS
INSTALLATION
The installation of the sensor can be carried out thanks to the two through holes on the body, by means
of screws (eg M4x45 UNI5739) with nuts and washers.
To install the product only and always refer to the reference surface (A) shown in Fig.1.
There are orientable fixing brackets to ease the sensor positioning (see Accessories catalog).
With direct fixing it has a range of angular adjustment of the laser emission of ± 1.5 °. The measure is
referred to the front surface of the sensor as in Fig.2.
Fig.1
Ref.
Fig.2
1) Connect and secure the M12 connector power free.
2) Connect the cable to power supply and/or I/O as for indicated for each model.
3) Fix the sensor to suitable support, taking care to align the laser spot on the center of target
before.
4) Measure will be available within few seconds from power on.
5) Wait for warm up time before to start operation.
6) Configure device unlocking by contemporarily push of for S85-MH-5-Y13 (device
automatically lock configuration at the end of configuration)
CONNECTIONS
N.B.: Color of wires are referred to european standard.
CONFIGURATION SETTING FOR S85-MH-5-Y03
Push buttons 3sec at least and release them when dedicated LED blinks
Push MIN to teach scalable range “min” until blinking of LED yellow 1
Push MAX to teach scalable range “max” until blinking of LED yellow 2
Push Q1 to teach switching point 1 until blinking of LED yellow 1
Push Q2 to teach switching point 2 until blinking of LED yellow 2
Push MIN + MAX to restore range default values until blinking of LED green 3
Push MAX + Q1 / MIN + Q2 to restore default switching point 1/2 until blinking of LED
green 3 ( = 500 mm )
Background suppressor mode Foreground suppressor mode
CONFIGURATION SETTING FOR S85-MH-5-Y13
TECHNICAL DATA
S85-MH-5-Y03-OOV S85-MH-5-Y03-OOI S85-MH-5-Y13-OOIVY S85-MH-5-Y13-OOY
Power supply: 24 VDC ± 20%
Consumption: < 2.8 W < 3 W
Measurement range: 0,2..10 m (90% white) / 0,2..5 m (18% grey) /
0,2..3 m (6 % black)
0.2..20 m (90% white) / 0.2..8 m (18% grey) /
0.2..5 m (6 % black)
Accuracy (1 sigma / 90% white XRite target): 10 mm 7 mm (slow response time)
Repeatibility (1 sigma / 90% white XRite target): 1 mm 1 mm up to 10 m / < 2 mm up to 20 m (slow response time)
Resolution: 1 mm / 16 bit
Hysteresis: 10mm configurable (5 … 1000 mm)
Analogue output:
(*Linearity error ±0.03% FSV, ±0.02% FS)
0.2-10 V scalable
(1200 min)
short-circuit protection
4-20 mA scalable
(100 max.)
short-circuit protection
Configurable
(0.2-10V / 4-20 mA /scalable)
short-circuit protection
Not availble
Response time SLOW : -45 msec ( typ )
Response time MEDIUM: 30 msec ( typ )
Response time FAST: 15 msec ( typ )
RS 485
output stream:
Not available
Input command:
Switching output / Alarm: Push Pull / Q Configurable (PNP NPN Push Pull Q Qneg)
Multifunction input: not available See par. “Default Configuration”
Warm up time: 20 min typ
Indicators: Q1 (YELLOW) / Q2 (YELLOW) / POWER ON (GREEN) - OUT OF RANGE (RED)
5-digit / multi display (only for S85-MH-5-Y13-OOIVY / OOY)
Operating temperature: -15 … 50 °C (with powered devices) - reduce the min temp. to -5°C in case of cold power on
Storage temperature: -25 … 70 °C
Dielectric strength: 500 VAC, 1 min between electronics and housing
Insulating resistance: > 20 M
, 500 VDC between electronics and housing
Typical spot dimension (T = 25°C) typ 15mm @ 8m typ 15mm @ 8m typ 15mm @ 10m typ 15mm @ 10m
Laser power emission / Pulse duration: 1 mW / 4 nsec
Wavelenght : 658 nm
Laser class emission: CLASS 2 According to IEC 60825-1 (2007)
Ambient light rejection: According to EN 60947-5-2, >40 Klux DC ambient light
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Humidity: < 90% not condensed
Housing material: ZINC ALLOY ZAMA 13 EN-1774 / Display: PC LEXAN 121R
Lens material: PMMA
Mechanical protection: IP67
Connections: M12 - 5 poles M12 - 8 poles
Dimension ( max shape): 58 x 61 x 37 mm
Peso 250 gr.max.
UL requirements: Class 2 power supply according to UL 508 - Type 1 Enclosure
minimum distance between the “Proximity Switch Metal Enclosure” and any “External uninsulated live part” shall be at least 12.7 mm
CDRH requirements: Complies with 21 CFR 1040.10 and 1040.11
DEFAULT CONFIGURATION
DETECTION DIAGRAMS
DIMENSIONS
SAFETY WARNINGS
All the safety electrical and mechanical regulations
and laws have to be respected during sensor
functioning. The sensor has to be protected against
mechanical damages.
Do not look directly into the laser beam!
Do not point the laser beam towards people!
Eye irradiation for over 0.25 seconds is dangerous; refer to class 2 standard (EN60825-1).
This product is intended for indoor use only.
Use of controls or adjustments or performance or procedures other than those specified herein may
result in hazardous radiation exposure.
MAINTENANCE
Device do not need for particular maintenance. Anycase, take care to clean optic surface with compliant
cleanser in order to avoid decay of performance . Use protection for plastic parts in case of hazardous
environment .
The sensors are NOT safety devices, and so MUST NOT be used in the safety control of
the machines where installed.
DECLARATION OF CONFORMITY
We Datalogic Automation declare under our sole responsibility that these products are conform to the
2004/108/CE and successive amendments.
WARRANTY
Datalogic Automation warrants its products to be free from defects.
Datalogic Automation will repair or replace, free of charge, any product found to be defective during the
warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of Datalogic
Automation products.
DATALOGIC AUTOMATION srl
ia Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy
el: +39 051 6765611 - Fax: +39 051 6759324 www.datalogic.com
DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification.
© 2013 – 2014 Datalogic Automation - ALL RIGHTS RESERVED - Protected to the fullest extent under U.S. and international
laws. • Copying, or altering of this document is prohibited without express written consent from Datalogic Automation.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and
the E.U.
821002573 Rev.C
OUTPUT LED (yellow)
Yellow led’s 1 and 2 light on, show digital outputs
Q1 e Q2 enable
OUT OF RANGE / POWER ON LED (red/green)
Led 3 light on RED shows the out of range
measures.
Led 3 light on GREEN shows the sensor power on
and the laser emission activations
EVALUATI
E
ANALOGUE
OUTPUT
EVALUATIVE
ANALOGUE
OUTPUT
S85-MH-5-Y
Distance sensor with laser emission and time of flight measurement
INSTRUCTION MANUAL
CONTROLS
INSTALLATION
The installation of the sensor can be carried out thanks to the two through holes on the body, by means
of screws (eg M4x45 UNI5739) with nuts and washers.
To install the product only and always refer to the reference surface (A) shown in Fig.1.
There are orientable fixing brackets to ease the sensor positioning (see Accessories catalog).
With direct fixing it has a range of angular adjustment of the laser emission of ± 1.5 °. The measure is
referred to the front surface of the sensor as in Fig.2.
Fig.1
Ref.
Fig.2
1) Connect and secure the M12 connector power free.
2) Connect the cable to power supply and/or I/O as for indicated for each model.
3) Fix the sensor to suitable support, taking care to align the laser spot on the center of target
before.
4) Measure will be available within few seconds from power on.
5) Wait for warm up time before to start operation.
6) Configure device unlocking by contemporarily push of for S85-MH-5-Y13 (device
automatically lock configuration at the end of configuration)
CONNECTIONS
N.B.: Color of wires are referred to european standard.
CONFIGURATION SETTING FOR S85-MH-5-Y03
Push buttons 3sec at least and release them when dedicated LED blinks
Push MIN to teach scalable range “min” until blinking of LED yellow 1
Push MAX to teach scalable range “max” until blinking of LED yellow 2
Push Q1 to teach switching point 1 until blinking of LED yellow 1
Push Q2 to teach switching point 2 until blinking of LED yellow 2
Push MIN + MAX to restore range default values until blinking of LED green 3
Push MAX + Q1 / MIN + Q2 to restore default switching point 1/2 until blinking of LED
green 3 ( = 500 mm )
Background suppressor mode Foreground suppressor mode
CONFIGURATION SETTING FOR S85-MH-5-Y13
TECHNICAL DATA
S85-MH-5-Y03-OOV S85-MH-5-Y03-OOI S85-MH-5-Y13-OOIVY S85-MH-5-Y13-OOY
Power supply: 24 VDC ± 20%
Consumption: < 2.8 W < 3 W
Measurement range: 0,2..10 m (90% white) / 0,2..5 m (18% grey) /
0,2..3 m (6 % black)
0.2..20 m (90% white) / 0.2..8 m (18% grey) /
0.2..5 m (6 % black)
Accuracy (1 sigma / 90% white XRite target): 10 mm 7 mm (slow response time)
Repeatibility (1 sigma / 90% white XRite target): 1 mm 1 mm up to 10 m / < 2 mm up to 20 m (slow response time)
Resolution: 1 mm / 16 bit
Hysteresis: 10mm configurable (5 … 1000 mm)
Analogue output:
(*Linearity error ±0.03% FSV, ±0.02% FS)
0.2-10 V scalable
(1200 min)
short-circuit protection
4-20 mA scalable
(100 max.)
short-circuit protection
Configurable
(0.2-10V / 4-20 mA /scalable)
short-circuit protection
Not availble
Response time SLOW : -45 msec ( typ )
Response time MEDIUM: 30 msec ( typ )
Response time FAST: 15 msec ( typ )
RS 485
output stream:
Not available
Input command:
Switching output / Alarm: Push Pull / Q Configurable (PNP NPN Push Pull Q Qneg)
Multifunction input: not available See par. “Default Configuration”
Warm up time: 20 min typ
Indicators: Q1 (YELLOW) / Q2 (YELLOW) / POWER ON (GREEN) - OUT OF RANGE (RED)
5-digit / multi display (only for S85-MH-5-Y13-OOIVY / OOY)
Operating temperature: -15 … 50 °C (with powered devices) - reduce the min temp. to -5°C in case of cold power on
Storage temperature: -25 … 70 °C
Dielectric strength: 500 VAC, 1 min between electronics and housing
Insulating resistance: > 20 M
, 500 VDC between electronics and housing
Typical spot dimension (T = 25°C) typ 15mm @ 8m typ 15mm @ 8m typ 15mm @ 10m typ 15mm @ 10m
Laser power emission / Pulse duration: 1 mW / 4 nsec
Wavelenght : 658 nm
Laser class emission: CLASS 2 According to IEC 60825-1 (2007)
Ambient light rejection: According to EN 60947-5-2, >40 Klux DC ambient light
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Humidity: < 90% not condensed
Housing material: ZINC ALLOY ZAMA 13 EN-1774 / Display: PC LEXAN 121R
Lens material: PMMA
Mechanical protection: IP67
Connections: M12 - 5 poles M12 - 8 poles
Dimension ( max shape): 58 x 61 x 37 mm
Peso 250 gr.max.
UL requirements: Class 2 power supply according to UL 508 - Type 1 Enclosure
minimum distance between the “Proximity Switch Metal Enclosure” and any “External uninsulated live part” shall be at least 12.7 mm
CDRH requirements: Complies with 21 CFR 1040.10 and 1040.11
DEFAULT CONFIGURATION
DETECTION DIAGRAMS
DIMENSIONS
SAFETY WARNINGS
All the safety electrical and mechanical regulations
and laws have to be respected during sensor
functioning. The sensor has to be protected against
mechanical damages.
Do not look directly into the laser beam!
Do not point the laser beam towards people!
Eye irradiation for over 0.25 seconds is dangerous; refer to class 2 standard (EN60825-1).
This product is intended for indoor use only.
Use of controls or adjustments or performance or procedures other than those specified herein may
result in hazardous radiation exposure.
MAINTENANCE
Device do not need for particular maintenance. Anycase, take care to clean optic surface with compliant
cleanser in order to avoid decay of performance . Use protection for plastic parts in case of hazardous
environment .
The sensors are NOT safety devices, and so MUST NOT be used in the safety control of
the machines where installed.
DECLARATION OF CONFORMITY
We Datalogic Automation declare under our sole responsibility that these products are conform to the
2004/108/CE and successive amendments.
WARRANTY
Datalogic Automation warrants its products to be free from defects.
Datalogic Automation will repair or replace, free of charge, any product found to be defective during the
warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of Datalogic
Automation products.
DATALOGIC AUTOMATION srl
ia Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy
el: +39 051 6765611 - Fax: +39 051 6759324 www.datalogic.com
DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification.
© 2013 – 2014 Datalogic Automation - ALL RIGHTS RESERVED - Protected to the fullest extent under U.S. and international
laws. • Copying, or altering of this document is prohibited without express written consent from Datalogic Automation.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and
the E.U.
821002573 Rev.C
OUTPUT LED (yellow)
Yellow led’s 1 and 2 light on, show digital outputs
Q1 e Q2 enable
OUT OF RANGE / POWER ON LED (red/green)
Led 3 light on RED shows the out of range
measures.
Led 3 light on GREEN shows the sensor power on
and the laser emission activations
EVALUATI
E
ANALOGUE
OUTPUT
EVALUATIVE
ANALOGUE
OUTPUT
S85-MH-5-Y
Distance sensor with laser emission and time of flight measurement
INSTRUCTION MANUAL
CONTROLS
INSTALLATION
The installation of the sensor can be carried out thanks to the two through holes on the body, by means
of screws (eg M4x45 UNI5739) with nuts and washers.
To install the product only and always refer to the reference surface (A) shown in Fig.1.
There are orientable fixing brackets to ease the sensor positioning (see Accessories catalog).
With direct fixing it has a range of angular adjustment of the laser emission of ± 1.5 °. The measure is
referred to the front surface of the sensor as in Fig.2.
Fig.1
Ref.
Fig.2
1) Connect and secure the M12 connector power free.
2) Connect the cable to power supply and/or I/O as for indicated for each model.
3) Fix the sensor to suitable support, taking care to align the laser spot on the center of target
before.
4) Measure will be available within few seconds from power on.
5) Wait for warm up time before to start operation.
6) Configure device unlocking by contemporarily push of for S85-MH-5-Y13 (device
automatically lock configuration at the end of configuration)
CONNECTIONS
N.B.: Color of wires are referred to european standard.
CONFIGURATION SETTING FOR S85-MH-5-Y03
Push buttons 3sec at least and release them when dedicated LED blinks
Push MIN to teach scalable range “min” until blinking of LED yellow 1
Push MAX to teach scalable range “max” until blinking of LED yellow 2
Push Q1 to teach switching point 1 until blinking of LED yellow 1
Push Q2 to teach switching point 2 until blinking of LED yellow 2
Push MIN + MAX to restore range default values until blinking of LED green 3
Push MAX + Q1 / MIN + Q2 to restore default switching point 1/2 until blinking of LED
green 3 ( = 500 mm )
Background suppressor mode Foreground suppressor mode
CONFIGURATION SETTING FOR S85-MH-5-Y13
TECHNICAL DATA
S85-MH-5-Y03-OOV S85-MH-5-Y03-OOI S85-MH-5-Y13-OOIVY S85-MH-5-Y13-OOY
Power supply: 24 VDC ± 20%
Consumption: < 2.8 W < 3 W
Measurement range: 0,2..10 m (90% white) / 0,2..5 m (18% grey) /
0,2..3 m (6 % black)
0.2..20 m (90% white) / 0.2..8 m (18% grey) /
0.2..5 m (6 % black)
Accuracy (1 sigma / 90% white XRite target): 10 mm 7 mm (slow response time)
Repeatibility (1 sigma / 90% white XRite target): 1 mm 1 mm up to 10 m / < 2 mm up to 20 m (slow response time)
Resolution: 1 mm / 16 bit
Hysteresis: 10mm configurable (5 … 1000 mm)
Analogue output:
(*Linearity error ±0.03% FSV, ±0.02% FS)
0.2-10 V scalable
(1200 min)
short-circuit protection
4-20 mA scalable
(100 max.)
short-circuit protection
Configurable
(0.2-10V / 4-20 mA /scalable)
short-circuit protection
Not availble
Response time SLOW : -45 msec ( typ )
Response time MEDIUM: 30 msec ( typ )
Response time FAST: 15 msec ( typ )
RS 485
output stream:
Not available
Input command:
Switching output / Alarm: Push Pull / Q Configurable (PNP NPN Push Pull Q Qneg)
Multifunction input: not available See par. “Default Configuration”
Warm up time: 20 min typ
Indicators: Q1 (YELLOW) / Q2 (YELLOW) / POWER ON (GREEN) - OUT OF RANGE (RED)
5-digit / multi display (only for S85-MH-5-Y13-OOIVY / OOY)
Operating temperature: -15 … 50 °C (with powered devices) - reduce the min temp. to -5°C in case of cold power on
Storage temperature: -25 … 70 °C
Dielectric strength: 500 VAC, 1 min between electronics and housing
Insulating resistance: > 20 M
, 500 VDC between electronics and housing
Typical spot dimension (T = 25°C) typ 15mm @ 8m typ 15mm @ 8m typ 15mm @ 10m typ 15mm @ 10m
Laser power emission / Pulse duration: 1 mW / 4 nsec
Wavelenght : 658 nm
Laser class emission: CLASS 2 According to IEC 60825-1 (2007)
Ambient light rejection: According to EN 60947-5-2, >40 Klux DC ambient light
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Humidity: < 90% not condensed
Housing material: ZINC ALLOY ZAMA 13 EN-1774 / Display: PC LEXAN 121R
Lens material: PMMA
Mechanical protection: IP67
Connections: M12 - 5 poles M12 - 8 poles
Dimension ( max shape): 58 x 61 x 37 mm
Peso 250 gr.max.
UL requirements: Class 2 power supply according to UL 508 - Type 1 Enclosure
minimum distance between the “Proximity Switch Metal Enclosure” and any “External uninsulated live part” shall be at least 12.7 mm
CDRH requirements: Complies with 21 CFR 1040.10 and 1040.11
DEFAULT CONFIGURATION
DETECTION DIAGRAMS
DIMENSIONS
SAFETY WARNINGS
All the safety electrical and mechanical regulations
and laws have to be respected during sensor
functioning. The sensor has to be protected against
mechanical damages.
Do not look directly into the laser beam!
Do not point the laser beam towards people!
Eye irradiation for over 0.25 seconds is dangerous; refer to class 2 standard (EN60825-1).
This product is intended for indoor use only.
Use of controls or adjustments or performance or procedures other than those specified herein may
result in hazardous radiation exposure.
MAINTENANCE
Device do not need for particular maintenance. Anycase, take care to clean optic surface with compliant
cleanser in order to avoid decay of performance . Use protection for plastic parts in case of hazardous
environment .
The sensors are NOT safety devices, and so MUST NOT be used in the safety control of
the machines where installed.
DECLARATION OF CONFORMITY
We Datalogic Automation declare under our sole responsibility that these products are conform to the
2004/108/CE and successive amendments.
WARRANTY
Datalogic Automation warrants its products to be free from defects.
Datalogic Automation will repair or replace, free of charge, any product found to be defective during the
warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of Datalogic
Automation products.
DATALOGIC AUTOMATION srl
ia Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy
el: +39 051 6765611 - Fax: +39 051 6759324 www.datalogic.com
DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification.
© 2013 – 2014 Datalogic Automation - ALL RIGHTS RESERVED - Protected to the fullest extent under U.S. and international
laws. • Copying, or altering of this document is prohibited without express written consent from Datalogic Automation.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and
the E.U.
821002573 Rev.C
OUTPUT LED (yellow)
Yellow led’s 1 and 2 light on, show digital outputs
Q1 e Q2 enable
OUT OF RANGE / POWER ON LED (red/green)
Led 3 light on RED shows the out of range
measures.
Led 3 light on GREEN shows the sensor power on
and the laser emission activations
EVALUATI
E
ANALOGUE
OUTPUT
EVALUATIVE
ANALOGUE
OUTPUT
1 2 3
M12 CONNECTOR ADVANCED
M12 CONNECTOR STANDARD
S85-Y03-OOV
Voltage version
S85-Y13-OOIVY
Analog version
S85-Y13-OOY
S85-Y03-OOI
Current version
MENU FUNCTIONS
OUT 1 Switching point1: Light/Dark; Switching point value; PNP, NPN,
Push-pull; Alarm
OUT 2 Switching point 2: Light/Dark; Switching point value; PNP, NPN,
Push-pull; Alarm
HYSTERESIS Hysteresis level: 5…1000 mm
ANALOG OUT Voltage (0…10 V); Current (4…20 mA)
MULTIFUNCTION IN LASER OFF; Teach IN (Thresholds); RS485 Send Data
AVERAGE Response time: SLOW; MEDIUM; FAST
RS485 Node N°; Enable; Termination; Output mode; Delay (0…254 ms)
SCALABLE OUT Analog output range: Reset, MIN and MAX distance
FACTORY RESET Factory default values
INFO Soware version
INDICATORS
LED 1 Q1 (yellow)
LED 2 Q2 (yellow)
LED 3 POWER ON (green),
OUT OF RANGE (red)
DISPLAY
Run/W.UP →Run mode or Warm-up mode
Q+Q →Digital Output setting →PNP/NPN/Push-Pull
I/V →Analog Output Setting →Ampere/Volt
Lock Symbol →Keylock or unlock
5-digit display →Value corresponds to Distance in mm
CONNECTIONS
INDICATORS AND SETTINGS
Without the procedure setting the sensor is configured to measure distances on a white target from a minimum value of 200 mm and a maximum of
20000 mm, with both switching point placed at 500 mm.
The parameters can be changed by the menu on the display pointing the LASER on the target in the different interested points.